Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 33(3): 458-463, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34968010

RESUMO

BACKGROUND: The rate of left ventricular (LV) lead displacement after cardiac resynchronization therapy (CRT) remains high despite improvements in lead technology. In 2017, a novel quadripolar lead with active fixation technology became available in the UK. METHODS: This was a retrospective, observational study analyzing device complications in 476 consecutive patients undergoing successful first-time implantation of a CRT device at a tertiary center from 2017 to 2020. RESULTS: Both active (n = 135) and passive fixation (n = 341) quadripolar leads had similar success rates for implantation (99.3% vs. 98.8%, p = 1.00), although the pacing threshold (0.89 [0.60-1.25] vs. 1.00 [0.70-1.60] V, p = .01) and lead impedance (632 [552-794] vs. 730 [636-862] Ohms, p < .0001) were significantly lower for the active fixation lead. Patients receiving an active fixation lead had a reduced incidence of lead displacement at 6 months (0.74% vs. 4.69%, p = .036). There was no significant difference in the rate of right atrial (RA) and right ventricular (RV) lead displacement between the two groups (RA: 1.48% vs. 1.17%, p = .68; RV: 2.22% vs. 1.76%, p = .72). Reprogramming the LV lead after displacement was unsuccessful in most cases (successful reprogramming: Active fix = 0/1, Passive fix = 1/16) therefore nearly all patients required a repeat procedure. As a result, the rate of intervention within 6 months for lead displacement was significantly lower when patients were implanted with the active fixation lead (0.74% vs. 4.40%, p = .049). CONCLUSION: The novel active fixation lead in our study has a lower incidence of lead displacement and re-intervention compared to conventional quadripolar leads for CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca , Eletrodos Implantados/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos , Resultado do Tratamento
2.
Acta Paediatr ; 111(12): 2291-2298, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36017578

RESUMO

AIM: This study was undertaken to specifically identify challenges associated with the popular single-family room (SFR) design in our new neonatal intensive care unit (NICU), so as to reap the full benefits of this architectural model. METHODS: A survey was sent to all 223, newly recruited staff on our NICU. Questions explored staff perceptions of family experience, safety and staff's experience of the SFR in comparison with the open bay model. RESULTS: We obtained a response rate of 66%. Most staff perceived SFR as having a positive impact on communication with families, privacy, feasibility for skin-to-skin contact, reduction in noise levels and family access to their baby. There were however concerns raised about patient safety and isolation of staff and families in the SFR architecture. Lack of opportunities to leave the patient room for breaks and increased physical demands were highlighted. Staff also felt physically and emotionally less well supported. CONCLUSION: Whilst the SFR configuration was felt to be beneficial for infants and families, staff shared their perceived concerns regarding infant safety and isolation and staff satisfaction, and implied modifications to workflows. The survey findings resulted in re-organisation of our staff numbers and communication systems and further facilitation of parent interactions in order to optimise benefits of SFR design.


Assuntos
Unidades de Terapia Intensiva Neonatal , Quartos de Pacientes , Recém-Nascido , Lactente , Humanos , Pais/psicologia , Inquéritos e Questionários , Comunicação
4.
Eur J Heart Fail ; 26(2): 302-310, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38152863

RESUMO

AIM: Heart failure with preserved ejection fraction (HFpEF) remains under-diagnosed in clinical practice despite accounting for nearly half of all heart failure (HF) cases. Accurate and timely diagnosis of HFpEF is crucial for proper patient management and treatment. In this study, we explored the potential of natural language processing (NLP) to improve the detection and diagnosis of HFpEF according to the European Society of Cardiology (ESC) diagnostic criteria. METHODS AND RESULTS: In a retrospective cohort study, we used an NLP pipeline applied to the electronic health record (EHR) to identify patients with a clinical diagnosis of HF between 2010 and 2022. We collected demographic, clinical, echocardiographic and outcome data from the EHR. Patients were categorized according to the left ventricular ejection fraction (LVEF). Those with LVEF ≥50% were further categorized based on whether they had a clinician-assigned diagnosis of HFpEF and if not, whether they met the ESC diagnostic criteria. Results were validated in a second, independent centre. We identified 8606 patients with HF. Of 3727 consecutive patients with HF and LVEF ≥50% on echocardiogram, only 8.3% had a clinician-assigned diagnosis of HFpEF, while 75.4% met ESC criteria but did not have a formal diagnosis of HFpEF. Patients with confirmed HFpEF were hospitalized more frequently; however the ESC criteria group had a higher 5-year mortality, despite being less comorbid and experiencing fewer acute cardiovascular events. CONCLUSIONS: This study demonstrates that patients with undiagnosed HFpEF are an at-risk group with high mortality. It is possible to use NLP methods to identify likely HFpEF patients from EHR data who would likely then benefit from expert clinical review and complement the use of diagnostic algorithms.


Assuntos
Insuficiência Cardíaca , Humanos , Volume Sistólico , Função Ventricular Esquerda , Inteligência Artificial , Estudos Retrospectivos , Prognóstico
5.
Intest Res ; 16(2): 209-215, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29743833

RESUMO

Faecal microbiota transplantation (FMT) has recently re-emerged as a viable therapeutic option for colonic disorders. Its efficacy has been proved in the treatment of Clostridium difficile infection which has encouraged research into the use of FMT for other disorders involving gut dysbiosis, such as ulcerative colitis (UC), a chronic inflammatory disease characterized by relapsing and remitting colonic inflammation. Although the FMT protocol for C. difficile treatment is well established, there are numerous additional factors to consider when applying FMT to treat inflammatory diseases. Various studies have attempted to address these factors but technical inconsistency between reports has resulted in a failure to achieve clinically significant findings. Case reports of FMT in UC have shown favorable outcomes yet demonstrating these effects on a larger scale has proved difficult. The following review aims to explore these issues and to analyze why they may be hindering the progression of FMT therapy in UC.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA