Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Audiol Neurootol ; : 1-7, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38631316

RESUMO

INTRODUCTION: Purpose of our study was to compare two competing methods of performing bisyllabic word speech audiometry for the detection of the 50% speech reception threshold in noise (SRT50). METHODS: Classic method is performed submitting multiple word lists at a fixed signal-to-noise ratio. A newer Fast method - Italian Fast Speech Reception Threshold 50 (IFastSRT50) - is performed by means of program software with a single list of bisyllabic words and noise intensity shifting. RESULTS: Means comparison between SRT50 Classic and IFastSRT50 shows a slight significant correlation (r = 0.263; p = 0.044) and a wide significant difference: SRT50 Classic = -2.763 dB (SD = 4.1) and IFastSRT50 = -7.803 dB (SD = 2.1) (p < 0.0001). There is a high difference between the test execution time means (SRT50 Classic = 11 min, IFastSRT50 = 2 min; p < 0.0001). The correlation between test results and execution times was higher for SRT50 Classic than IFastSRT50. CONCLUSION: IFastSRT50 test is a reliable method to quickly investigate signal-to-noise ratio needed to obtain 50% of recognition scores with bisyllabic words; it allows less execution time than SRT50 Classic method and can avoid patient fatigue and other limitations of different speech discrimination tests in noise as sentences based ones.

2.
Medicina (Kaunas) ; 59(2)2023 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-36837553

RESUMO

Background and objectives: Otoferlin is a multi-C2 domain protein implicated in neurotransmitter-containing vesicle release and replenishment of the cochlear inner hair cell (IHC) synapses. Mutations in the OTOF gene have been associated with two different clinical phenotypes: a prelingual severe-to-profound sensorineural hearing loss (ANSD-DFNB9); and the peculiar temperature-sensitive auditory neuropathy (TS-ANSD), characterized by a baseline mild-to-moderate hearing threshold that worsens to severe-to-profound when the body temperature rises that returns to a baseline a few hours after the temperature has fallen again. The latter clinical phenotype has been described only with a few OTOF variants with an autosomal recessive biallelic pattern of inheritance. Case report: A 7-year-old boy presented a picture compatible with TS-ANSD exacerbated by febrile states or physical exercise with mild-to-moderate hearing loss at low and medium frequencies and a decrease in speech discrimination that worsened with an unfavorable speech-to-noise ratio. Otoacoustic emissions (OAEs) were present whereas auditory brainstem responses (ABRs) evoked by a click or tone-burst were generally absent. No inner ear malformations were described from the CT scan or MRI. Next-generation sequencing (NGS) of the known deafness genes and multi-phasic bioinformatic analyses of the data detected in OTOF a c.2521G>A missense variant and the deletion of 7.4 Kb, which was confirmed by array-comparative genomic hybridization (array-CGH). The proband's parents, who were asymptomatic, were tested by Sanger sequencing and the father presented the c.2521G>A missense variant. Conclusions: The picture presented by the patient was compatible with OTOF-induced TS-ANSD. OTOF has been generally associated with an autosomal recessive biallelic pattern of inheritance; in this clinical report, two pathogenic variants never previously associated with TS-ANSD were described.


Assuntos
Perda Auditiva Central , Perda Auditiva Neurossensorial , Humanos , Hibridização Genômica Comparativa , Perda Auditiva Central/genética , Perda Auditiva Neurossensorial/genética , Proteínas de Membrana/genética , Mutação , Temperatura , Masculino , Criança
3.
Eur Arch Otorhinolaryngol ; 278(7): 2239-2246, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32833054

RESUMO

AIM: The fully implantable middle ear implant (C-FI-MEI) is designed for patients with moderate-to-severe sensorineural hearing loss or those with mixed hearing loss. To analyze the audiological post-operative results of subjects bilaterally implanted with C-FI-MEI. MATERIALS AND METHODS: Retrospective study: 14 patients with bilateral, moderate-to-severe, sensorineural or mixed hearing loss were treated. This clinical sample included 14 cases bilaterally implanted (13 sequentially, 1 simultaneously). The evaluation at each follow-up after surgery included otologic examination, a structured interview, and different audiological tests composed of pure tone audiometry, speech in quiet and in noise test, and localization task. The mean follow-up was 67.2 ± 33 months. RESULTS: There were no significant differences between pre and post-operative pure tone averages. The patients showed no significant differences between pre-operatively aided and C-FI-MEI implant-aided conditions in terms of word recognition score. Speech perception in noise under different loudspeaker arrangements and localization tests demonstrated a binaural advantage in bilaterally implanted patients. The mean daily use time was 17.4 and 16.7 h, respectively, for right and left side. CONCLUSION: The results for the 14 patients, bilaterally implanted with C-FI-MEI, suggest that bilateral implantation of fully implantable middle ear hearing devices is an effective procedure. LEVEL OF EVIDENCE: 4.


Assuntos
Perda Auditiva Neurossensorial , Prótese Ossicular , Percepção da Fala , Audição , Perda Auditiva Neurossensorial/diagnóstico , Perda Auditiva Neurossensorial/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento
4.
Audiol Neurootol ; 24(2): 77-83, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31117068

RESUMO

OBJECTIVES: The aim of this study was to evaluate the results after cochlear implant (CI) in elderly patients and to compare them to those obtained in younger adult patients. A possible correlation between the results in older CI recipients and some variables of the patients was also investigated. METHODS: The sample consisted of 107 patients over 40 years of age at surgery divided into 3 subgroups according to age at implantation. Results in terms of speech perception in silence and with background noise were compared between the 3 groups. The patients also completed the Glasgow Benefits Inventory (GBI) questionnaire. RESULTS: Older patients achieved significant benefits after CI with regard to speech perception in silence and with background noise. We also recorded benefits for the GBI. DISCUSSION: In line with the literature, our data confirm that CI is an effective procedure also in elderly patients, conferring benefits in speech perception and quality of life.


Assuntos
Implantes Cocleares/psicologia , Qualidade de Vida/psicologia , Percepção da Fala , Adulto , Idoso , Idoso de 80 Anos ou mais , Limiar Auditivo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medida da Produção da Fala , Inquéritos e Questionários
5.
Eur Arch Otorhinolaryngol ; 275(11): 2643-2652, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30191304

RESUMO

PURPOSE: The aim of this work is to study otosclerotic patients by 3D-FLAIR (fluid attenuated inversion recovery) sequence magnetic resonance imaging (MRI) with and without Gadolinium administration (-/+ Gd), to understand whether there is a direct relationship between radiological findings at 3D FLAIR MRI sequences and some clinical features of otosclerosis, such as the presence and entity of sensorineural involvement, duration of disease, patient gender, and other factors. METHODS: 38 patients affected by different stages of unilateral or bilateral otosclerosis underwent 3D FLAIR MRI+/- Gd. 11 subjects with normal hearing, previously submitted to 3T MRI for other minor diseases, unrelated with otosclerosis, had been retrospectively enrolled as control group. RESULTS: We found significant correlations between 3D FLAIR MRI findings and some clinical features of otosclerosis, such as severity of cochlear damage (in terms of entity of sensorineural loss) and duration of disease. These findings indicate that at 3D-FLAIR MRI different patterns may depend on the level of blood labyrinth barrier damage in the cochlea, and be related to different stages of cochlear involvement in otosclerotic patients. CONCLUSIONS: We believe that our findings may contribute in understanding the pathogenesis of cochlear damage in otosclerosis and may have further prognostic value. Our results led us to consider the possible use of 3D-FLAIR sequences in monitoring the effectiveness of any medical therapy of otosclerosis and in selecting the patients eligible for treatment.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Otosclerose/diagnóstico por imagem , Estudos de Casos e Controles , Meios de Contraste , Feminino , Gadolínio , Perda Auditiva Neurossensorial/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença
6.
Audiol Neurootol ; 22(4-5): 226-235, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29232662

RESUMO

Currently, there are no studies assessing everyday use of cochlear implant (CI) processors by recipients by means of objective tools. The Nucleus 6 sound processor features a data logging system capable of real-time recording of CI use in different acoustic environments and under various categories of loudness levels. In this study, we report data logged for the different scenes and different loudness levels of 1,366 CI patients, as recorded by SCAN. Monitoring device use in cochlear implant recipients of all ages provides important information about the listening conditions encountered in recipients' daily lives that may support counseling and assist in the further management of their device settings. The findings for this large cohort of active CI users confirm differences between age groups concerning device use and exposure to various noise environments, especially between the youngest and oldest age groups, while similar levels of loudness were observed.


Assuntos
Percepção Auditiva/fisiologia , Implante Coclear , Implantes Cocleares , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Ruído , Som , Percepção da Fala/fisiologia , Adulto Jovem
7.
Eur Radiol ; 26(10): 3744-51, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26747254

RESUMO

PURPOSE: To assess the capability of three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) sequences in detecting signal alterations of the endolabyrinthine fluid in patients with otosclerosis. MATERIALS AND METHODS: 3D-FLAIR before and after (-/+) gadolinium (Gd) administration was added to the standard MR protocol and acquired in 13 patients with a clinical/audiological diagnosis of severe/profound hearing loss in otosclerosis who were candidates for cochlear implantation and in 11 control subjects using 3-T magnetic resonance imaging (MRI) equipment. The MRI signal of the fluid-filled cochlea was assessed both visually and calculating the signal intensity ratio (SIR = signal intensity cochlea/brainstem). RESULTS: We revealed no endocochlear signal abnormalities on T1-weighted -/+ Gd images for either group, while on 3D-FLAIR we found bilateral hyperintensity with enhancement after Gd administration in eight patients and bilateral hyperintensity without enhancement in one patient. No endocochlear signal abnormalities were detected in other patients or the control group. CONCLUSION: Using 3-T MRI equipment, the 3D-FLAIR -/+ Gd sequence is able to detect the blood-labyrinth barrier (BLB) breakdown responsible for alterations of the endolabyrinthine fluid in patients with cochlear otosclerosis. We believe that 3D-FLAIR +/- Gd is an excellent imaging modality to assess the intra-cochlear damage in otosclerosis patients. KEY POINTS: • Gd-enhanced T1-weighted MRI has limited application to detect intra-cochlear damage. • 3D-FLAIR is less sensitive to flux artefacts and allows multiplanar reconstruction. • Post-Gd 3D-FLAIR is advantageous as it may highlight the BLB breakdown. • Using 3D-FLAIR -/+ Gd, we were able to identify intra-cochlear signal hyperintensities. • 3D-FLAIR might be applied for monitoring disease progression and treatment response.


Assuntos
Otosclerose/diagnóstico por imagem , Adulto , Idoso , Artefatos , Estudos de Casos e Controles , Cóclea/diagnóstico por imagem , Implante Coclear , Meios de Contraste , Orelha Interna/diagnóstico por imagem , Feminino , Gadolínio , Gadolínio DTPA , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Otosclerose/cirurgia
8.
Eur Arch Otorhinolaryngol ; 273(11): 3631-3640, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27007286

