Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Front Endocrinol (Lausanne) ; 14: 1161116, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37455915

RESUMO

Objective: a) To evaluate the accuracy of the pre-existing equations (based on cm2 provided by CT images), to estimate in kilograms (Kg) the body composition (BC) in patients with obesity (PwO), by comparison with Dual-energy X-ray absorptiometry (DXA). b) To evaluate the accuracy of a new approach (based on both cm2 and Hounsfield Unit parameters provided by CT images), using an automatic software and artificial intelligence to estimate the BC in PwO, by comparison with DXA. Methods: Single-centre cross-sectional study including consecutive PwO, matched by gender with subjects with normal BMI. All the subjects underwent BC assessment by Dual-energy X-ray absorptiometry (DXA) and skeletal-CT at L3 vertebrae. CT images were processed using FocusedON-BC software. Three different models were tested. Model 1 and 2, based on the already existing equations, estimate the BC in Kg based on the tissue area (cm2) in the CT images. Model 3, developed in this study, includes as additional variables, the tissue percentage and its average Hounsfield unit. Results: 70 subjects (46 PwO and 24 with normal BMI) were recruited. Significant correlations for BC were obtained between the three models and DXA. Model 3 showed the strongest correlation with DXA (r= 0.926, CI95% [0.835-0.968], p<0.001) as well as the best agreement based on Bland - Altman plots. Conclusion: This is the first study showing that the BC assessment based on skeletal CT images analyzed by automatic software coupled with artificial intelligence, is accurate in PwO, by comparison with DXA. Furthermore, we propose a new equation that estimates both the tissue quantity and quality, that showed higher accuracy compared with those currently used, both in PwO and subjects with normal BMI.


Assuntos
Inteligência Artificial , Composição Corporal , Humanos , Absorciometria de Fóton/métodos , Estudos Transversais , Obesidade/diagnóstico por imagem , Tomografia Computadorizada por Raios X
2.
Eur Heart J Cardiovasc Imaging ; 23(9): 1260-1271, 2022 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-34999818

RESUMO

AIMS: Diagnosis of prosthetic valve endocarditis (PVE) by positron emission computed tomography angiography (PET/CTA) is based on visual and quantitative morpho-metabolic features. However, the fluorodeoxyglucose (FDG) uptake pattern can be sometimes visually unclear and susceptible to subjectivity. This study aimed to validate a new parameter, the valve uptake index [VUI, maximum standardized uptake value (SUVmax)-mean standardized uptake value (SUVmean)/SUVmax], designed to provide a more objective indication of the distribution of metabolic activity. Secondly, to re-evaluate the utility of traditionally used PVE imaging criteria and determine the potential value of adding the VUI in the diagnostic algorithm of PVE. METHODS AND RESULTS: Retrospective analysis of 122 patients (135 prosthetic valves) admitted for suspicion of endocarditis, with a conclusive diagnosis of definite (N = 57) or rejected (N = 65) PVE, and who had undergone a cardiac PET/CTA scan as part of the diagnostic evaluation. We measured the VUI and recorded the SUVmax, SUVratio, uptake pattern, and the presence of endocarditis-related anatomic lesions. The VUI, SUVmax, and SUVratio values were 0.54 ± 0.1 vs. 0.36 ± 0.08, 7.68 ± 3.07 vs. 3.72 ± 1.11, and 4.28 ± 1.93 vs. 2.16 ± 0.95 in the 'definite' PVE group vs. the 'rejected' group, respectively (mean ± SD; P < 0.001). A cut-off value of VUI > 0.45 showed a sensitivity, specificity, and diagnostic accuracy for PVE of 85%, 88%, and 86.7% and increased diagnostic ability for confirming endocarditis when combined with the standard diagnostic criteria. CONCLUSIONS: The VUI demonstrated good diagnostic accuracy for PVE, even increasing the diagnostic power of the traditionally used morphometabolic parameters, which also confirmed their own diagnostic performance. More research is needed to assess whether the integration of the VUI into the PVE diagnostic algorithm may clarify doubtful cases and thus improve the diagnostic yield of PET/CTA.


Assuntos
Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Infecções Relacionadas à Prótese , Endocardite/diagnóstico por imagem , Endocardite Bacteriana/diagnóstico por imagem , Fluordesoxiglucose F18 , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Compostos Radiofarmacêuticos , Estudos Retrospectivos
3.
Theranostics ; 10(7): 3263-3280, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32194867

RESUMO

Background: The LRP1 (CR9) domain and, in particular, the sequence Gly1127-Cys1140 (P3) plays a critical role in the binding and internalization of aggregated LDL (agLDL). We aimed to evaluate whether immunization with P3 reduces high-fat diet (HFD)-induced atherosclerosis. Methods: Female New Zealand White (NZW) rabbits were immunized with a primary injection and four reminder doses (R1-R4) of IrP (irrelevant peptide) or P3 conjugated to the carrier. IrP and P3-immunized rabbits were randomly divided into a normal diet group and a HFD-fed group. Anti-P3 antibody levels were determined by ELISA. Lipoprotein profile, circulating and tissue lipids, and vascular pro-inflammatory mediators were determined using standardized methods while atherosclerosis was determined by confocal microscopy studies and non-invasive imaging (PET/CT and Doppler ultrasonography). Studies treating human macrophages (hMΦ) and coronary vascular smooth muscle cells (hcVSMC) with rabbit serums were performed to ascertain the potential impact of anti-P3 Abs on the functionality of these crucial cells. Results: P3 immunization specifically induced the production of anti-P3 antibodies (Abs) and did not alter the lipoprotein profile. HFD strongly induced cholesteryl ester (CE) accumulation in the aorta of both the control and IrP groups, and their serum dose-dependently raised the intracellular CE of hMΦ and hcVSMC, promoting TNFR1 and phospho-NF-kB (p65) overexpression. These HFD pro-inflammatory effects were dramatically decreased in the aorta of P3-immunized rabbits and in hMΦ and hcVSMC exposed to the P3 rabbit serums. Microscopy studies revealed that P3 immunization reduced the percentage of lipids, macrophages, and SMCs in the arterial intima, as well as the atherosclerotic extent and lesion area in the aorta. PET/CT and Doppler ultrasonography studies showed that the average standardized uptake value (SUVmean) of the aorta and the arterial resistance index (ARI) of the carotids were more upregulated by HFD in the control and IrP groups than the P3 group. Conclusions: P3 immunization counteracts HFD-induced fatty streak formation in rabbits. The specific blockade of the LRP1 (CR9) domain with Anti-P3 Abs dramatically reduces HFD-induced intracellular CE loading and harmful coupling to pro-inflammatory signaling in the vasculature.


Assuntos
Aterosclerose/prevenção & controle , Imunização , Proteína-1 Relacionada a Receptor de Lipoproteína de Baixa Densidade/imunologia , Fragmentos de Peptídeos/imunologia , Sequência de Aminoácidos , Animais , Especificidade de Anticorpos , Aorta/citologia , Aorta/diagnóstico por imagem , Aterosclerose/sangue , Aterosclerose/diagnóstico por imagem , Aterosclerose/imunologia , Células Cultivadas , Ésteres do Colesterol/metabolismo , Vasos Coronários/citologia , Dieta Hiperlipídica , Feminino , Humanos , Lipídeos/sangue , Lipoproteínas/sangue , Proteína-1 Relacionada a Receptor de Lipoproteína de Baixa Densidade/química , Macrófagos/efeitos dos fármacos , Miócitos de Músculo Liso/efeitos dos fármacos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Domínios Proteicos , Coelhos , Distribuição Aleatória , Ultrassonografia Doppler , Resistência Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA