Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 20(22)2020 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-33233742

RESUMO

Physiological pressure measurement is one of the most common applications of sensors in healthcare. Particularly, continuous pressure monitoring provides key information for early diagnosis, patient-specific treatment, and preventive healthcare. This paper presents a thin-film flexible wireless pressure sensor for continuous pressure measurement in a wide range of medical applications but mainly focused on interface pressure monitoring during compression therapy to treat venous insufficiency. The sensor is based on a pressure-dependent capacitor (C) and printed inductive coil (L) that form an inductor-capacitor (LC) resonant circuit. A matched reader coil provides an excellent coupling at the fundamental resonance frequency of the sensor. Considering varying requirements of venous ulceration, two versions of the sensor, with different sizes, were finalized after design parameter optimization and fabricated using a cost-effective and simple etching method. A test setup consisting of a glass pressure chamber and a vacuum pump was developed to test and characterize the response of the sensors. Both sensors were tested for a narrow range (0-100 mmHg) and a wide range (0-300 mmHg) to cover most of the physiological pressure measurement applications. Both sensors showed good linearity with high sensitivity in the lower pressure range <100 mmHg, providing a wireless monitoring platform for compression therapy in venous ulceration.


Assuntos
Monitorização Fisiológica/instrumentação , Pressão , Dispositivos Eletrônicos Vestíveis , Tecnologia sem Fio , Humanos , Úlcera Varicosa/terapia
2.
Small ; 14(28): e1800863, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29862640

RESUMO

Following implantation, neuroelectrode functionality is susceptible to deterioration via reactive host cell response and glial scar-induced encapsulation. Within the neuroengineering community, there is a consensus that the induction of selective adhesion and regulated cellular interaction at the tissue-electrode interface can significantly enhance device interfacing and functionality in vivo. In particular, topographical modification holds promise for the development of functionalized neural interfaces to mediate initial cell adhesion and the subsequent evolution of gliosis, minimizing the onset of a proinflammatory glial phenotype, to provide long-term stability. Herein, a low-temperature microimprint-lithography technique for the development of micro-topographically functionalized neuroelectrode interfaces in electrodeposited poly(3,4-ethylenedioxythiophene):p-toluene sulfonate (PEDOT:PTS) is described and assessed in vitro. Platinum (Pt) microelectrodes are subjected to electrodeposition of a PEDOT:PTS microcoating, which is subsequently topographically functionalized with an ordered array of micropits, inducing a significant reduction in electrode electrical impedance and an increase in charge storage capacity. Furthermore, topographically functionalized electrodes reduce the adhesion of reactive astrocytes in vitro, evident from morphological changes in cell area, focal adhesion formation, and the synthesis of proinflammatory cytokines and chemokine factors. This study contributes to the understanding of gliosis in complex primary mixed cell cultures, and describes the role of micro-topographically modified neural interfaces in the development of stable microelectrode interfaces.


Assuntos
Benzenossulfonatos/química , Compostos Bicíclicos Heterocíclicos com Pontes/química , Impressão Molecular/métodos , Neuroglia/metabolismo , Polímeros/química , Animais , Astrócitos/citologia , Quimiocinas/metabolismo , Técnicas Eletroquímicas , Microeletrodos , Ratos Sprague-Dawley , Ratos Wistar
3.
Nanomaterials (Basel) ; 11(5)2021 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-33946273

RESUMO

We propose a novel low temperature annealing method for selective crystallization of gold thin films. Our method is based on a non-melt process using highly overlapped ultrashort laser pulses at a fluence below the damage threshold. Three different wavelengths of a femtosecond laser with the fundamental (1030 nm), second (515 nm) and third (343 nm) harmonic are used to crystallize 18-nm and 39-nm thick room temperature deposited gold thin films on a quartz substrate. Comparison of laser wavelengths confirms that improvements in electrical conductivity up to 40% are achievable for 18-nm gold film when treated with the 515-nm laser, and the 343-nm laser was found to be more effective in crystallizing 39-nm gold films with 29% improvement in the crystallinity. A two-temperature model provides an insight into ultrashort laser interactions with gold thin films and predicts that applied fluence was insufficient to cause melting of gold films. The simulation results suggest that non-equilibrium energy transfer between electrons and lattice leads to a solid-state and melt-free crystallization process. The proposed low fluence femtosecond laser processing method offers a possible solution for a melt-free thin film crystallization for wide industrial applications.

4.
ACS Appl Mater Interfaces ; 13(31): 37797-37808, 2021 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-34319701

RESUMO

A new process to crystallize amorphous silicon without melting and the generation of excessive heating of nearby components is presented. We propose the addition of a molybdenum layer to improve the quality of the laser-induced crystallization over that achieved by direct irradiation of silicon alone. The advantages are that it allows the control of crystallite size by varying the applied fluence of a near-infrared femtosecond laser. It offers two fluence regimes for nanocrystallization and polycrystallization with small and large crystallite sizes, respectively. The high repetition rate of the compact femtosecond laser source enables high-quality crystallization over large areas. In this proposed method, a multilayer structure is irradiated with a single femtosecond laser pulse. The multilayer structure includes a substrate, a target amorphous Si layer coated with an additional molybdenum thin film. The Si layer is crystallized by irradiating the Mo layer at different fluence regimes. The transfer of energy from the irradiated Mo layer to the Si film causes the crystallization of amorphous Si at low temperatures (∼700 K). Numerical simulations were carried out to estimate the electron and lattice temperatures for different fluence regimes using a two-temperature model. The roles of direct phonon transport and inelastic electron scattering at the Mo-Si interface were considered in the transfer of energy from the Mo to the Si film. The simulations confirm the experimental evidence that amorphous Si was crystallized in an all-solid-state process at temperatures lower than the melting point of Si, which is consistent with the results from transmission electron microscopy (TEM) and Raman. The formation of crystallized Si with controlled crystallite size after laser treatment can lead to longer mean free paths for carriers and increased electrical conductivity.

5.
Artigo em Inglês | MEDLINE | ID: mdl-34574595

RESUMO

Heavy metals are the major concern of the modern age. Among the heavy metals, chromium (Cr(VI)) is regarded as a highly toxic heavy metal released largely from leather tanning operations. To remove such high concentrations of Cr(VI), an advanced method is required urgently. Thus, biosorption using biochar, which is an organic material produced from various sources such as walnut shell, can be applied successfully for Cr(VI) abatement. The major objectives of this experiment were the remediation of the Cr(VI) heavy metal using walnut shell biochar and checking of the effect of pH, biochar dosage, Cr level, and shaking time. Remediation of Cr(VI) using walnut shell biochar was proved to be effective and removed the maximum concentration of Cr(VI) up to 93% at pH 5.5, 2 h agitation time, and the biochar amount of 1.1 g L-1 from an aqueous solution. Equilibrium modeling demonstrated that the chemisorption process was involved in adsorption of Cr(VI). The surface of the biochar was porous and provided numerous sites for Cr(VI) attachment, which was also confirmed by the presence of Cr(VI) onto the biochar after adsorption. Hence, the use of walnut shell biochar was highly effective as a sorbent, which could conveniently be applied to small-scale as well as large-scale levels.


Assuntos
Juglans , Poluentes Químicos da Água , Adsorção , Carvão Vegetal , Cromo/análise , Concentração de Íons de Hidrogênio , Águas Residuárias , Poluentes Químicos da Água/análise
6.
ACS Biomater Sci Eng ; 6(3): 1449-1461, 2020 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33455378

RESUMO

The brain machine interface (BMI) describes a group of technologies capable of communicating with excitable nervous tissue within the central nervous system (CNS). BMIs have seen major advances in recent years, but these advances have been impeded because of a temporal deterioration in the signal to noise ratio of recording electrodes following insertion into the CNS. This deterioration has been attributed to an intrinsic host tissue response, namely, reactive gliosis, which involves a complex series of immune mediators, resulting in implant encapsulation via the synthesis of pro-inflammatory signaling molecules and the recruitment of glial cells. There is a clinical need to reduce tissue encapsulation in situ and improve long-term neuroelectrode functionality. Physical modification of the electrode surface at the nanoscale could satisfy these requirements by integrating electrochemical and topographical signals to modulate neural cell behavior. In this study, commercially available platinum iridium (Pt/Ir) microelectrode probes were nanotopographically functionalized using femto/picosecond laser processing to generate laser-induced periodic surface structures (LIPSS). Three different topographies and their physical properties were assessed by scanning electron microscopy and atomic force microscopy. The electrochemical properties of these interfaces were investigated using electrochemical impedance spectroscopy and cyclic voltammetry. The in vitro response of mixed cortical cultures (embryonic rat E14/E17) was subsequently assessed by confocal microscopy, ELISA, and multiplex protein array analysis. Overall LIPSS features improved the electrochemical properties of the electrodes, promoted cell alignment, and modulated the expression of multiple ion channels involved in key neuronal functions.


Assuntos
Astrócitos , Neuroglia , Animais , Irídio , Lasers , Microeletrodos , Ratos
7.
Rev Sci Instrum ; 89(7): 073501, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30068087

RESUMO

The diagnosis of the fuel retention and impurity deposition on the plasma facing components (PFCs) is very important for monitoring plasma-wall interactions and improving the performance of long-pulse operation for tokamak devices. In this study, a remote in situ laser-induced breakdown spectroscopic (RIS-LIBS) system has been developed to be an effective and routine method for the diagnosis of the composition of the PFCs on Experimental Advanced Superconducting Tokamak (EAST). The RIS-LIBS system can be operated between EAST discharges via a remote network control system. This allows a flexible diagnosis for the PFCs at a specific EAST discharge operation or under planned plasma scenarios according to the experimental requirement. Measurements on the fuel retention and impurity deposition of the PFCs have been performed for the test of the RIS-LIBS system, and the depth resolution and the lateral resolution of the RIS-LIBS system have been achieved to be ∼100 nm and ∼3.0 mm, respectively. For the test of detectable elements, the fuel (deuterium) and impurities have been detected and identified clearly. In addition, the measurement of fuel abundance on the first wall as a function of the days of EAST deuterium plasma discharges has been carried out for the first time. These results well manifest a significant prospect of the RIS-LIBS for the diagnosis of the PFCs in the upcoming fusion devices like China Fusion Engineering Test Reactor (CFETR) and ITER.

SELEÇÃO DE REFERÊNCIAS