Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Diabetes Metab Res Rev ; 38(6): e3546, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35578575

RESUMO

AIMS: To identify clinical features and protein biomarkers associated with bladder cancer (BC) in individuals with type 2 diabetes mellitus presenting with haematuria. MATERIALS AND METHODS: Data collected from the Haematuria Biomarker (HaBio) study was used in this analysis. A matched sub-cohort of patients with type 2 diabetes and patients without diabetes was created based on age, sex, and BC diagnosis, using approximately a 1:2 fixed ratio. Randox Biochip Array Technology and ELISA were applied for measurement of 66 candidate serum and urine protein biomarkers. Hazard ratios and 95% confidence intervals were estimated by chi-squared and Wilcoxon rank sum test for clinical features and candidate protein biomarkers. Diagnostic protein biomarker models were identified using Lasso-based binominal regression analysis. RESULTS: There was no difference in BC grade, stage, and severity between individuals with type 2 diabetes and matched controls. Incidence of chronic kidney disease (CKD) was significantly higher in patients with type 2 diabetes (p = 0.008), and CKD was significantly associated with BC in patients with type 2 diabetes (p = 0.032). A biomarker model, incorporating two serum (monocyte chemoattractant protein 1 and vascular endothelial growth factor) and three urine (interleukin 6, cytokeratin 18, and cytokeratin 8) proteins, predicted incidence of BC with an Area Under the Curve (AUC) of 0.84 in individuals with type 2 diabetes. In people without diabetes, the AUC was 0.66. CONCLUSIONS: We demonstrate the potential clinical utility of a biomarker panel, which includes proteins related to BC pathogenesis and type 2 diabetes, for monitoring risk of BC in patients with type 2 diabetes. Earlier urology referral of patients with type 2 diabetes will improve outcomes for these patients. TRIAL REGISTRATION: http://www.isrctn.com/ISRCTN25823942.


Assuntos
Diabetes Mellitus Tipo 2 , Insuficiência Renal Crônica , Neoplasias da Bexiga Urinária , Biomarcadores Tumorais , Diabetes Mellitus Tipo 2/complicações , Hematúria/diagnóstico , Hematúria/etiologia , Humanos , Insuficiência Renal Crônica/complicações , Neoplasias da Bexiga Urinária/complicações , Neoplasias da Bexiga Urinária/diagnóstico , Neoplasias da Bexiga Urinária/patologia , Fator A de Crescimento do Endotélio Vascular
2.
BMC Anesthesiol ; 21(1): 143, 2021 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-33980179

RESUMO

BACKGROUND: Epidural catheters are routinely placed for many surgical procedures and to treat various pain conditions. Known complications arising from epidural catheter equipment malfunction include epidural pump failure, epidural catheter shearing, epidural catheter connector failure, epidural filter connector cracking, and loss-of-resistance syringe malfunction. Practitioners need to be aware of these potentially dangerous complications and take measures to mitigate the chances of causing significant patient harm. We report on the complete breakage of an epidural filter connector during epidural bolus administration of local anesthetic by hand with a syringe. CASE PRESENTATION: A B. Braun Perifix® epidural catheter was placed in a 73-year-old male scheduled for radical prostatectomy. During the operation, a continuous infusion of local anesthetic was administered through the epidural catheter in addition to general endotracheal anesthesia. At the conclusion of surgery and after extubation, the patient endorsed incisional pain. The epidural filter connector broke in half as a bolus of local anesthetic was administered by hand with a syringe. The local anesthetic sprayed widely throughout the room as the fragmented epidural filter connector became a projectile object that recoiled and struck the patient. CONCLUSIONS: This incident placed the patient and surrounding healthcare providers at substantial risk for injury and infection from the fractured epidural filter connector becoming a projectile object and from the local anesthetic spray. The most plausible cause of this event was from a large amount of pressure being applied to the filter connector. This may have occurred by excessive force being applied by hand to the syringe, by the presence of a clogged filter, or by the catheter being kinked or blocked proximal to the filter. Being aware of this deleterious complication and potentially modifying existing epidural bolus techniques, such as using smaller syringes with less applied force and checking all epidural components vigilantly prior to and during bolus administration, can help anesthesia providers deliver the safest possible care to patients with epidural catheters.


Assuntos
Analgesia Epidural/instrumentação , Anestésicos Locais/administração & dosagem , Catéteres/efeitos adversos , Idoso , Falha de Equipamento , Humanos , Masculino
3.
Cureus ; 14(3): e22777, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35291729

RESUMO

Statin-induced necrotizing autoimmune myopathy (SINAM) is a rare side effect in people who are taking a class of drugs called statins. Patients with SINAM will present with subacute severe symmetric proximal muscle weakness. In contrast to more common myopathies, SINAM may not spontaneously resolve with statin discontinuation. These patients may require long-term immunotherapy to limit further disease progression. In this case study, we report a 74-year-old female with SINAM who presented for radical excision of a right upper back melanoma and sentinel lymph node biopsy at an outpatient facility. An anesthetic plan was crafted with the use of a supraglottic airway device without neuromuscular blockade.

4.
A A Case Rep ; 8(8): 210-212, 2017 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-28118214

RESUMO

Postoperative nausea, vomiting, and pain present considerable concerns after reconstructive breast surgery. We present a case report of a 65-year-old woman with a history of severe postoperative nausea and vomiting, presenting for unilateral mastectomy with transverse rectus abdominis muscle flap. We performed unilateral pectoral nerve block and transverse abdominis plane block, which provided 24 hours of pain control and mitigated nausea and vomiting during the postoperative period.


Assuntos
Mamoplastia/métodos , Mastectomia/métodos , Bloqueio Nervoso/métodos , Dor Pós-Operatória/prevenção & controle , Reto do Abdome/transplante , Idoso , Anestésicos Locais/administração & dosagem , Feminino , Humanos , Náusea e Vômito Pós-Operatórios/prevenção & controle , Retalhos Cirúrgicos , Nervos Torácicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA