RESUMO
BACKGROUND AND OBJECTIVES: Pathogen reduction (PR) technology may reduce the risk of transfusion-transmitted infections (TTIs), notably transfusion-transmitted bacterial infection (TTBI) associated with platelet concentrates (PCs). PR (amotosalen/UVA treatment) was implemented for all PCs transfused in France in November 2017. No bacterial detection was in place beforehand. The study aimed to assess the impact of PR PC on TTI and TTBI near-miss occurrences. MATERIALS AND METHODS: TTI and TTBI near-miss occurrences were compared before and after 100% PR implementation. The study period ran from 2013 to 2022. Over 300,000 PCs were transfused yearly. RESULTS: No PC-related transmission of human immunodeficiency virus, hepatitis C virus, hepatitis B virus and human T-cell lymphotropic virus was reported throughout the study period. PC-mediated hepatitis E virus and hepatitis A virus infections occurred irrespective of PR implementation. Mean PC-mediated TTBI occurrence before PR-PC implementation was 3/year (SD: 1; n = 15; 1/92,687 PC between 2013 and 2016) with a fatal outcome in two patients. Since PR implementation, one TTBI has been reported (day 4 PC, Bacillus cereus) (1/1,645,295 PC between 2018 and 2022; p < 0.001). Two PR PC quarantined because of a negative swirling test harboured bacteria: a day 6 PC in 2021 (B. cereus and Staphylococcus epidermidis) and a day 7 PC in 2022 (Staphylococcus aureus). Five similar occurrences with untreated PC were reported between 2013 and 2020. CONCLUSION: Transfusion of 100% PR PC resulted in a steep reduction in TTBI occurrence. TTBI may, however, still occur. Pathogen-reduced PC-related TTI involving non-enveloped viruses occurs as well.