RESUMO

The Carina© system (Cochlear Ltd, Sydney, Australia) is a totally implantable prosthesis designed to meet the needs of acoustic amplification in adults with moderate-to-severe sensorineural or mixed hearing loss. It mechanically stimulates the ossicles or labyrinthine windows. The object of this study was to update surgical and functional results obtained in a consistent sample of Carina© recipients. The data sheets of 26 patients who underwent Carina© surgery at two ENT units [i.e., ENT Audiology and Phoniatrics Unit of the University Hospital of Pisa (Pisa, Italy) and ENT Unit of "Guglielmo da Saliceto" Hospital of Piacenza (Piacenza, Italy)] were evaluated for the surgical and audiological outcomes. Twenty patients received a unilateral device, whereas six patients were bilaterally implanted (simultaneously in one patient and sequentially in the remaining five patients). The total number of ears implanted in this study was 32. Most implanted patients expressed a high degree of satisfaction with the prosthesis, which highlights the improvement in hearing in different environmental conditions, the cosmetic advantages, and greater freedom in performing common activities in daily living. Audiological examination demonstrated valid functional gain and significant improvement in speech perception in quiet. Based on this experience, the Carina© is a valid alternative to hearing aids. Moreover, a bilateral implantation, even a simultaneous implantation, is a viable option for selected motivated patients because the intervention is generally well tolerated and the surgery time is relatively fast.


Assuntos
Auxiliares de Audição , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Perda Auditiva Neurossensorial/cirurgia , Próteses e Implantes , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Percepção da Fala , Adulto Jovem
9.
J Hum Genet ; 60(12): 777-80, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26354035

RESUMO

Here, we report on a patient with a 625 kb duplication in Xp22.12, detected by array comparative genomic hybridization (CGH). The duplicated region contains only one gene, RPS6KA3, that results in partial duplication. The same duplication was present in his mother and his maternal uncle. This partial duplication inhibits the RPS6KA3 expression, mimicking the effect of loss-of-function mutations associated with Coffin-Lowry syndrome (CLS). The phenotype of the patient here presented is not fully evocative of this syndrome because he does not present some of the facial, digital and skeletal abnormalities that are considered the main diagnostic features of CLS. This case is one of the few examples where RPS6KA3 mutations are associated with a non-specific X-linked mental retardation.


Assuntos
Duplicação Cromossômica , Cromossomos Humanos X/genética , Doenças Genéticas Ligadas ao Cromossomo X/genética , Deficiência Intelectual/genética , Proteínas Quinases S6 Ribossômicas 90-kDa/genética , Criança , Doenças Genéticas Ligadas ao Cromossomo X/enzimologia , Humanos , Deficiência Intelectual/enzimologia , Masculino
10.
Bioengineering (Basel) ; 11(2)2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38391679

RESUMO

Bone defects are a significant health problem worldwide. Novel treatment approaches in the tissue engineering field rely on the use of biomaterial scaffolds to stimulate and guide the regeneration of damaged tissue that cannot repair or regrow spontaneously. This work aimed at developing and characterizing new piezoelectric scaffolds to provide electric bio-signals naturally present in bone and vascular tissues. Mixing and extrusion were used to obtain nanocomposites made of polyhydroxybutyrate (PHB) as a matrix and barium titanate (BaTiO3) nanoparticles as a filler, at BaTiO3/PHB compositions of 5/95, 10/90, 15/85 and 20/80 (w/w%). The morphological, thermal, mechanical and piezoelectric properties of the nanocomposites were studied. Scanning electron microscopy analysis showed good nanoparticle dispersion within the polymer matrix. Considerable increases in the Young's modulus, compressive strength and the piezoelectric coefficient d31 were observed with increasing BaTiO3 content, with d31 = 37 pm/V in 20/80 (w/w%) BaTiO3/PHB. 3D printing was used to produce porous cubic-shaped scaffolds using a 90° lay-down pattern, with pore size ranging in 0.60-0.77 mm and good mechanical stability. Biodegradation tests conducted for 8 weeks in saline solution at 37 °C showed low mass loss (∼4%) for 3D printed scaffolds. The results obtained in terms of piezoelectric, mechanical and chemical properties of the nanocomposite provide a new promising strategy for vascularized bone tissue engineering.

11.
Ear Hear ; 34(3): e28-37, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23615459

RESUMO

OBJECTIVE: A growing number of studies on deaf children with cochlear implant (CI) document a significant improvement in receptive and expressive language skills after implantation, even if they show language delay when compared with normal-hearing peers. Data on language acquisition in CI Italian children are still scarce and limited to only certain aspects of language. The purpose of this study is to prospectively describe the trajectories of language development in early CI Italian children, with particular attention to the transition from first words to combinatorial speech and to acquisition of complex grammar in a language with rich morphology, such as Italian. DESIGN: Six children, with profound prelingual deafness, provided with CI, between 16 and 24 months of age were prospectively assessed and followed over a mean period of up to 34.8 months postimplant. During follow-up, each child received between four to five individual language evaluations through a combination of indirect procedures (parent reports of early lexical and grammar development) and direct ones (administration of standardized receptive and expressive language tests with Italian norms and collection of spontaneous language samples). RESULTS: In relation to chronological age, the acquisition of expressive vocabulary was delayed. However, considering the duration of hearing experience, most CI participants showed an earlier start and faster growth of expressive rather than receptive vocabulary in comparison with typically developing children. This quite atypical result persisted right up until the end of the follow-up. The acquisition of expressive grammar was delayed relative to chronological age, though all but one CI participant achieved the expected grammar level after approximately 3 years of CI use. In addition, the rate of grammar acquisition was not homogeneous during development, showing two different paces: one comparable with normal hearing in the transition from holophrastic to primitive combinatorial speech and a much slower one to attain more advanced levels of morphosyntactic control. CONCLUSION: From a rehabilitative viewpoint, our results suggest the importance of implementing rehabilitation in lexical comprehension, even when expressive vocabulary appears to be within normal range. Moreover, assessment of language acquisition in CI Italian children should focus on those grammar aspects that are more vulnerable to early acoustic deprivation (such as free and bound morphology) to ensure enhanced language therapy planning.


Assuntos
Implantes Cocleares , Surdez/reabilitação , Desenvolvimento da Linguagem , Pré-Escolar , Implante Coclear , Surdez/complicações , Feminino , Humanos , Lactente , Itália , Transtornos do Desenvolvimento da Linguagem/etiologia , Modelos Lineares , Estudos Longitudinais , Masculino , Testes Neuropsicológicos , Estudos Prospectivos , Vocabulário
12.
Brain Sci ; 13(10)2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37891748

RESUMO

Congenital unilateral hearing loss (UHL) represents a contemporary audiologic challenge. Children with UHL can struggle with understanding speech in noise, localizing sounds, developing language, and maintaining academic performance, leading to low self-esteem, anxiety, and decreased social support. Two specific conditions related to UHL in children are single-sided deafness (SSD) and unilateral auris atresia (UAA). This was a retrospective observational study on a group of children with UHL. The Simplified Italian Matrix Sentence Test was used for the assessment of speech reception threshold (SRT) in different conditions: speech and noise from the front (S0N0), speech at 45° from the side of the better ear and noise at 45° from the opposite side (SbNw), and vice versa (SwNb). Each test was conducted unaided, with a bone-anchored hearing device (BAHD), and with a remote microphone (RM) system. The use of a BAHD and RM led to an improvement in SRT in S0N0 and SwNb conditions. The SSD subgroup demonstrated significant benefits with both devices in SwNb, and the UAA subgroup from the use of BAHD in S0N0. In conclusion, the study underscores the potential benefits of both devices in enhancing speech perception for UHL children, providing insights into effective intervention strategies for these challenging cases.

13.
J Vis Exp ; (195)2023 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-37306419

RESUMO

Endolymphatic sac tumors (ELST) are low-grade papillary adenocarcinoma originating from the endolymphatic sac. Usually slow-growing, with local aggressiveness and a low risk of distant metastases, ELST can be sporadic but also frequently associated with von Hippel Lindau disease. The current treatment of ELST is primarily surgical resection. A 55-year-old woman accessed our otologic tertiary level referral center for a sudden worsening of hearing loss in her left ear and vertigo. A magnetic resonance (MRI) and computer tomography scan study subsequently showed a mass in the petrous bone; hence, the presence of an ELST was hypothesized. After embolization of the mass, the patient underwent surgical removal of the lesion. The resection of the mass was done through a translabirinthine approach, with an uneventful procedure. No residual disease remained after surgery. After 24 months of radiologic follow up with MRI, there are no signs of recurrence disease. This paper reports the management of this sporadic ELST, as well as the follow up results, providing clinicians this protocol for the handling of such a challenging otologic skull base surgery and rare disease.


Assuntos
Adenocarcinoma Papilar , Adenoma , Neoplasias Ósseas , Saco Endolinfático , Humanos , Feminino , Pessoa de Meia-Idade , Vertigem , Procedimentos Neurocirúrgicos
14.
Brain Sci ; 13(10)2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37891843

RESUMO

Titanium middle ear (ME) prostheses are widely used in surgical practice due to their acoustic properties. However, they present a significant drawback shared by all synthetic materials currently in use for ME reconstruction: they can be rejected by the organism of the host. In this study, we aim to review the current literature on titanium partial ossicular replacement prostheses (PORPs) and total ossicular replacement prostheses (TORPs) extrusion and dislocation. Eighty articles were analysed after a full article review based on the inclusion and exclusion criteria. The most common indication for reconstruction was chronic otitis media with cholesteatoma. The average extrusion or dislocation rate was 5.2%, ranging from 0 to 35%. The average improvements in the air-bone gap were 12.1 dB (1.6 dB to 25.1 dB) and 13.8 (-0.5 dB to 22.7 dB) for the PORP and TORP groups, respectively. The data reported on this topic are highly variable, demonstrating that functional outcomes are difficult to predict in clinical practice. We believe that the current limitations could be overcome with technological developments, including bioengineering research focused on promoting prosthesis adaptation to the ME environment.

15.
Children (Basel) ; 10(7)2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37508638

RESUMO

BACKGROUND: Congenital cytomegalovirus (cCMV) infection is the leading cause of non-hereditary sensorineural hearing loss in children. While about 10% of children reportedly display symptoms at birth, 85-90% of cCMV infection cases are asymptomatic. However, 10-15% of these asymptomatic infants may later develop hearing, visual, or neurodevelopmental impairments. This study aimed to evaluate the impact of cCMV infection on newborns' hearing function with a particular emphasis on progressive and late-onset cases. METHODS: This study is a retrospective chart analysis with longitudinal character and was conducted in two Italian centers: Center 1 (from 1 November 2007 to 31 December 2021) and Center 2 (from 1 January 2012 to 31 December 2021). Data collected included newborn hearing screening results, characterization of hearing loss (unilateral/bilateral, degree of impairment), and audiological follow-up. RESULTS: The cohort consisted of 103 children (42% males, 58% females). In total, 28 children presented with hearing impairment; 71.4% (20 out of 28) of the cases of hearing loss were severe/profound, with 35.7% of the cases due to unilateral hearing loss. Out of twenty-eight, six experienced progression of hearing loss and four had late-onset hearing loss. CONCLUSIONS: In the absence of universal cCMV screening, hearing screening at birth for cCMV remains a critical factor for early diagnosis. A significant percentage of children affected by cCMV with normal audiological evaluations at birth is easily lost to follow-up. Close collaboration between neonatologists, pediatricians, and audiological services is fundamental to ensure timely diagnosis and treatment of cCMV-related hearing loss.

16.
Acta Otorhinolaryngol Ital ; 43(Suppl. 1): S67-S75, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37698103

RESUMO

Objective: To establish the safety and effectiveness of subtotal petrosectomy with cochlear implantation in patients affected by chronic middle ear disorders to refractory to previous surgical treatments. Methods: A multicentre, retrospective study was conducted on patients affected by recalcitrant chronic middle ear disorders who underwent cochlear implantation in combination with subtotal petrosectomy. Patients' details were collected from databases of 11 Italian tertiary referral centres. Additionally, a review of the most updated literature was carried out. Results: 55 patients were included with a mean follow-up time of 44 months. Cholesteatoma was the most common middle ear recurrent pathology and 50.9% of patients had an open cavity. 80% of patients underwent a single stage surgery. One case of explantation for device failure was reported among the 7 patients with post-operative complications. Conclusions: Subtotal petrosectomy with cochlear implantation is a benchmark for management of patients with recalcitrant chronic middle ear disorders. A single stage procedure is the most recommended strategy. Optimal follow-up is still debated. Further studies are required to investigate the role of this surgery in paediatric patients.


Assuntos
Colesteatoma , Implante Coclear , Otite Média Supurativa , Humanos , Orelha Média/cirurgia , Estudos Retrospectivos
17.
Ear Hear ; 33(6): 721-30, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22785571

RESUMO

OBJECTIVES: Cochlear-implanted deaf children having additional disabilities may develop speech perception and language skills at a slower pace than their implanted peers without such disorders. Nevertheless, it has been shown that, even for these special cases, cochlear implantation (CI) provides benefits for a larger range of neuropsychological functions including social and relational skills. These benefits are frequently mentioned by parents, but rarely objectively measured by tests. This article presents a new evaluation tool aimed at assessing the global benefits offered by CI in these special cases. DESIGN: The new tool has been designed as a closed-format questionnaire, divided into five areas. It is based on observing the frequency of preselected behaviors in daily activities, which imply specific social, neuropsychological, and perceptual skills. The questionnaire has been presented to the parents of 50 deaf children with additional disabilities, before and at least 6 months after CI. RESULTS: The data show significant improvements in all investigated areas. However, not all skills improve in the same way, and only those skills related to language and communication correlate positively with time after implantation. The present article further discusses changes in skills for which parents have higher expectations, such as the preferred communication mode, speech intelligibility, and the ability to communicate on the telephone. CONCLUSIONS: The questionnaire has a simple-to-use format, and it has been proven to be sufficiently sensitive for the detection of changes in each examined area. Because the questionnaire is based on observed behaviors, it can be used even when other existing tests involve tasks that are too complex for these children.


Assuntos
Implante Coclear , Surdez/psicologia , Surdez/reabilitação , Crianças com Deficiência/psicologia , Crianças com Deficiência/reabilitação , Transtornos do Desenvolvimento da Linguagem/psicologia , Transtornos do Desenvolvimento da Linguagem/reabilitação , Distúrbios da Fala/reabilitação , Adolescente , Criança , Pré-Escolar , Comunicação , Comorbidade , Feminino , Humanos , Lactente , Masculino , Testes Neuropsicológicos/estatística & dados numéricos , Seleção de Pacientes , Psicometria , Qualidade de Vida/psicologia , Comportamento Social , Inteligibilidade da Fala , Inquéritos e Questionários
18.
Audiol Res ; 12(5): 485-492, 2022 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-36136856

RESUMO

BACKGROUND: The Carina system (Cochlear Ltd., Sydney, Australia) is a totally implantable device providing acoustic amplification in adult patients with moderate-to-severe sensorineural or mixed hearing loss. One of the main concerns about such a totally implantable device has been represented by the subcutaneous battery lifespan. The aim of this article is to report the analysis of battery performances in a series of Carina-implanted patients after a long follow up. METHODS: In this retrospective study, the technical data of a series of patients implanted with the Carina middle ear implant in our clinic have been analysed, extracting the data from the log of telemetric measures. RESULTS: The mean lifespan cutback was 0.43 h/years (from 0 to 0.71 h/year), with a strong negative significant correlation between the follow-up period and the percentage of battery residual lifespan. CONCLUSION: The lifespan of the Carina's battery seems consistent with the manufacturer statement of a pluri-decennial lifespan, avoiding the need of an early surgical substitution and providing a full day of use of the system even after up to 12 years from the implantation.

