Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 25(1): 101, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38287387

RESUMO

BACKGROUND: The hip joint capsule is an essential component of hip joint function and stability, and its thickness is closely associated with certain medical conditions, surgical outcomes, and rehabilitation treatments. Currently, in clinical practice, hip joint capsule thickness is predominantly measured using magnetic resonance imaging (MRI), with limited utilization of ultrasound examinations for this purpose. METHODS: We retrospectively evaluated patients who visited our Sports Medicine Department between February 2017 and March 2023 and underwent both hip joint MRI and ultrasound imaging on the same side. All patients had undergone preoperative hip joint MRI and ultrasound examinations, with the time gap between the two examinations not exceeding three months. Measurements of hip joint capsule thickness were taken on both MRI and ultrasound images for the same patients to analyze their consistency. Additionally, we measured the alpha angle, lateral center-edge angle, acetabular anteversion angle, and femoral anteversion angle of the patients' hip joints and analyzed their correlation with hip joint capsule thickness measure by ultrasound. RESULTS: A total of 307 patients were included in this study, with hip joint capsule thickness measured by MRI and ultrasound being 5.0 ± 1.2 mm and 5.0 ± 1.5 mm, respectively. The Bland-Altman analysis demonstrates good agreement or consistency. The paired t-test resulted in a p-value of 0.708, indicating no significant statistical difference between the two methods. The correlation analysis between acetabular anteversion angle and ultrasound-measured capsule thickness yielded a p-value of 0.043, indicating acetabular anteversion angle and capsular thickness may have negative correlation. CONCLUSIONS: The measurements of joint capsule thickness obtained through ultrasound and MRI showed good consistency, suggesting that ultrasound can be used in clinical practice as a replacement for MRI in measuring hip joint capsule thickness. There was a significant correlation between acetabular anteversion angle and hip joint capsule thickness, indicating potential for further research in this area.


Assuntos
Acetábulo , Articulação do Quadril , Humanos , Estudos Retrospectivos , Articulação do Quadril/cirurgia , Acetábulo/cirurgia , Cápsula Articular/diagnóstico por imagem , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA