Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 186
Filtrar
1.
Appl Microbiol Biotechnol ; 108(1): 152, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38183477

RESUMO

Trichothecenes are a structurally diverse family of toxic secondary metabolites produced by certain species of multiple fungal genera. All trichothecene analogs share a core 12,13-epoxytrichothec-9-ene (EPT) structure but differ in presence, absence and types of substituents attached to various positions of EPT. Formation of some of the structural diversity begins early in the biosynthetic pathway such that some producing species have few trichothecene biosynthetic intermediates in common. Cytochrome P450 monooxygenases (P450s) play critical roles in formation of trichothecene structural diversity. Within some species, relaxed substrate specificities of P450s allow individual orthologs of the enzymes to modify multiple trichothecene biosynthetic intermediates. It is not clear, however, whether the relaxed specificity extends to biosynthetic intermediates that are not produced by the species in which the orthologs originate. To address this knowledge gap, we used a mutant complementation-heterologous expression analysis to assess whether orthologs of three trichothecene biosynthetic P450s (TRI11, TRI13 and TRI22) from Fusarium sporotrichioides, Trichoderma arundinaceum, and Paramyrothecium roridum can modify trichothecene biosynthetic intermediates that they do not encounter in the organism in which they originated. The results indicate that TRI13 and TRI22 could not modify the intermediates that they do not normally encounter, whereas TRI11 could modify an intermediate that it does not normally encounter. These findings indicate that substrate promiscuity varies among trichothecene biosynthetic P450s. One structural feature that likely impacts the ability of the P450s to use biosynthetic intermediates as substrates is the presence and absence of an oxygen atom attached to carbon atom 3 of EPT.


Assuntos
Sistema Enzimático do Citocromo P-450 , Tricotecenos , Especificidade por Substrato , Sistema Enzimático do Citocromo P-450/genética , Metabolismo Secundário
2.
Molecules ; 29(12)2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38930844

RESUMO

Organic phosphoester (OPE) antioxidants are currently required due to their contribution to enhancing the quality of polymers, including polypropylene (PP). In this research, an integral methodology is presented for the efficient extraction of bis(2,4-dicumylphenyl) pentaerythritol diphosphite from industrial wastewater. Upon employing the solid-phase extraction (SPE) technique, the recovered compound is subjected to a comprehensive analysis of the recovered compound using high-performance liquid chromatography (HPLC), mass spectrometry (MS), thermal analysis (TGA), Fourier transforms infrared spectroscopy (FTIR), and differential scanning calorimetry (DSC). Subsequently, purified Bis(2,4-dicumylphenyl) pentaerythritol diphosphite was evaluated as a thermo-oxidative stabilizer after incorporation into PP resins. The relative standard deviation (RSD), Error (Er), linearity (R2), and percentage (%) recovery were less than 2.6, 2.5, more significant than 0.9995, and greater than 96%, respectively, for the inter-day and intra-day tests of the chromatographic method and the SPE. Except for chloroform, which was necessary due to the solubility properties of the investigated analyte, the use of environmentally friendly solvents, such as methanol and acetonitrile, was considered during the development of this research. The OPE extracted from industrial wastewater was characterized by FTIR, UV-Vis, DSC, TGA, and MS, allowing the elucidation of the structure of Bis(2,4-dicumylphenyl) pentaerythritol diphosphite (BDPD). The recovered OPE was mixed with PP resins, allowing it to improve its thermal properties and minimize its thermo-oxidative degradation. Organophosphorus flame retardant (OPE)' concentration in wastewater is alarming, ranging from 1179.0 to 4709.6 mg L-1. These exceed toxicity thresholds for aquatic organisms, emphasizing global environmental risks. Using a validated solid-phase extraction (SPE) technique with over 94% recovery, the study addresses concerns by removing organic contaminants and supporting circular economy principles. The high economic and environmental significance of recovering BDPD underscores the need for urgent global attention and intervention.

3.
Graefes Arch Clin Exp Ophthalmol ; 261(8): 2291-2299, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36884063

RESUMO

PURPOSE: To assess how eye axes and multifocal intraocular lens (MIOL) centration may impact the light distortion index (LDI) and ocular scatter index (OSI). METHODS: Fifty-eight subjects implanted with the trifocal MIOL Q-Flex M 640PM or Liberty 677MY (Medicontur) were included in this retrospective analysis. The following variables were collected with the Pentacam Wave (Oculus) considering the vertex normal as the coordinates center: chord-mu to the center of the pupil, chord-alpha to the geometrical center of the cornea, and chord-MIOL to the center of the diffractive ring. These measurements were correlated with OSI (HD Analyzer, Visiometrics) and LDI (light distortion analyzer, CEORLab). RESULTS: Chord-MIOL centroid was 0.12 mm at 62°, chord-mu was 0.09 mm at 174°, and chord-alpha was 0.38 mm at 188°. A relationship was found between OSI and LDI, rho = 0.58, p < 0.0005). No relationships were found between chord-mu or chord-alpha and the LDI or OSI, neither for the total magnitude, nor the decomposition in orthogonal components (p > 0.05). The LDI was significantly correlated with the temporal centration of the MIOL versus the vertex normal (rho = 0.32, p = 0.02). CONCLUSIONS: As opposed to what has been previously described, the temporal centration of the MIOL was related to a decrease in the LDI. Future studies with extreme values of the included variables are required to establish cut-offs for considering these variables as exclusion criteria in the implantation of a MIOL.


Assuntos
Catarata , Implante de Lente Intraocular , Lentes Intraoculares Multifocais , Humanos , Acuidade Visual , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos
4.
BMC Ophthalmol ; 23(1): 254, 2023 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-37280550

RESUMO

Cataract surgery has become a refractive procedure in which emmetropia is the goal, with the implantation of extended depth-of-focus or multifocal intraocular lenses (IOLs) being the commonly selected option to restore vision beyond the far distance. The selection criteria for implanting these lenses can differ from those for monofocal IOLs and even between technologies, as eye characteristics can affect postoperative visual performance. Corneal astigmatism is an eye characteristic that can affect visual performance differently, depending on the implanted IOL. The magnitude of corneal astigmatism, the tolerance of the IOL to this astigmatism, economic aspects, comorbidities, and the efficacy of astigmatism treatment are factors that can make surgeons' doubt as to what astigmatism treatment should be applied to each patient. This review aims to summarize the current evidence related to low astigmatism tolerance in presbyopia-correcting lenses, the efficacy achieved through corneal incisions, and their comparison with the implantation of toric IOLs.


Assuntos
Astigmatismo , Doenças da Córnea , Lentes Intraoculares , Facoemulsificação , Presbiopia , Humanos , Astigmatismo/cirurgia , Implante de Lente Intraocular/métodos , Presbiopia/complicações , Presbiopia/cirurgia , Acuidade Visual , Facoemulsificação/métodos , Doenças da Córnea/cirurgia , Desenho de Prótese
5.
BMC Ophthalmol ; 23(1): 101, 2023 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-36918799

RESUMO

BACKGROUND: New intraocular lenses (IOLs) have emerged since the originally coined monofocal and multifocal IOLs. The extended depth of focus (EDoF) and enhanced monofocal IOLs (mono-EDoF) that have appeared in the last decade have caused some confusion in their classification. The aim of this review was to summarize the outcomes provided by mono-EDOF IOLs and to determine which of the endpoints, described by the American National Standard (ANSI) for EDoF IOLs, are fulfilled. METHODS: The MEDLINE, EMBASE, and WEB OF SCIENCE databases were searched. Two independent reviewers screened the studies for inclusion and data extraction. The search strategy was limited to studies published between 2020 and 2022, but not by language. The results are presented as a narrative summary accompanied by tables, in alignment with the objectives of this scoping review. Compliance with the endpoints for clinical outcomes described in the American National Standard Z80.35-2018 (ANSI) for EDoF lenses was checked and additional endpoints were defined. RESULTS: Two systematic reviews, 13 laboratory, 21 clinical, and two mixed studies were included. Tecnis Eyhance was the mono-EDOF with the highest volume of evidence to date. Although laboratory studies included other IOLs, clinical evidence for them is still scarce, with only one study of IsoPure compared to a standard monofocal IOL. Evidence in comparison to EDoF lenses is also scarce, even for Tecnis Eyhance, with only three studies including this lens in comparison to an EDoF lens. After evaluation of the ANSI criteria, agreement was found in the failure for the increase in depth of field equal to or greater than 0.5 D for a visual acuity (VA) level of 0.2 logMAR and none of the studies supported that the median monocular VA at intermediate distance was at least 0.2 logMAR. CONCLUSIONS: Additional clinical evidence is required for other mono-EDOF IOLs beyond Tecnis Eyhance. Until the arrival of a standard classification, mono-EDOF should be better still classified as monofocal because the ANSI standards were not fully met.


Assuntos
Catarata , Lentes Intraoculares , Humanos , Desenho de Prótese , Acuidade Visual
6.
BMC Ophthalmol ; 23(1): 483, 2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38007433

RESUMO

Fuchs endothelial corneal dystrophy (FECD) is the leading indication for EK and may coexist with cataract and presbyopia. Notably, the outcomes of phacoemulsification in FECD patients are not as favorable as those in eyes without this condition. Historically, only monofocal intraocular lenses (IOLs) were recommended for these patients. However, recent reports have described the implantation of Premium-IOLs (such as Multifocal IOLs, Enhanced Depth of Focus IOLs, and Toric IOLs) in FECD eyes undergoing cataract surgery and Descemet membrane endothelial keratoplasty (DMEK). While the results are encouraging, they are not as optimal as those from unoperated eyes, especially when comparing simultaneous procedures to sequential ones. It's advised to perform the DMEK first to improve the accuracy of IOL calculations. Still, even successfully operated eyes may experience secondary graft failure or graft rejection after DMEK. The success rate of a secondary DMEK is typically lower than that of the initial procedure. Furthermore, if the postoperative thickness after DMEK is less than anticipated, laser enhancements might not be an option. There's a pressing need for more controlled and randomized clinical trials to ascertain the safety and effectiveness of Premium-IOLs for FECD eyes. This narrative review aims to collate evidence on the use of Premium IOL technologies in eyes receiving EK and to underscore key points for surgeons performing EK combined with cataract surgery.


Assuntos
Catarata , Transplante de Córnea , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Distrofia Endotelial de Fuchs , Lentes Intraoculares , Presbiopia , Humanos , Implante de Lente Intraocular/métodos , Lâmina Limitante Posterior , Presbiopia/cirurgia , Acuidade Visual , Transplante de Córnea/métodos , Distrofia Endotelial de Fuchs/cirurgia , Catarata/complicações , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior/métodos , Estudos Retrospectivos
7.
Eye Contact Lens ; 49(8): 319-328, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37418305

RESUMO

PURPOSE: To analyze critically the clinical trials on presbyopia correction with contact lenses (CLs) to investigate the quality of the research performed. METHODS: A search was performed in PubMed database on clinical trials evaluating the efficacy of the presbyopia correction with different CLs, including multifocal or simultaneous vision contact lenses (MCLs). After a comprehensive analysis of the relevant publications found, quality assessment of such publications was performed by means of Critical Appraisal Skills Programme checklist tool according to the five types of evaluations: MCL versus spectacles, MCL versus pinhole CLs, MCL versus monovision, comparison between MCL designs, and MCL versus extended depth of focus CLs. RESULTS: A total of 16 clinical trials were selected for evaluation. All evaluated studies addressed a clearly focused research question and were randomized, with a crossover design in most of the cases. Blinding was not possible in all cases due to the physical appearance of some of the CLs evaluated (pinhole or hybrid designs). Most of studies analyzed reported outcomes with complete data, providing the statistical tests used and the P -values, but some of the authors did not provide the statistical power associated to the sample size evaluated. The small sample size in some trials as well as the scarce information about the effect of addition on visual performance was the main limitations found in the peer-reviewed literature revised. CONCLUSIONS: There is a high-quality scientific evidence supporting the use of presbyopia-correcting CLs, with several randomized controlled clinical trials conducted to this date.


Assuntos
Lentes de Contato , Presbiopia , Humanos , Acuidade Visual , Óculos
8.
Int J Mol Sci ; 24(6)2023 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-36982471

RESUMO

In this study, the thermal degradation and pyrolysis of hospital plastic waste consisting of polyethylene (PE), polystyrene (PS), and polypropylene (PP) were investigated using TG-GC/MS. The identified molecules with the functional groups of alkanes, alkenes, alkynes, alcohols, aromatics, phenols, CO and CO2 were found in the gas stream from pyrolysis and oxidation, and are chemical structures with derivatives of aromatic rings. They are mainly related to the degradation of PS hospital waste, and the alkanes and alkenes groups originate mainly from PP and PE-based medical waste. The pyrolysis of this hospital waste did not show the presence of derivatives of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans, which is an advantage over classical incineration methodologies. CO, CO2, phenol, acetic acid and benzoic acid concentrations were higher in the gases from the oxidative degradation than in those generated in the pyrolysis with helium. In this article, we propose different pathways of reaction mechanisms that allow us to explain the presence of molecules with other functional groups, such as alkanes, alkenes, carboxylic acids, alcohols, aromatics and permanent gases.


Assuntos
Resíduos de Serviços de Saúde , Plásticos , Plásticos/química , Pirólise , Dióxido de Carbono , Colômbia , Poliestirenos/química , Polietileno/química , Polipropilenos , Gases , Alcanos
9.
Int J Mol Sci ; 24(18)2023 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-37762671

RESUMO

In this experimental-theoretical study, the effect of furan on Ziegler-Natta catalyst productivity, melt flow index (MFI), and mechanical properties of polypropylene were investigated. Through the analysis of the global and local reactivity of the reagents, it was determined that the furan acts as an electron donor. In contrast, the titanium of the ZN catalyst acts as an electron acceptor. It is postulated that this difference in reactivity could lead to forming a furan-titanium complex, which blocks the catalyst's active sites and reduces its efficiency for propylene polymerization. Theoretical results showed a high adsorption affinity of furan to the active site of the Ti catalyst, indicating that furan tends to bind strongly to the catalyst, thus blocking the active sites and decreasing the availability for propylene polymerization. The experimental data revealed that the presence of furan significantly reduced the productivity of the ZN catalyst by 10, 20, and 41% for concentrations of 6, 12.23, and 25.03 ppm furan, respectively. In addition, a proportional relationship was observed between the furan concentration and the MFI melt index of the polymer, where the higher the furan concentration, the higher the MFI. Likewise, the presence of furan negatively affected the mechanical properties of polypropylene, especially the impact Izod value, with percentage decreases of 9, 18, and 22% for concentrations of 6, 12.23, and 25.03 ppm furan, respectively.

10.
Molecules ; 28(13)2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-37446610

RESUMO

Currently, polypropylene (PP) is highlighted using sorbitol-based clarifying agents since these agents are high quality, low cost, and work as a barrier against moisture, which makes PP ideal for packaging food, beverages, and medical products, among others. The use of analytical methods capable of recovering these additives in wastewater streams and then reusing them in the PP clarification stage represents an innovative methodology that makes a substantial contribution to the circular economy of the PP production industry. In this study, a method of extraction and recovery of the Millad NX 8000 was developed. The additive was recovered using GC-MS and extracted with an activated carbon column plus glass fiber, using an injection molded sample, obtaining a recovery rate greater than 96%. TGA, DSC, and FTIR were used to evaluate the recovered additive's glass transitions and purity. The thermal degradation of the recovered additive was found to be between 340 and 420 °C, with a melting temperature of 246 °C, adopting the same behavior as the pure additive. In FTIR, the characteristic absorption peak of Millad NX 8000 was observed at 1073 cm-1, which indicates the purity of the extracted compound. Therefore, this work develops a new additive recovery methodology with high purity to regulate the crystallization behavior and of PP.


Assuntos
Sorbitol , Águas Residuárias , Polipropilenos/química , Polímeros , Embalagem de Produtos
11.
Molecules ; 28(7)2023 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-37049926

RESUMO

Industrial wastewater from petrochemical processes is an essential source of the synthetic phenolic phosphite antioxidant (Irgafos P-168), which negatively affects the environment. For the determination and analysis of Irgafos P-168, DSC, HPLC-MS, and FTIR methodologies were used. Solid phase extraction (SPE) proved to be the best technique for extracting Irgafos from wastewater. HPLC-MS and SPE determined the repeatability, reproducibility, and linearity of the method and the SPE of the standards and samples. The relative standard deviations, errors, and correlation coefficients for the repeatability and reproducibility of the calibration curves were less than 4.4% and 4.2% and greater than 0.99955, respectively. The analysis of variance (ANOVA), using the Fisher method with confidence in 95% of the data, did not reveal significant differences between the mentioned parameters. The removal of the antioxidant from the wastewater by SPE showed recovery percentages higher than 91.03%, and the chemical characterization of this antioxidant by FTIR spectroscopy, DSC, TGA, and MS showed it to be structurally the same as the Irgafos P-168 molecule. The recovered Irgafos was added to the polypropylene matrix, significantly improving its oxidation times. An OIT analysis, performed using DSC, showed that the recovered Irgafos-blended polypropylene (PP) demonstrated oxidative degradation at 8 min. With the addition of the Irgafos, the oxidation time was 13 min. This increases the polypropylene's useful life and minimizes the environmental impact of the wastewater.

12.
Molecules ; 28(3)2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36770708

RESUMO

Microplastic (MP) contamination has become a problem of great interest to the community at large. The detection of these particles in different ecosystems and foods has been the subject of study. However, the focus of these investigations has been on the identification and quantification of PM by DSC and Pyr-GC/MS and not on how they are transported to reach the air we breathe. In this study, the values of morphological parameters for plastic particles in a range between 1 and 2000 µm, present in the breathable air of 20 neighborhoods in the city of Cartagena, Colombia, were obtained to determine the characteristics that make these particles airborne. The values of parameters were obtained, such as roundness, sphericity, curvature, and the convexity of the particle, as well as its compactness and size, which influence its transport through the air and its ability to be ingested and inhaled. The data obtained in this study allows for simulations and the analysis of the behavior of microplastics once in the environment to predict future settlements. The DSC showed us the melting temperatures of PP, PE, PET, and PS, the Pyr-GC/MS showed the fragmentation patterns, and the presence of these MPs in the samples was confirmed.

13.
Molecules ; 28(5)2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36903250

RESUMO

The various chemicals in industrial wastewater can be beneficial for improving its circularity. If extraction methods are used to capture valuable components from the wastewater and then recirculate them throughout the process, the potential of the wastewater can be fully exploited. In this study, wastewater produced after the polypropylene deodorization process was evaluated. These waters remove the remains of the additives used to create the resin. With this recovery, contamination of the water bodies is avoided, and the polymer production process becomes more circular. The phenolic component was recovered by solid-phase extraction and HPLC, with a recovery rate of over 95%. FTIR and DSC were used to evaluate the purity of the extracted compound. After the phenolic compound was applied to the resin and its thermal stability was analyzed via TGA, the compound's efficacy was finally determined. The results showed that the recovered additive improves the thermal qualities of the material.

14.
Medicina (Kaunas) ; 59(3)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36984584

RESUMO

Suprachoroidal hemorrhage (SCH) is a rare and sight-threatening complication of various intraocular surgeries, including cataract surgery. Although the rate of SCH complicating cataract surgery has decreased in the era of phacoemulsification, most likely due to smaller self-sealing incisions and modern equipment, it remains a challenging complication to manage. The aim of this review is to summarize the current evidence of the pathophysiology and management of SCH complicating phaco surgery. A literature review was performed using the PubMed database searching for diagnosis, therapy, and management of SCH during phacoemulsification. The evidence available on the optimal management of this condition is low, and there is no consensus so far. An early diagnosis is thought to be essential to avoid progression to the devastating stage of expulsion of intraocular contents (expulsive hemorrhage). Sudden intraoperative anterior chamber shallowing, red reflex loss, and a significant increase in intraocular pressure are highly suspicious for this severe complication. A fundus examination and ocular ultrasound are crucial to confirm the diagnosis and, if it is confirmed, stabilize the globe immediately. The initial therapeutic approach includes aggressive topical and systemic medication focused on controlling ocular inflammation and intraocular pressure, whereas the timing and the indications of surgical intervention remain controversial.


Assuntos
Extração de Catarata , Catarata , Hemorragia da Coroide , Facoemulsificação , Humanos , Facoemulsificação/efeitos adversos , Hemorragia da Coroide/etiologia , Hemorragia da Coroide/terapia , Pressão Intraocular
15.
Int Ophthalmol ; 43(8): 2825-2832, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36871115

RESUMO

PURPOSE: To determine the cut-off points for age and metrics provided by cataract grading objective systems for which a reestablishment in contrast sensitivity (CS) is expected after multifocal intraocular lens (MIOL) implantation. METHODS: One hundred seven subjects were included in this retrospective analysis carried out during the screening for presbyopia and cataract surgery. Monocular distance corrected contrast sensitivity defocus curve (CSDC) and visual acuity were measured, and crystalline lens sclerosis was graded with three objective metrics: Ocular Scatter Index (OSI), Dysfunctional Lens Index (DLI) and Pentacam Nucleus Staging (PNS). A CS value of 0.8 logCS at far distance, following published literature on this matter, was selected to compute the cut-off that maximized the detection of eyes exceeding this value at the preoperative screening, either for age or objective metrics. RESULTS: The CDCS showed a stronger correlation than CDVA with objective grading methods, whereas all objective metrics were significantly correlated between them (p < 0.05). The cut-offs for age, OSI, DLI and PNS were ≤ 62, ≤ 1.25, ≥ 7.67 and ≤ 1, respectively. The OSI provided the highest area under the receiver operating characteristic curve (0.85) followed by the age (0.84), DLI (0.74) and PNS (0.63). CONCLUSIONS: Surgeons conducting clear lens exchange should communicate the possible distance CS loss after surgery with MIOL implantation according to the previous described cut-offs points. Age in combination with any cataract grading objective system is recommended to detect possible inconsistencies.


Assuntos
Catarata , Lentes Intraoculares , Lentes Intraoculares Multifocais , Facoemulsificação , Humanos , Sensibilidades de Contraste , Implante de Lente Intraocular/métodos , Estudos Retrospectivos , Catarata/diagnóstico , Desenho de Prótese
16.
BMC Ophthalmol ; 22(1): 341, 2022 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-35948879

RESUMO

BACKGROUND: The aim was to evaluate the safety and efficacy of a trifocal intraocular lens (IOL) for the correction of presbyopia and to assess patient satisfaction. METHODS: Records from three centres were reviewed to select presbyopic patients having undergone bilateral refractive lens exchange and implantation of the AT LISA tri 839MP multifocal IOL. Postoperatively, monocular and binocular distance, intermediate and near visual acuities, corrected and uncorrected, and subjective refraction were measured. Patients also completed a quality of life questionnaire. Safety evaluation included IOL stability and postoperative complications. RESULTS: 72 eyes (36 patients) were analysed. No clinically significant difference between pre- and postoperative corrected distance visual acuity (CDVA) was found for monocular or binocular measurements. Mean postoperative monocular CDVA was 0.02 ± 0.04 logMAR. Mean refractive values all improved statistically significantly compared with preoperative baseline (p ≤ 0.0064). Overall, 82.4% of eyes had spherical equivalent within ± 0.5 D and 97.1% within ± 1.0 D of emmetropia with a mean accuracy of -0.10 ± 0.41 D. Spectacle independence for distance, intermediate and near visual acuity was 87.5%, 84.4% and 78.1% respectively, and 78.1% of patients were satisfied with their postoperative, spectacle-free vision. Eight eyes received Nd:YAG laser treatment. No other IOL-related safety issues were reported. CONCLUSION: AT LISA tri 839MP multifocal IOL bilaterally implanted in presbyopic patients provided excellent distance, intermediate and near visual outcomes with very accurate correction of refraction. These results were associated with a high level of spectacle independence and patient satisfaction. TRIAL REGISTRATION: Trial registered on https://clinicaltrials.gov/ under the identification NCT03790592 (31/12/2018).


Assuntos
Catarata , Lentes Intraoculares , Presbiopia , Humanos , Satisfação do Paciente , Presbiopia/cirurgia , Estudos Prospectivos , Desenho de Prótese , Qualidade de Vida , Refração Ocular
17.
Int J Mol Sci ; 23(19)2022 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-36233019

RESUMO

For the synthesis of polymeric resins, it is of great importance to review the raw materials and the equipment to be used to avoid the presence of compounds that may affect the effectiveness of the polymerization and the characteristics of the plastic to be obtained. Iron oxide is a compound that can be present in reactors after maintenance due to the techniques used and the cleaning of this equipment, and it can affect the characteristics of the resins, reducing their quality. In this study, the presence of FeO in different concentrations was evaluated to determine its effects on the properties and pyrolysis of polypropylene resins by using X-ray refraction to determine the elements of the samples, evaluating thermal degradation by TGA, the variation in molecular weight by measuring the MFI, and the compounds obtained from pyrolysis by chromatography. The results showed that the thermal degradation decreased as the FeO concentration increased, while for the MFI, the relationship was directly proportional. The evaluation of the compounds obtained from pyrolysis showed an increase in the production of alcohols, alkynes, ketones, and acids, and a decrease in alkanes and alkenes, showing that FeO affects the properties of polypropylene and the compounds that are produced during pyrolysis.


Assuntos
Polipropilenos , Pirólise , Alcanos , Alcenos , Alcinos , Catálise , Compostos Férricos , Resíduos Industriais , Cetonas , Plásticos , Pós , Resinas Vegetais
18.
Int J Mol Sci ; 23(20)2022 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-36293003

RESUMO

During the production of polymer-grade propylene, different processes are used to purify this compound and ensure that it is of the highest quality. However, some impurities such as acetylene and methyl acetylene are difficult to remove, and some of these impurities may be present in the propylene used to obtain polypropylene, which may have repercussions on the process. This study evaluates the impact of these acetylene and methyl acetylene impurities on the productivity of the polypropylene synthesis process and on the mechanical and thermal properties of the material obtained through the synthesis of eight samples with different concentrations of acetylene and eight samples with different concentrations of acetylene. We discovered that for the first concentrations of both acetylene (2 and 3 ppm) and methyl acetylene (0.03 and 0.1), the MFI, thermal recording, and mechanical properties of the resin were unaffected by the variation of the fluidity index, thermal degradation by TGA, and mechanical properties such as resistance to tension, bending, and impact. However, when the concentration exceeded 14 ppm for methyl acetylene and 12 ppm for acetylene, the resistance of this resin began to decrease linearly. Regarding production, this was affected by the first traces of acetylene and methyl acetylene progressively decreasing.


Assuntos
Acetileno , Polipropilenos , Alcinos , Polímeros
19.
Molecules ; 27(15)2022 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-35956783

RESUMO

Because of its toxicity and impacts on the environment and human health, bisphenol A (BPA) has been controlled in numerous industrialized nations, increasing demand for bisphenol analogues (BP) for its replacement. However, the consequences of these chemicals on the environment and the health of persons exposed to their emissions are still being researched. The emissions from polypropylene manufacturing facilities in Colombia and Brazil were evaluated in this study, and the presence of bisphenol A and four BPs was detected among the gaseous compounds released, with total concentrations of BPs (∑BP) between 92 and 1565 ng g-1. As the melt flow index (MFI) of the polymer rises, so does the quantity of volatiles in its matrix that are eliminated during deodorization, indicating that the MFI and the amount of bisphenol released have a directly proportional connection.


Assuntos
Compostos Benzidrílicos , Polipropilenos , Compostos Benzidrílicos/química , Brasil , Humanos , Fenóis/química
20.
Int Ophthalmol ; 42(8): 2417-2424, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35132509

RESUMO

PURPOSE: To assess the influence in paired design studies of formulae comparison for intraocular lens (IOL) power calculation of using a single formula for deciding the implanted power with monofocal (mIOL) and multifocal (MIOL) lenses. DESIGN: Retrospective observational. METHODS: Ninety-six right eyes were retrospectively analyzed. Eyes were assigned in two independent groups, SG and HG, depending on the formula used for deciding the implanted power, SRK-T (n = 54) and Haigis (n = 42), respectively. Median absolute prediction error (MedAE) was evaluated between independent samples (SRK-T in SG vs Haigis in HG) and between paired samples (SRK-T vs Haigis in both SG and HG). Percentages of eyes within a specific range of prediction error (PE) were also calculated for both, the standard steps and the clinically relevant steps. RESULTS: MedAE difference was lower than 0.09 D between both formulas for the comparison of independent samples in the mIOL (p = 0.62) and MIOL (p = 0.83) groups. However, paired samples resulted in better MedAE for SRK-T in the SG (0.14 D lower, p = 0.003) and for Haigis in the HG (0.07 D lower, p = 0.015), but only in the mIOL group. These small differences were also manifested, but not reaching statistical significance (p > 0.05), in the percentage of eyes achieving a specific range of PE, especially in the mIOL group. CONCLUSIONS: A small superiority for the formula used for selecting the final implanted IOL power can appear in studies following current standards. These studies should clearly specify which formula was used for selecting the implanted power.


Assuntos
Lentes Intraoculares , Lentes Intraoculares Multifocais , Facoemulsificação , Biometria/métodos , Humanos , Implante de Lente Intraocular , Óptica e Fotônica , Refração Ocular , Estudos Retrospectivos , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA