Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Surg Laparosc Endosc Percutan Tech ; 15(4): 220-5, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16082310

RESUMO

Vascular surgery is evolving, as other specialities, toward minimally invasive techniques. Presently, 3 approaches to aortoiliac disease are suggested as minimally invasive. Besides the endovascular procedures, laparoscopic techniques and minilaparotomy are being advocated. Although for aneurysmal disease, we favor a totally laparoscopic approach, criticisms raised over laparoscopy-assisted techniques by those advocating minilaparotomy led us to investigate the benefits of the latter technique. We first evaluated the procedure in 7 patients with infrarenal abdominal aortic aneurysm (AAA). We found the procedure impossible to perform with an 8- to 10-cm incision in 6 of the 7 patients. This led us to evaluate causes of failure of the technique. It appeared to us that most of our complications were related to inadequate exposure. Fifty consecutive computed tomography scans from patients with AAA of surgical size were then reviewed to evaluate the aneurysm lengths and compare them to the reported lengths of skin incision for minilaparotomy. Results were expressed adding a total of 2 cm for proximal and distal clamping. Only 2% of patients would present with aneurysms suitable for treatment through an 8-cm midline incision and 30% through a 10-cm incision. We then reviewed the literature on minilaparotomy. We believe that minilaparotomy should be reserved for those patients with purely aortic disease and the appropriate body habitus.


Assuntos
Aneurisma Aórtico/cirurgia , Aneurisma Ilíaco/cirurgia , Laparotomia/métodos , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Radiografia
2.
J Endovasc Ther ; 13(3): 350-6, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16784323

RESUMO

PURPOSE: To present a laparoscopic technique for placing a transperitoneal conduit in the common iliac artery (CIA) or distal aorta to circumvent stenosed or occluded iliac systems and to assess the success of this laparoscopic access in a live animal model. TECHNIQUE: A porcine model was used owing to similarities in anatomy and size of the pig aorta to the human common iliac artery (CIA). Ethical approval was obtained, and the technique was developed in 8 animals under general anesthesia. A curved hollow needle, a partially stented Dacron conduit, an airtight laparoscopic port and a sealing sheath and valve were developed specifically for percutaneous access through the abdominal wall. A transperitoneal approach was used to the distal aorta. Cannulation by the curved hollow needle via the new port was under direct vision. The conduit was inserted over a guidewire after needle removal and deployed under fluoroscopy. The distal end of the conduit was secured by the sealing sheath and valve, enabling wire and catheter exchange thereafter. A 2-day educational workshop was held for 12 vascular surgeons with a range of laparoscopic experience. After learning the technique on a simulator model, they worked in pairs, alternating surgeon/assistant roles to insert conduits into 12 animals under general anesthesia. Laparoscopic cannulation in all 12 animals was successful. There was no bleeding around the conduit at the aortic arteriotomy. All animals were euthanized after confirmation of conduit patency by back-bleeding. CONCLUSION: This novel technique bridges the gap between laparoscopic and endovascular techniques in striving for minimally invasive solutions to the treatment of vascular disease. Adaptation to human beings is currently underway and will mean increasing the applicability of endovascular solutions to those patients in whom it would otherwise be denied. The technique would appear not to require specialist laparoscopic skills.


Assuntos
Angioplastia/educação , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/educação , Educação Médica Continuada , Laparoscopia , Modelos Animais , Animais , Aorta/cirurgia , Instrução por Computador , Humanos , Artéria Ilíaca/cirurgia , Suínos
3.
J Vasc Surg ; 38(2): 403-6, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12891131

RESUMO

Since our original description in 1997 of a totally laparoscopic technique for treatment of aortoiliac disease, this type of minimally invasive procedure has been used both in the United States and abroad. We describe improvements that should make this technique more easily reproducible. This modified procedure was offered to six patients, one of whom received a tube graft for treatment of aneurysm disease.


Assuntos
Aorta/cirurgia , Arteriopatias Oclusivas/cirurgia , Implante de Prótese Vascular/métodos , Artéria Ilíaca/cirurgia , Laparoscopia/métodos , Humanos
4.
J Endovasc Ther ; 10(5): 946-52, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14656175

RESUMO

PURPOSE: To report initial experiments involving a new method for percutaneous intraprocedural stent-graft fenestration from the target vessel. TECHNIQUE: In bench and canine models, the fabric of an implanted Zenith endograft was punctured easily using the stiff end of a coronary 0.014-inch guidewire delivered through the target vessel (e.g., renal or iliac artery). A 20-G cutting needle was passed over the coronary wire to enlarge the puncture site, followed by a cutting balloon to create a fenestration that was of sufficient size to allow deployment of a stent. CONCLUSIONS: In vivo endograft fenestration of a Zenith endograft is feasible. In addition to providing a percutaneous means of intentionally fenestrating a stent-graft from the artery to be perfused, the technique has potential application as a bailout maneuver after inadvertent side branch occlusion. Although the time to achieve successful fenestration in the experimental model was long, refinement may achieve performance times adequate to maintain viability of the end organ.


Assuntos
Prótese Vascular , Stents , Procedimentos Cirúrgicos Vasculares/métodos , Animais , Cães , Estudos de Viabilidade , Artéria Ilíaca , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA