Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 488(7413): 603-8, 2012 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-22932384

RESUMO

Light-matter interactions are ubiquitous, and underpin a wide range of basic research fields and applied technologies. Although optical interactions have been intensively studied, their microscopic details are often poorly understood and have so far not been directly measurable. X-ray and optical wave mixing was proposed nearly half a century ago as an atomic-scale probe of optical interactions but has not yet been observed owing to a lack of sufficiently intense X-ray sources. Here we use an X-ray laser to demonstrate X-ray and optical sum-frequency generation. The underlying nonlinearity is a reciprocal-space probe of the optically induced charges and associated microscopic fields that arise in an illuminated material. To within the experimental errors, the measured efficiency is consistent with first-principles calculations of microscopic optical polarization in diamond. The ability to probe optical interactions on the atomic scale offers new opportunities in both basic and applied areas of science.

2.
Phys Rev Lett ; 109(1): 013602, 2012 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-23031104

RESUMO

We experimentally and theoretically study the coincidence count rate for down-converted x-ray photons. Because of photoionization, parametric down-conversion at x-ray wavelengths generally involves loss and the theoretical description requires a Langevin approach. By working in a transmission geometry (Laue) rather than in the Bragg geometry of previous experiments, we obtain an improvement in the signal-to-noise ratio of 12.5, and find agreement between experiment and theory.

3.
Rev Sci Instrum ; 78(7): 073702, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17672761

RESUMO

We have designed and built a compact x-ray microtomography system to perform element mapping and absorption imaging by exploiting scanning fluorescence tomography and full-field transmission microtomography, respectively. It is based on a low power microfocus tube and is potentially appropriate for x-ray diagnostics in space. Full-field transmission tomography yields the three-dimensional inner structure of an object. Fluorescence microtomography provides the element distribution on a virtual section through the sample. Both techniques can be combined for appropriate samples. Microradiography as well as fluorescence mapping are also possible. For fluorescence microtomography a small and intensive microbeam is required. It is generated using a polycapillary optic. Operating the microfocus tube with a molybdenum target at 12 W, a microbeam with a full width at half maximum lateral extension of 16 microm and a flux of about 10(8) photonss is generated. As an example of application, this beam is used to determine the element distribution inside dried plant samples. For full-field scanning tomography, the x-ray optic is removed and the sample is imaged in magnifying projection onto a two-dimensional position sensitive detector. Depending on the sample size, a spatial resolution down to about 10 microm is possible in this mode. The method is demonstrated by three-dimensional imaging of a rat humerus.


Assuntos
Absorciometria de Fóton/instrumentação , Tomografia por Raios X/instrumentação , Absorciometria de Fóton/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
J Phys Condens Matter ; 23(18): 184111, 2011 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-21508480

RESUMO

The structure and flow of droplets on solid surfaces is investigated with imaging and scattering techniques and compared to simulations. To access nanostructures at the liquid-solid interface advanced scattering techniques such as grazing incidence small-angle x-ray scattering (GISAXS) with micro- and nanometer-sized beams, GISAXS and in situ imaging ellipsometry and GISAXS tomography are used. Using gold nanoparticle suspensions, structures observed in the wetting area due to deposition are probed in situ during the drying of the droplets. After drying, nanostructures in the wetting area and inside the dried droplets are monitored. In addition to drying, a macroscopic movement of droplets is caused by body forces acting on an inclined substrate. The complexity of the solid surfaces is increased from simple silicon substrates to binary polymer brushes, which undergo a switching due to the liquid in the droplet. Nanostructures introduced in the polymer brush due to the movement of droplets are observed.


Assuntos
Ouro/química , Nanoestruturas/química , Física/métodos , Simulação por Computador , Eletrônica , Nanopartículas/química , Nanotecnologia/métodos , Tamanho da Partícula , Polímeros/química , Espalhamento de Radiação , Silício , Propriedades de Superfície , Molhabilidade , Raios X
5.
Phys Rev Lett ; 101(9): 090801, 2008 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-18851597

RESUMO

Coherent x-ray diffraction imaging is an x-ray microscopy technique with the potential of reaching spatial resolutions well beyond the diffraction limits of x-ray microscopes based on optics. However, the available coherent dose at modern x-ray sources is limited, setting practical bounds on the spatial resolution of the technique. By focusing the available coherent flux onto the sample, the spatial resolution can be improved for radiation-hard specimens. A small gold particle (size <100 nm) was illuminated with a hard x-ray nanobeam (E=15.25 keV, beam dimensions approximately 100 x 100 nm2) and is reconstructed from its coherent diffraction pattern. A resolution of about 5 nm is achieved in 600 s exposure time.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA