Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
1.
Echocardiography ; 41(1): e15698, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38284664

RESUMO

BACKGROUND: Transaortic valve implant (TAVI) is the treatment of choice for severe aortic stenosis (AS). Some patients develop prosthesis patient mismatch (PPM) after TAVI. It is challenging to determine which patients are at risk for clinical deterioration. METHODS: We retrospectively measured echocardiographic parameters of left ventricular (LV) morphology and function, prosthetic aortic valve effective orifice area (iEOA) and hemodynamics in 313 patients before and 1 year after TAVI. Our objective was to compare the change in echocardiographic parameters associated with left ventricular reverse modeling in subjects with and without PPM. Our secondary objective was to evaluate echo parameters associated with PPM and the relationship to patient functional status and survival post-TAVI. RESULTS: We found that 82 (26.2%) of subjects had moderate and 37 (11.8%) had severe PPM post-TAVI. There was less relative improvement in LVEF with PPM (1.9 ± 21.3% vs. 8.2 + 30.1%, p = .045). LV GLS also exhibited less relative improvement in those with PPM (13.4 + 34.1% vs. 30.9 + 73.3%, p = .012). NYHA functional class improved in 84.3% of subjects by one grade or more. Echocardiographic markers of PPM were worse in those without improvement in NYHA class (mean AT/ET was .29 vs. .27, p = .05; DVI was .46 vs. .51, p = .021; and iEOA was .8 cm/m2 vs. .9 cm/m2 , p = .025). There was no association with PPM and survival. CONCLUSIONS: There was no improvement in LVEF and less improvement in LV GLS in those with PPM post-TAVI. Echocardiographic markers of PPM were present in those with lack of improvement in NYHA functional class.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Retrospectivos , Remodelação Ventricular , Resultado do Tratamento , Ecocardiografia
2.
Anesthesiology ; 136(4): 531-541, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35061005

RESUMO

BACKGROUND: Interscalene blocks provide analgesia for shoulder surgery but also cause phrenic nerve paralysis. Liposomal bupivacaine is approved for use in interscalene blocks with the potential to provide longer pain control. However, the impact of liposomal bupivacaine on the phrenic nerve has not been evaluated. It was hypothesized that patients who received an interscalene block with both bupivacaine and liposomal bupivacaine would have a decreased diaphragmatic excursion when compared to bupivacaine alone at 24 h. METHODS: This was a double-blinded study of adult patients who were randomized to receive an interscalene block with either 20 ml 0.5% bupivacaine (bupivacaine group) or 10 ml 0.5% bupivacaine plus 10 ml liposomal bupivacaine (liposomal bupivacaine group). Twenty-six patients were randomized with 22 included in the analysis. Diaphragmatic excursion (via ultrasound) and spirometry were assessed before the block, in the postanesthesia care unit, and at 24 h postblock. The primary outcome was diaphragm excursion with sigh. No adverse events were observed. RESULTS: At 24 h, the liposomal bupivacaine group median [25th, 75th], had a greater percent change in diaphragmatic excursion during sigh breath compared to the bupivacaine group, -24% [-30, -9] versus 9% [-8, 26], difference in location, 32 (95% CI, 12 to 52), P = 0.007. Five patients in the liposomal bupivacaine group had a greater than 25% reduction in diaphragmatic excursion at 24 h versus zero in the bupivacaine group. They also had a significantly greater percent reduction in forced expiratory volume in 1 s and forced vital capacity compared with the bupivacaine group at 24 h (median decrease of 22% vs. 2%, P = 0.006, and median decrease of 19% vs. 1%, P = 0.049, respectively). CONCLUSIONS: The addition of liposomal bupivacaine to bupivacaine in an interscalene block results in statistically significant reductions in diaphragm excursion and pulmonary function testing 24 h after block placement when compared to bupivacaine alone. This reduction, however, falls within the range of normal diaphragmatic function.


Assuntos
Anestésicos Locais , Bloqueio do Plexo Braquial , Adulto , Bloqueio do Plexo Braquial/métodos , Bupivacaína , Diafragma/diagnóstico por imagem , Humanos , Dor Pós-Operatória
3.
J Card Surg ; 36(1): 89-96, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33170533

RESUMO

OBJECTIVE: Surgical reoperation for aortic homograft structural valve degeneration (SVD) is a high-risk procedure. Transcatheter aortic valve replacement (TAVR) for homograft-SVD is an alternative to reoperation, but descriptions of implantation techniques are limited. This study compares outcome in patients undergoing into two groups by the type of previously implanted aortic valve prosthesis: TAVR for failed aortic homografts (TAVR-H) or for stented aortic bioprostheses (TAVR-BP). METHODS: From 2015 to 2017, TAVR was performed in 41 patients with SVD. Thirty-three patients in the TAVR-BP group (six for SVD of valved conduits), and eight patients in the TAVR-H group. The Valve Academic Research Consortium criteria were used for outcome reporting purposes. RESULTS: The patients with TAVR-BP had predominant prosthetic stenosis (94%, p = .002), whereas TAVR-H individuals presented mostly with regurgitation (88%, p = <.001). Patients with TAVR-H received: Sapien-3 (6), Sapien-XT (1), and CoreValve (1) devices. Low, 40% ventricular fixation in relation to homograft annulus was attempted to anchor the prosthesis on the homograft suture-line. One patient with TAVR-BP experienced intraoperative distal prosthesis migration and Type-B aortic dissection, and two patients in the TAVR-H group had late postoperative proximal device migration. In both groups, there was zero 30-day mortality, stroke, or pacemaker implantation. CONCLUSIONS: TAVR for failing aortic homografts may be a feasible and safe alternative to high-risk surgical reintervention. Precise, 40%-ventricular device positioning appears crucial for prevention of late paravalvular leak/late prosthesis migration and minimizing the risk of repeat surgical intervention.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Aloenxertos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
4.
Pain Med ; 21(2): e201-e207, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31670776

RESUMO

OBJECTIVE: Patients undergoing open inguinal hernia repair may experience moderate to severe postoperative pain. We assessed opioid consumption in subjects who received a continuous transversus abdominis plane block in addition to standard multimodal analgesia. DESIGN: Randomized, double-blind, placebo-controlled. SETTING: Tertiary academic medical center. SUBJECTS: Adult patients undergoing open inguinal hernia repair at Virginia Mason Medical Center. A total of 90 patients were enrolled. METHODS: Subjects presenting for surgery were randomized to receive either a continuous transversus abdominis plane block or a subcutaneous sham block. The primary outcome was opioid consumption within the first 48 hours after surgery. Secondary outcomes included pain scores, activities assessment scores, and opioid-related adverse events. Multimodal analgesia utilized in both groups included acetaminophen, nonsteroidal anti-inflammatory drugs, and surgical local anesthetic infiltration. RESULTS: Eighty-two subjects, 42 from the block group and 40 from the sham group, completed the study, per protocol. The intention-to-treat analysis demonstrated no difference in 48-hour postoperative oxycodone equivalent consumption between the block and sham groups (27.8 mg ± 26.8 vs 32 mg ± 39.2, difference -4.4 mg, P = 0.55). There was a statistically significant reduction in pain scores at 24 hours in the block group. There were no other differences in secondary outcomes. CONCLUSIONS: Continuous transversus abdominis plane blocks provide modest improvements in pain after open inguinal hernia repair but fail to significantly reduce opioid consumption or improve functional activity levels in the setting of multimodal analgesia use.


Assuntos
Hérnia Inguinal/cirurgia , Bloqueio Nervoso/métodos , Dor Pós-Operatória/prevenção & controle , Músculos Abdominais , Idoso , Animais , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Manejo da Dor/métodos , Dor Pós-Operatória/etiologia , Procedimentos Cirúrgicos Operatórios/efeitos adversos
5.
Echocardiography ; 37(6): 913-916, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32472553

RESUMO

Tricuspid valve (TV) degeneration after surgical repair with an annuloplasty ring is problematic as redo operation carries high mortality. This can be addressed with transcatheter therapies to implant a valve within in prior ring (tricuspid valve-in-ring). When an incomplete ring is present, paravalvular leak is commonly encountered after tricuspid valve-in-ring (TViR) implant; however, this can be addressed with paravalvular leak closure devices. Multimodality imaging including cardiac computed tomography and three-dimensional (3D) transesophageal echocardiography (TEE) are important for successful TViR implant. We report a case of tricuspid regurgitation after tricuspid repair with an incomplete annuloplasty ring and subsequent paravalvular leak closure.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/cirurgia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
6.
Pacing Clin Electrophysiol ; 42(2): 146-152, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30548869

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly used to treat severe aortic stenosis. A frequent complication of TAVR is high-grade or complete atrioventricular (AV) block requiring a permanent pacemaker (PPM). There are little data on the long-term dependency on pacing after TAVR. The objective of this study was to determine the proportion of patients receiving a PPM for high-grade or complete AV block after TAVR who remain dependent on the PPM in follow-up and to determine any risk factors for, particularly the effect of postballoon dilation (PBD) on, pacemaker dependency. METHODS: Of 594 consecutive patients without prior PPM undergoing TAVR (81.9% balloon-expandable, 18.1% self-expandable valve), 67 (13.1%) received a PPM after TAVR. PPM dependency was defined as AV block with a ventricular escape rate of ≤ 40 beats/min. Patient and procedural characteristics were examined according to PPM dependency status. RESULTS: Of the 67 patients who received a PPM within 10 days after TAVR, 27/67 (40.3%) were dependent at first follow-up and only 9/41 (21.9%) at 1 year. PPM dependency was more common after a self-expanding valve (76.9% vs 31.5%, P < 0.01), in those who underwent PBD (66.7% vs 24.4%, P < 0.01), and in patients in persistent complete AV block at PPM implantation (62.5% vs 7.4%, P < 0.01). CONCLUSIONS: Fewer than half of patients who receive a new PPM following TAVR are pacemaker dependent at early follow-up (< 30 days). The use of self-expanding valves and PBD are associated with a markedly increased risk of PPM dependency.


Assuntos
Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/terapia , Marca-Passo Artificial , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/fisiopatologia , Feminino , Sistema de Condução Cardíaco , Humanos , Masculino , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/fisiopatologia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco
7.
Catheter Cardiovasc Interv ; 89(5): 860-865, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27468705

RESUMO

OBJECTIVES: We studied the impact of operator experience on trans-radial (TR) cardiac catheterization performance in contemporary practice. BACKGROUND: TR cardiac catheterization offers advantages over trans-femoral (TF) cardiac catheterization, but the TR approach has been slowly adopted in the United States. METHODS: We reviewed all cases of attempted TR cardiac catheterization at a single tertiary care medical center from May 2008 until April 2015. We classified the attending operator TR case experience at the time of each case, and the control group constituted cases performed by operators with >300 TR cases. Study endpoints were TR cannulation failure, TF cross-over, contrast medium dose, and fluoroscopy time. RESULTS: Over the study period, 4177 attempted TR cardiac catheterization cases were performed. The percentage of TR cases performed with percutaneous coronary intervention (PCI) increased from 14.0% in 2009 to 30.2% in 2015 (P-trend <0.001). The rate of TR cannulation failure decreased from 4.3% in 2009 to 2.0% in 2015 (P-trend = 0.071), and the rate of TF cross-over decreased from 4.3% in 2009 to 3.2% in 2015 (P-trend = 0.034). Operators with over 100 cases had the lowest odds of TR cannulation failure, while operators with over 200 cases had the lowest odds of TF cross-over. Operators with over 200 cases used the lowest mean contrast medium dose and mean fluoroscopy time. CONCLUSIONS: Increasing operator TR experience is associated with lower odds of TR cannulation failure and TF cross-over, as well as lower contrast medium dose and fluoroscopy time. © 2016 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/métodos , Cardiologia/educação , Competência Clínica , Doença da Artéria Coronariana/diagnóstico , Educação Médica Continuada/métodos , Intervenção Coronária Percutânea/educação , Doença da Artéria Coronariana/cirurgia , Feminino , Seguimentos , Humanos , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Artéria Radial , Estudos Retrospectivos , Fatores de Tempo
8.
Catheter Cardiovasc Interv ; 89(7): 1286-1291, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27566989

RESUMO

OBJECTIVES: We assessed whether post-operative delirium is associated with healthcare utilization and overall survival after trans-catheter aortic valve replacement. BACKGROUND: Delirium, a common syndrome among hospitalized older adults, is associated with increased morbidity and mortality. METHODS: We reviewed 294 transcatheter aortic valve replacement cases between June 2008 and February 2015 at a tertiary care academic medical center. Post-operative delirium was identified by confusion assessment method screening and clinician diagnosis. RESULTS: Delirium was identified in 61 patients (21%). Non-femoral access for trans-catheter aortic valve replacement was more common in delirious patients than in non-delirious patients (41% vs. 27%, P = 0.04). Delirious patients had diminished overall survival after trans-catheter aortic valve replacement compared to non-delirious patients (1-year survival 59% vs. 84%, log-rank P = 0.002). After adjusting for age, Society of Thoracic Surgeons predicted 30-day mortality, and access type; delirium remained independently associated with diminished overall survival (hazard ratio 2.01, 95% confidence interval 1.21-3.33, P = 0.007). The delirium group had longer mean hospital stay (13.3 ± 9.5 days vs. 6.7 ± 3.8 days, P < 0.001) and a higher rate of discharge to a rehabilitation facility (61% vs. 27%, P < 0.001), but there was no difference in 30-day hospital re-admission rates or 30-day mortality based on delirium status. CONCLUSIONS: Delirium occurs in one out of five patients after trans-catheter aortic valve replacement and is associated with diminished survival and increased healthcare utilization. Further studies are needed to clarify whether strategies aimed at reducing delirium after trans-catheter aortic valve replacement may improve outcomes in this high-risk subset. © 2016 Wiley Periodicals, Inc.


Assuntos
Delírio/terapia , Recursos em Saúde/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Delírio/diagnóstico , Delírio/etiologia , Delírio/mortalidade , Feminino , Humanos , Tempo de Internação , Masculino , Alta do Paciente , Modelos de Riscos Proporcionais , Centros de Reabilitação , Estudos Retrospectivos , Fatores de Risco , Centros de Atenção Terciária , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
11.
Curr Atheroscler Rep ; 18(5): 27, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27021619

RESUMO

Severe aortic stenosis (AS) is a life-threatening condition when left untreated. Aortic valve replacement (AVR) is the gold standard treatment for the majority of patients; however, transcatheter aortic valve implantation/replacement (TAVI/TAVR) has emerged as the preferred treatment for high-risk or inoperable patients. The concept of transcatheter heart valves originated in the 1960s and has evolved into the current Edwards Sapien and Medtronic CoreValve platforms available for clinical use. Complications following TAVI, including cerebrovascular events, perivalvular regurgitation, vascular injury, and heart block have decreased with experience and evolving technology, such that ongoing trials studying TAVI in lower risk patients have become tenable. The multidisciplinary team involving the cardiac surgeon and cardiologist plays an essential role in patient selection, procedural conduct, and perioperative care.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Cateterismo Cardíaco , Humanos , Seleção de Pacientes , Complicações Pós-Operatórias
12.
Catheter Cardiovasc Interv ; 85(5): 828-31, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25381962

RESUMO

We describe a case of a 75-year-old woman presenting emergently with an anterior S-T elevation myocardial infarction that deteriorated into ventricular fibrillation requiring prompt resuscitation, resulting in cardiogenic shock. Emergency primary percutaneous coronary intervention of the left anterior descending coronary artery with adjunctive abciximab and heparin resulted in adequate coronary flow, and intra-aortic balloon pump was used to support hemodynamics. Within one hour of intervention, she developed acute respiratory distress with four-quadrant opacification of lung fields, difficulty with oxygenation, and hypotension. Emergency bronchoscopy revealed diffuse erythematous proximal airways with bloody secretions bilaterally confirming diffuse alveolar hemorrhage. An emergency veno-arterial extracorporeal membranous oxygenation (ECMO) circuit was placed at the bedside, acutely improving oxygenation and hemodynamics. She survived the hospitalization with multiple complications related to access site and prolonged intensive care unit stay, was discharged to acute rehabilitation. She is currently thriving 18 months post-procedure. This case highlights the use of ECMO in the often-fatal condition of diffuse alveolar hemorrhage related to glycoprotein inhibitor use.


Assuntos
Anticorpos Monoclonais/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Hemoptise/induzido quimicamente , Técnicas Hemostáticas , Fragmentos Fab das Imunoglobulinas/efeitos adversos , Abciximab , Idoso , Anticorpos Monoclonais/uso terapêutico , Feminino , Seguimentos , Hemoptise/terapia , Humanos , Fragmentos Fab das Imunoglobulinas/uso terapêutico , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Alvéolos Pulmonares
13.
Mediators Inflamm ; 2015: 379501, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25861161

RESUMO

The use of combined hormonal contraceptives has been reported to increase the level of C-reactive protein (CRP). We assessed the effect of hormonal contraceptive use on inflammatory cytokines including CRP, monocyte chemotactic protein-1, soluble tumor necrosis factor (sTNF), interleukin-6 (IL-6), and soluble CD40 ligand. We used 79 female subjects (19 to 30 years old) who were combined oral contraceptives users (n = 29), combined vaginal contraceptive users (n = 20), and nonusers (n = 30) with CRP values of ≤1 (n = 46) or ≥3 (n = 33). Information on medical history, physical activities, and dietary and sleeping habits were collected. Both oral and vaginal contraceptive users had higher levels of CRP (P < 0.0001), compared to nonusers. Only oral contraceptive users exhibited elevated sCD40L (P < 0.01). When comparing the groups with CRP ≤ 1 and CRP ≥ 3, levels of IL-6 and sTNF-RI were positively correlated with CRP among oral contraceptive users. We did not observe the same elevation for other inflammatory biomarkers for the CRP ≥ 3 group among vaginal contraceptive users. The clear cause of elevation in CRP level due to the use of different hormonal contraceptive formulations and methods is not well understood. Longitudinal studies with larger sample size are required to better assess the true cause of CRP elevation among hormonal contraceptive users.


Assuntos
Proteína C-Reativa/análise , Dispositivos Anticoncepcionais Femininos , Anticoncepcionais Orais Hormonais/farmacologia , Adulto , Biomarcadores/sangue , Ligante de CD40/sangue , Feminino , Humanos , Interleucina-6/sangue , Receptores Tipo I de Fatores de Necrose Tumoral/sangue
14.
Artigo em Inglês | MEDLINE | ID: mdl-38950772

RESUMO

OBJECTIVE: Aortic root replacement requires construction of a composite valve-graft and reimplantation of coronary arteries. This study assessed the feasibility of valve-in-valve transcatheter aortic valve implantation after aortic root replacement. METHODS: A retrospective review was conducted on 74 consecutive patients who received a composite valve-graft at a single institution from 2019 to 2021. Forty patients had bioprosthetic valves with adequate postoperative gated computed tomographic angiography scans. Computational simulations of balloon and self-expanding transcatheter valve deployments were performed. The modeled coronary distances were compared to traditional, manually measured valve-to-coronary distances. RESULTS: There was a statistically significant difference in the modeled versus manual measurements of valve to coronary distances were for all patients regardless of valve type or coronary artery analyzed (p <0. 05). Most patients are low risk for coronary obstruction per three-dimensional modeling including those with a valve-to-coronary distance <4 millimeters. Only one patient (2.5%) was at risk for coronary obstruction for the left coronary artery using a ballonvalve. No other valve combination was considered high risk of coronary obstruction. Five patients (12.5%) were at risk for possible valve stent deformation at the outflow, due to angulation at the graft anastomosis. CONCLUSIONS: Following aortic root replacement, all patients were candidates for Valve-in-Valve using one or both types of transcatheter heart valves. Self-expanding valves may be at higher risk for stent frame deformation at graft anastomotic lines and balloon-expandable valves may be at higher risk of coronary obstruction.

15.
Struct Heart ; 8(2): 100264, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38481712

RESUMO

Background: Transcatheter mitral valve-in-valve (MViV) replacement has emerged as an alternative to redo mitral valve (MV) surgery for the management of failed bioprosthetic MVs. The degree of cardiac remodeling assessed by echocardiography has been shown to have prognostic implications in degenerative mitral regurgitation patients undergoing MV surgery. The impact of transcatheter MViV in patients with degenerative bioprosthetic MV failure on cardiac remodeling and its associated prognosis remains undescribed. Objectives: The aim of this study is to describe the early anatomic and functional changes of the left-sided chambers and right ventricle by echocardiography posttranscatheter MViV intervention and their impact on mortality outcomes. Additionally, we sought to analyze the outcome of heart failure in bioprosthetic MV failure patients undergoing transcatheter MViV replacement. Methods: We analyzed consecutive patients undergoing MViV intervention for symptomatic bioprosthetic MV failure. Echocardiograms before intervention and within 100 days postintervention were analyzed. A chart review was performed to obtain baseline characteristics, follow-up visits, 30-day heart failure and 1-year all-cause mortality outcomes. Results: A total of 62 patients (mean age 69 ± 13 years, 61% male) were included in the study. Most patients were undergoing MViV intervention for prosthetic mitral stenosis n = 48 (77.4%) and the rest for mitral regurgitation or mixed disease. Compared with baseline, significant reductions were observed in median left atrial volume (LAV; 103 [81-129] ml vs. 95.2 [74.5-117.5] ml, p < 0.01) and mean (SD) left atrial conduit strain (9.1% ± 5.2% vs. 10.8% ± 4.8%, p = 0.039) within 100 days postintervention. Early reduction in right ventricular free wall global longitudinal strain and fractional area change also occurred postintervention. No significant change in left ventricular chamber dimensions or ejection fraction was observed. During the 1-year follow up period, 5 (8%) patients died. While baseline LAV was not associated with 1-year all-cause mortality (OR 0.98 CI 0.95-1.01; p = 0.27), a change in LAV in the follow up period was associated with all-cause mortality at 1 year (OR 1.06 CI 1.01-1.12; p = 0.023). At 30 days postintervention, 65% of patients had an improvement in their New York Heart Association functional class. Conclusion: In this retrospective study of patients undergoing transcatheter MViV intervention for failed bioprosthetic MVs, early reverse remodeling of the left atrium occurs within 100 days postintervention and reduction in LAV is associated with reduced all-cause mortality at 1 year. In addition, there is significant improvement in heart failure symptoms at 30 days following intervention but further investigation into the longitudinal remodeling changes and long-term outcomes is needed.

16.
Ann Thorac Surg ; 2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38286202

RESUMO

BACKGROUND: The management of aortic stenosis has evolved to stratification by age as reflected in recent societal guidelines. We evaluated age-stratified surgical aortic valve replacement (SAVR) trends and outcomes in patients with bicuspid aortic valve (BAV) or tricuspid aortic valve (TAV) from The Society of Thoracic Surgeons Adult Cardiac Surgery Database. METHODS: This cohort included adults (≥18 years) undergoing SAVR for severe aortic stenosis between July 2011 and December 2022. Comparisons were stratified by age (<65 years, 65-79 years, ≥80 years) and BAV or TAV status. Primary end points included operative mortality, composite morbidity and mortality, and permanent stroke. Observed to expected ratios by The Society of Thoracic Surgeons predicted risk of mortality were calculated. RESULTS: In total, 200,849 SAVR patients (55,326 BAV [27.5%], 145,526 TAV [72.5%]) from 1238 participating hospitals met study criteria. Annual SAVR volumes decreased by 45% (19,560 to 10,851) during the study period. The decrease was greatest (96%) for patients ≥80 years of age (4914 to 207). The relative prevalence of BAV was greater in younger patients (<65 years, 69,068 [49.5% BAV]; 65-79 years, 104,382 [19.1% BAV]; ≥80 years, 27,399 [4.5% BAV]). The observed mortality in <80-year-old BAV patients (<65 years, 1.08; 65-79 years, 1.21; ≥80 years, 3.68) was better than the expected mortality rate (<65 years, 1.22; 65-79 years, 1.54; ≥80 years, 3.14). CONCLUSIONS: SAVR volume in the transcatheter era has decreased substantially, particularly for patients ≥80 years old and for those with TAV. Younger patients with BAV have better than expected outcomes, which should be carefully considered during shared decision-making in the treatment of aortic stenosis. SAVR should remain the preferred therapy in this population.

17.
JACC Asia ; 4(4): 292-302, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38660112

RESUMO

Background: Sex-related disparities in clinical outcomes following transcatheter aortic valve replacement (TAVR) and the impact of sex on clinical outcomes after TAVR among different racial groups are undetermined. Objectives: This study assessed whether sex-specific differences in baseline clinical and anatomical characteristics affect clinical outcomes after TAVR and investigated the impact of sex on clinical outcomes among different racial groups. Methods: The TP-TAVR (Trans-Pacific TAVR) registry is a multinational cohort study of patients with severe aortic stenosis who underwent TAVR at 2 major centers in the United States and 1 major center in South Korea. The primary outcome was a composite of death from any cause, stroke, or rehospitalization after 1 year. Results: The incidence of the primary composite outcome was not significantly different between sexes (27.9% in men vs 28% in women; adjusted HR: 0.97; 95% CI: 0.79-1.20). This pattern was consistent in Asian (23.5% vs 23.3%; adjusted HR: 0.99; 95% CI: 0.69-1.41) and non-Asian (30.8% vs 31.6%; adjusted HR: 0.95; 95% CI: 0.72-1.24) cohorts, without a significant interaction between sex and racial group (P for interaction = 0.74). The adjusted risk for all-cause mortality was similar between sexes, regardless of racial group. However, the adjusted risk of stroke was significantly lower in male patients than in female patients, which was more prominent in the non-Asian cohort. Conclusions: Despite significantly different baseline and procedural characteristics, there were no sex-specific differences in the adjusted 1-year rates of primary composite outcomes and all-cause mortality, regardless of different racial groups. (Transpacific TAVR registry [TP-TAVR]; NCT03826264).

18.
JACC Heart Fail ; 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38934964

RESUMO

BACKGROUND: The REDUCE LAP-HF II (Reduce Elevated Left Atrial Pressure in Patients With Heart Failure II) trial found that, compared with a sham procedure, the Corvia Atrial Shunt did not improve outcomes in heart failure with preserved or mildly reduced ejection fraction. However, after 12-month follow-up, "responders" (peak-exercise pulmonary vascular resistance <1.74 WU and absence of a cardiac rhythm management device) were identified. OBJECTIVES: This study sought to determine: 1) the overall efficacy and safety of the atrial shunt vs sham control after 2 years of follow-up; and 2) whether the benefits of atrial shunting are sustained in responders during longer-term follow-up or are offset by adverse effects of the shunt. METHODS: The study analyzed 2-year outcomes in the overall REDUCE LAP-HF II trial, as well as in responder and nonresponder subgroups. The primary endpoint was a hierarchical composite of cardiovascular death or nonfatal ischemic/embolic stroke, total heart failure events, and change in health status. RESULTS: In 621 randomized patients, there was no difference between the shunt (n = 309) and sham (n = 312) groups in the primary endpoint (win ratio: 1.01 [95% CI: 0.82-1.24]) or its individual components at 2 years. Shunt patency at 24 months was 98% in shunt-treated patients. Cardiovascular mortality and nonfatal ischemic stroke were not different between the groups; however, major adverse cardiac events were more common in those patients assigned to the shunt compared with sham (6.9% vs 2.7%; P = 0.018). More patients randomized to the shunt had an increase in right ventricular volume of ≥30% compared with the sham control (39% vs 28%, respectively; P < 0.001), but right ventricular dysfunction was uncommon and not different between the treatment groups. In responders (n = 313), the shunt was superior to sham (win ratio: 1.36 [95% CI: 1.02-1.83]; P = 0.037, with 51% fewer HF events [incidence rate ratio: 0.49 [95% CI: 0.25-0.95]; P = 0.034]). In nonresponders (n = 265), atrial shunting was inferior to sham (win ratio: 0.73 [95% CI: 0.54-0.98]). CONCLUSIONS: At 2 years of follow-up in REDUCE LAP-HF II, there was no difference in efficacy between the atrial shunt and sham groups in the overall trial group. The potential clinical benefit identified in the responder group after 1 and 2 years of follow-up is currently being evaluated in the RESPONDER-HF (Re-Evaluation of the Corvia Atrial Shunt Device in a Precision Medicine Trial to Determine Efficacy in Mildly Reduced or Preserved Ejection Fraction Heart Failure) trial. (Reduce Elevated Left Atrial Pressure in Patients With Heart Failure II [REDUCE LAP-HF II]; NCT03088033).

19.
Front Cardiovasc Med ; 10: 1204736, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37363090

RESUMO

We present unusual coronary-pulmonary collaterals in a 65-year-old CTEPH patient. Perfusion mapping of a dual-energy computed tomography (DECT) study revealed areas of right lung that were minimally perfused despite unilateral occlusion of the right pulmonary artery, leading to the discovery of coronary-pulmonary collaterals via invasive coronary angiography. Pulmonary thromboendarterectomy removed the clot en-bloc. Post-surgery DECT and catheterization confirmed restoration of pulmonary arterial circulation and excellent hemodynamic response. Here, suggestion of perfusion to a proximally obstructed lung with DECT helped to document the presence of rarely documented coronary-pulmonary artery collaterals.

20.
JAMA Intern Med ; 183(11): 1214-1220, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37721765

RESUMO

Importance: US hospitals are required to publicly post their prices for specified shoppable services online. However, the extent to which a hospital's prices posted online correlate with the prices they give to a telephone caller is unknown. Objective: To compare hospitals' online cash prices for vaginal childbirth and brain magnetic resonance imaging (MRI) with prices offered to secret shopper callers requesting price estimates by telephone. Design, Setting, and Participants: This cross-sectional study included cash online prices from each hospital's website for vaginal childbirth and brain MRI collected from representative US hospitals between August and October 2022. Thereafter, again between August and October 2022, simulated secret shopper patients called each hospital requesting their lowest cash price for these procedures. Main Outcomes and Measures: We calculated the difference between each hospital's online and phone prices for vaginal childbirth and brain MRI, and the Pearson correlation coefficient (r) between the online and phone prices for each procedure, among hospitals able to provide both prices. Results: A total of 60 representative US hospitals (20 top-ranked, 20 safety-net, and 20 non-top-ranked, non-safety-net hospitals) were included in the analysis. For vaginal childbirth, 63% (12 of 19) of top-ranked hospitals, 30% (6 of 20) of safety-net hospitals, and 21% (4 of 19) of non-top-ranked, non-safety-net hospitals provided both online and telephone prices. For brain MRI, 85% (17 of 20) of top-ranked hospitals, 50% (10 of 20) of safety-net hospitals, and 100% (20 of 20) of non-top-ranked, non-safety-net hospitals provided prices both online and via telephone. Online prices and telephone prices for both procedures varied widely. For example, online prices for vaginal childbirth posted by top-ranked hospitals ranged from $0 to $55 221 (mean, $23 040), from $4361 to $14 377 (mean $10 925) for safety-net hospitals, and from $1183 to $30 299 (mean $15 861) for non-top-ranked, non-safety-net hospitals. Among the 22 hospitals providing prices both online and by telephone for vaginal childbirth, prices were within 25% of each other for 45% (10) of hospitals, while 41% (9) of hospitals had differences of 50% or more (Pearson r = 0.118). Among the 47 hospitals providing both online and phone prices for brain MRI, prices were within 25% of each other for 66% (31) of hospitals), while 26% (n = 12) had differences of 50% or more (Pearson r = -0.169). Among hospitals that provided prices both online and via telephone, there was a complete match between the online and telephone prices for vaginal childbirth in 14% (3 of 22) of hospitals and for brain MRI in 19% (9 of 47) of hospitals. Conclusions and Relevance: Findings of this cross-sectional study suggest that there was poor correlation between hospitals' self-posted online prices and prices they offered by telephone to secret shoppers. These results demonstrate hospitals' continued problems in knowing and communicating their prices for specific services. The findings also highlight the continued challenges for uninsured patients and others who attempt to comparison shop for health care.


Assuntos
Hospitais , Telefone , Feminino , Humanos , Estudos Transversais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA