Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
J Nucl Cardiol ; : 102052, 2024 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-39368659

RESUMO

BACKGROUND: Fluorodeoxyglucose positron emission tomography (FDG PET) with suppression of myocardial glucose utilization plays a pivotal role in diagnosing cardiac sarcoidosis. Reorientation of images to match perfusion datasets and myocardial segmentation enables consistent image scaling and quantification. However, such manual tasks are cumbersome. We developed a 3D U-Net deep-learning (DL) algorithm for automated myocardial segmentation in cardiac sarcoidosis FDG PET. METHODS: The DL model was trained on FDG PET scans from 316 patients with left ventricular contours derived from paired perfusion datasets. Qualitative analysis of clinical readability was performed to compare DL segmentation with the current automated method on a 50-patient test subset. Additionally, left ventricle displacement and angulation, as well as SUVmax sampling were compared with inter-user reproducibility results. A hybrid workflow was also investigated to accelerate study processing time. RESULTS: DL segmentation enhanced readability scores in over 90% of cases compared with the standard segmentation currently used in the software. DL segmentation performed similar to a trained technologist, surpassing standard segmentation for left ventricle displacement and angulation, as well as correlation of SUVmax. Using the DL segmentation as initial placement for manual segmentation significantly decreased the processing time. CONCLUSION: A novel DL-based automated segmentation tool markedly improves processing of cardiac sarcoidosis FDG PET. This tool yields optimized splash display of sarcoidosis FDG PET datasets with no user input and offers significant processing time improvement for manual segmentation of such datasets.

2.
Eur J Nucl Med Mol Imaging ; 51(1): 147-158, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37721579

RESUMO

PURPOSE: To establish requirements for normal databases for quantitative rubidium-82 (82Rb) PET MPI analysis with contemporary 3D PET/CT technology and reconstruction methods for maximizing diagnostic accuracy of total perfusion deficit (TPD), a combined metric of defect extent and severity, versus invasive coronary angiography. METHODS: In total, 1571 patients with 82Rb PET/CT MPI on a 3D scanner and stress static images reconstructed with and without time-of-flight (TOF) modeling were identified. An additional eighty low pre-test probability of disease (PTP) patients reported as normal were used to form separate sex-stratified and sex-independent iterative and TOF normal databases. 3D normal databases were applied to matched patient reconstructions to quantify TPD. Per-patient and per-vessel performance of 3D versus 2D PET normal databases was assessed with receiver operator characteristic curve analysis. Diagnostic accuracy was evaluated at optimal thresholds established from PTP patients. Results were compared against logistic regression modeling of TPD adjusted for clinical variables, and standard clinical interpretation. RESULTS: TPD diagnostic accuracy was significantly higher using 3D PET normal databases (per-patient: 80.1% for 3D databases, versus 74.9% and 77.7% for 2D database applied to iterative and TOF images respectively, p < 0.05). Differences in male and female normal distributions for 3D attenuation-corrected reconstructions were not clinically meaningful; therefore, sex-independent databases were used. Logistic regression modeling including TPD demonstrated improved performance over clinical reads. CONCLUSIONS: Normal databases tailored to 3D PET images provide significantly improved diagnostic accuracy for PET MPI evaluation with automated quantitative TPD. Clinical application of these techniques should be considered to support accurate image interpretation.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Masculino , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Imagem de Perfusão do Miocárdio/métodos , Sensibilidade e Especificidade , Angiografia Coronária , Tomografia Computadorizada de Emissão de Fóton Único/métodos
3.
Eur J Nucl Med Mol Imaging ; 51(1): 123-135, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37787848

RESUMO

BACKGROUND AND AIMS: Although treatment of ischemia-causing epicardial stenoses may improve symptoms of ischemia, current evidence does not suggest that revascularization improves survival. Conventional myocardial ischemia imaging does not uniquely identify diffuse atherosclerosis, microvascular dysfunction, or nonobstructive epicardial stenoses. We sought to evaluate the prognostic value of integrated myocardial flow reserve (iMFR), a novel noninvasive approach to distinguish the perfusion impact of focal atherosclerosis from diffuse coronary disease. METHODS: This study analyzed a large single-center registry of consecutive patients clinically referred for rest-stress myocardial perfusion positron emission tomography. Cox proportional hazards modeling was used to assess the association of two previously reported and two novel perfusion measures with mortality risk: global stress myocardial blood flow (MBF); global myocardial flow reserve (MFR); and two metrics derived from iMFR analysis: the extents of focal and diffusely impaired perfusion. RESULTS: In total, 6867 patients were included with a median follow-up of 3.4 years [1st-3rd quartiles, 1.9-5.0] and 1444 deaths (21%). Although all evaluated perfusion measures were independently associated with death, diffusely impaired perfusion extent (hazard ratio 2.65, 95%C.I. [2.37-2.97]) and global MFR (HR 2.29, 95%C.I. [2.08-2.52]) were consistently stronger predictors than stress MBF (HR 1.62, 95%C.I. [1.46-1.79]). Focally impaired perfusion extent (HR 1.09, 95%C.I. [1.03-1.16]) was only moderately related to mortality. Diffusely impaired perfusion extent remained a significant independent predictor of death when combined with global MFR (p < 0.0001), providing improved risk stratification (overall net reclassification improvement 0.246, 95%C.I. [0.183-0.310]). CONCLUSIONS: The extent of diffusely impaired perfusion is a strong independent and additive marker of mortality risk beyond traditional risk factors, standard perfusion imaging, and global MFR, while focally impaired perfusion is only moderately related to mortality.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Humanos , Constrição Patológica , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Perfusão , Isquemia , Imagem de Perfusão do Miocárdio/métodos , Circulação Coronária
4.
Eur J Nucl Med Mol Imaging ; 50(4): 1028-1033, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36401636

RESUMO

PURPOSE: Although SPECT myocardial perfusion imaging (MPI) is susceptible to artifacts from soft tissue attenuation, most scans are performed without attenuation correction. Deep learning-based attenuation corrected (DLAC) polar maps improved diagnostic accuracy for detection of coronary artery disease (CAD) beyond non-attenuation-corrected (NAC) polar maps in a large single center study. However, the generalizability of this approach to other institutions with different scanner models and protocols is uncertain. In this study, we evaluated the diagnostic performance of DLAC compared to NAC for detection of CAD as defined by invasive coronary angiography (ICA) in a large multi-center trial. METHODS: During the phase 3 flurpiridaz multi-center diagnostic clinical trial, conducted over 74 international sites, patients with known or suspected CAD who were referred for a clinically indicated ICA were enrolled. Using receiver operating characteristic (ROC) analysis, we evaluated the detectability of obstructive CAD, defined by quantitative coronary angiography by a core laboratory, using total perfusion deficit (TPD) as an integrated measure of defect extent and severity on DLAC polar maps compared to NAC polar maps. This was also compared against the visual scoring of three expert core lab readers. RESULTS: Out of 755 patients, 722 (69% male) had evaluable SPECT and ICA for this study. ROC analysis demonstrated significant improvement in detecting per-patient obstructive CAD with DLAC over NAC with area under the curve (AUC) of 0.752 (95% CI: 0.711-0.792) for DLAC compared to 0.717 (0.675-0.759) for NAC (p value = 0.016). Compared to the consensus of expert readers AUC = 0.743 (0.701-0.784), DLAC was comparable (p value = 0.913), whereas NAC underperformed (p value = 0.051). CONCLUSION: DL-based attenuation correction improves diagnostic performance of SPECT MPI for detecting CAD in data from a large multi-center clinical trial regardless of SPECT camera model or protocol. TRIAL REGISTRATION: A Phase 3 Multi-center Study to Assess PET Imaging of Flurpiridaz F 18 Injection in Patients With CAD, ClinicalTrials.gov Identifier: NCT01347710, registered on 4 May 2011. https://clinicaltrials.gov/ct2/show/study/NCT01347710.


Assuntos
Doença da Artéria Coronariana , Aprendizado Profundo , Imagem de Perfusão do Miocárdio , Humanos , Masculino , Feminino , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia Coronária/métodos
5.
Eur J Nucl Med Mol Imaging ; 51(1): 136-146, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37807004

RESUMO

PURPOSE: Distinguishing obstructive epicardial coronary artery disease (CAD) from microvascular dysfunction and diffuse atherosclerosis would be of immense benefit clinically. However, quantitative measures of absolute myocardial blood flow (MBF) integrate the effects of focal epicardial stenosis, diffuse atherosclerosis, and microvascular dysfunction. In this study, MFR and relative perfusion quantification were combined to create integrated MFR (iMFR) which was evaluated using data from a large clinical registry and an international multi-center trial and validated against invasive coronary angiography (ICA). METHODS: This study included 1,044 clinical patients referred for 82Rb rest/stress positron emission tomography myocardial perfusion imaging and ICA, along with 231 patients from the Flurpiridaz 301 trial (clinicaltrials.gov NCT01347710). MFR and relative perfusion quantification were combined to create an iMFR map. The incremental value of iMFR was evaluated for diagnosis of obstructive stenosis, adjusted for patient demographics and pre-test probability of CAD. Models for high-risk anatomy (left main or three-vessel disease) were also constructed. RESULTS: iMFR parameters of focally impaired perfusion resulted in best fitting diagnostic models. Receiver-operating characteristic analysis showed a slight improvement compared to standard quantitative perfusion approaches (AUC 0.824 vs. 0.809). Focally impaired perfusion was also associated with high-risk CAD anatomy (OR 1.40 for extent, and OR 2.40 for decreasing mean MFR). Diffusely impaired perfusion was associated with lower likelihood of obstructive CAD, and, in the absence of transient ischemic dilation (TID), with lower likelihood of high-risk CAD anatomy. CONCLUSIONS: Focally impaired perfusion extent derived from iMFR assessment is a powerful incremental predictor of obstructive CAD while diffusely impaired perfusion extent can help rule out obstructive and high-risk CAD in the absence of TID.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Humanos , Constrição Patológica , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Imagem de Perfusão do Miocárdio/métodos , Tomografia por Emissão de Pósitrons/métodos , Estudos Multicêntricos como Assunto , Ensaios Clínicos como Assunto
6.
Eur J Nucl Med Mol Imaging ; 49(9): 3140-3149, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35312837

RESUMO

PURPOSE: Myocardial perfusion imaging (MPI) using single-photon emission computed tomography (SPECT) is widely used for coronary artery disease (CAD) evaluation. Although attenuation correction is recommended to diminish image artifacts and improve diagnostic accuracy, approximately 3/4ths of clinical MPI worldwide remains non-attenuation-corrected (NAC). In this work, we propose a novel deep learning (DL) algorithm to provide "virtual" DL attenuation-corrected (DLAC) perfusion polar maps solely from NAC data without concurrent computed tomography (CT) imaging or additional scans. METHODS: SPECT MPI studies (N = 11,532) with paired NAC and CTAC images were retrospectively identified. A convolutional neural network-based DL algorithm was developed and trained on half of the population to predict DLAC polar maps from NAC polar maps. Total perfusion deficit (TPD) was evaluated for all polar maps. TPDs from NAC and DLAC polar maps were compared to CTAC TPDs in linear regression analysis. Moreover, receiver-operating characteristic analysis was performed on NAC, CTAC, and DLAC TPDs to predict obstructive CAD as diagnosed from invasive coronary angiography. RESULTS: DLAC TPDs exhibited significantly improved linear correlation (p < 0.001) with CTAC (R2 = 0.85) compared to NAC vs. CTAC (R2 = 0.68). The diagnostic performance of TPD was also improved with DLAC compared to NAC with an area under the curve (AUC) of 0.827 vs. 0.780 (p = 0.012) with no statistically significant difference between AUC for CTAC and DLAC. At 88% sensitivity, specificity was improved by 18.9% for DLAC and 25.6% for CTAC. CONCLUSIONS: The proposed DL algorithm provided attenuation correction comparable to CTAC without the need for additional scans. Compared to conventional NAC perfusion imaging, DLAC significantly improved diagnostic accuracy.


Assuntos
Doença da Artéria Coronariana , Aprendizado Profundo , Imagem de Perfusão do Miocárdio , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio/métodos , Perfusão , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único
7.
J Nucl Cardiol ; 29(5): 2612-2623, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34448094

RESUMO

BACKGROUND: As clinical use of myocardial blood flow (MBF) increases, dynamic series are becoming part of the typical workflow. The methods and parameters used to reconstruct these series require investigation to ensure accurate quantification. METHODS: Fifty-nine rest/stress dynamic 82Rb PET studies, acquired on a Biograph mCT, from a combination of normal volunteers and low-likelihood patients were reconstructed with and without time of flight (TOF) for varying iterations and processed to obtain relative perfusion and MBF polar maps. Regional values from mean polar maps were fit to a linear mixed-effect model to quantify convergence and select the optimal number of iterations. RESULTS: TOF reconstructions converged faster and yielded more uniform relative perfusion polar maps. However, the stress MBF distribution for TOF reconstructions was more heterogeneous, with a higher-intensity septal wall. This phenomenon requires further investigation, with right ventricle blood pool spillover possibly having an effect. Optimal reconstructions were defined as 5-iteration non-TOF (24-subset) reconstructions and 3-iteration TOF (21-subset) reconstructions. CONCLUSION: Optimal cardiac reconstructions were identified for non-TOF and TOF reconstructions of dynamic series. TOF reconstruction presents as the more accurate method, given the more uniform relative perfusion distribution.


Assuntos
Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Circulação Coronária , Humanos , Imagem de Perfusão do Miocárdio/métodos , Distribuição Normal , Perfusão , Tomografia por Emissão de Pósitrons/métodos
8.
J Nucl Cardiol ; 29(5): 2078-2089, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34426935

RESUMO

BACKGROUND: PET myocardial flow reserve (MFR) has established diagnostic and prognostic value. Technological advances have now enabled SPECT MFR quantification. We investigated whether SPECT MFR precision is sufficient for clinical categorization of patients. METHODS: Validation studies vs invasive flow measurements and PET MFR were reviewed to determine global SPECT MFR thresholds. Studies vs PET and a SPECT MFR repeatability study were used to establish imprecision in SPECT MFR measurements as the standard deviation of the difference between SPECT and PET MFR, or test-retest SPECT MFR. Simulations were used to evaluate the impact of SPECT MFR imprecision on confidence of clinically relevant categorization. RESULTS: Based on validation studies, the typical PET MFR categories were used for SPECT MFR classification (< 1.5, 1.5-2.0, > 2.0). Imprecision vs PET MFR ranged from 0.556 to 0.829, and test-retest imprecision was 0.781-0.878. Simulations showed correct classification of up to only 34% of patients when 1.5 ≤ true MFR ≤ 2.0. Categorization with high confidence (> 80%) was only achieved for extreme MFR values (< 1.0 or > 2.5), with correct classification in only 15% of patients in a typical lab with MFR of 1.8 ± 0.5. CONCLUSIONS: Current SPECT-derived estimates of MFR lack precision and require further optimization for clinical risk stratification.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Circulação Coronária , Humanos , Imagem de Perfusão do Miocárdio/métodos , Miocárdio , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
9.
J Nucl Cardiol ; 29(5): 2262-2270, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34780036

RESUMO

BACKGROUND: 13N-ammonia and 18F-flurpiridaz require longer delays between rest and stress studies to allow for decay, lowering clinical throughput. In this study, we investigated the impact of residual subtraction on MBF and MFR estimates, as well as its effects on diagnostic accuracy. METHODS: We retrospectively analyzed 63 patients who underwent a dynamic ammonia rest/stress study and 231 patients from the flurpiridaz 301 trial. Residual subtraction was performed by subtracting the mean pre-injection activity in each sampled region from that region's time activity curve. Corrected and uncorrected MBF and MFR were analyzed. Diagnostic accuracy was compared to quantitative coronary angiograms (QCA) for the flurpiridaz population. RESULTS: With delays between injections above 3 half-lives, and a doubled stress dose, residual activity did not meaningfully increase ammonia MBF (< 5%). For shorter injection delays, stress MBF was overestimated by 13.6% ± 5.0% (P < .001). Residual activity had a large effect on flurpiridaz stress MBF, overestimating it by 37.9% ± 23.2% (P < .001). Comparison to QCA showed a significant improvement in AUC with residual subtraction (from 0.748 to 0.831, P = .001). MFR yielded similar results. CONCLUSIONS: Accounting for residual activity has a marked impact on stress MBF and MFR and improves diagnostic accuracy relative to QCA.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Amônia , Ensaios Clínicos como Assunto , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária/fisiologia , Humanos , Imagem de Perfusão do Miocárdio/métodos , Tomografia por Emissão de Pósitrons/métodos , Estudos Retrospectivos
10.
Eur J Nucl Med Mol Imaging ; 48(12): 3835-3846, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33982174

RESUMO

PURPOSE: Clinical measurement of myocardial blood flow (MBF) has emerged as an important component of routine PET-CT assessment of myocardial perfusion in patients with known or suspected coronary artery disease. Although multiple society guidelines recommend patient-specific dosing, there is a lack of studies evaluating the efficacy of patient-specific dosing for quantitative MBF accuracy. METHODS: Two patient-specific dosing protocols (weight- and BMI-adjusted) were retrospectively evaluated in 435 consecutive clinical patients referred for PET myocardial perfusion assessment. MBF was estimated at rest and after regadenoson-induced hyperemia. The effect of dosing protocol on dose reduction, PET scanner saturation, relative perfusion, and image quality was compared. The effect of PET saturation on the accuracy of MBF and myocardial flow reserve (MFR) in remote myocardium was assessed with multivariable linear regression. RESULTS: BMI-adjusted dosing was associated with lower administered 82Rb activities (1036.0 ± 274 vs. 1147 ± 274 MBq, p = 0.003) and lower PET scanner saturation incidence (28 vs. 38%, p = 0.006) and severity (median saturation severity index 0.219 ± 0.33 vs. 0.397 ± 0.59%, p = 0.018) compared to weight-adjusted dosing. PET saturation that occurred with either dosing protocol was moderate and resulted in modest remote MBF and MFR biases ranging from 2 to 9% after adjusting for patient age, sex, BMI, rate-pressure product, and LV ejection fraction. No adverse effects of BMI dose adjustment were observed in relative perfusion assessment or image quality. CONCLUSIONS: Patient-specific dosing according to BMI is an effective method for guideline-directed dose reduction while maintaining image quality and accuracy for routine MBF and MFR quantification.


Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
11.
J Nucl Cardiol ; 28(5): 2313-2329, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-32002847

RESUMO

BACKGROUND: 18F-Flurpiridaz is a promising investigational radiotracer for PET myocardial perfusion imaging with favorable properties for quantification of myocardial blood flow (MBF). We sought to validate the incremental diagnostic value of absolute MBF quantification in a large multicenter trial against quantitative coronary angiography. METHODS: We retrospectively analyzed a subset of patients (N = 231) from the first phase 3 flurpiridaz trial (NCT01347710). Dynamic PET data at rest and pharmacologic stress were fit to a previously validated 2-tissue-compartment model. Absolute MBF and myocardial flow reserve (MFR) were compared with coronary artery disease severity quantified by invasive coronary angiography on a per-patient and per-vessel basis. RESULTS: Stress MBF per-vessel accurately identified obstructive disease (c-index 0.79) and progressively declined with increasing stenosis severity (2.35 ± 0.71 in patients without CAD; 1.92 ± 0.49 in non-obstructed territories of CAD patients; and 1.54 ± 0.50 in diseased territories, P < 0.05). MFR similarly declined with increasing stenosis severity (3.03 ± 0.94; 2.69 ± 0.95; and 2.33 ± 0.86, respectively, P < 0.05). In multivariable logistic regression modeling, stress MBF and MFR provided incremental diagnostic value beyond patient characteristics and relative perfusion analysis. CONCLUSIONS: Clinical myocardial blood flow measurement with 18F-flurpiridaz cardiac PET shows promise for routine application.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Piridazinas , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
12.
J Nucl Cardiol ; 28(1): 115-127, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33067750

RESUMO

Quantitative analysis has been applied extensively to image processing and interpretation in nuclear cardiology to improve disease diagnosis and risk stratification. This is Part 2 of a two-part continuing medical education article, which will review the potential clinical role for emerging quantitative analysis tools. The article will describe advanced methods for quantifying dyssynchrony, ventricular function and perfusion, and hybrid imaging analysis. This article discusses evolving methods to measure myocardial blood flow with positron emission tomography and single-photon emission computed tomography. Novel quantitative assessments of myocardial viability, microcalcification and in patients with cardiac sarcoidosis and cardiac amyloidosis will also be described. Lastly, we will review the potential role for artificial intelligence to improve image analysis, disease diagnosis, and risk prediction. The potential clinical role for all these novel techniques will be highlighted as well as methods to optimize their implementation.


Assuntos
Cardiopatias/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Imagem Multimodal , Imagem de Perfusão do Miocárdio , Humanos
13.
J Nucl Cardiol ; 28(1): 295-299, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-31515758

RESUMO

BACKGROUND: Although N13-ammonia has favorable properties among FDA approved radiotracers, complexity of implementation has limited its use. We describe the initial patient experience of N13-ammonia PET imaging using a compact N13-ammonia production system. METHODS: N13 was produced using the ION-12SC, a 12MeV, 10uA superconducting minimally shielded cyclotron, and reduced to N13-ammonia in an automated multi-use purification unit. Patients were power injected with 9.3 ± 1.1 mCi (344.1 ± 40.7 MBq) of N13-ammonia for rest imaging, and 18.8 ± 0.9 mCi (695.6 ± 33.3 MBq) of N13-ammonia was injected at peak hyperemia for stress testing. Images were interpreted for relative perfusion, left ventricular volumes/function, blood flow quantification, and scored for image quality. RESULTS: In total 97 patients underwent 98 N13-ammonia PET scans (32 rest only/65 rest-stress/1 stress only). Image quality was 91.8% good or excellent. None were poor/non-diagnostic. Study durations were acceptable. Tracer related radiation dosimetry to patients was 0.7 ± 0.1 mSv (rest only), and 2.1 ± 0.1 mSv (rest-stress). CONCLUSION: Clinical N13-ammonia production by the Ionetix ION-12SC delivers high quality myocardial PET perfusion images in a rapid protocol.


Assuntos
Amônia , Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Radioisótopos de Nitrogênio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Ciclotrons , Composição de Medicamentos/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Supercondutividade
14.
J Nucl Cardiol ; 27(1): 189-201, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31654215

RESUMO

Single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) has attained widespread clinical acceptance as a standard of care for patients with known or suspected coronary artery disease (CAD). A significant contribution to this success has been the use of computer techniques to provide objective quantitative assessment in the standardization of the interpretation of these studies. Software platforms have been developed as a pipeline to provide the quantitative algorithms researched, developed and validated to be clinically useful so diagnosticians everywhere can benefit from these tools. The goal of this CME article (PART 1) is to describe the many quantitative tools that are clinically established and more importantly how clinicians should use them routinely in the interpretation, clinical management and therapy guidance of patients with CAD.


Assuntos
Cardiologia , Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Medicina Nuclear , Tomografia Computadorizada de Emissão de Fóton Único , Algoritmos , Humanos , Software
15.
J Nucl Cardiol ; 27(4): 1104-1113, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31646469

RESUMO

BACKGROUND: Clinical use of myocardial blood flow (MBF) and flow reserve (MFR) is increasing. Motion correction is necessary to obtain accurate results but can introduce variability when performed manually. We sought to reduce that variability with an automated motion-correction algorithm. METHODS: A blinded randomized controlled trial of two technologists was performed on the motion correction of 100 dynamic 82Rb patient studies comparing manual motion correction with manual review and adjustment of automated motion correction. Inter-rater variability between technologists for MBF and MFR was the primary outcome with comparison made by analysis of the limits of agreement. Processing time was the secondary outcome. RESULTS: Limits of agreements between the two technologists decreased significantly for both MBF and MFR, going from [- 0.22, 0.22] mL/min/g and [- 0.31, 0.36] to [- 0.12, 0.15] mL/min/g and [- 0.15, 0.18], respectively (both P < .002). In addition, the average time spent on motion correcting decreased by 1 min per study from 5:21 to 4:21 min (P = .001). CONCLUSIONS: In this randomized controlled trial, the use of automated motion correction significantly decreased inter-user variability and reduced processing time.


Assuntos
Circulação Coronária/fisiologia , Imagem de Perfusão do Miocárdio/métodos , Radioisótopos de Rubídio , Adulto , Idoso , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade
16.
J Nucl Cardiol ; 27(3): 849-861, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31236832

RESUMO

BACKGROUND: With appropriate protocols, F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) can visualize myocardial inflammation. Optimal protocols and normative myocardial FDG uptake values are not well-established. METHODS: We evaluated 111 patients referred for inflammation cardiac FDG PET/CT. Patients followed a low-carbohydrate, high-fat diet for 36 hours before imaging and received unfractionated heparin. Glucose and fatty acid metabolism biomarkers were obtained. Mean blood pool and maximum myocardial uptake (SUVmean, SUVmax) were measured, avoiding areas of abnormal FDG uptake or spillover. RESULTS: Adequate suppression of myocardial FDG uptake occurred in 95% of patients (n = 106). Myocardial SUVmax was significantly below background blood pool SUVmean: septal myocardial to blood pool ratio 0.75 (95% CI 0.73-0.77; P < 0.001); lateral myocardial to blood pool ratio 0.70 (95% CI 0.68-0.72; P < 0.001). Glucose, insulin, and C-peptide correlated to blood pool SUVmean (Spearman rs = 0.39, P < 0.01; rs = 0.40, P < 0.01; rs = 0.35, P < 0.01) and myocardial SUVmax (Spearman rs = 0.31, P < 0.01; rs = 0.31, P < 0.01; rs = 0.26, P < 0.01). Fatty acid metabolism biomarkers did not correlate to myocardial SUVmax. CONCLUSIONS: Patients following intensive metabolic preparation have myocardial FDG SUVmax below background SUVmean. Biomarkers of glucose metabolism modestly correlate to FDG uptake.


Assuntos
Fluordesoxiglucose F18 , Glucose/metabolismo , Coração/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Idoso , Biomarcadores/metabolismo , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Inflamação , Masculino , Pessoa de Meia-Idade , Miocárdio/metabolismo , Peptídeos/química , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Estudos Retrospectivos
17.
J Nucl Cardiol ; 27(5): 1547-1562, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-30191438

RESUMO

BACKGROUND: Left atrial (LA) remodeling is associated with structural, electric, and metabolic LA changes. Integrated evaluation of these features in vivo is lacking. METHODS: Patients undergoing 18F-fluorodeoxyglucose (FDG) PET-CT during a hyperinsulinemic-euglycemic clamp were classified into sinus rhythm (SR), paroxysmal AF (PAF), and persistent AF (PerAF). The LA was semiautomatically segmented, and global FDG uptake was quantified using standardized uptake values (SUVmax and SUVmean) in gated, attenuation-corrected images and normalized to LA blood pool activity. Regression was used to relate FDG data to AF burden and critical patient factors. Continuous variables were compared using t-tests or Mann-Whitney tests. RESULTS: 117 patients were included (76% men, age 66.4 ± 11.0, ejection fraction (EF) 25[22-35]%) including those with SR (n = 48), PAF (n = 55), and PerAF (n = 14). Patients with any AF had increased SUVmean (2.3[1.5-2.4] vs 2.0[1.5-2.5], P = 0.006), SUVmax (4.4[2.8-6.7] vs 3.2[2.3-4.3], P < 0.001), uptake coefficient of variation (CoV) 0.28[0.22-0.40] vs 0.25[0.2-0.33], P < 0.001), and hypometabolic scar (32%[14%-53%] vs 16.5%[0%-38.5%], P = 0.01). AF burden correlated with increased SUVmean, SUVmax, CoV, and scar independent of age, gender, EF, or LA size (P < 0.03 for all). CONCLUSIONS: LA structure and metabolism can be assessed using FDG PET/CT. Greater AF burden correlates with the increased LA metabolism and scar.


Assuntos
Remodelamento Atrial/fisiologia , Técnicas de Imagem Cardíaca/métodos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/metabolismo , Feminino , Fluordesoxiglucose F18/farmacocinética , Átrios do Coração/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto
18.
J Nucl Cardiol ; 27(6): 1982-1998, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-30406609

RESUMO

BACKGROUND: Patient motion can lead to misalignment of left ventricular (LV) volumes-of-interest (VOIs) and subsequently inaccurate quantification of myocardial blood flow (MBF) and flow reserve (MFR) from dynamic PET myocardial perfusion images. We aimed to develop an image-based 3D-automated motion-correction algorithm that corrects the full dynamic sequence for translational motion, especially in the early blood phase frames (~ first minute) where the injected tracer activity is transitioning from the blood pool to the myocardium and where conventional image registration algorithms have had limited success. METHODS: We studied 225 consecutive patients who underwent dynamic rest/stress rubidium-82 chloride (82Rb) PET imaging. Dynamic image series consisting of 30 frames were reconstructed with frame durations ranging from 5 to 80 seconds. An automated algorithm localized the RV and LV blood pools in space and time and then registered each frame to a tissue reference image volume using normalized gradient fields with a modification of a signed distance function. The computed shifts and their global and regional flow estimates were compared to those of reference shifts that were assessed by three physician readers. RESULTS: The automated motion-correction shifts were within 5 mm of the manual motion-correction shifts across the entire sequence. The automated and manual motion-correction global MBF values had excellent linear agreement (R = 0.99, y = 0.97x + 0.06). Uncorrected flows outside of the limits of agreement with the manual motion-corrected flows were brought into agreement in 90% of the cases for global MBF and in 87% of the cases for global MFR. The limits of agreement for stress MBF were also reduced twofold globally and by fourfold in the RCA territory. CONCLUSIONS: An image-based, automated motion-correction algorithm for dynamic PET across the entire dynamic sequence using normalized gradient fields matched the results of manual motion correction in reducing bias and variance in MBF and MFR, particularly in the RCA territory.


Assuntos
Circulação Coronária/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Imagem de Perfusão do Miocárdio/métodos , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos de Rubídio , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Reconhecimento Automatizado de Padrão , Rubídio , Software
19.
J Nucl Cardiol ; 26(6): 1918-1929, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-29572594

RESUMO

BACKGROUND: Patient motion can lead to misalignment of left ventricular volumes of interest and subsequently inaccurate quantification of myocardial blood flow (MBF) and flow reserve (MFR) from dynamic PET myocardial perfusion images. We aimed to identify the prevalence of patient motion in both blood and tissue phases and analyze the effects of this motion on MBF and MFR estimates. METHODS: We selected 225 consecutive patients that underwent dynamic stress/rest rubidium-82 chloride (82Rb) PET imaging. Dynamic image series were iteratively reconstructed with 5- to 10-second frame durations over the first 2 minutes for the blood phase and 10 to 80 seconds for the tissue phase. Motion shifts were assessed by 3 physician readers from the dynamic series and analyzed for frequency, magnitude, time, and direction of motion. The effects of this motion isolated in time, direction, and magnitude on global and regional MBF and MFR estimates were evaluated. Flow estimates derived from the motion corrected images were used as the error references. RESULTS: Mild to moderate motion (5-15 mm) was most prominent in the blood phase in 63% and 44% of the stress and rest studies, respectively. This motion was observed with frequencies of 75% in the septal and inferior directions for stress and 44% in the septal direction for rest. Images with blood phase isolated motion had mean global MBF and MFR errors of 2%-5%. Isolating blood phase motion in the inferior direction resulted in mean MBF and MFR errors of 29%-44% in the RCA territory. Flow errors due to tissue phase isolated motion were within 1%. CONCLUSIONS: Patient motion was most prevalent in the blood phase and MBF and MFR errors increased most substantially with motion in the inferior direction. Motion correction focused on these motions is needed to reduce MBF and MFR errors.


Assuntos
Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Miocárdio/patologia , Tomografia por Emissão de Pósitrons , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Radioisótopos de Rubídio
20.
J Nucl Cardiol ; 26(2): 374-386, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30809755

RESUMO

BACKGROUND: 82Rb kinetics may distinguish scar from viable but dysfunctional (hibernating) myocardium. We sought to define the relationship between 82Rb kinetics and myocardial viability compared with conventional 82Rb and 18F-fluorodeoxyglucose (FDG) perfusion-metabolism PET imaging. METHODS: Consecutive patients (N = 120) referred for evaluation of myocardial viability prior to revascularization and normal volunteers (N = 37) were reviewed. Dynamic 82Rb 3D PET data were acquired at rest. 18F-FDG 3D PET data were acquired after metabolic preparation using a standardized hyperinsulinemic-euglycemic clamp. 82Rb kinetic parameters K1, k2, and partition coefficient (KP) were estimated by compartmental modeling RESULTS: Segmental 82Rb k2 and KP differed significantly between scarred and hibernating segments identified by Rb-FDG perfusion-metabolism (k2, 0.42 ± 0.25 vs. 0.22 ± 0.09 min-1; P < .0001; KP, 1.33 ± 0.62 vs. 2.25 ± 0.98 ml/g; P < .0001). As compared to Rb-FDG analysis, segmental Rb KP had a c-index, sensitivity and specificity of 0.809, 76% and 84%, respectively, for distinguishing hibernating and scarred segments. Segmental k2 performed similarly, but with lower specificity (75%, P < .001) CONCLUSIONS: In this pilot study, 82Rb kinetic parameters k2 and KP, which are readily estimated using a compartmental model commonly used for myocardial blood flow, reliably differentiated hibernating myocardium and scar. Further study is necessary to evaluate their clinical utility for predicting benefit after revascularization.


Assuntos
Cicatriz/diagnóstico por imagem , Fluordesoxiglucose F18 , Coração/diagnóstico por imagem , Miocárdio/patologia , Tomografia por Emissão de Pósitrons , Radioisótopos de Rubídio , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento Tridimensional , Insulina/metabolismo , Cinética , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio , Revascularização Miocárdica , Miocárdio Atordoado , Projetos Piloto , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA