Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Health Phys ; 92(5 Suppl): S98-104, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17440329

RESUMO

Use of hair as a biological dosimeter of neutron exposure was proposed a few years ago. To date, the (32)S(n,p)(32)P reaction in hair with a threshold of 2.5 MeV is the best choice to determine the fast neutron dose using body activation. This information is essential with regards to the heterogeneity of the neutron transfer to the organism. This is a very important parameter for individual dose reconstruction from the surface to the deeper tissues. This evaluation is essential to the adapted management of irradiated victims by specialized medical staff. Comparison exercises between clinical biochemistry laboratories from French sites (the CEA and COGEMA) and from the IRSN were carried out to validate the measurement of (32)P activity in hair and to improve the techniques used to perform this examination. Hair was placed on a phantom and was irradiated at different doses in the SILENE reactor (Valduc, France). Different parameters were tested: variation of hair type, minimum weight of hair sample, hair wash before measurement, delivery period of results, and different irradiation configurations. The results obtained in these comparison exercises by the different laboratories showed an excellent correlation. This allowed the assessment of a dose-activity relationship and confirmed the feasibility and the interest of (32)P measurement in hair following fast neutron irradiation.


Assuntos
Cabelo , Nêutrons , Radiometria/métodos , Humanos , Laboratórios/normas , Reatores Nucleares
2.
Radiat Prot Dosimetry ; 127(1-4): 120-4, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17562647

RESUMO

The aim of this study is to model plutonium (Pu) excretion from the analysis of a well-documented Pu wound case involving repeated diethylene-triamine-penta-acetic acid (DTPA) perfusions up to 390 d and monitoring up to 3109 d. Three modelling approaches were simultaneously applied involving: (1) release of soluble Pu from the wound, estimated with the ICRP66 dissolution model, (2) systemic behaviour of Pu by using ICRP67 model, but also two new models recently reported and (3) additional 'Pu-DTPA' compartments which transfer Pu directly to urinary compartment from blood, interstitial fluids and liver. The best fit of simulations to biological data was obtained by using the new Leggett's systemic model and assuming the presence of three DTPA compartments. Calculations have shown that DTPA treatments have contributed to a 3-fold reduction of the effective dose. Thus, reduction of doses associated with the DTPA treatments can be estimated by modelling which is useful to improve the efficacy of a DTPA treatment schedule based on a diminution of risk.


Assuntos
Bioensaio/métodos , Ácido Pentético/administração & dosagem , Plutônio/farmacocinética , Plutônio/toxicidade , Lesões por Radiação/metabolismo , Lesões por Radiação/prevenção & controle , Radiometria/métodos , Ferimentos Penetrantes/metabolismo , Adulto , Carga Corporal (Radioterapia) , Quelantes/administração & dosagem , Simulação por Computador , Corpos Estranhos/complicações , Corpos Estranhos/dietoterapia , Corpos Estranhos/metabolismo , Humanos , Cinética , Masculino , Taxa de Depuração Metabólica , Modelos Biológicos , Lesões por Radiação/etiologia , Protetores contra Radiação/administração & dosagem , Eficiência Biológica Relativa , Resultado do Tratamento , Ferimentos Penetrantes/tratamento farmacológico , Ferimentos Penetrantes/etiologia
3.
Radiat Prot Dosimetry ; 127(1-4): 350-5, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17562646

RESUMO

A didactic software, MEthodes DOsimètriques de REférence (MEDOR), is being developed to provide help in the interpretation of biological data. Its main purpose is to evaluate the pertinence of the application of different models. This paper describes its first version that is focused on inhalation exposure to actinide aerosols. With this tool, sensitivity analysis on different parameters of the ICRP models can be easily done for aerosol deposition, in terms of activity and particle number, actinide biokinetics and doses. The user can analyse different inhalation cases showing either that dose per unit intake cannot be applied if the aerosol contains a low number of particles or that an inhibition of the late pulmonary clearance by particle transport can occur which contributes to a 3-4 fold increase in effective dose as compared with application of default parameters. This underlines the need to estimate systematically the number of deposited particles, as well as to do chest monitoring as long as possible.


Assuntos
Elementos da Série Actinoide/análise , Elementos da Série Actinoide/farmacocinética , Algoritmos , Bioensaio/métodos , Radiometria/métodos , Software , Carga Corporal (Radioterapia) , Humanos , Doses de Radiação , Eficiência Biológica Relativa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA