1.
Arch Orthop Trauma Surg ; 144(5): 2127-2129, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38494566

RESUMO

INTRODUCTION: Time-efficiency of individually wrapped screws versus screws in a screw rack is not well established. MATERIALS AND METHODS: We performed a prospective single-center clinical study timing the interval between the surgeon asking and receiving a screw during plate and screw osteosynthesis of distal radius fractures. Patients were randomized for individually wrapped screws or screws in a screw rack. The study was conducted in a Level 1 Trauma Center and surgeries were performed between March and June 2023. RESULTS: Average handling time for screws from a screw rack was 9 s (SD 5.5; range 3-28) and 22 s for individually wrapped screws (SD 6.1; range 6-38). This average difference of 13 s is significant (p < 0.0001). CONCLUSION: There is a significant increase in handling time using individually wrapped screws over using a screw rack. LEVEL OF EVIDENCE: Level I (therapeutic, randomized controlled trial).


Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas , Fraturas do Rádio , Humanos , Fraturas do Rádio/cirurgia , Estudos Prospectivos , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Idoso , Duração da Cirurgia , Idoso de 80 Anos ou mais , Fraturas do Punho