19.
J Int Adv Otol ; 18(4): 302-307, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35894526

RESUMO

BACKGROUND: Bone-anchored hearing aids represent a valid alternative for patients with conductive/mixed hearing loss who cannot use hear- ing aids. To date, these devices have given good audiological results, thanks to various fitting prescription programs (i.e., National Acoustic Laboratories and Desired Sensation Level). The aim of this study is to compare 2 types of fitting algorithms (National Acoustic Laboratories and Desired Sensation Level) implemented for bone-anchored hearing devices. METHODS: We retrospectively enrolled 10 patients followed at our operative unit, suffering from bilateral symmetrical mixed hearing loss and who underwent bone-anchored hearing aid implantation. All patients experienced each prescriptive procedure, National Acoustic Laboratories and Desired Sensation Level, for 7 months (on average), and they were subjected to audiological tests and questionnaires to evaluate the best program. RESULTS: National Acoustic Laboratories and Desired Sensation Level prescriptions yielded similar results. Desired Sensation Level allowed less amplification of the low frequencies than the National Acoustic Laboratories prescription, and these differences were the only statistically sig- nificant. Desired Sensation Level allowed better disyllabic word and sentence recognition scores only in quiet and not in noisy conditions. The subjective questionnaires showed similar results. At the end of the trial sessions, more patients (60%) definitively chose the Desired Sensation Level program for their device. These patients were those with a worse hearing threshold. CONCLUSION: The 2 prescriptive programs allowed similar results although patients with a worse threshold seem to prefer the DSL program. This is the first evaluation of the 2 prescriptive programs, National Acoustic Laboratories versus Desired Sensation Level, for bone conduction devices available in the literature. Further studies are needed to confirm this initial finding.


Assuntos
Surdez , Auxiliares de Audição , Perda Auditiva Condutiva-Neurossensorial Mista , Perda Auditiva Neurossensorial , Perda Auditiva , Percepção da Fala , Adulto , Limiar Auditivo , Perda Auditiva Condutiva , Perda Auditiva Condutiva-Neurossensorial Mista/terapia , Perda Auditiva Neurossensorial/reabilitação , Humanos , Estudos Retrospectivos
20.
Artigo em Inglês | MEDLINE | ID: mdl-34056891

RESUMO

BACKGROUND: The importance of neonatal screening for congenital cytomegalovirus infection (cCMV) is widely shared in the world scientific literature. However, currently, no programs for universal neonatal screening for cCMV have been reported in the literature, and only a few experiences of hearing targeted cCMV screening have been published. In the Tuscany Region, Italy, screening for cCMV has been mandatory since 2008 for each newborn that result "refer" at the Transient Evoked Otoacoustics Emissions (TEOAE) test, and in our university hospital since 2012, it has been extended to some categories at risk of cCMV. METHODS: We present the results of the protocol for cCMV screening adopted at our Institution since 2012. RESULTS: From 2012 to 2017, 1615 newborns underwent cCMV screening. Twenty-five cases were positive for cCMV, (1.54% of all the newborn screened for cCMV and 0.19% of infants submitted to newborn hearing screening). Nineteen of these children (76%) had normal hearing, while 6 (24%) had a hearing deficit of variable degree. 2/25 (8%) cases presented a progression of the hearing deficit in the first months of life and no children had a late onset or fluctuating hearing loss. CONCLUSIONS: Our findings show how cCMV screening in newborns that result refer at TEOAE allows the detection of many cases; but many are still missed. It would be, therefore, important to adopt a universal newborn cCMV screening program or a program extended to newborns at higher risk.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA