Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Int J Immunogenet ; 42(5): 346-58, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26119888

RESUMO

Human leucocyte antigens (HLA) typing has been a challenge due to extreme polymorphism of the HLA genes and limitations of the current technologies and protocols used for their characterization. Recently, next-generation sequencing techniques have been shown to be a well-suited technology for the complete characterization of the HLA genes. However, a comprehensive assessment of the different platforms for HLA typing, describing the limitations and advantages of each of them, has not been presented. We have compared the Ion Torrent Personal Genome Machine (PGM) and Illumina MiSeq, currently the two most frequently used platforms for diagnostic applications, for a number of metrics including total output, quality score per position across the reads and error rates after alignment which can all affect the accuracy of HLA genotyping. For this purpose, we have used one homozygous and three heterozygous well-characterized samples, at HLA-A, HLA-B, HLA-C, HLA-DRB1 and HLA-DQB1. The total output of bases produced by the MiSeq was higher, and they have higher quality scores and a lower overall error rate than the PGM. The MiSeq also has a higher fidelity when sequencing through homopolymer regions up to 9 bp in length. The need to set phase between distant polymorphic sites was more readily achieved with MiSeq using paired-end sequencing of fragments that are longer than those obtained with PGM. Additionally, we have assessed the workflows of the different platforms for complexity of sample preparation, sequencer operation and turnaround time. The effects of data quality and quantity can impact the genotyping results; having an adequate amount of good quality data to analyse will be imperative for confident HLA genotyping. The overall turnaround time can be very comparable between the two platforms; however, the complexity of sample preparation is higher with PGM, while the actual sequencing time is longer with MiSeq.


Assuntos
Alelos , Genoma Humano , Técnicas de Genotipagem/métodos , Antígenos HLA/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Sequência de Bases , Linhagem Celular , Loci Gênicos , Homozigoto , Humanos , Alinhamento de Sequência
3.
Tissue Antigens ; 81(2): 124-5, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23231474

RESUMO

HLA-C*04:112 differs from HLA-C*04:01:01:01 by one nucleotide at position 270 resulting in an amino acid change, Lysine to Asparagine, at codon 66 of exon 2.


Assuntos
Alelos , Antígenos HLA-C/genética , Sequência de Bases , Éxons/genética , Humanos , Dados de Sequência Molecular , Alinhamento de Sequência
4.
Tissue Antigens ; 82(1): 72, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23621124

RESUMO

The new HLA-DQB1 allele most closely resembles DQB1*02:01:01, differing at a single position 141 (exon 2, codon 15.3).


Assuntos
Alelos , Cadeias beta de HLA-DQ/genética , Sequência de Bases , Éxons/genética , Humanos , Dados de Sequência Molecular
5.
6.
Tissue Antigens ; 77(3): 206-17, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21299525

RESUMO

The high degree of polymorphism at human leukocyte antigen (HLA) class I and class II loci makes high-resolution HLA typing challenging. Current typing methods, including Sanger sequencing, yield ambiguous typing results because of incomplete genomic coverage and inability to set phase for HLA allele determination. The 454 Life Sciences Genome Sequencer (GS FLX) next generation sequencing system coupled with conexio atf software can provide very high-resolution HLA genotyping. High-throughput genotyping can be achieved by use of primers with multiplex identifier (MID) tags to allow pooling of the amplicons generated from different individuals prior to sequencing. We have conducted a double-blind study in which eight laboratory sites performed amplicon sequencing using GS FLX standard chemistry and genotyped the same 20 samples for HLA-A, -B, -C, DPB1, DQA1, DQB1, DRB1, DRB3, DRB4, and DRB5 (DRB3/4/5) in a single sequencing run. The average sequence read length was 250 base pairs and the average number of sequence reads per amplicon was 672, providing confidence in the allele assignments. Of the 1280 genotypes considered, assignment was possible in 95% of the cases. Failure to assign genotypes was the result of researcher procedural error or the presence of a novel allele rather than a failure of sequencing technology. Concordance with known genotypes, in cases where assignment was possible, ranged from 95.3% to 99.4% for the eight sites, with overall concordance of 97.2%. We conclude that clonal pyrosequencing using the GS FLX platform and CONEXIO ATF software allows reliable identification of HLA genotypes at high resolution.


Assuntos
Antígenos HLA/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Análise de Sequência de DNA/tendências , Alelos , Sequência de Bases , Método Duplo-Cego , Características da Família , Genótipo , Antígenos HLA/análise , Humanos , Modelos Biológicos , Dados de Sequência Molecular , Estudos Multicêntricos como Assunto , Análise de Sequência de DNA/métodos , Software
7.
Hum Immunol ; 82(8): 593-599, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33875297

RESUMO

Atopic dermatitis (AD) is a common immune-medicated skin disease. Previous studies have explored the relationship between Human Leukocyte Antigen (HLA) allelic variation and AD with conflicting results. The aim was to examine HLA Class I genetic variation, specifically peptide binding groove variation, and associations with AD. A case-control study was designed to evaluate HLA class I allelic variation and binding pocket polymorphisms, using next generation sequencing on 464 subjects with AD and 388 without AD. Logistic regression was used to evaluate associations with AD by estimating odds ratios (95% confidence intervals). Significant associations were noted with susceptibility to AD (B*53:01) and protection from AD (A*01:01, A*02:01, B*07:02 and C*07:02). Evaluation of polymorphic residues in Class I binding pockets revealed six amino acid residues conferring protection against AD: A9F (HLA-A, position 9, phenylalanine) [pocket B/C], A97I [pocket C/E], A152V [pocket E], A156R [pocket D/E], B163E [pocket A] and C116S [pocket F]. These findings demonstrate that specific HLA class I components are associated with susceptibility or protection from AD. Individual amino acid residues are relevant to protection from AD and set the foundation for evaluating potential HLA Class I molecules in complex with peptides/antigens that may initiate or interfere with T-cell responses.


Assuntos
Dermatite Atópica/genética , Predisposição Genética para Doença , Variação Genética , Antígenos de Histocompatibilidade Classe I/genética , Alelos , Estudos de Casos e Controles , Dermatite Atópica/diagnóstico , Frequência do Gene , Estudos de Associação Genética , Genótipo , Antígenos de Histocompatibilidade Classe I/química , Humanos , Modelos Moleculares , Razão de Chances , Polimorfismo de Nucleotídeo Único , Conformação Proteica , Análise de Sequência de DNA , Relação Estrutura-Atividade
8.
HLA ; 87(3): 141-52, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26880737

RESUMO

This study presents performance specifications of an in-house developed human leukocyte antigen (HLA) typing assay using next-generation sequencing (NGS) on the Illumina MiSeq platform. A total of 253 samples, previously characterized for HLA-A, -B, -C, -DRB1 and -DQB1 were included in this study, which were typed at high-resolution using a combination of Sanger sequencing, sequence-specific primer (SSP) and sequence-specific oligonucleotide probe (SSOP) technologies and recorded at the two-field level. Samples were selected with alleles that cover a high percentage of HLA specificities in each of five different race/ethnic groups: European, African-American, Asian Pacific Islander, Hispanic and Native American. Sequencing data were analyzed by two software programs, Omixon's target and GenDx's NGSengine. A number of metrics including allele balance, sensitivity, specificity, precision, accuracy and remaining ambiguity were assessed. Data analyzed by the two software systems are shown independently. The majority of alleles were identical in the exonic sequences (third field) with both programs for HLA-A, -B, -C and -DQB1 in 97.7% of allele determinations. Among the remaining discrepant genotype calls at least one of the analysis programs agreed with the reference typing. Upon additional manual analysis 100% of the 2530 alleles were concordant with the reference HLA genotypes; the remaining ambiguities did not exceed 0.8%. The results demonstrate the feasibility and significant benefit of HLA typing by NGS as this technology is highly accurate, eliminates virtually all ambiguities, provides complete sequencing information for the length of the HLA gene and forms the basis for utilizing a single methodology for HLA typing in the immunogenetics labs.


Assuntos
Alelos , Genótipo , Antígenos HLA/classificação , Antígenos HLA/genética , Teste de Histocompatibilidade/métodos , Primers do DNA/síntese química , Sondas de DNA/síntese química , Antígenos HLA/imunologia , Sequenciamento de Nucleotídeos em Larga Escala , Teste de Histocompatibilidade/instrumentação , Teste de Histocompatibilidade/normas , Humanos , Reação em Cadeia da Polimerase , Grupos Raciais , Sensibilidade e Especificidade , Análise de Sequência de DNA , Software
9.
Hum Immunol ; 74(3): 325-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23246585

RESUMO

Many common and well-documented (CWD) HLA alleles have only been partially characterized. The DNA sequence of these incomplete alleles, as published in the IMGT/HLA database, is most often limited to exons that code for the extracellular domains of the mature protein. Here we describe the application of next-generation sequencing technology to obtain full length genomic sequence from a single long-range PCR amplicon for 15 common and well-documented HLA Class I alleles. This technology is well suited to fill in the gaps of the current HLA allele sequence database which is largely incomplete. A more comprehensive catalog of HLA allele sequences would be beneficial in the evaluation of mismatches in transplantation, studies of population genetics, the evolution of HLAs, regulatory mechanisms and HLA expression, and issues related to the genomic organization of the MHC.


Assuntos
Alelos , Biblioteca Genômica , Antígenos HLA/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Antígenos HLA-A/genética , Antígenos HLA-B/genética , Antígenos HLA-C/genética , Humanos , Dados de Sequência Molecular , Reação em Cadeia da Polimerase , Reprodutibilidade dos Testes
10.
Hum Immunol ; 71(10): 1033-42, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20603174

RESUMO

Human leukocyte antigen (HLA) typing has been a challenge for more than 50 years. Current methods (Sanger sequencing, sequence-specific primers [SSP], sequence-specific oligonucleotide probes [SSOP]) continue to generate ambiguities that are time-consuming and expensive to resolve. However, next-generation sequencing (NGS) overcomes ambiguity through the combination of clonal amplification, which provides on-phase sequence and a high level of parallelism, whereby millions of sequencing reads are produced enabling an expansion of the HLA regions sequenced. We explored HLA typing using NGS through a three-step process. First, HLA-A, -B, -C, -DRB1, and -DQB1 were amplified with long-range PCR. Subsequently, amplicons were sequenced using the 454 GS-FLX platform. Finally, sequencing data were analyzed with Assign-NG software. In a single experiment, four individual samples and two mixtures were sequenced producing >75 Mb of sequence from >300,000 individual sequence reads (average length, 244 b). The reads were aligned and covered 100% of the regions amplified. Allele assignment was 100% concordant with the known HLA alleles of our samples. Our results suggest this method can be a useful tool for complete genomic characterization of new HLA alleles and for completion of sequence for existing, partially sequenced alleles. NGS can provide complete, unambiguous, high-resolution HLA typing; however, further evaluation is needed to explore the feasibility of its routine use.


Assuntos
Teste de Histocompatibilidade/tendências , Análise de Sequência de DNA , Primers do DNA , Erros de Diagnóstico/prevenção & controle , Estudos de Viabilidade , Teste de Histocompatibilidade/métodos , Humanos , Reação em Cadeia da Polimerase , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise de Sequência de DNA/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA