BMC Ophthalmol ; 18(1): 338, 2018 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-30587178

RESUMO

BACKGROUND: To assess a possible signal drift, noise and influences of electromagnetic radiation on the measurement behaviour of the Triggerfish® contact lens sensor, which might be mistaken as IOP fluctuations. METHODS: Contact lens sensors (Triggerfish®, SENSIMED AG, Lausanne, Switzerland) were fixed in a water bath. To reduce any external electromagnetic impulses, all plugs were removed from the sockets, no lights were switched on and no electronic devices, except a temperature logger were left in the test room. For 24 h signal drift, noise and the influences of a cordless telephone (Ascom d43 DECT Handset, EU DECT 1880-1900 MHz, Ascom Wireless, Baar, Switzerland), a smartphone (Sony Xperia Go ST27i, Sony Corporation, Tokyo, Japan) and a computer (Hewlett-Packard ProBook 650 15,6″ - D9S33AV, Hewlett-Packard Inc., Palo Alto, USA) on the measuring profile were analysed. RESULTS: Twenty-four-hour measurements without provoked external electromagnetic impulses yielded a profile without any signal drift and 8.2 mV eq noise. During the activation of the cordless telephone a maximum measurement variation of 3.2 mV eq. (4.1-7.3), smartphone 1.8 mV eq. (4.7-6.5) and computer 1.4 mV eq. (6.3-7.7) were observed. CONCLUSIONS: During 24-h measurements there was no signal drift and a very low noise. Patients concerned about electronic devices possibly interfering with the measurements of the contact lens sensor, can be informed, that the use of their cordless telephone, smartphone or computer does not cause any problems. The amount of the signal noise might help to define actual IOP fluctuations. Temperature fluctuations might influence the measuring profile.


Assuntos
Lentes de Contato , Radiação Eletromagnética , Glaucoma/diagnóstico , Pressão Intraocular/fisiologia , Hipertensão Ocular/diagnóstico , Tonometria Ocular/instrumentação , Computadores , Humanos , Smartphone , Telefone
3.
Klin Monbl Augenheilkd ; 235(11): 1269-1277, 2018 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-28837978

RESUMO

As glaucoma specialists, we often ask ourselves why patients are referred so late for surgery. Usually the patient is referred in a far advanced stage of the disease after long-term conventional treatment with topical medications. By that time, substantial morphologic damage is present and the patient is disabled by far advanced visual field defects. In addition, decompensated intraocular pressure, despite maximal tolerated medical treatment, is seen. Delayed surgery due to late diagnosis is rather a rare event. Various reasons may be responsible for this late referral. Improved IOP-lowering medications (i.e., fixed combinations), personal aversion (fear and knowledge of lack of improvement in visual acuity) against surgery, and imperfect glaucoma procedures may play an important role. A retrospective review of the last 274 cases referred for filtering glaucoma surgery is used to describe and analyze criteria for adequate timing of glaucoma surgery. This study reveals that almost ¾ of patients are referred rather late for glaucoma surgery. Criteria for adequate timing of glaucoma surgery are given for non-glaucoma specialists in particular. They apply for all types of glaucoma surgery, and the pros and cons are discussed in detail. Trabeculectomy is still regarded as the gold standard of glaucoma surgery. Because trabeculectomy may not be an ideal glaucoma procedure, there is hope that the modern less-invasive glaucoma procedures (MIGS) will be able to extend indications for glaucoma surgery. This may also lower the hurdle of referral for glaucoma surgery for both patients and non-glaucoma specialist doctors.


Assuntos
Glaucoma , Trabeculectomia , Seguimentos , Glaucoma/cirurgia , Humanos , Pressão Intraocular , Estudos Retrospectivos , Fatores de Tempo , Trabeculectomia/métodos
7.
Mol Vis ; 19: 2306-11, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24265545

RESUMO

PURPOSE: Various cytokines, including tumor necrosis factor-alpha (TNF-α), Fas ligand (FasL), interleukin-1α (IL-1α), interleukin-1ß (IL-1ß), and interleukin-6 (IL-6), contribute to the pathogenesis of primary open angle glaucoma (POAG). The present study was set to measure these cytokines in the aqueous humor of patients with POAG and in control subjects using multiplex bead analysis. METHODS: Twenty-five patients with POAG and 29 control subjects were enrolled in this case-control study. Aqueous humor concentrations of the cytokines (IL-1 α, IL-1 ß, IL-6, FasL, and TNF- α) were measured using multiplex bead analysis. RESULTS: Mean aqueous humor levels of IL-6 were significantly lower in patients with POAG compared to the control subjects (9.3±23.7 versus 55.3±94.4 pg/ml; p=0.002). No significant difference in the aqueous humor concentration of IL-1ß was found between patients with POAG and control subjects (0.5±0.8 versus 0.4±0.8 pg/ml; p=0.85.) Concentrations of IL-1α, TNF-α, and FasL were below limits of detection. No significant correlation was found between IL-6 concentration and age, duration of disease, cup/disc ratio, or mean deviation. CONCLUSIONS: In the present study, we found significantly lower concentrations of IL-6 in the aqueous humor of patients with POAG.


Assuntos
Humor Aquoso/metabolismo , Proteína Ligante Fas/metabolismo , Glaucoma de Ângulo Aberto/metabolismo , Imunoensaio/métodos , Interleucina-1alfa/metabolismo , Interleucina-1beta/metabolismo , Interleucina-6/metabolismo , Fator de Necrose Tumoral alfa/metabolismo , Idoso , Catarata/metabolismo , Feminino , Humanos , Masculino
8.
Ophthalmology ; 120(12): 2470-2475, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23809273

RESUMO

PURPOSE: To determine the ability of ophthalmologists across Europe to match stereoscopic optic disc photographs to visual fields of varying severity. DESIGN: Evaluation and comparison of 2 diagnostic tests. PARTICIPANTS: A total of 109 of 260 invited ophthalmologists in 11 European countries. These had participated in the previous European Optic Disc Assessment Trial (EODAT), a trial on glaucoma diagnostic accuracy based on optic discs only. METHODS: Each participant matched stereo optic disc photographs of 40 healthy and 48 glaucomatous eyes to a visual field chosen from 4 options per disc. The 4 presented visual fields included the corresponding one and 3 other visual fields, varying in severity. The matching accuracy and any inaccuracy per disease severity were calculated. Classification accuracy (as glaucomatous or healthy) was compared with EODAT data. Duplicate slides allowed for the assessment of intraobserver agreement. MAIN OUTCOME MEASURES: Accuracy of matching optic discs with their corresponding visual field and of classifying them as healthy or glaucomatous; intraobserver agreement (κ). RESULTS: The overall accuracy of ophthalmologists for correctly matching stereoscopic optic disc photographs to their visual fields was 58.7%. When incorrectly matched, the observers generally overestimated the visual field severity (P<0.001), notably in eyes with early glaucoma. The intraobserver agreement was, on average, moderate (0.52). CONCLUSIONS: European ophthalmologists correctly matched stereoscopic optic disc photographs to their corresponding visual field in only approximately 59% of cases. In most mismatches, the clinicians overestimated the visual field damage.


Assuntos
Glaucoma/diagnóstico , Oftalmologia/estatística & dados numéricos , Disco Óptico/patologia , Doenças do Nervo Óptico/diagnóstico , Transtornos da Visão/fisiopatologia , Campos Visuais/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Hipertensão Ocular/diagnóstico , Oftalmologia/normas , Oftalmoscopia , Fotografação , Reprodutibilidade dos Testes , Testes de Campo Visual , População Branca
10.
Mol Vis ; 17: 616-20, 2011 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-21386929

RESUMO

PURPOSE: The enzyme cholesterol 24S-hydroxylase (Cyp46A1) is responsible for the conversion of cholesterol to its more polar metabolite 24S-hydroxycholesterol, thereby enabling the intracerebral elimination of cholesterol. An intronic single nucleotide polymorphism in the gene CYP46A1 (IVS2 -150 T>C; rs754203) has recently been associated with primary open angle glaucoma (POAG). This association, however, lacks confirmation in other studies. The purpose of the present study was to investigate a hypothesized association between rs754203 and the presence of POAG in a Central European population of Caucasian descent. METHODS: The present institutional study comprised a total of 581 unrelated subjects: 330 patients with POAG, and 251 control subjects. Main outcome measures are genotype distributions and allelic frequencies determined by polymerase chain reaction. RESULTS: No significant differences in either genotype distribution or allelic frequencies were found between patients with POAG and control subjects (p>0.05). The presence of the rs754203 T-allele was associated with a nonsignificant odds ratio of 0.81 (95% CI: 0.63-1.04; p=0.11) for POAG. CONCLUSIONS: Our data suggest that the rs754203 polymorphism itself is unlikely a genetic risk factor for POAG in Caucasian individuals.


Assuntos
Predisposição Genética para Doença , Glaucoma de Ângulo Aberto/enzimologia , Glaucoma de Ângulo Aberto/genética , Polimorfismo de Nucleotídeo Único/genética , Esteroide Hidroxilases/genética , Idoso , Colesterol 24-Hidroxilase , Feminino , Frequência do Gene/genética , Humanos , Masculino
11.
J Glaucoma ; 30(12): 1039-1046, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34559700

RESUMO

PRCIS: Automated gonioscopy is a recent method of recording angle pictures. Our study shows that agreement between observers is moderate in most categories used in clinical practice, underlying its clinical usefulness but also room for improvement. INTRODUCTION: Iridocorneal angle (ICA) imaging methods have been recently developed to record gonioscopic images. The purpose of this study was to perform an interrater agreement analysis of ICA photographs. METHODS: Multicentric cross-sectional observational study. Consecutive patients in 2 ophthalmology departments underwent automated gonioscopy. One picture per quadrant from each eye was selected for randomization. Pictures were graded and analyzed by 4 masked glaucoma specialists regarding angle opening, width, Shaffer and Spaeth gradings and other findings. Fleiss' κ statistics was performed to assess interrater agreement. RESULTS: A total of 50 patients were recruited, with the sample containing a variety of diagnosis including pseudoexfoliation (22%), angle-closure suspect (12%), and pigmentary glaucoma (4%). The sample included phakic (68%) and pseudophakic patients, as well as cases with gonio-implanted surgical devices (10%). There was moderate agreement on angle opening, angle width, presence of angle vessels, and peripheral anterior synechiae (κ=0.435, 0.511, 0.558, 0.488, respectively; P<0.01). Fair agreement was observed regarding Shaffer grading, site of iris root insertion, angle pigmentation features, and the presence of iris processes. Expectedly from a 2-dimensional picture, the configuration of peripheral iris was found to have a poor agreement. Subset analysis on higher quality pictures seemed to improve agreement on pigment but did not further improve on the overall good agreement on angle opening status. CONCLUSIONS: Our study shows that automated gonioscopy provides moderate agreement on most clinically relevant features. Binary characteristics such as angle opening or PAS seem to be more robust than more complex angle classification parameters.


Assuntos
Glaucoma de Ângulo Fechado , Estudos Transversais , Glaucoma de Ângulo Fechado/diagnóstico , Gonioscopia , Humanos , Pressão Intraocular , Iris/diagnóstico por imagem
12.
Mol Vis ; 16: 1764-70, 2010 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-20808730

RESUMO

PURPOSE: Matrix metalloproteinases (MMPs) play an essential role in the turnover of the extracellular matrix and cellular behavior. MMP1, MMP2, and MMP9 have previously been implicated in the pathogenesis of primary open angle glaucoma (POAG) and open angle glaucoma secondary to exfoliation syndrome (XFG), respectively. Functional gene polymorphisms of these MMPs such as MMP1 -1607 1G/2G (rs1799750), MMP2 -1306 C/T (rs243865), MMP2 -1575 G/A (rs243866), and MMP9 Q279R (rs17576) are thus plausible candidates as risk factors for open angle glaucomas. The purpose of the present study was to investigate hypothesized associations between these polymorphisms and the presence of POAG and XFG in a Caucasian population. METHODS: The present case-control study included 322 patients with POAG, 202 patients with XFG, and 248 control subjects. Genotyping of polymorphisms was done using polymerase chain reaction. RESULTS: No significant differences in either genotype distributions or allelic frequencies of MMP1 -1607 1G/2G, MMP2 -1306 C/T, MMP2 -1575 G/A, and MMP9 Q279R were found between patients with POAG and control subjects and patients with XFG and control subjects, respectively (p>0.05). The presence of POAG or XFG was not predicted by any of the investigated polymorphisms. CONCLUSIONS: Our data suggest that the MMP1 -1607 1G/2G, MMP2 -1306 C/T, MMP2 -1575 G/A, and MMP9 Q279R polymorphisms themselves are unlikely major risk factors among Caucasian patients with either POAG or XFG.


Assuntos
Glaucoma de Ângulo Aberto/enzimologia , Glaucoma de Ângulo Aberto/genética , Metaloproteinases da Matriz/genética , Polimorfismo de Nucleotídeo Único/genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Síndrome de Exfoliação/enzimologia , Síndrome de Exfoliação/genética , Feminino , Frequência do Gene/genética , Genótipo , Humanos , Modelos Logísticos , Masculino , Metaloproteinase 1 da Matriz/genética , Metaloproteinase 2 da Matriz/genética , Metaloproteinase 9 da Matriz/genética , Pessoa de Meia-Idade
13.
Ophthalmology ; 117(4): 717-23, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20045571

RESUMO

PURPOSE: To determine the diagnostic accuracy of judging optic disc photographs for glaucoma by ophthalmologists. DESIGN: Evaluation of diagnostic test and technology. PARTICIPANTS: A total of 243 of 875 invited ophthalmologists in 11 European countries. METHODS: We determined how well each participant classified 40 healthy eyes and 48 glaucomatous eyes with varying severity of the disease on stereoscopic slides. Duplicate slides were provided for determining intraobserver agreement. All eyes were also imaged with the GDx with variable corneal compensation (GDx-VCC) (Carl Zeiss Meditec AG, Jena, Germany) and the Heidelberg Retina Tomograph (HRT) I (Heidelberg Engineering GmbH, Heidelberg, Germany). Diagnostic accuracies of clinicians were compared with those of the best machine classifiers. MAIN OUTCOME MEASURES: Accuracy of classification, expressed as sensitivity, specificity, and overall accuracy. Intraobserver agreement (kappa). RESULTS: The overall diagnostic accuracy of ophthalmologists was 80.5% (standard deviation [SD], 6.8; range, 61.4%-94.3%). The machine classifiers outperformed most observers in diagnostic accuracy; the GDx-VCC nerve fiber indicator and the HRT's best classifier correctly classified 93.2% and 89.8% of eyes, respectively. The intraobserver agreement (kappa) varied between -0.13 and 1.0 and was on average good (0.7). CONCLUSIONS: In general, ophthalmologists classify optic disc photographs moderately well for detecting glaucoma. There is, however, large variability in diagnostic accuracy among and agreement within clinicians. Common imaging devices outperform most clinicians in classifying optic discs. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.


Assuntos
Glaucoma/diagnóstico , Disco Óptico/patologia , Fotografação/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Europa (Continente) , Feminino , Pessoal de Saúde , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Hipertensão Ocular/diagnóstico , Oftalmologia , Oftalmoscopia , Reprodutibilidade dos Testes , Polarimetria de Varredura a Laser , Sensibilidade e Especificidade , Tomografia/métodos
14.
Ophthalmologica ; 224(4): 217-23, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19940528

RESUMO

BACKGROUND: To analyse the influence of hyaluronate (HA) on the cell vitality of human conjunctival cells after chemical injuries from NaOH or alkali-containing household cleaners. METHODS: Human conjunctival cells (Chang cells) were incubated either with NaOH solutions or dilutions of household cleaners. HA (0.025%) was added to the cell culture medium of part of the cells subsequent to chemical injuring. After 24 h the cell vitality of the HA-incubated cells, determined by MTS assay (Cell Titer 96(R) Aqueous One Solution Cell Proliferation Assay), was compared to the control cells without HA addition. RESULTS: The addition of HA to the cell culture medium subsequent to chemical injuring resulted in a significantly lower decrease in cell vitality (mean difference: 11.79; p = 0.00; CI = 98%). CONCLUSION: Because HA attenuates the decrease in cell vitality of alkali-damaged human conjunctival cells, formulations containing HA may be recommended for the treatment of chemical injuries to the anterior part of the eye.


Assuntos
Adjuvantes Imunológicos/farmacologia , Álcalis/toxicidade , Túnica Conjuntiva/citologia , Túnica Conjuntiva/efeitos dos fármacos , Ácido Hialurônico/farmacologia , Contagem de Células/métodos , Células Cultivadas , Relação Dose-Resposta a Droga , Interações Medicamentosas , Humanos , Estatísticas não Paramétricas
15.
Mol Vis ; 15: 518-22, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19279689

RESUMO

PURPOSE: TNF-alpha has been suggested to participate in the pathogenesis of exfoliation glaucoma (XFG). The purpose of the present study was to investigate a hypothesized association between two common functional polymorphisms in the promoter region of the TNF-alpha gene (TNF-alpha -308 G>A, rs1800629, and TNF-alpha -238 G>A, rs361525) and the presence of XFG in a Caucasian population. METHODS: The present case-control study comprised 408 participants (204 patients with XFG and 204 control subjects). Control subjects were matched for age and sex. Genotypes of the TNF-alpha -308 G>A and TNF-alpha -238 G>A polymorphisms were determined by polymerase chain reaction (restriction fragment length polymorphism). RESULTS: No significant differences regarding genotype distribution or allelic frequencies were found between patients and control subjects (p>0.025). The presence of the TNF-alpha -308 G-allele was associated with an insignificant odds ratio of 0.98 (95% confidence interval [CI]: 0.66-1.46; p=0.99) while the presence of the TNF-alpha -238 G-allele was associated with an insignificant odds ratio of 0.64 (95% CI: 0.33-1.23; p=0.25). CONCLUSIONS: Our data suggest that both the TNF-alpha -308 G>A and the TNF-alpha -238 G>A polymorphisms are unlikely to be major risk factors for XFG in an European population of Caucasian descent.


Assuntos
Síndrome de Exfoliação , Glaucoma , Polimorfismo de Nucleotídeo Único , Fator de Necrose Tumoral alfa/genética , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Síndrome de Exfoliação/complicações , Síndrome de Exfoliação/genética , Feminino , Frequência do Gene , Predisposição Genética para Doença , Genótipo , Glaucoma/etiologia , Glaucoma/genética , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Fatores de Risco , População Branca/genética
16.
Mol Vis ; 14: 1240-4, 2008 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-18615155

RESUMO

PURPOSE: Alterations of the plasmin system have been suggested to participate in the multifactorial pathogenesis of primary open-angle glaucoma (POAG). The main physiological inhibitor of the plasmin system is plasminogen activator inhibitor-1 (PAI-1), which leads to decreased degradation of extracellular material. Interestingly, elevated PAI-1 levels in the aqueous humor of patients with POAG have been reported. A common polymorphism within the promoter region (PAI-1 4G/5G) has previously been shown to reduce the gene transcription rate of PAI-1. The purpose of the present study was to investigate a hypothesized association between PAI-1 4G/5G and the presence of POAG in a Caucasian population. METHODS: The present case-control study comprised 212 unrelated patients with POAG and 212 healthy control subjects, matched for age and sex. Genotyping of PAI-1 4G/5G polymorphisms was done using polymerase chain reaction. RESULTS: Allelic frequencies and genotype distributions of PAI-1 4G/5G did not significantly differ between patients with POAG and control subjects (PAI-1 4G/5G: 29.7% versus 29.7%). Presence of the PAI-1 4G-allele was associated with a nonsignificant odds ratio of 0.98 (95% confidence interval: 0.74-1.30) for POAG. CONCLUSIONS: Our data suggest that PAI-1 4G/5G itself is unlikely to be a major risk factor among Caucasian patients with POAG.


Assuntos
Glaucoma de Ângulo Aberto/genética , Inibidor 1 de Ativador de Plasminogênio/genética , Polimorfismo de Nucleotídeo Único/genética , Idoso , Estudos de Casos e Controles , Feminino , Frequência do Gene , Genótipo , Humanos , Masculino
17.
Mol Vis ; 14: 857-61, 2008 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-18483563

RESUMO

PURPOSE: Exfoliation syndrome (XFS) is characterized by an accumulation of abnormal extracellular material in the anterior part of the eye that frequently leads to increased intraocular pressure and glaucomatous optic neuropathy. Recently, two non-synonymous polymorphisms (rs1048661 G>T and rs3825942 G>A) of lysyl oxidase-like protein 1 (LOXL1), a monoamine oxidase that catalyzes the polymerization of tropoelastin to elastin, were found to be associated with increased risk for XFS and exfoliation glaucoma (XFG). The aim of the present study was to investigate the role of these LOXL1 variants in a Central European cohort of Caucasian patients with XFG. METHODS: The present case-control study comprised of 167 unrelated patients with XFG and 170 control subjects. Genotyping of the LOXL1 rs1048661 and rs3825942 polymorphisms was done using polymerase chain reaction. RESULTS: The frequency of allele G of rs1048661 as well as rs3825942 was significantly higher in patients than in controls (rs1048661: 0.841 in patients versus 0.669; p<0.001; rs3825942: 0.994 in patients versus 0.817; p<0.001). Odds ratios of 52.1 (95% confidence interval [CI]: 13.85-195.6) and 14.67 (95% CI: 3.81-56.2), respectively, were calculated for the two high-risk haplotypes GG and TG compared to the haplotype GA. CONCLUSIONS: Our data confirm the previously reported association between LOXL1 polymorphisms and XFG and extend our knowledge to a Central European population.


Assuntos
Aminoácido Oxirredutases/genética , Síndrome de Exfoliação/enzimologia , Síndrome de Exfoliação/genética , Glaucoma/enzimologia , Glaucoma/genética , Polimorfismo de Nucleotídeo Único/genética , População Branca/genética , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Frequência do Gene , Haplótipos , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances
18.
Mol Vis ; 12: 356-9, 2006 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-16636653

RESUMO

PURPOSE: Increased plasma homocysteine levels have been found in patients with primary open angle glaucoma (POAG) and glaucoma secondary to pseudoexfoliation syndrome (PEXG). A common polymorphism of the methylenetetrahydrofolatereductase (MTHFR 677C>T) leads to moderately elevated plasma homocysteine levels particularly under conditions of impaired folate status. It was the aim of this study to investigate a hypothesized association between this polymorphism and the presence of either POAG or PEXG. METHODS: The present retrospective case-control study included a total of 553 participants comprising 204 patients with POAG, 138 patients with PEXG, and 211 control subjects. Genotyping for the MTHFR 677C>T polymorphism was performed by polymerase chain reaction (PCR). RESULTS: No significant difference in the genotype distribution of the MTHFR 677C>T polymorphism was found between control subjects and patients with POAG or PEXG. The prevalence of the MTHFR 677TT genotype was 6.9% in patients with POAG, 11.6% in patients with PEXG, and 9.5% in control subjects. CONCLUSIONS: The present data suggest that the MTHFR 677C>T polymorphism itself is not a major genetic risk factor for POAG and PEXG in a central European population.


Assuntos
Síndrome de Exfoliação/genética , Glaucoma de Ângulo Aberto/genética , Metilenotetra-Hidrofolato Redutase (NADPH2)/genética , Polimorfismo Genético , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Citosina , Feminino , Frequência do Gene , Predisposição Genética para Doença , Genótipo , Humanos , Masculino , Razão de Chances , Timina
19.
Cornea ; 25(4): 423-7, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16670479

RESUMO

PURPOSE: This study was undertaken in order to determine the susceptibility of acanthamoebae to various contact lens disinfecting systems, with respect to type of disinfectant and exposure time. METHODS: Ten contact lens solutions, including one new system, were tested for their effectivities against cysts of three Acanthamoeba strains. Of main interest was an incubation time of 8 hours (overnight disinfection) and cyst quantities of 10 and 10, respectively. RESULTS: Boston Advance (polyaminopropyl biguanide 0.0005%, chlorhexidine 0.003%) for the storage of rigid gas permeable contact lenses destroyed the cysts of all strains at either concentration within one hour of exposure. Meni Care Plus (polyhexamethylene biguanide 0.0005%) also destroyed 10 cysts of all strains, however, 10 cysts only of two strains within one hour; after an exposure time of 8 hours all cysts were killed. The disinfecting solutions for soft contact lenses did not kill 10 cysts of either strain after 8 hours of incubation time. CONCLUSION: Two of the tested contact lens solutions (the ones for rigid gas permeable lenses) destroyed the cysts of all strains. One of these, containing a combination of two amoebicidal ingredients even after only one hour of exposure time.


Assuntos
Acanthamoeba/efeitos dos fármacos , Soluções para Lentes de Contato/farmacologia , Desinfetantes/farmacologia , Desinfecção/métodos , Acanthamoeba/classificação , Acanthamoeba/crescimento & desenvolvimento , Animais , Biguanidas/farmacologia , Clorexidina/análogos & derivados , Clorexidina/farmacologia , Lentes de Contato Hidrofílicas , Quimioterapia Combinada , Contaminação de Equipamentos , Fatores de Tempo
20.
J Cataract Refract Surg ; 29(1): 217-9, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12551693

RESUMO

Three years after uneventful excimer laser photorefractive keratectomy in both eyes, a 34-year-old man sustained a perforating injury in the left eye. The severe injury, followed by endophthalmitis and retinal detachment, necessitated vitrectomy, lensectomy, and an internal tamponade with silicone oil. One month after the accident and operations, disk-shaped corneal edema corresponding to the laser treatment zone appeared. The edematous region showed a circular, ring-like epithelial thickening at the borders and central corneal epithelial erosion. The anterior stroma developed a central opacity that was separated by a clear rim from the developing silicone-oil keratopathy with the typical band shape.


Assuntos
Doenças da Córnea/etiologia , Oftalmopatias/cirurgia , Traumatismos Oculares/complicações , Ceratectomia Fotorrefrativa/efeitos adversos , Óleos de Silicone/efeitos adversos , Vitrectomia , Ferimentos Perfurantes/complicações , Adulto , Córnea/patologia , Endoftalmite/etiologia , Endoftalmite/cirurgia , Oftalmopatias/etiologia , Traumatismos Oculares/cirurgia , Humanos , Lasers de Excimer , Cristalino/cirurgia , Masculino , Descolamento Retiniano/etiologia , Descolamento Retiniano/cirurgia , Ferimentos Perfurantes/cirurgia