Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Infect Dev Ctries ; 18(6): 851-861, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-38990988

RESUMO

INTRODUCTION: In Senegal, molecular diagnosis was widely used for the detection and management of COVID-19 patients. However, genomic surveillance was very limited in the public sector. This study aimed to share the experience of a Senegalese public sector laboratory in response to the COVID-19 pandemic, and to describe the distribution of variants circulating in 2020 and 2021. METHODOLOGY: From July 2020 to December 2021, SARS-CoV-2 qRT-PCR was performed on nasopharyngeal samples from travelers and symptomatic patients at the Bacteriology and Virology Laboratory (LBV) of the Aristide le Dantec University Teaching Hospital. Samples with a cycle threshold (Ct) ≤ 30 were selected for whole-genome sequencing (WGS) using the Nanopore technology. In-house scripts were developed to study the spatial and temporal distribution of SARS-CoV-2 variants in Senegal, using our sequences and those retrieved from the GISAID database. RESULTS: Of 8,207 patients or travelers screened for SARS-CoV-2, 970 (11.8%) were positive and 386 had a Ct ≤ 30. WGS was performed on 133 samples. Concomitantly with high-quality sequences deposited in the GISAID database covering nine cities in Senegal in 2020 and 2021 (n = 1,539), we observed a high circulation of the 20A (B.1, B.1.416 and B.1.620) and 20B (B.1.1.420) lineages in 2020, while most of the samples belonged to Delta variants (AY34 and AY.34.1, 22%) in 2021. CONCLUSIONS: Despite its late involvement, COVID-19 diagnosis was routinely performed in LBV, but genomic characterization remained challenging. The genomic diversity of SARS-CoV-2 strains in Senegal reflected that observed worldwide during the first waves of the pandemic.


Assuntos
COVID-19 , Genoma Viral , SARS-CoV-2 , Humanos , Senegal/epidemiologia , COVID-19/epidemiologia , COVID-19/virologia , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Sequenciamento Completo do Genoma , Epidemiologia Molecular , Nasofaringe/virologia , Adulto , Masculino , Feminino , Filogenia , Pessoa de Meia-Idade
2.
J Virol Methods ; 324: 114872, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38128833

RESUMO

Point-of-Care for HIV viral RNA quantification seems to be a complementary strategy to the existing conventional systems. This study evaluated the performance of the m-PIMA™ HIV1/2 Viral Load for the quantification of both HIV-1 and HIV-2 RNA viral load. A total of 555 HIV-1 and 90 HIV-2 samples previously tested by Abbott RealTime HIV-1 (Abbott, Chicago, USA) and Generic HIV-2® Charge virale (Biocentric, France) were tested using the m-PIMA™ HIV1/2 Viral Load at the HIV National Reference lab in Senegal. For HIV-1, Pearson correlation and Bland-Altman plots showed a coefficient r = 0.97 and a bias of -0.11 log10 copies/ml (95% confidence interval [CI]: -0.086 to -0.133 log10 copies/ml) for the m-PIMA™ HIV1/2 Viral Load, respectively. Sensitivity and specificity at 3 log10 copies/ml (threshold of virological failure) were 93.6% (95%[CI]: 91.5% to 95.6%) and 99.1% (95%[CI]: 98.3% to 99.9%), respectively. For HIV-2, a correlation of r = 0.95 was also noted with a bias of - 0.229 log10 copies/ml (95%[CI]: -0.161 to -0.297 log10 copies/ml). Sensitivity and specificity at 3 log10 copies/ml were 97.6% (95%[CI]: 94.3% to 100%) and 93.9% (95%[CI]: 88.9% to 98.8%), respectively. These results confirmed that m-PIMA™ HIV1/2 VL could be a good alternative for HIV-1 and HIV-2 viral load testing in decentralized settings in Senegal.


Assuntos
Infecções por HIV , HIV-1 , Humanos , HIV-1/genética , HIV-2/genética , Infecções por HIV/diagnóstico , Carga Viral/métodos , Sensibilidade e Especificidade , África Ocidental , RNA Viral/genética
3.
Pan Afr Med J ; 42: 136, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36060855

RESUMO

Introduction: the introduction of the point-of-care in HIV-1 viral load quantification appears to be a complementary strategy to the existing conventional system of the acceleration plan for the achievement of the three 90s in Senegal. The objective of this study was to evaluate the performance of the Xpert® HIV-1 viral load in the context of circulation of non-B, non-C subtypes. Methods: two hundred samples, were tested on Xpert® HIV-1 Viral Load using 1 ml of plasma in comparison to 600 µl on Abbott Real-time HIV-1 assay. The difference between viral load values was considered significant for Dlog <0.5 log copies/ml. Results: a good correlation (r=0.985) was noted and confirmed using passing-bablok regression (slope 1.048; 95% CI: 1.036 to 1.069) for 188 samples with samples. A mean difference of 0.0075 log10 copies/ml for a 95% confidence interval (CI) of 0.002 log10 copies/ml to 0.013 log10 copies/ml was obtained. Sensitivity and specificity were respectively 93.6% and 93.5% at the threshold of 1.6 log10 copies/ml and 100% and 99% at the threshold of 3.0 log10 copies/ml. Conclusion: these results show that Xpert® HIV-1 Viral Load has excellent performance. In Senegal, and can be used for HIV viral load monitoring.


Assuntos
Infecções por HIV , HIV-1 , Infecções por HIV/diagnóstico , HIV-1/genética , Humanos , RNA Viral , Senegal , Carga Viral
4.
Pan Afr Med J ; 43: 42, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36523274

RESUMO

Introduction: early infant diagnosis (EID) is crucial in the prevention of mother to child transmission (PMTCT) of human immunodeficiency virus (HIV) and is an essential component for the elimination of HIV. EID can be strengthened in resource-limited countries by the introduction and the roll out of real-time polymerase chain reaction (PCR) technologies via point-of-care (POC) devices which improves treatment in remote areas and reduces turnaround time for clinicians and patients to receive results and linkage to care. The objective of this study was to evaluate the performance of Xpert® HIV-1 Qual Assay (Cepheid) and m-PIMA™ HIV 1/2 Detect (ABBOTT) for EID of HIV-1 and HIV-2. Methods: the performance of the Xpert® HIV-1 qual device was evaluated with 192 samples including 100 dried blood spot (DBS) samples from the National Reference Laboratory biobank (71 negative and 29 positive samples) and an additional 92 whole blood samples collected from infants from neonatal departments. These infants from seven treatment centers in the Dakar region were born to mothers infected with HIV-1 (n=91), HIV-2 (n= 8) or HIV-1/2 (n=1). The m-PIMA™ HIV 1/2 detect assay was evaluated on whole blood samples (n=100) with 92 HIV-1 samples and 8 HIV-2 samples from children born to HIV-infected mothers. The Cobas AmpliPreP/Cobas TaqMan (CAP/CTM) platform from Roche Diagnostic Laboratories was used as a reference for HIV-1 diagnosis and the Generic HIV-2 Viral Load Assay (Biocentric) was used as a reference for HIV-2 diagnosis. Performance was evaluated by calculating sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV) and Cohen's kappa coefficient. Results: for HIV-1 detection on GeneXpert and m-PIMA, no discordance was found on the samples tested, i.e. a sensitivity of 100% (95% CI: 93.9-100%), a specificity of 100% (95% CI: 97.5-100%), a positive predictive value (PPV) of 100% (95% CI: 93.9-100%) and a negative predictive value (NPV) of 100% (95% CI: 97.5-100%). Agreement with Cobas AmpliPrep/Cobas TaqMan (CAP/CTM) was 100% with a Kappa coefficient of 1 (p<0.001, 95% CI) for both techniques. Similarly, the comparison between m-PIMA and generic biocentric for the detection of HIV-2 on the 8 samples tested showed perfect agreement. Conclusion: these results confirm the excellent performance of the Xpert® HIV-1 qual and m-PIMA™ HIV1/2 detect tests for the detection of HIV-1 and HIV-2 and encourage the extension of POC tests to improve access to EID in Senegal.


Assuntos
Infecções por HIV , HIV-1 , Lactente , Recém-Nascido , Criança , Humanos , Feminino , HIV-1/genética , HIV-2 , Iodeto de Potássio , Sistemas Automatizados de Assistência Junto ao Leito , Senegal , Transmissão Vertical de Doenças Infecciosas , Sensibilidade e Especificidade , Diagnóstico Precoce , Carga Viral , RNA Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA