Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Eur J Clin Invest ; : e14209, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38597271

RESUMO

BACKGROUND: In the last few years, percutaneous LAA occlusion (LAAO) has become a plausible alternative in atrial fibrillation (AF) patients with contraindications to anticoagulation therapy. Nevertheless, the optimal antiplatelet strategy following percutaneous LAAO remains to be defined. METHODS: Studies comparing single antiplatelet therapy (SAPT) versus dual antiplatelet therapy (DAPT) following LAAO were systematically searched and screened. The outcomes of interest were ischemic stroke, device-related thrombus (DRT) and major bleeding. A random-effect meta-analysis was performed comparing outcomes in both groups. The moderator effect of baseline characteristics on outcomes was evaluated by univariate meta-regression analyses. RESULTS: Sixteen observational studies with 3255 patients treated with antiplatelet therapy (SAPT, n = 1033; DAPT, n = 2222) after LAAO were included. Mean age was 74.5 ± 8.3 years, mean CHA2DS2-VASc and HAS-BLED scores were 4.3 ± 1.5 and 3.2 ± 1.0, respectively. At a weighted mean follow-up of 12.7 months, the occurrence of stroke (RR 1.33; 95% CI 0.64-2.77; p =.44), DRT (RR 1.52; 95% CI 0.90-2.58; p =.12), and the composite of stroke and DRT (RR 1.26; 95% CI 0.67-2.37; p =.47) did not differ significantly between SAPT and DAPT groups. The rate of major bleedings was also not different between groups (RR 1.41; 95% CI 0.64-3.12; p =.39). CONCLUSIONS: Among AF patients at high bleeding risk undergoing percutaneous LAAO, a post-procedural minimalistic antiplatelet strategy with SAPT did not significantly differ from DAPT regimens regarding the rate of stroke, DRT and major bleeding.

2.
Catheter Cardiovasc Interv ; 98(4): E581-E585, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34128584

RESUMO

Spontaneous coronary artery dissection (SCAD) can lead to acute coronary syndrome and sudden cardiac death, particularly in young women. Observational data show that, in SCAD patients, both percutaneous coronary intervention and coronary artery bypass grafting seem to be hampered by higher technical complexity, lower success rates, and worse outcomes. As spontaneous healing is a common occurrence, expert consensus advices medical management of the acute phase, when feasible. We present the case of a young woman with SCAD of left anterior descending artery causing myocardial infarction with ST-segment elevation. High-anatomical complexity and unstable conditions of the patient made both medical management and immediate revascularization unfeasible options. Therefore, we decided to implant a percutaneous off-loading mechanical support device to improve coronary perfusion pressure by unloading the left ventricle and preserve cardiac function, preventing worse complications of acute myocardial infarction. This strategy was successful in stabilizing the patient, until the definitive revascularization treatment became an option.


Assuntos
Vasos Coronários , Ventrículos do Coração , Dissecação , Feminino , Humanos , Perfusão , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 97(4): E536-E543, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32584507

RESUMO

BACKGROUND: Stroke is a feared complication of transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR). OBJECTIVES: With this meta-analysis we aimed to evaluate the incidence of 30-day stroke with TAVR and SAVR focusing on its possible correlation with surgical risk. METHODS: Major electronic databases were searched for studies published between January 2002 and October 2019 reporting the rates of 30-day stroke after TAVR and SAVR. Data were pooled using fixed- and random-effects models. The primary outcome of the study was stroke rate within 30-day from TAVR or SAVR. Results were stratified according to surgical risk score (high, intermediate and low). RESULTS: A total of 23 studies were identified (TAVR: 14,589 patients; SAVR: 11,681 patients). Regardless of the model used, in the overall population TAVR was associated with a significant reduction in the risk of stroke compared with SAVR (fixed effect: OR 0.78, 95% CI 0.66-0.92, p = .003; random-effects: OR 0.80, 95% CI 0.64-1.00, p = .045). Rates of 30-day stroke after TAVR and SAVR were not significantly different in the high- (OR 1.01, 95% CI 0.44-1.98, p = .105) and intermediate-risk groups (OR 0.92, 95% CI 0.63-1.36, p = .319), while low-risk patients had a lower rate of 30-day stroke after TAVR than SAVR (OR 0.65, 95% CI 0.50-0.83, p < .001). Meta-regression showed a significant association between surgical risk score and 30-day stroke rate (p = .007). CONCLUSIONS: TAVR is associated with a lower risk of 30-day stroke compared with SAVR, mainly as a result of the significant advantage observed in patients at low surgical risk.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 96(2): 471-472, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32797741

RESUMO

Transfemoral (TF) transcatheter aortic valve replacement (TAVR) has evolved dramatically. Improvements in technique, devices, operator's experience, and patient selection have resulted in markedly lower rates of procedural complications, thus allowing further technical simplification at every step of the procedure. Implementing a minimalist approach for TF TAVR (including transradial secondary access, angio-guidewire-ultrasound guidance for femoral puncture, and left ventricle guidewire pacing) may improve outcomes and reduce complications without compromising patient safety in contemporary clinical practice. Although this simplified approach is applicable for most patients undergoing TF TAVR, careful patient selection remains of paramount importance.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/diagnóstico por imagem , Humanos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 95(5): 991-992, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32294329

RESUMO

Transcatheter aortic valve replacement (TAVR) patients given pacemakers operating in mandatory DDD mode had more ventricular pacing, heart failure hospitalization, and mortality compared with AAI-DDD or VVI modes. AV conduction disturbances are often transient after TAVR. Minimizing ventricular pacing where possible avoids the risk of pacemaker-induced cardiomyopathy. Pacemaker specialists should be consulted for any TAVR patient with mild rhythm abnormalities given the high incidence of AV block. Careful stratification of patients with conduction disturbances during TAVR may help identify the patients who will require an early permanent pacemaker implantation strategy.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Estimulação Cardíaca Artificial , Humanos , Doença Iatrogênica , Fatores de Risco , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 95(4): 817-818, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32159294

RESUMO

Surgical treatment is the gold standard for pure aortic regurgitation (AR). In this study, transcatheter aortic valve replacement (TAVR) appears to be a promising option for inoperable/high-risk patients suffering pure AR. Long-term results and specific patient-level data are needed to better clarify the role of TAVR in pure AR treatment.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Alemanha , Humanos , Fatores de Risco , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 96(5): E535-E541, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31912968

RESUMO

BACKGROUND: Incidence of coronary access (CA) after transcatheter aortic valve replacement (TAVR) at long-term follow-up remains unknown. CA and percutaneous coronary intervention (PCI) after TAVR might present technical challenges, particularly with supra-annular devices. METHODS: Patients undergoing CA after being treated with TAVR at our institution were included in the study. Coronary interventions for coronary obstruction during TAVR procedure were excluded. Incidence, feasibility and outcomes of CA after TAVR were analyzed. RESULTS: Out of 912 patients aged 80 ± 7 years treated with TAVR at our institution between 2007 and 2018, 48 (5.3%) underwent CA at a median follow up of 769 [363-1,471] days. Twenty-one had received a SAPIEN XT, 15 a SAPIEN 3, 6 Corevalve, 2 Evolut Pro, 2 JenaValve, and 2 Lotus valve. PCI was indicated in 26 (54%) cases. Seventeen (35%) procedures were performed for acute coronary syndromes (ACS). Independent predictors of CA after TAVR were younger age, previous PCI, and CABG. CA of both vessels was feasible in all patients with an intra-annular device, while the right coronary artery was not engaged in two patients with a supra-annular valve. PCI was successful in all but one case. All-cause mortality was similar between patients needing CA for ACS and those who had other clinical indications. CONCLUSIONS: In this high-risk AS population, incidence of CA after TAVR at long-term follow-up was rather low. CA and PCI were safe and successful in most cases, with a lower rate of selective CA for supra-annular devices.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Angiografia Coronária , Estenose Coronária/diagnóstico , Estenose Coronária/terapia , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Angiografia Coronária/efeitos adversos , Angiografia Coronária/mortalidade , Estenose Coronária/mortalidade , Estudos de Viabilidade , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 95(5): 993-1000, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-31099970

RESUMO

BACKGROUND: Peripheral arterial disease (PAD) plays a decisive role in the preinterventional selection process of the optimal vascular access site in patients undergoing transcatheter aortic valve implantation (TAVI). However, the impact of PAD on mortality and vascular complications (VCs) in TAVI-treated patients remains unclear. Accordingly, we aimed to assess the outcomes of patients with and without PAD undergoing TAVI, by performing a meta-regression analysis. METHODS: Studies published between January 2002 and March 2018 and reporting outcomes according to the presence of PAD in TAVI patients were identified. Outcome measures analyzed were short-, mid- and long-term mortality, and peri-procedural VC. The interaction between sheath size and PAD on outcomes was also assessed. RESULTS: A total of 26 studies (68,581 TAVI patients, of whom 17,326 with preprocedural PAD) were included in the analysis. Patients with PAD had higher risk of mortality at short- (HR 1.36, 95% confidence interval [CI] 1.13-1.63, p = .0009), mid- (HR 1.18, 95% CI 1.08-1.30, p = .0005), and long-term (HR 1.36, 95% CI 1.24-1.48, p < .0001) follow-up, and higher risk of VC (RR 1.55, 95% CI 1.27; 1.89, p < .0001). Moreover, the adoption of smaller sheaths during TAVI procedures was associated with fewer VC both in PAD and non-PAD patients, but the latter group had a more pronounced benefit. CONCLUSIONS: Patients with pre-existent PAD are at increased risk of all-cause mortality and VC after TAVI. The adoption of smaller sheaths during the procedure seems to be associated with fewer peri-procedural VC both in PAD and non-PAD patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Doença Arterial Periférica/fisiopatologia , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Hemodinâmica , Humanos , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/mortalidade , Complicações Pós-Operatórias/epidemiologia , Recuperação de Função Fisiológica , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 30(6): 854-864, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30827041

RESUMO

INTRODUCTION: The recently developed second-generation subcutaneous implantable cardioverter defibrillator (S-ICD) and the intermuscular two-incision implantation technique demonstrate potential favorable features that reduce inappropriate shocks and complications. However, data concerning large patient populations are lacking. The aim of this multicentre prospective study was to evaluate the safety and outcome of second-generation S-ICD using the intermuscular two-incision technique in a large population study. METHODS AND RESULTS: The study population included 101 consecutive patients (75% male; mean age, 45 ± 13 years) who received second-generation S-ICD (EMBLEM; Boston Scientific, Marlborough, MA) implantation using the intermuscular two-incision technique as an alternative to the standard implantation technique. Twenty nine (29%) patients were implanted for secondary prevention. Twenty four (24%) patients had a previously implanted transvenous ICD. All patients were implanted without any procedure-related complications. Defibrillation testing was performed in 80 (79%) patients, and ventricular tachycardia was successfully converted at less than or equal to 65 J in 98.75% (79/80) of patients without pulse generator adjustments. During a median follow-up of 21 ± 10 months, no complications requiring surgical revision or local or systemic device-related infections were observed. Ten patients (9.9%) received appropriate and successful shocks for ventricular arrhythmias. Three (2.9%) patients experienced inappropriate shocks due to oversensing the cardiac signal (n = 1), noncardiac signal (n = 1), and a combination of both cardiac and noncardiac signals (n = 1), with one patient requiring device explantation. No patients required device explantation due to antitachycardia pacing indications. CONCLUSIONS: According to our multicentre study, second-generation S-ICD implanted with the intermuscular two-incision technique is an available safe combination and appears to be associated with a low risk of complications, such as inappropriate shocks.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Implantação de Prótese/instrumentação , Prevenção Secundária/instrumentação , Potenciais de Ação , Adolescente , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Remoção de Dispositivo , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Implantação de Prótese/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
12.
Heart Lung Circ ; 24(4): e56-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25499594

RESUMO

A 66 year-old female presented with a refractory hypoxaemia in association with an isolated paralysis of the right hemidiaphragm. Transoesophageal echocardiography (TEE) with both colour Doppler and bubble test demonstrated a significant patent foramen ovale (PFO)-mediated right-to-left shunt (RTLS) without an increased interatrial pressure gradient. The PFO was urgently closed by deployment of an AMPLATZER(®) occluder device, resulting in complete recovery of the arterial oxygen saturation and patient's symptoms. As noted on TEE, the RTLS was due to redirection of blood flow from the inferior vena cava directly through the PFO secondary to distortion of the cardiac anatomy by right hemidiaphragmatic paralysis.


Assuntos
Diafragma , Forame Oval Patente , Paralisia , Idoso , Diafragma/diagnóstico por imagem , Diafragma/fisiopatologia , Diafragma/cirurgia , Ecocardiografia Transesofagiana , Feminino , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/fisiopatologia , Forame Oval Patente/cirurgia , Humanos , Paralisia/complicações , Paralisia/diagnóstico por imagem , Paralisia/fisiopatologia , Paralisia/cirurgia
14.
G Ital Cardiol (Rome) ; 25(6): 23-37, 2024 Jun.
Artigo em Italiano | MEDLINE | ID: mdl-38912744

RESUMO

STENT PANORAMA is a project carried out by the Young Interventional Cardiologists of Triveneto coordinated by the Italian Society of Interventional Cardiology (GISE) Veneto delegation. The project includes two parts: the first, here reported, is aimed at describing in a standardized and easily usable way the main technological characteristics of the latest generation of the drug eluting stents (DES) that are most widely used in the Italian cath-labs. The second, to follow, will aim to summarize the main scientific evidence regarding the performance of individual devices with particular reference to subgroups of clinical interest. The ambitious goal of the STENT PANORAMA working group is to provide the interventional cardiologist with a thorough, practical, and functional knowledge of the DES currently available in the modern therapeutic armamentarium to promote a therapeutic strategy tailored to the patient.


Assuntos
Stents Farmacológicos , Humanos , Itália , Intervenção Coronária Percutânea/métodos , Desenho de Prótese , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/cirurgia
15.
Am J Cardiol ; 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38729335

RESUMO

The long-term safety and effectiveness of transcatheter aortic valve replacement (TAVR) compared with surgical aortic valve replacement (SAVR) in low surgical risk has not been evaluated in a pooled analysis. An electronic database search was conducted for randomized controlled trials with a maximal 5 years clinical and echocardiographic follow-up including low surgical risk patients who underwent TAVR or SAVR. We calculated odds ratio (OR) and 95% confidence intervals (CIs) using a random-effects model. Subgroups analysis was performed for permanent pacemaker implantation and paravalvular leaks. Three randomized controlled trials were included with a total of 2,611 low surgical risk patients (Society of Thoracic Surgeons score <4%). Compared with SAVR, the TAVR group had similar rates of all-cause mortality (OR 0.94,95% CI 0.65 to 1.37, p = 0.75) and disabling stroke (OR 0.84, 95% CI 0.52 to 1.36, p = 0.48). No significant differences were registered in the TAVR group in terms of major cardiovascular events (OR 0.96, 95% CI 0.67 to 1.38, p = 0.83), myocardial infarction (OR 0.69, 95% CI 0.34 to 1.40, p = 0.31), valve thrombosis (OR 3.11, 95% CI 0.29 to 33.47, p = 0.35), endocarditis (OR 0.71,95% CI 0.35 to 1.48, p = 0.36), aortic valve reintervention (OR 0.93, 95% CI 0.52 to 1.66, p = 0.80), and rehospitalization (OR 0.80, 95% CI 0.52 to 1.02, p = 0.07) compared with SAVR. However, TAVR patients had a higher risk of paravalvular leaks (OR 8.21, 95% CI 4.18 to 16.14, p <0.00001), but lower rates of new-onset atrial fibrillation (OR 0.27,95% CI 0.17 to 0.30, p <0.0001). The rates of permanent pacemaker implantation were comparable from 1 year up to a maximum of 5 years (OR 1.32, 95% CI 0.88 to 1.97, p = 0.18). Lastly, TAVR had a greater effective orifice area (0.10 cm2/m2, 95% CI 0.05 to 0.15, p = 0.0001), but similar transvalvular mean gradients (0.60, 95% CI 3.94 to 2.73, p = 0.72). In conclusion, TAVR patients had similar long-term outcomes compared with SAVR, except for an elevated risk of paravalvular leaks in the TAVR group and increased rates of atrial fibrillation in the SAVR cohort.

16.
EuroIntervention ; 20(8): e504-e510, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38629420

RESUMO

The treatment of coronary artery disease (CAD) in patients with severe aortic valve stenosis (AVS) eligible for transcatheter aortic valve implantation (TAVI) is not supported by clinical evidence, and the role of physiology over anatomy as well as the timing of coronary intervention are not defined. FAITAVI (ClinicalTrials.gov: NCT03360591) is a nationwide prospective, open-label, multicentre, randomised controlled study comparing the angiography-guided versus the physiology-guided coronary revascularisation strategy in patients with combined significant CAD and severe AVS undergoing TAVI. Significant CAD will be defined as coronary stenosis ≥50%, as assessed by visual estimation in vessels ≥2.5 mm. Physiology will be tested by fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR). The study will be conducted at 15 sites in Italy. In the angiography arm, percutaneous coronary intervention (PCI) will be performed either before TAVI, during the TAVI procedure - before or after the valve implantation - or within 1 month±5 days of the valve implantation, left to the operator's decision. In the physiology arm, FFR and iFR will be performed before TAVI, and PCI will be indicated for FFR ≤0.80, otherwise the intervention will be deferred. In case of borderline values (0.81-0.85), FFR and iFR will be repeated after TAVI, with PCI performed when needed. With a sample size of 320 patients, the study is powered to evaluate the primary endpoint (a composite of death, myocardial infarction, stroke, major bleeding, or ischaemia-driven target vessel revascularisation). TAVI indication, strategy and medical treatment will be the same in both groups. After discharge, patients will be contacted at 1, 6, 12 and 24 months after the procedure to assess their general clinical status, and at 12 months for the occurrence of events included in the primary and secondary endpoints. FAITAVI is the first randomised clinical trial to investigate "optimal" percutaneous coronary intervention associated with TAVI in patients with severe AVS and CAD.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
17.
Artigo em Inglês | MEDLINE | ID: mdl-38749449

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: To identify the incidence, predictors, and clinical outcomes of PVR following TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with severe Sievers type 1 BAV stenosis undergoing TAVR with current generation transcatheter heart valves (THVs) in 24 international centres were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAE), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%): mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were larger virtual raphe ring (VRR) perimeter (ORadj 1.07, 95% CI 1.02-1.13), severe annular or left ventricular outflow tract (LVOT) calcification (ORadj 5.21, 95% CI 1.45-18.77), self-expanding valve (ORadj 9.01, 95% CI 2.09-38.86), and intentional supra-annular THV positioning (ORadj 3.31, 95% CI 1.04-10.54). At a median follow-up of 1.3 [IQR 0.5-2.4] years, moderate or severe PVR was associated with an increased risk of MAE (HRadj 2.52, 95% CI 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAE during follow-up.

18.
Heart ; 110(1): 27-34, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37414524

RESUMO

OBJECTIVE: The European Society of Cardiology guidelines have recently defined new cut-offs for pulmonary hypertension (PH) and pulmonary vasculature resistance (PVR; median pulmonary artery pressure (mPAP) >20 instead of 25 mm Hg and PVR >2 instead of 3 Wood unit). The prognostic value of this updated classification after transcatheter aortic valve implantation (TAVI) is unknown. METHODS: 579 consecutive patients treated by TAVI with preprocedural right heart catheterisation evaluation were included. Patients were grouped as: (1) no PH, (2) isolated precapillary/combined (I-PreC/Co) PH and (3) isolated postcapillary PH (I-PoC). All-cause death, cardiovascular death and hospitalisations for heart failure (HF) were evaluated at follow-up. We also analysed the prognostic role of residual postprocedural PH. RESULTS: Out of 579 patients, 299 (52%) had PH according to the new criteria compared with 185 (32%) according to the previous ones. Overall median age was 82 years, while 55.3% patients were male. Patients with PH were more frequently diagnosed with chronic obstructive pulmonary disease and atrial fibrillation and were characterised by higher surgical risk as compared with patients without PH.At a median follow-up of 2.9 years, the presence of PH according to previous definition was associated with worse survival (p<0.001) and HF hospitalisation (p=0.002) rates, irrespective of PVR values. With newer cut-offs, PH was associated with worse outcomes only in patients with increased PVR, while no differences were found between patients with PH and normal PVR values and those without PH. Postprocedural mPAP normalisation was observed in 45% of the cases, but it was associated with improved long-term survival only in the I-PoC PH group. CONCLUSIONS: New ESC PH cut-offs increased the number of PH diagnoses. The presence of PH, particularly in the setting of increased PVR, identify patients at higher risk for postprocedural mortality and rehospitalisation. Normalisation of PH was associated with better survival only in I-PoC group.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Hipertensão Pulmonar , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Prognóstico , Resultado do Tratamento , Fatores de Risco
19.
Circ Cardiovasc Interv ; 15(2): e011045, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35167332

RESUMO

BACKGROUND: Coronary access (CA) after transcatheter aortic valve replacement (TAVR) with supra-annular transcatheter heart valves (THV) can be challenging. Specific Evolut R/Pro and Acurate Neo THVs orientations are associated with reduced neo-commissure overlap with coronary ostia, while SAPIEN 3 THV cannot be oriented. With the ALIGN-ACCESS study (TAVR With Commissural Alignment Followed by Coronary Access), we investigated the impact of commissural alignment on the feasibility of CA after TAVR. METHODS: We performed coronary angiography after TAVR with intra-annular SAPIEN 3, supra-annular Evolut R/Pro, and Acurate Neo THVs in 206 patients. Evolut THVs were implanted aiming for commissure alignment. Alignment of Acurate Neo was retrospectively assessed in 36, intentionally attempted in 26 cases. The primary end point was the rate of unfeasible and nonselective CA after TAVR. RESULTS: Thirty-eight percent of patients received SAPIEN 3, 31.1% Evolut Pro/R, 30.1% Acurate Neo THV. Final valve orientation was favorable to commissural alignment in 85.9% of Evolut and 69.4% of Acurate Neo cases (with intentional alignment successful in 88.5%). Selective CA was higher for SAPIEN 3 than for aligned and misaligned supra-annular THVs (95% versus 71% versus 46%, P<0.001). Cannulation of at least one coronary was unfeasible with 11% misaligned supra-annular, 3% aligned supra-annular, and 0% SAPIEN 3 THVs. Independent predictors of unfeasible/nonselective CA were implantation of a misaligned supra-annular THV (odds ratio, 4.59 [95% CI, 1.81-11.61]; P<0.01), sinus of Valsalva height (odds ratio, 0.83 [95% CI, 0.7-0.98]; P=0.03), and THV-sinus of Valsalva relation (odds ratio, 1.06 [95% CI, 1.02-1.1]; P<0.01). CONCLUSIONS: Commissural alignment improves the rate of selective CA after TAVR with supra-annular THVs. Nevertheless, aligned supra-annular THVs carry higher risk of unfeasible/nonselective CA than SAPIEN 3. Patients with a misaligned supra-annular THV, low sinus of Valsalva, and higher THV-sinus of Valsalva relation are at highest risk of impaired CA after TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
Front Cardiovasc Med ; 9: 832242, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35295263

RESUMO

Backgrounds: Among vascular closure devices (VCDs), the novel collagen plug-based MANTA VCD is the first designed for large bore percutaneous access. We aimed to assess the features and predictors of access-site vascular complications in an unselected trans-femoral transcatheter aortic valve replacement (TF-TAVR) population. Methods: Patients undergoing large bore arteriotomy closure with 18F MANTA VCD following TF-TAVR at a large tertiary care center from September 2019 to January 2021 were prospectively analyzed. Primary Outcome was the MANTA VCD access-site-related complications according to Valve Academic Research Consortium-3 (VARC) definitions. Its incidence and predictors were evaluated. Results: Eighty-eight patients (median age 82 years, 48% male, 3.3 median Society of Thoracic Surgeons score) undergoing TF-TAVR were included, mostly (63%) treated with a self-expandable device and with outer diameter sizes varied from 18F to 24-F. MANTA VCD technical success rate was 98%, while 10 patients (11%) experienced MANTA VCD access-site vascular complications which included 8% of minor complications and only to 2% of major events resulting in VARC type ≥2 bleeding. Vessel occlusion/stenosis (60%), perforation (20%), and pseudoaneurysm/dissection/hematoma (20%) occurred, but all were managed without surgical treatment. Independent predictors of failure were age (p = 0.04), minimum common femoral artery diameter (CFA) (p < 0.01), sheath-to-femoral-artery ratio (SFAR) (p < 0.01), and a lower puncture height (p = 0.03). A CFA diameter <7.1 mm with a SFAR threshold of 1.01 were associated with VCD failure. Conclusions: In a more comers TF-TAVR population, MANTA VCD was associated with reassuring rates of technical success and major access-site vascular complications. Avoiding lower vessel size and less puncture site distance to CFA bifurcation might further improve outcomes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA