Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 133
Filtrar
1.
J Prosthodont ; 33(3): 281-287, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37014263

RESUMO

PURPOSE: This study aimed to assess the fracture resistance of monolithic zirconia-reinforced lithium silicate laminate veneers (LVs) fabricated on various incisal preparation designs. MATERIALS AND METHODS: Sixty maxillary central incisors with various preparation designs were 3D-printed, 15 each, including preparation for: (1) LV with feathered-edge design; (2) LV with butt-joint design; (3) LV with palatal chamfer; and (4) full-coverage crown. Restorations were then designed and manufactured from zirconia-reinforced lithium silicate (ZLS) following the contour of a pre-operation scan. Restorations were bonded to the assigned preparation using resin cement and following the manufacturer's instructions. Specimens were then subjected to 10,000 thermocycles at 5 to 55°C with a dwell time of 30 s. The fracture strength of specimens was then assessed using a universal testing machine at a crosshead speed of 1.0 mm/min. One-way ANOVA and Bonferroni correction multiple comparisons were used to assess the fracture strength differences between the test groups (α = 0.001). Descriptive fractographic analysis of specimens was carried out with scanning electron microscopy images. RESULTS: Complete coverage crown and LV with palatal chamfer design had the highest fracture resistance values (781.4 ± 151.4 and 618.2 ± 112.6 N, respectively). Single crown and LV with palatal chamfer had no significant difference in fracture strength (p > 05). LV with feathered-edge and butt-joint designs provided significantly (p < 05) lower fracture resistance than complete coverage crown and LV with palatal chamfer design. CONCLUSION: The fracture resistance of chairside milled ZLS veneers was significantly influenced by the incisal preparation designs tested. Within the limitation of this study, when excessive occlusal forces are expected, LV with palatal chamfer display is the most conservative method of fabricating an indirect restoration.


Assuntos
Cerâmica , Porcelana Dentária , Porcelana Dentária/uso terapêutico , Resistência à Flexão , Lítio , Teste de Materiais , Análise do Estresse Dentário , Coroas , Zircônio/uso terapêutico , Silicatos , Desenho Assistido por Computador , Planejamento de Prótese Dentária
2.
J Prosthodont ; 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38305664

RESUMO

PURPOSE: This study aimed to develop and evaluate a simple, non-destructive method for assessing the misfit and passivity of implant-retained prostheses frameworks. MATERIALS AND METHODS: To simulate the rehabilitation of a mandible posterior partially edentulous area using 3-unit screw-retained frameworks supported by two implants were fabricated and divided into the following five groups (n = 10 in each group): OP = one-piece framework cast in Co-Cr with the conventional method (control-group); Co-Cr frameworks sectioned and welded by laser (=LAS) or tungsten inert gas (=TIG); Co-Cr CAD-CAM = milled Co-Cr framework; Zir CAD-CAM = milled zirconia framework. The horizontal |X| and vertical |Y| misfits were measured using confocal laser scanning microscopy with one or both screws tightened. Data were analyzed by a two-way ANOVA with repeated measures and Bonferroni correction (α = 0.05). RESULTS: The greatest |X| misfit was observed in the OP group with both screws tightened (290 µm) and one screw tightened (388 and 340 µm). The conventional casting groups sectioned and welded by laser or TIG had lower mean values (235.35 µm, both screws tightened; and 275 µm, one screw tightened) than the OP framework. However, these values still exceeded those of the milled Co-Cr and zirconia frameworks (190 and 216 µm with both screws tightened). Across all reading conditions, every framework subjected to testing consistently maintained vertical |Y| misfit levels below the threshold of 53 µm; however, the milled frameworks exhibited higher vertical misfits than the frameworks obtained by the conventional cast method. CONCLUSIONS: The frameworks, whether cast and sectioned with laser welding or milled from Co-Cr, exhibit improved marginal misfit and enhanced passive fit when compared to other fabrication methods. Additionally, the use of confocal laser scanning microscopy is highly effective for passivity and misfit analysis.

3.
J Prosthodont ; 32(8): 728-734, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36471494

RESUMO

PURPOSE: To evaluate the effect of traditional and conservative endodontic access hole preparation on fracture resistance of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate maxillary right central incisor crowns. MATERIALS AND METHODS: Fifty-seven milled lithium disilicate maxillary right central incisor crowns were designed and fabricated with a chairside CAD-CAM system (Planmeca Romexis, Planmeca). The abutment preparation had a 1.0 mm incisal reduction and 1.0 mm chamfer finish. The restorations were bonded with resin cement to printed resin dies (n = 19 per group) and were treated and divided into three groups, (1) no endodontic access, (2) traditional triangular endodontic access, and (3) conservative ovoidal endodontic access. The endodontic access of the crowns was sealed with flowable resin composite. Restorations were subjected to 10,000 cycles of thermal cycling between 5° and 55°C. Then, restorations were loaded and exposed to compressive loading force, and the crack initiation (CI) and complete fracture (CF) were recorded. SEM micrographs of broken specimens on the printed dies were captured. ANOVA test and Bonferroni's correction were used for statistical comparison. RESULTS: The fracture resistance among the three groups varied. Crowns with no endodontic access displayed significantly (p < 0.001) higher resistance [CI: 1025 (121) N; CF 1134 (127) N], followed by crowns with conservative ovoidal endodontic access [CI: 924 (60) N; CF: 1000 (72) N. Crowns with traditional triangular endodontic access showed the significantly (p < 0.001) lowest fracture resistance [CI: 635 (82) N; CF: 709 (75) N]. CONCLUSION: The fracture resistance of chairside CAD-CAM lithium disilicate maxillary anterior crowns is influenced by the type of endodontic access provided. Conservative ovoidal endodontic access provides crowns with higher fracture resistance than traditional triangular endodontic access. Crowns with no endodontic access provided the highest resistance than other types of endodontic access.


Assuntos
Cerâmica , Falha de Restauração Dentária , Teste de Materiais , Análise do Estresse Dentário , Porcelana Dentária , Coroas , Desenho Assistido por Computador , Planejamento de Prótese Dentária
4.
Medicina (Kaunas) ; 59(6)2023 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-37374252

RESUMO

Background and Objective: This study aimed to compare the surface finish of milled leucite-reinforced ceramics polished with ceramic and composite polishing systems based on the manufacturers' recommendations. Materials and Methods: Sixty subtractive computer-aided manufactured (s-CAM) leucite-reinforced glass-ceramic specimens (IPS-Empress-CAD) were assigned into six groups: no polishing, a ceramic polishing kit, and four composite kit groups. The roughness average (Ra) was evaluated in microns using a profilometer, and scanning electron micrographs were obtained for qualitative analysis. A Tukey HSD posthoc test (α = 0.05) was used to determine significant intergroup differences. Results: After surface evaluation of the ceramics, the Ra values of the polishing systems ranked OptraFine (0.41 ± 0.26) < Enhance (1.60 ± 0.54) < Shofu (2.14 ± 0.44) < Astropol (4.05 ± 0.72) < DiaComp (5.66 ± 0.62) < No Polishing (5.66 ± 0.74). Discussion: Composite polishing systems did not provide as smooth surfaces as the ceramic polishing kit for CAD-CAM leucite-reinforced ceramics. Thus, using ceramic polishing systems, polishing leucite ceramics is recommended, whereas composite polishing systems should not be considered as an alternative for use in minimally invasive dentistry.


Assuntos
Cerâmica , Resinas Compostas , Humanos , Teste de Materiais , Propriedades de Superfície
5.
J Virol ; 95(16): e0084121, 2021 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-34076479

RESUMO

Lung-localized CD4 T cells play a critical role in the control of influenza virus infection and can provide broadly protective immunity. However, current influenza vaccination strategies primarily target influenza hemagglutinin (HA) and are administered peripherally to induce neutralizing antibodies. We have used an intranasal vaccination strategy targeting the highly conserved influenza nucleoprotein (NP) to elicit broadly protective lung-localized CD4 T cell responses. The vaccine platform consists of a self-assembling nanolipoprotein particle (NLP) linked to NP with an adjuvant. We have evaluated the functionality, in vivo localization, and persistence of the T cells elicited. Our study revealed that intranasal vaccination elicits a polyfunctional subset of lung-localized CD4 T cells that persist long term. A subset of these lung CD4 T cells localize to the airway, where they can act as early responders following encounter with cognate antigen. Polyfunctional CD4 T cells isolated from airway and lung tissue produce significantly more effector cytokines IFN-γ and TNF-α, as well as cytotoxic functionality. When adoptively transferred to naive recipients, CD4 T cells from NLP:NP-immunized lung were sufficient to mediate 100% survival from lethal challenge with H1N1 influenza virus. IMPORTANCE Exploiting new, more efficacious strategies to potentiate influenza virus-specific immune responses is important, particularly for at-risk populations. We have demonstrated the promise of direct intranasal protein vaccination to establish long-lived immunity in the lung with CD4 T cells that possess features and positioning in the lung that are associated with both immediate and long-term immunity, as well as demonstrating direct protective potential.


Assuntos
Antígenos Virais/imunologia , Linfócitos T CD4-Positivos/imunologia , Vacinas contra Influenza/imunologia , Pulmão/imunologia , Infecções por Orthomyxoviridae/prevenção & controle , Vacinação/métodos , Adjuvantes Imunológicos/administração & dosagem , Adjuvantes Imunológicos/química , Administração Intranasal , Transferência Adotiva , Animais , Antígenos Virais/administração & dosagem , Antígenos Virais/química , Linfócitos T CD4-Positivos/transplante , Imunidade nas Mucosas , Imunização Secundária , Memória Imunológica , Vírus da Influenza A Subtipo H1N1/imunologia , Vacinas contra Influenza/administração & dosagem , Vacinas contra Influenza/química , Lipoproteínas/administração & dosagem , Lipoproteínas/química , Lipoproteínas/imunologia , Pulmão/irrigação sanguínea , Camundongos , Nanopartículas/administração & dosagem , Nanopartículas/química , Proteínas do Nucleocapsídeo/química , Proteínas do Nucleocapsídeo/imunologia , Infecções por Orthomyxoviridae/imunologia , Subpopulações de Linfócitos T/imunologia , Subpopulações de Linfócitos T/transplante
6.
PLoS Comput Biol ; 16(5): e1007834, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32453727

RESUMO

Neurons form complex networks that evolve over multiple time scales. In order to thoroughly characterize these networks, time dependencies must be explicitly modeled. Here, we present a statistical model that captures both the underlying structural and temporal dynamics of neuronal networks. Our model combines the class of Stochastic Block Models for community formation with Gaussian processes to model changes in the community structure as a smooth function of time. We validate our model on synthetic data and demonstrate its utility on three different studies using in vitro cultures of dissociated neurons.


Assuntos
Potenciais de Ação , Modelos Neurológicos , Rede Nervosa/fisiologia , Neurônios/fisiologia , Animais , Células Cultivadas , Córtex Cerebral/citologia , Eletrodos , Hipocampo/citologia , Cadeias de Markov , Camundongos , Neuroglia/citologia , Distribuição Normal , Probabilidade , Ratos , Processos Estocásticos , Fatores de Tempo
7.
J Immunol ; 202(2): 591-597, 2019 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-30541879

RESUMO

MHC proteins that present peptide ligands for recognition by TCR form nanoscale clusters on the cell membrane of APCs. How the extent of MHC clustering controls productive TCR engagement and TCR-mediated signaling has not been systematically studied. To evaluate the role of MHC clustering, we exploited nanoscale discoidal membrane mimetics (nanolipoprotein particles) to capture and present peptide-MHC (pMHC) ligands at various densities. We examined the binding of these model membrane clusters to the surface of live human CD8+ T cells and the subsequent triggering of intracellular signaling. The data demonstrate that the proximity of pMHC ligands, high association rate of CD8-MHC interactions, and relatively long lifetime of cognate TCR-pMHC complexes emerge as essential parameters, explaining the significance of MHC clustering. Rapid rebinding of CD8 to MHC suggests a dual role of CD8 in facilitating the T cells' hunt for a rare foreign pMHC ligand and the induction of rapid T cell response. Thus, our findings provide a new understanding of how MHC clustering influences multivalent interactions of pMHC ligands with CD8 and TCR on live T cells that regulate Ag recognition, kinetics of intracellular signaling, and the selectivity and efficiency of T cell responses.


Assuntos
Linfócitos T CD8-Positivos/imunologia , Antígenos de Histocompatibilidade Classe I/imunologia , Receptores de Antígenos de Linfócitos T/imunologia , Transdução de Sinais , Sítios de Ligação , Biomimética , Humanos , Cinética , Ativação Linfocitária , Peptídeos/química , Ligação Proteica
8.
Am J Dent ; 34(4): 201-204, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34370912

RESUMO

PURPOSE: To evaluate the influence of light irradiation on the clinical efficiency of an in-office whitening agent. METHODS: The in-office whitening agent (Opalescence Boost 35%) was used in this study. Two whitening regimens were evaluated on maxillary anterior teeth: (1) with light irradiation; and (2) without light irradiation. The ΔE*, changes of L*, a*, b*, and the best shade match on the central incisor before, immediately after, and 6 months after whitening procedures were evaluated using a dental spectrophotometer. RESULTS: The ΔE and shade had no significant differences with or without light irradiation. In addition, the ΔE, changes of L*, a*, b*, and shade did not change over 6 months after bleaching at a level detectable to the naked eye. The results suggested that the in-office whitening agent using 35% hydrogen peroxide without photocatalysts can improve tooth color with or without light irradiation for 6 months after whitening. CLINICAL SIGNIFICANCE: In office whitening using 35% hydrogen peroxide without photocatalysts should be considered as a good treatment option for vital teeth whitening.


Assuntos
Clareadores Dentários , Clareamento Dental , Dente , Cor , Humanos , Peróxido de Hidrogênio , Clareadores Dentários/uso terapêutico
9.
Biomacromolecules ; 21(12): 4945-4961, 2020 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-32961056

RESUMO

Bioadhesive membranes with controllable and reversible underwater adhesion are desirable for several biomedical applications ranging from biosensing, drug/therapeutic delivery, and tissue regeneration. Here, we present dual soft mucosal and hard bone/enamel tissue adhesive nanofiber membranes composed of chitosan and pectin derivatives for pH-controlled delivery of antimicrobial peptides (AMPs) in the oral cavity. Ex vivo testing with porcine esophagus (soft mucosal mimic) indicated a 2-fold increase in the mucoadhesion of chitosan membranes with 0.05 wt % oxidized pectin coating, while the uncoated membranes exhibited 3-4-fold stronger adhesion to hydroxyapatite discs (enamel/hard bone mimic) compared to the coated membranes. The former is attributed to a synergistic interaction of surface nanofiber topography, intermolecular hydrogen bonding, and aldehyde-amine chemistry between surface polar groups and mucosal proteins, while the latter may arise from electrostatic interactions between cationic amines (-NH3+) in chitosan and anionic phosphates (-PO43-) in hydroxyapatite. Further, the dual hard-soft oral tissue adhesive nanofiber membranes loaded with cationic amphipathic AMPs (D-GL13K and IDR-1018) elicited pH-responsive AMP delivery and antimicrobial action comparable to chlorhexidine (CHX) against oral streptococci. Concurrently, the AMP loaded membranes were cytocompatible to both soft epithelial tissue-derived human oral keratinocytes and hard calvarial murine pre-osteoblast cells. We envision these membranes to function as adhesive gingival grafts and guided bone regeneration (GBR) membranes at the hard-soft tissue interface while simultaneously protecting against oral infections.


Assuntos
Antibacterianos , Nanofibras , Adesivos Teciduais , Adesivos , Animais , Antibacterianos/administração & dosagem , Sistemas de Liberação de Medicamentos , Humanos , Concentração de Íons de Hidrogênio , Camundongos , Peptídeos/administração & dosagem , Proteínas Citotóxicas Formadoras de Poros , Suínos
10.
Eur J Oral Sci ; 128(4): 354-360, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32395905

RESUMO

In order to evaluate the influence of 38% silver diamine fluoride (SDF) application on enamel and dentin bond stability of universal adhesives in self-etch mode, a 38% SDF and three universal adhesives were used in this study. Initial shear bond strength (ISBS), fatigue bond strength (FBS), and shear bond strength of survivors (SBSS) to enamel and dentin of universal adhesives in self-etch mode, with and without SDF application, were determined. SDF was applied to the polished enamel or dentin surface for 1 min, water-rinsed and air-dried for comparison with controls. The universal adhesives were applied to the prepared samples and composite resin was bonded using a mold-enclosed method. Enamel bond stability of universal adhesives with SDF (ISBS: 14.7-20.4 MPa; FBS: 5.5-7.4 MPa and SBSS: 14.4-21.5 MPa) was significantly weaker than those without SDF (ISBS: 28.0-29.2 MPa; FBS: 12.1-15.6 MPa and SBSS: 28.4-34.4 MPa). Dentin bond stability with SDF (ISBS: 14.8-20.9 MPa; FBS: 7.1-8.2 MPa and SBSS: 17.3-21.8 MPa) was also significantly weaker than without SDF (ISBS: 19.3-36.1 MPa; FBS: 11.0-13.7 MPa and SBSS: 22.2-34.6 MPa). The results suggest that SDF application on enamel and dentin reduces the bond stability of universal adhesives in self-etch mode.


Assuntos
Colagem Dentária , Adesivos Dentinários , Cimentos Dentários , Esmalte Dentário , Dentina , Fluoretos Tópicos , Teste de Materiais , Compostos de Amônio Quaternário , Cimentos de Resina , Resistência ao Cisalhamento , Compostos de Prata
11.
Nanomedicine ; 24: 102154, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31982617

RESUMO

In vivo delivery of large RNA molecules has significant implications for novel gene therapy, biologics delivery, and vaccine applications. We have developed cationic nanolipoprotein particles (NLPs) to enhance the complexation and delivery of large self-amplifying mRNAs (replicons) in vivo. NLPs are high-density lipoprotein (HDL) mimetics, comprised of a discoidal lipid bilayer stabilized by apolipoproteins that are readily functionalized to provide a versatile delivery platform. Herein, we systematically screened NLP assembly with a wide range of lipidic and apolipoprotein constituents, using biophysical metrics to identify lead candidates for in vivo RNA delivery. NLPs formulated with cationic lipids successfully complexed with RNA replicons encoding luciferase, provided measurable protection from RNase degradation, and promoted replicon in vivo expression. The NLP complexation of the replicon and in vivo transfection efficiency were further enhanced by modulating the type and percentage of cationic lipid, the ratio of cationic NLP to replicon, and by incorporating additive molecules.


Assuntos
Lipoproteínas HDL/metabolismo , RNA Mensageiro/metabolismo , Apolipoproteínas/química , Apolipoproteínas/metabolismo , Biomimética , Bicamadas Lipídicas/química , Lipoproteínas HDL/química , RNA Mensageiro/química , Replicon/genética
12.
Am J Dent ; 33(6): 320-324, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33439562

RESUMO

PURPOSE: To evaluate the ability of a pencil-type transducer connected to a pulser-receiver to measure remaining dentin thickness (RDT). METHODS: A total of 24 freshly extracted bovine incisors were used to prepare dentin disks with certain thicknesses (0.5, 1.0, 1.5 and 2.0 mm). The thicknesses of the specimens were measured with an ultrasonic technique using a pencil-type transducer, and the data obtained were compared with the direct measurement obtained using a micrometer. The Bland-Altman comparison method and paired t-test were performed at a 0.05 significance level. RESULTS: The agreement between different measurement methods was analyzed to evaluate the inter-methodology variation. The Bland-Altman comparison method revealed a mean difference of 0.0098 ± 0.724 mm between the ultrasonic technique and the direct measurement, with the 95% Bland-Altman limits of agreement ranging from 0.1322 to 0.1517 mm. CLINICAL SIGNIFICANCE: Ultrasonic measurement using the pencil-type transducer may be a promising method to evaluate remaining dentin thickness.


Assuntos
Dentina , Ultrassom , Animais , Bovinos , Dentina/diagnóstico por imagem , Incisivo/diagnóstico por imagem , Transdutores
13.
Gen Dent ; 68(1): 46-49, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31859662

RESUMO

Esthetic problems in maxillary central incisors are often difficult to treat with dental implants. It is necessary to preserve the interdental papillae, or regenerate them if they are absent, and minimize the risk of loss of hard or soft tissue. This task may be made easier by the recent introduction of ultratranslucent zirconia, which can be used with custom zirconia abutments to mutually enhance the effectiveness of both materials. This case report describes implant therapy with ultratranslucent monolithic zirconia restorations in the esthetic zone. In this approach, adequate pink esthetics can be achieved by delayed titanium implant placement in conjunction with guided bone regeneration. Ultratranslucent monolithic zirconia restorations with custom zirconia abutments provide predictable esthetic results.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Estética Dentária , Zircônio , Coroas , Dente Suporte , Humanos
14.
J Contemp Dent Pract ; 21(11): 1293-1297, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33850078

RESUMO

AIM AND OBJECTIVE: This case report shows how a feldspathic veneer with diagnostic wax-ups, subsequent mock-up, and reduction guides can lead to good patient esthetics and reports a 5-year follow-up. BACKGROUND: Conservative tooth preparation is important for the long-term success of adhesive dentistry as it has been shown that bonding to enamel is more predictable in obtaining better long-term success than dentin. To preserve enamel for optimal bonding, diagnostic wax-ups and the subsequent mock-up are the first tools in a restorative dentist's arsenal to find and address differences between current and ideal tooth proportions and also help toward an overall conservative approach. Reduction guides are recommended in order to provide adequate tooth reduction and prevent over-reduction. CASE DESCRIPTION: This case report shows a 5-year follow-up of feldspathic veneer restorations for a patient with excessive space among teeth, defective composite restorations on facial and incisal surfaces, and worn teeth. Veneers were delivered with conservative tooth preparation combining different tooth reduction guides. CONCLUSION: This case report highlights the added benefits of tooth reduction guides and diagnostic wax-ups and the subsequent mock-up for long-term patient satisfaction. CLINICAL SIGNIFICANCE: Conservative tooth preparation, reduction guides, and wax-ups may increase the life span of veneer restorations and demonstrate good esthetics at 5 years.


Assuntos
Porcelana Dentária , Facetas Dentárias , Estética Dentária , Seguimentos , Humanos , Preparo do Dente
15.
Clin Anat ; 32(6): 778-782, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31056789

RESUMO

The aortic valve (AV) has been used as a surrogate marker for the superior vena cava-right atrium (SVC-RA) junction during the placement of central venous catheters. There is a paucity of evidence to determine whether this is a consistent finding in children. Eighty-seven computed tomography scans of the thorax acquired at local children's hospitals from April 2010 to September 2011 were retrospectively collected. The distance between the SVC-RA junction and the AV was measured by dual consensus. The cranio-caudal level of the junction and the AV were referenced to the costal cartilages (CCs) and anterior intercostal spaces (ICSs). The results confirmed that the SVC-RA junction has a variable relationship to the AV. The junction was on average 3.1 mm superior to the AV. This distance increased with age. In the <1-year-old age group, the junction was on average 1.3 mm superior to the AV (range: -6 to 11 mm). In the 1-2 years old age group: 3.5 mm (range: -8 to 15 mm). In the 3-6 years old: 3.8 mm (range: -9 to 13 mm). In the >7 years old age group: 4 mm (range: -11 to 16 mm). The surface anatomy of the SVC-RA junction was variable, ranging from the second ICS to sixth CC. The SVC-RA junction has a predictable relationship to the AV, and this can be used as an adjunct marker for accurate placement of central venous catheters except in the smallest neonates. Clin. Anat. 32:778-782, 2019. © 2019 Wiley Periodicals, Inc.


Assuntos
Pontos de Referência Anatômicos/anatomia & histologia , Valva Aórtica/anatomia & histologia , Átrios do Coração/anatomia & histologia , Veia Cava Superior/anatomia & histologia , Valva Aórtica/diagnóstico por imagem , Cateterismo Venoso Central/métodos , Criança , Pré-Escolar , Estudos Transversais , Átrios do Coração/diagnóstico por imagem , Humanos , Lactente , Recém-Nascido , Músculos Intercostais , Estudos Retrospectivos , Cavidade Torácica/anatomia & histologia , Cavidade Torácica/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Veia Cava Superior/diagnóstico por imagem
16.
Am J Dent ; 32(1): 33-38, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30834729

RESUMO

PURPOSE: To evaluate whether surface moisture would influence the bonding effectiveness of universal adhesives in etch-and-rinse mode. METHODS: All-Bond Universal (AB), G-Premio Bond (GP) Prime&Bond Active (PB) and Scotchbond Universal Adhesive (SU) were evaluated. Shear bond strengths after 24 hours and 10,000 thermal cycles of universal adhesives to moist and dry enamel and dentin in etch-and-rinse mode were determined. Scanning electron microscopy observations of the adhesive interfaces were conducted. RESULTS: The bond durability of universal adhesive to dentin in etch-and-rinse mode was influenced by the surface moisture, unlike bond durability to enamel. The bond durability of AB and GP, but not PB and SU, to dentin in etch-and-rinse mode was different depending on the surface moisture. Surface moisture did not influence the thicknesses of the adhesive or hybrid layer of resin-dentin interfaces, but the length of resin tags in the moist group was longer than in the dry group. CLINICAL SIGNIFICANCE: Some universal adhesives, with the addition of specific components and optimization of water content, can achieve stable bonds regardless of surface moisture, but the surface moisture of dentin, although not enamel, is still a significant factor for universal adhesive bonding in etch-and rinse mode.


Assuntos
Colagem Dentária , Adesivos Dentinários , Dentina , Condicionamento Ácido do Dente , Cimentos Dentários , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície
17.
J Biol Chem ; 292(36): 15121-15132, 2017 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-28739800

RESUMO

Chlamydia is a prevalent sexually transmitted disease that infects more than 100 million people worldwide. Although most individuals infected with Chlamydia trachomatis are initially asymptomatic, symptoms can arise if left undiagnosed. Long-term infection can result in debilitating conditions such as pelvic inflammatory disease, infertility, and blindness. Chlamydia infection, therefore, constitutes a significant public health threat, underscoring the need for a Chlamydia-specific vaccine. Chlamydia strains express a major outer-membrane protein (MOMP) that has been shown to be an effective vaccine antigen. However, approaches to produce a functional recombinant MOMP protein for vaccine development are limited by poor solubility, low yield, and protein misfolding. Here, we used an Escherichia coli-based cell-free system to express a MOMP protein from the mouse-specific species Chlamydia muridarum (MoPn-MOMP or mMOMP). The codon-optimized mMOMP gene was co-translated with Δ49apolipoprotein A1 (Δ49ApoA1), a truncated version of mouse ApoA1 in which the N-terminal 49 amino acids were removed. This co-translation process produced mMOMP supported within a telodendrimer nanolipoprotein particle (mMOMP-tNLP). The cell-free expressed mMOMP-tNLPs contain mMOMP multimers similar to the native MOMP protein. This cell-free process produced on average 1.5 mg of purified, water-soluble mMOMP-tNLP complex in a 1-ml cell-free reaction. The mMOMP-tNLP particle also accommodated the co-localization of CpG oligodeoxynucleotide 1826, a single-stranded synthetic DNA adjuvant, eliciting an enhanced humoral immune response in vaccinated mice. Using our mMOMP-tNLP formulation, we demonstrate a unique approach to solubilizing and administering membrane-bound proteins for future vaccine development. This method can be applied to other previously difficult-to-obtain antigens while maintaining full functionality and immunogenicity.


Assuntos
Proteínas da Membrana Bacteriana Externa/química , Proteínas da Membrana Bacteriana Externa/imunologia , Vacinas Bacterianas/química , Vacinas Bacterianas/imunologia , Infecções por Chlamydia/imunologia , Chlamydia muridarum/imunologia , Animais , Proteínas da Membrana Bacteriana Externa/genética , Sequência de Bases , Sistema Livre de Células , Infecções por Chlamydia/microbiologia , Feminino , Camundongos , Camundongos Endogâmicos BALB C
18.
Int J Cancer ; 143(8): 1963-1977, 2018 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-29756328

RESUMO

Elevated levels of the carcinoembryonic antigen (CEA; CEACAM5) in the serum of colorectal cancer (CRC) patients represent a clinical biomarker that correlates with disease recurrence. However, a mechanistic role for soluble CEA (sCEA) in tumor progression and metastasis remains to be established. In our study, we report that sCEA acts as a paracrine factor, activating human fibroblasts by signaling through both the STAT3 and AKT1-mTORC1 pathways, promoting their transition to a cancer-associated fibroblast (CaF) phenotype. sCEA-activated fibroblasts express and secrete higher levels of fibronectin, including cellular EDA+ -fibronectin (Fn-EDA) that selectively promote the implantation and adherence of CEA-expressing cancer cells. Immunohistochemical analyses of liver tissues derived from CRC patients with elevated levels of sCEA reveal that the expression of cellular Fn-EDA co-registers with CEA-expressing liver metastases. Taken together, these findings indicate a direct role for sCEA as a human fibroblast activation factor, in priming target tissues for the engraftment of CEA-expressing cancer cells, through the differentiation of tissue-resident fibroblasts, resulting in a local change in composition of the extracellular matrix.


Assuntos
Antígeno Carcinoembrionário/sangue , Antígeno Carcinoembrionário/metabolismo , Matriz Extracelular/metabolismo , Fibroblastos/patologia , Diferenciação Celular/fisiologia , Linhagem Celular , Linhagem Celular Tumoral , Neoplasias Colorretais/sangue , Neoplasias Colorretais/metabolismo , Neoplasias Colorretais/patologia , Matriz Extracelular/fisiologia , Fibroblastos/metabolismo , Fibronectinas/metabolismo , Células HT29 , Humanos , Neoplasias Hepáticas/sangue , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/patologia , Alvo Mecanístico do Complexo 1 de Rapamicina/metabolismo , Recidiva Local de Neoplasia/sangue , Recidiva Local de Neoplasia/metabolismo , Recidiva Local de Neoplasia/patologia , Proteínas Proto-Oncogênicas c-akt/metabolismo , Fator de Transcrição STAT3/metabolismo , Transdução de Sinais/fisiologia
19.
Eur J Oral Sci ; 126(4): 316-325, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29978921

RESUMO

The purpose of this study was to examine the shear fatigue strengths of a resin composite bonded to dentin. Three adhesive systems - a two-step self-etch adhesive (OptiBond XTR; Kerr) and two universal adhesives [Scotchbond Universal (3M ESPE) and G-Premio Bond (GC)] - were used in self-etch mode to bond a resin composite to dentin at a physiologic frequency of 2 Hz over 50,000, 100,000, and 1,000,000 cycles. A staircase method of fatigue testing was used. Twenty specimens were used for each test condition. There was no significant difference in shear fatigue strength across the cycling periods for the three individual adhesives. Differences in shear fatigue strength were found among the three adhesives within each cycling period. Regardless of the adhesive used in self-etch mode for bonding a resin composite to dentin, shear fatigue strength was not influenced by the number of cycles used for testing.


Assuntos
Resinas Compostas/química , Colagem Dentária/métodos , Dentina/química , Cimentos de Resina/química , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Teste de Materiais , Metacrilatos , Dente Molar , Resistência ao Cisalhamento , Dióxido de Silício , Propriedades de Superfície , Zircônio
20.
J Adhes Dent ; 19(3): 267-275, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28597008

RESUMO

PURPOSE: To examine the effect of reduced phosphoric acid pre-etching times on enamel fatigue bond strength of universal adhesives and surface characteristics by using atomic force microscopy (AFM). MATERIALS AND METHODS: Three universal adhesives were used in this study (Clearfil Universal Bond [C], G-Premio Bond [GP], Scotchbond Universal Adhesive [SU]). Four pre-etching groups were employed: enamel pre-etched with phosphoric acid and immediately rinsed with an air-water spray, and enamel pre-etched with phosphoric acid for 5, 10, or 15 s. Ground enamel was used as the control group. For the initial bond strength test, 15 specimens per etching group for each adhesive were used. For the shear fatigue test, 20 specimens per etching group for each adhesive were loaded using a sine wave at a frequency of 20 Hz for 50,000 cycles or until failure occurred. Initial shear bond strengths and fatigue shear strengths of composite adhesively bonded to ground and pre-etched enamel were determined. AFM observations of ground and pre-etched enamel were also conducted, and surface roughness as well as surface area were evaluated. RESULTS: The initial shear bond strengths and fatigue shear strengths of the universal adhesives in the pre-etched groups were significantly higher than those of the control group, and were not influenced by the pre-etching time. Significantly higher surface roughness and surface area of enamel surfaces in pre-etched groups were observed compared with those in the control group. While the surface area was not significantly influenced by etching time, surface roughness of the enamel surfaces in the pre-etched groups significantly increased with pre-etching time. CONCLUSIONS: The results of this in vitro study suggest that reduced phosphoric acid pre-etching times do not impair the fatigue bond strength of universal adhesives. Although fatigue bond strength and surface area were not influenced by phosphoric-acid etching times, surface roughness increased with increasing etching time.


Assuntos
Condicionamento Ácido do Dente , Colagem Dentária , Cimentos Dentários , Esmalte Dentário , Teste de Materiais , Microscopia Eletrônica de Varredura , Ácidos Fosfóricos , Cimentos de Resina , Resistência ao Cisalhamento , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA