1.
J Am Coll Cardiol ; 24(1): 247-53, 1994 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8006273

RESUMO

OBJECTIVES: This study was designed to assess the feasibility of calculating left ventricular volumes using intracardiac ultrasound. BACKGROUND: Previous studies have validated transthoracic echocardiographic determinations of left ventricular volumes and have indicated the superiority of Simpson rule reconstruction algorithms. The feasibility of imaging the left ventricle with intracardiac ultrasound has also been demonstrated. METHODS: The determination of left ventricular volumes with Simpson rule reconstruction of intracardiac ultrasound images was evaluated in two phases. In vitro validation was performed in 29 animal hearts preserved in either a nondistended or distended state. Latex cast volumes were the reference standard. In vivo studies used 14 pigs, and compared intracardiac ultrasound volumes and ejection fraction with single-plane contrast angiographic values. A 12.5-MHz device was used to record short-axis images at 0.5-cm intervals. These were used to reconstruct the ventricle as a stack of cylindric elements using all imaged levels as well as sections recorded every 1 and 2 cm and at a single midventricular level. RESULTS: In the in vitro hearts, when all recorded sections were used, there was excellent agreement between intracardiac ultrasound and latex cast volumes (intracardiac ultrasound volume = 0.89 latex cast volume + 2.22, r = 0.95; intracardiac ultrasound volume = 0.97 latex cast volume + 0.91, r = 0.99) for nondistended and distended hearts, respectively. In vivo, there was again close correspondence between ultrasound and angiographic volumes (intracardiac ultrasound volume = 1.04 angiographic volume - 3.6, r = 0.91). The relation between intracardiac ultrasound and angiographic ejection fraction was fair (intracardiac ultrasound ejection fraction = 1.00 angiographic ejection fraction + 6.85, r = 0.69). Excellent correlations for the volumes were maintained as the number of cross sections was reduced to those recorded every 1 and 2 cm (r = 0.87 to 0.99). With a single midventricular site more variable but generally good correlations were obtained (r = 0.77 to 0.99). CONCLUSIONS: The application of Simpson rule reconstruction to short-axis images of the left ventricle obtained with intracardiac ultrasound provides accurate determination of left ventricular volumes in animal hearts. This technique may prove useful in the analysis of left ventricular structure and function.


Assuntos
Ecocardiografia/métodos , Algoritmos , Animais , Bovinos , Ecocardiografia/instrumentação , Ecocardiografia/estatística & dados numéricos , Estudos de Viabilidade , Ventrículos do Coração/diagnóstico por imagem , Técnicas In Vitro , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Suínos
2.
J Am Coll Cardiol ; 23(7): 1570-7, 1994 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8195516

RESUMO

OBJECTIVES: This study was designed to assess the feasibility of using hydrogel-coated balloons to deliver biologically active agents to the blood vessel wall. BACKGROUND: The local intramural delivery of therapeutic agents during balloon angioplasty has been proposed as an adjunctive technique for preventing early intracoronary thrombosis and late restenosis. METHODS: To assess the efficacy of delivery and depth of penetration in vitro, local delivery of horseradish peroxidase was performed in 40 porcine peripheral arteries, and delivery of fluoresceinated heparin was performed in 20 porcine peripheral arteries and 7 human atheromatous arteries. To determine the persistence of these agents in the vessel wall in vivo, horseradish peroxidase was delivered to 18 porcine peripheral arteries that were harvested at intervals of 45 min to 48 h. Fluoresceinated heparin was delivered to 22 porcine peripheral arteries, 14 with the use of a protective sleeve, harvested at intervals of 30 s to 24 h. RESULTS: In vitro agent delivery was successful in all specimens. The depth of penetration of horseradish peroxidase was directly related to both balloon pressure (p < 0.04) and duration of inflation (p < 0.01). In vivo peroxidase staining was evident at 45 and 90 min but not thereafter. With the use of a protective sleeve, heparin was present in all arteries harvested at 30 s, with marked dissipation at 1 and 24 h. Without a sleeve, no fluorescein staining was detected in any artery. With both agents, delivery occurred consistently over broad regions of the vessel wall that were free of architectural disruption. CONCLUSIONS: Hydrogel-coated balloons can deliver biologically active agents to the vessel wall without gross tissue disruption and may provide an atraumatic method for the local delivery of therapeutic agents during balloon angioplasty.


Assuntos
Angioplastia com Balão/instrumentação , Sistemas de Liberação de Medicamentos , Polietilenoglicóis , Animais , Difusão , Estudos de Viabilidade , Feminino , Heparina/administração & dosagem , Peroxidase do Rábano Silvestre/administração & dosagem , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Técnicas In Vitro , Masculino , Pressão , Suínos
3.
J Am Coll Cardiol ; 32(7): 1996-2002, 1998 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9857884

RESUMO

OBJECTIVES: The purpose of this study was to compare the outcome of primary percutaneous transluminal coronary angioplasty for acute myocardial infarction (MI) when performed with or without the platelet glycoprotein IIb/IIIa antibody, abciximab. BACKGROUND: Abciximab improves the outcome of angioplasty but the effect of abciximab in primary angioplasty has not been investigated. METHODS: Data were collected from a computerized database. Follow-up was by telephone or review of outpatient or hospital readmission records. RESULTS: A total of 182 consecutive patients were included; 103 received abciximab and 79 did not. The procedural success rate was 95% in the two groups. At 30-day follow-up, the composite event rate of unstable angina, reinfarction, target vessel revascularization and death from all causes was 13.5% in the group of patients who did not receive abciximab, 4% (p < 0.05) in the abciximab group and 2.4% (p < 0.05) in the subgroup of patients (n = 87) who completed the 12-h abciximab infusion. At the end of follow-up (mean 7+/-4 months), the composite event rate was 32.4%, 17% (p < 0.05) and 13.1% (p < 0.01) in these three categories respectively. Abciximab bolus followed by a 12-h infusion was an independent predictor of event-free survival, in a Cox proportional hazards model (relative risk 0.49; 95% confidence interval 0.24 to 0.99; p < 0.05). CONCLUSIONS: Abciximab given at the time of primary angioplasty may improve the short- and medium-term outcome of patients with acute MI, especially when a 12-h infusion is completed.


Assuntos
Angioplastia Coronária com Balão , Anticorpos Monoclonais/uso terapêutico , Fragmentos Fab das Imunoglobulinas/uso terapêutico , Infarto do Miocárdio/terapia , Inibidores da Agregação Plaquetária/uso terapêutico , Abciximab , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/mortalidade , Modelos de Riscos Proporcionais , Análise de Sobrevida , Resultado do Tratamento
4.
J Am Coll Cardiol ; 21(6): 1512-21, 1993 May.
Artigo em Inglês | MEDLINE | ID: mdl-8473664

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the efficacy of radiofrequency-powered thermal balloon angioplasty in an in vivo porcine model. BACKGROUND: Various modes of thermal energy used adjunctively during balloon angioplasty have demonstrated the potential to enhance the results of acute lumen dilation. METHODS: In normal pigs, 75 peripheral arteries were dilated with a newly designed, radiofrequency-powered, thermal angioplasty balloon. All inflations were performed at 2-atm pressure for 85 s. Dilations were performed either with (hot) or without (cold) the application of heat. Lumen dimensions and vessel morphology were assessed with intravascular ultrasonography. At the end of each study, dilated arterial segments were harvested for histologic examination. RESULTS: Single cold balloon inflations resulted in a 12.7% increase in arterial cross-sectional area whereas single hot inflations resulted in a 22.9% increase (p < 0.03). Similarly, when multiple cold inflations were compared with multiple hot inflations, two, three and four sequential hot inflations resulted in a significantly greater increase in cross-sectional area than an equivalent number of cold inflations (p < 0.03). Histologic examination demonstrated a temperature-dependent effect on the depth of medial necrosis and extent of arterial wall thinning (p < 0.001) as well as evidence for uniform alteration of elastic tissue fibers at temperatures of > or = 60 degrees C (p < 0.03). CONCLUSIONS: Low pressure radiofrequency thermal balloon angioplasty results in a greater increase in cross-sectional area in porcine peripheral arteries than does nonheated conventional balloon angioplasty. The pathologic basis for this enhanced dilation may be a temperature-dependent effect on medial necrosis, thinning of the arterial wall or alteration of vascular elastic fibers, alone or in combination.


Assuntos
Angioplastia com Balão/métodos , Doenças Vasculares Periféricas/terapia , Angioplastia com Balão/efeitos adversos , Animais , Artérias Carótidas/patologia , Eletrocoagulação , Estudos de Avaliação como Assunto , Feminino , Artéria Femoral/patologia , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/patologia , Masculino , Ondas de Rádio , Suínos , Temperatura , Ultrassonografia
5.
Am J Cardiol ; 85(6): 675-9, 2000 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-12000039

RESUMO

Women presenting with acute myocardial infarction (AMI) have a higher mortality with conventional medical and thrombolytic therapy when compared with men. The outcome after primary percutaneous transluminal mechanical revascularization has not yet been fully investigated. This study was performed to compare the characteristics and the short- and medium-term outcomes of women and men with AMI treated with primary percutaneous revascularization. A total of 182 consecutive patients (62 women and 120 men) were included. Baseline clinical characteristics were similar except that women were older than men, presented more often in cardiogenic shock, and had smaller reference vessel diameters. Stents and abciximab were used equally, but abciximab was stopped more often in women before completion of the 12-hour infusion because of higher bleeding rates. Acute procedural success rates were similar (92% and 97%) but mortality was much higher in women, both at 30-day follow-up (100% vs 0.9%; p <0.05) and during a mean follow-up of 6.9 +/- 4.1 months (15% vs 4.4%; p <0.05). Women also experienced more unfavorable cardiovascular events (recurrent unstable angina or AMI, target vessel revascularization) than men. However, after control for baseline clinical differences in a multivariate analysis, gender was not an independent predictor of survival, whereas age, cardiogenic shock, and completion of a 12-hour abciximab infusion were.


Assuntos
Angioplastia Coronária com Balão , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/terapia , Abciximab , Idoso , Anticorpos Monoclonais/uso terapêutico , Transfusão de Sangue/estatística & dados numéricos , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Fragmentos Fab das Imunoglobulinas/uso terapêutico , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Inibidores da Agregação Plaquetária/uso terapêutico , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Fatores de Risco , Fatores Sexuais , Choque Cardiogênico/epidemiologia , Fatores de Tempo , Resultado do Tratamento
6.
Am J Cardiol ; 80(11): 1476-8, 1997 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-9399726

RESUMO

C-reactive protein (CRP) levels increased more than sixfold above baseline when measured 48 hours after elective percutaneous transluminal coronary angioplasty (PTCA) in patients without underlying inflammatory conditions and did not change significantly in controls undergoing coronary angiography. Only 3 of the 42 PTCA patients had clinical restenosis and underwent target vessel revascularization during the 6-month follow-up, but 2 of the 3 had very high CRP levels 48 hours after the procedure.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Proteína C-Reativa/metabolismo , Doença das Coronárias/imunologia , Ativação Linfocitária , Ativação de Neutrófilo , Ativação Plaquetária , Biomarcadores , Adesão Celular , Angiografia Coronária , Doença das Coronárias/sangue , Doença das Coronárias/terapia , Seguimentos , Humanos , Pessoa de Meia-Idade , Recidiva
7.
J Invasive Cardiol ; 11(8): 463-70, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10745576

RESUMO

The efficacy of local drug delivery in the treatment of coronary artery disease is limited by the relatively low delivery efficiency of the available devices. A unique local drug delivery device, the Infiltrator catheter (InterVentional Technologies, Inc.), has been designed specifically to enhance efficiency by injecting drugs directly into the arterial wall through microports mounted on the balloon surface. The purpose of this study was to assess the efficiency of delivery of this device in the porcine coronary model and to compare it to a previously validated device, the hydrogel balloon (Boston Scientific, Maple Grove, Minnesota). Studies were also performed to assess the pattern of intramural heparin deposition following delivery with the Infiltrator catheter and to assess the effect of the microports on vascular integrity. The efficiency of delivery was significantly greater with the Infiltrator catheter than with the hydrogel balloon (4.5% vs. 0.08%; p = 0.02). Similarly, the absolute amount of intramurally deposited heparin was greater with the Infiltrator (111.3 +/- 38.5 units vs. 2.4 +/- 0.85 units; p = 0.02) despite the fact that more heparin was delivered with the hydrogel catheter. Histologic studies revealed characteristic discrete puncture channels in the vessel wall due to penetration of the microports. Other than this histologic finding, there was no significant difference in the extent of architectural disruption between the Infiltrator and conventional balloon inflations. Fluorescein-labeled heparin studies revealed heparin to be diffusely distributed throughout the vessel wall immediately following delivery with the Infiltrator. We conclude that the Infiltrator catheterOs unique mechanism of delivery improves the efficiency of local drug delivery without excessive vessel wall trauma.


Assuntos
Anticoagulantes/administração & dosagem , Cateterismo , Vasos Coronários , Sistemas de Liberação de Medicamentos , Heparina/administração & dosagem , Animais , Anticoagulantes/farmacocinética , Vasos Coronários/metabolismo , Desenho de Equipamento , Heparina/farmacocinética , Suínos
9.
Catheter Cardiovasc Interv ; 53(2): 163-73, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11387599

RESUMO

The purpose of this study was to assess the efficacy and safety of using a percutaneous suture device to close femoral arteriotomies following invasive cardiac procedures. All patients presenting for invasive cardiac procedures performed from the femoral artery were considered for suture closure. Patients were carefully assessed for access site complications, oozing, and the impact of suture closure on the safety of early ambulation. Clinical follow-up at 3-6 months was performed to assess for late complications. Femoral artery suture closures were performed in 1,200 consecutive cases in 1,097 patients. In 12.8% of cases, the patients ambulated within 1 hr. The success rate was 91.2% and the complication rate was 3.4%. Complications included the development of a hematoma (2.1%), the need for vascular surgery (0.6%), retroperitoneal hemorrhage (0.3%), blood transfusion (0.7%), local infection (0.5%), and pseudoaneurysm formation (0.1%). Factors found to be independently predictive of procedural failure were an age > 70 years, an ACT > 300 sec, left femoral artery access, and the performance of primary angioplasty. Follow-up at 3-6 months revealed no major hemorrhagic complications. We conclude that percutaneous suture closure effectively achieves femoral artery hemostasis in patients undergoing invasive cardiac procedures. The technique permits early ambulation and is associated with a relatively low incidence of complication.


Assuntos
Artéria Femoral/cirurgia , Cardiopatias/terapia , Técnicas de Sutura/instrumentação , Idoso , Falso Aneurisma/etiologia , Transfusão de Sangue , Índice de Massa Corporal , Deambulação Precoce , Determinação de Ponto Final , Análise de Falha de Equipamento , Segurança de Equipamentos , Feminino , Seguimentos , Cardiopatias/complicações , Hematoma/etiologia , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Infecção da Ferida Cirúrgica/etiologia , Falha de Tratamento , Resultado do Tratamento
10.
Cathet Cardiovasc Diagn ; 41(3): 275-86, 1997 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9213026

RESUMO

The purpose of this study was to assess the efficacy of local heparin delivery to balloon angioplasty sites in an in vivo porcine model by using a newly designed angiotherapy catheter that allows for prolonged drug infusion while maintaining distal arterial perfusion. Protocols were designed to assess the safety of intracoronary drug delivery, the effect of infusion time and drug concentration on intramural heparin deposition, the distribution of heparin within the arterial wall, the histologic effects of local heparin delivery, the wash-out of intramurally deposited heparin, and the effect of heparin delivery on early platelet deposition following balloon injury in peripheral and coronary vessels. Local intracoronary delivery of heparin was well tolerated in all animals. Between 0.04 and 0.08% of infused heparin was intramurally deposited at the time of drug delivery, with longer infusion durations and higher concentrations of heparin resulting in greater intramural deposition. Autoradiography demonstrated homogenous distribution of heparin throughout the intima, media, and adventitia, with localization in the nuclei, cytoplasm, and extracellular space. Histologic analysis demonstrated no additional vessel trauma from local drug delivery beyond that seen with conventional angioplasty. Wash-out studies demonstrated a biexponential disappearance of intramurally deposited drug, with rapid release of heparin over the first 60 min and persistence of small amounts of drug for at least 7 d. Locally delivered heparin significantly attenuated the deposition of platelets in peripheral vessels, although a similar decrease in platelet deposition in the coronary arteries was not statistically significant. Local delivery of heparin directly to coronary angioplasty sites is possible with the use of a new angiotherapy catheter. Wash-out of heparin from the arterial wall is initially rapid, although drug is detectable for up to 1 wk following delivery. In porcine peripheral arteries, use of this technique significantly decreases early platelet deposition following balloon injury.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Anticoagulantes/administração & dosagem , Vasos Coronários/efeitos dos fármacos , Sistemas de Liberação de Medicamentos/instrumentação , Heparina/administração & dosagem , Músculo Liso Vascular/efeitos dos fármacos , Agregação Plaquetária/efeitos dos fármacos , Animais , Anticoagulantes/farmacocinética , Autorradiografia , Vasos Coronários/patologia , Relação Dose-Resposta a Droga , Desenho de Equipamento , Heparina/farmacocinética , Músculo Liso Vascular/patologia , Suínos , Resultado do Tratamento
11.
Cathet Cardiovasc Diagn ; 41(3): 315-23, 1997 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9213031

RESUMO

Drug delivery by iontophoresis involves the application of an electric field to move selectively charged drug molecules across biological membranes. The purpose of this study was to assess the efficacy of intravascular iontophoresis in the local delivery of heparin to balloon angioplasty sites by using a recently designed iontophoretic catheter. In vivo heparin iontophoresis was assessed in 33 rats and 21 pigs in four protocols designed to measure the technical determinants of intramural drug deposition, the pharmacokinetics and localization of coronary delivery, and the effect of this technique on platelet deposition following balloon injury. First, iontophoresis of 3H-heparin into the aorta of 33 rats was performed to determine the effects of iontophoretic current, iontophoretic membrane balloon initiation pressure, iontophoresis time, and heparin concentration on intramural drug deposition. Second, iontophoresis of 3H-heparin was performed in 16 porcine coronary arteries to quantitate immediate drug delivery and subsequent wash-out over 24 h. Third, iontophoresis of fluorescent heparin was performed in 8 porcine coronary arteries to define intramural localization of locally delivered drug. Fourth, 111In-labeled platelet deposition was measured 1 h following balloon angioplasty and local iontophoretic heparin delivery in 16 porcine carotid and iliac vessels. Contralateral control vessels that were dilated with the same size balloon and treated with iontophoresis of saline served as controls. Rat aortic studies demonstrated that iontophoresis resulted in 13 times more intramural heparin deposition than passive delivery (passive: 0.3 +/- 0.4 microgram, iontophoresis: 4.6 +/- 1.6 micrograms, P < 0.0004). Iontophoretic membrane balloon inflation pressure had no significant effect on intramural drug deposition, but longer iontophoresis times and higher heparin concentrations resulted in higher levels of intramural heparin (P < 0.05). Porcine coronary studies demonstrated successful intramural deposition of heparin in all arteries without adverse electrical or hemodynamic sequelae, with persistence of the drug for at least 24 h. Localization studies demonstrated immediate deposition of fluorescent heparin in the intima and internal elastic lamina, with subsequent rapid diffusion of the drug into the media. Porcine platelet studies demonstrated that heparin iontophoresis decreased platelet deposition following balloon injury by approximately 66% compared with saline-treated control vessels (heparin-treated: 1.46 +/- 2.51 x 10(8), control: 4.27 +/- 7.02 x 10(8), P = 0.001). This study has demonstrated that local intramural heparin delivery is feasible with an intravascular iontophoretic catheter. Following intracoronary heparin iontophoresis in the porcine model, intramural drug is detected for at least 24 h. Local delivery of heparin with this technique significantly decreases early platelet deposition following balloon injury in peripheral porcine arteries.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Angioplastia com Balão/instrumentação , Anticoagulantes/administração & dosagem , Sistemas de Liberação de Medicamentos/instrumentação , Heparina/administração & dosagem , Iontoforese/instrumentação , Músculo Liso Vascular/efeitos dos fármacos , Animais , Anticoagulantes/farmacocinética , Aorta/efeitos dos fármacos , Aorta/lesões , Aorta/patologia , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/lesões , Vasos Coronários/patologia , Relação Dose-Resposta a Droga , Tecido Elástico/efeitos dos fármacos , Tecido Elástico/lesões , Tecido Elástico/patologia , Desenho de Equipamento , Heparina/farmacocinética , Masculino , Músculo Liso Vascular/lesões , Músculo Liso Vascular/patologia , Agregação Plaquetária/efeitos dos fármacos , Ratos , Ratos Sprague-Dawley , Suínos , Túnica Íntima/efeitos dos fármacos , Túnica Íntima/lesões , Túnica Íntima/patologia , Túnica Média/efeitos dos fármacos , Túnica Média/lesões , Túnica Média/patologia
12.
Cathet Cardiovasc Diagn ; 42(3): 348-55, 1997 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9367120

RESUMO

Nineteen pigs were studied in order to assess the effect of low grade, radiofrequency-powered, thermal balloon angioplasty on the vasoconstrictor response of peripheral arteries. A mechanical stimulus was used to induce vasospasm. Thermal angioplasty reduced the extent of inducible vasospasm from 79% to 6% compared to nonthermal control inflations, which reduced the vasoconstrictor response from 75% to 60% (P < 0.001). Histologic studies demonstrated that the extent of myocyte necrosis was significantly greater in the thermally treated arteries than in the control vessels (P < 0.01). Thermal balloon angioplasty at 60 degrees C significantly attenuates peripheral arterial vasospasm induced by mechanical trauma in the porcine model. This paralytic effect may be related to the loss of myocytes secondary to thermal necrosis.


Assuntos
Angioplastia com Balão , Vasoespasmo Coronário/fisiopatologia , Temperatura Alta , Vasoconstrição , Animais , Angiografia Coronária , Vasoespasmo Coronário/patologia , Vasos Coronários/patologia , Feminino , Masculino , Miocárdio/citologia , Miocárdio/patologia , Necrose , Suínos
13.
Pacing Clin Electrophysiol ; 18(8): 1518-30, 1995 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-7479173

RESUMO

Radiofrequency catheter ablation of left-sided accessory pathways is technically demanding and usually requires left heart catheterization. The feasibility of creating lesions from within the coronary sinus of sufficient size to ablate accessory pathways in humans using a thermal balloon catheter was studied in 20 dogs. In group 1 (n = 14), 17 thermal inflations were performed in 12 dogs at either 70 degrees, 80 degrees, or 90 degrees C each for 30 or 60 seconds (in 2 dogs two non-thermal control inflations were performed). Animals were sacrificed 6.3 +/- 1.6 days later. In group 2 (n = 6), seven thermal inflations were performed at 90 degrees C each for 180, 300, or 360 seconds. Group 2 animals received antiplatelet and anticoagulant therapy for 1 week and were sacrificed at 13 +/- 10.7 days. In both groups, hemodynamic, angiographic, and electrocardiographic studies were performed at baseline, 1 hour after inflation, and prior to sacrifice. All dogs remained clinically stable throughout the procedure and no complications were attributed to the effect of thermal inflation. Thermal lesions measured 14.4 +/- 4.4 mm in length and extended from the coronary sinus intima to a mean depth of 2.9 +/- 1.2 mm (range 1.4-6.5 mm). Group 2 lesions were significantly deeper than group 1 lesions (P = 0.03). Of the 24 thermal lesions created, atrial necrosis was present in 23 and ventricular necrosis in 11. In all lesions there was some degree of either atrial necrosis, ventricular necrosis, or both. A variable degree of coronary sinus thrombus was present in 18 dogs without clinical sequelae. It is concluded that radiofrequency balloon heating via the coronary sinus can create thermal lesions in the atrioventricular sulcus of dogs that may be of sufficient size to ablate accessory left-sided pathways in humans.


Assuntos
Nó Atrioventricular/cirurgia , Ablação por Cateter/métodos , Vasos Coronários , Animais , Anticoagulantes/uso terapêutico , Nó Atrioventricular/patologia , Ablação por Cateter/instrumentação , Cateterismo/instrumentação , Angiografia Coronária , Trombose Coronária/patologia , Vasos Coronários/patologia , Modelos Animais de Doenças , Cães , Eletrocardiografia , Estudos de Viabilidade , Átrios do Coração/patologia , Ventrículos do Coração/patologia , Hemodinâmica , Temperatura Alta/uso terapêutico , Humanos , Necrose , Inibidores da Agregação Plaquetária/uso terapêutico , Túnica Íntima/patologia
14.
Cathet Cardiovasc Diagn ; 37(4): 453-4, 1996 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8721704

RESUMO

Maintaining the position of a guidewire across coronary artery lesions during angioplasty is important to permit rapid and reliable access. This article describes a technique which enables a guide catheter to be replaced while maintaining coronary guidewire position by using an additional, larger guidewire for support to prevent dislodgment of the coronary guidewire.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateterismo Cardíaco/instrumentação , Doença das Coronárias/terapia , Angiografia Coronária/instrumentação , Desenho de Equipamento , Humanos
15.
Am Heart J ; 126(4): 969-78, 1993 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8213457

RESUMO

The purpose of this study was to assess the safety and histologic effects of radiofrequency thermal balloon angioplasty in the coronary vasculature of normal pigs. Radiofrequency thermal balloon angioplasty was performed in 30 coronary arteries of 16 nonatherosclerotic pigs. Heated inflations were performed at either 50 degrees, 60 degrees, or 70 degrees C for 30 or 60 seconds, and were compared with five nonheated inflations in five additional arteries. All balloon inflations were performed at 2 atm pressure with a balloon/vessel diameter ratio of 1.2 to 1. Heart rate, arterial pressure, and left ventricular pressure were monitored continuously for each animal. A 12-lead ECG, coronary angiography, and two-dimensional transthoracic echocardiography were performed before and 1 hour after each balloon inflation. Each animal was subsequently put to death for postmortem cardiac examination. Heated inflations were well tolerated in 28 of the 30 arteries without significant adverse effects. During one inflation, ventricular fibrillation occurred because of prolonged ischemia from an occlusive guiding catheter. In another artery, a heated inflation resulted in a dissection with a transient decrease in distal coronary flow. Histologic examination revealed a significant increase in wall thinning and elastic fiber straightening with heating at 70 degrees C for both 30 and 60 seconds, and a significant increase in intracoronary thrombus with heating at 70 degrees C for 60 seconds. Depth of periarterial myocardial heat necrosis paralleled the increase in temperature, with an average depth of 166 microns at 50 degrees C, 312 microns at 60 degrees C, and 1031 microns at 70 degrees C. In vivo, radiofrequency coronary angioplasty can be performed relatively safely without significant electrical, hemodynamic, or ischemic changes beyond those seen with conventional nonthermal angioplasty. The extent of heat-induced vessel wall thinning, elastic tissue straightening, intracoronary thrombus formation, and periarterial myocardial necrosis are all related to balloon temperature or duration of heating.


Assuntos
Angioplastia Coronária com Balão/métodos , Vasos Coronários/patologia , Angioplastia Coronária com Balão/instrumentação , Animais , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Ecocardiografia , Eletrocardiografia , Estudos de Avaliação como Assunto , Feminino , Masculino , Segurança , Suínos , Temperatura
16.
Am Heart J ; 128(1): 21-7, 1994 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8017280

RESUMO

Radiofrequency-powered, thermal balloon angioplasty is a new technique that enhances luminal dilatation with less dissection than conventional angioplasty. The purpose of this study was to assess the effect of radiofrequency heating of balloon fluid on the pressure-volume mechanics of in vitro balloon angioplasty and to determine the histologic basis for thermal-induced compliance changes. In vitro, radiofrequency-powered, thermal balloon angioplasty was performed on 46 paired iliac segments freshly harvested from 23 nonatherosclerotic pigs. Balloon inflations at 60 degrees C were compared to room temperature inflations in paired arterial segments. Intraballoon pressure and volume were recorded during each inflation as volume infusion increased pressure over a 0 to 10 atm range. Pressure-volume compliance curves were plotted for all dilatations. Six segments were stained to assess the histologic abnormalities associated with thermal compliance changes. Radiofrequency heating acutely shifted the pressure-volume curves rightward in 20 of 23 iliac segments compared to nonheated controls. This increase in compliance persisted after heating and exceeded the maximum compliance shift caused by multiple nonheated inflations in a subset of arterial segments. Histologically, heated segments showed increased thinning and compression of the arterial wall, increased medial cell necrosis and altered elastic tissue fibers compared to nonheated specimens. In conclusion, radiofrequency heating of intraballoon fluid to 60 degrees C acutely increases vascular compliance during in vitro balloon angioplasty of nonatherosclerotic iliac arteries. The increased compliance persists after heating and can be greater than the compliance shifts induced by multiple conventional dilatations. Arterial wall thinning and irreversible alteration of elastic tissue fibers probably account for thermal compliance changes.


Assuntos
Angioplastia com Balão/métodos , Aorta/fisiologia , Artéria Ilíaca/fisiologia , Angioplastia com Balão/instrumentação , Animais , Aorta/anatomia & histologia , Fenômenos Biomecânicos , Dilatação , Tecido Elástico/patologia , Elasticidade , Desenho de Equipamento , Temperatura Alta , Artéria Ilíaca/anatomia & histologia , Polietilenotereftalatos , Pressão , Análise de Regressão , Propriedades de Superfície , Suínos , Termodinâmica , Túnica Íntima/patologia , Túnica Média/patologia
17.
Cathet Cardiovasc Diagn ; 41(3): 246-53, 1997 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9213022

RESUMO

Conventional balloon angioplasty in the presence of intracoronary thrombus is associated with an elevated risk for acute myocardial infarction, emergency bypass surgery, and death. The purpose of this study was to assess the safety and efficacy of a new technique to treat thrombus-containing stenoses consisting of the local delivery of urokinase directly to the site of intraluminal clot with hydrogel-coated balloons. Ninety-five patients with angiographically apparent intracoronary thrombus were treated with urokinase-coated hydrogel balloons either prior to (n = 74) or following (n = 21) conventional balloon angioplasty. Clinical diagnoses for the study group included acute myocardial infarction in 50 patients, postinfarction angina in 23 patients, and unstable angina in 22 patients. All hydrogel balloons were initially coated with urokinase by immersing the inflated balloon in a concentrated Abbokinase solution (50,000 units/ml) for 60 s. All patients were subsequently treated with drug-coated balloons using a balloon:artery ratio of 1:1, a mean of 2.2 +/- 1.2 inflations, and a mean total inflation time of 7.5 +/- 4.9 min. Use of urokinase-coated balloons resulted in angiographic disappearance of intracoronary thrombus in 78 patients, improvement in 14, and no change in the remaining 3 patients. Following hydrogel balloon use for the entire 95 patients, TIMI flow increased from 1.4 +/- 1.2 to 2.9 +/- 0.4, minimal lumen diameter increased from 0.4 +/- 0.4 to 2.0 +/- 0.6 mm, and thrombus score decreased from 2.0 +/- 0.9 to 0.2 +/- 0.6 (all P < 0.01). Procedural and early in-hospital complications were noted in 7 of the 95 patients (7.4%) and included abrupt closure in 3 patients, distal embolization in 1 patient, no reflow in 1 patient, sidebranch occlusion in 1 patient, and late closure in 1 patient. Two of the 3 patients with abrupt closure and the single patient with late closure required intracoronary stenting to maintain vessel patency. Two of these 7 patients sustained small myocardial infarctions, although no patient required emergency bypass surgery or experienced a procedural death. Late clinical follow-up (mean = 8.3 +/- 6.6 months; range = 2 wk to 29 mo) demonstrated adverse recurrent events in 29 of the 95 patients (30.5%), including death (n = 5), myocardial infarction (n = 2), and recurrence of angina (n = 22). The results of this study suggest that intracoronary thrombolysis can be safely and rapidly achieved by using limited quantities of urokinase delivered directly to the site of intraluminal clot with hydrogel balloons. Use of this technique may result in improved acute outcomes in comparison with conventional techniques currently being used to treat thrombus-containing stenoses.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Trombose Coronária/tratamento farmacológico , Sistemas de Liberação de Medicamentos/instrumentação , Fibrinolíticos/administração & dosagem , Polietilenoglicóis , Terapia Trombolítica/instrumentação , Ativador de Plasminogênio Tipo Uroquinase/administração & dosagem , Adulto , Idoso , Angina Pectoris/diagnóstico por imagem , Angina Pectoris/tratamento farmacológico , Angina Pectoris/mortalidade , Angina Instável/diagnóstico por imagem , Angina Instável/tratamento farmacológico , Angina Instável/mortalidade , Angiografia Coronária/efeitos dos fármacos , Circulação Coronária/efeitos dos fármacos , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/mortalidade , Desenho de Equipamento , Feminino , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/mortalidade , Recidiva , Propriedades de Superfície , Taxa de Sobrevida
18.
Cathet Cardiovasc Diagn ; 41(3): 261-7, 1997 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-9213024

RESUMO

Percutaneous treatment of thrombotic stenoses or total occlusions in aged saphenous vein bypass grafts is associated with a significant incidence of complications primarily related to distal embolization. The purpose of this study was to assess the efficacy of local urokinase delivery with the Dispatch catheter prior to balloon angioplasty and/or intragraft stent placement as a new technique of vein graft revascularization. Local urokinase delivery with the Dispatch catheter was performed in 15 saphenous vein grafts (mean age = 11.7 +/- 2.5 yr) in 13 patients with unstable or postinfarction angina. The target lesion was a total occlusion in 5 of the procedures and a severe vein graft stenosis in the remaining 10. In all cases, urokinase was administered directly to the site of the stenosis/occlusion via the Dispatch catheter at 0.5 cc/min and at a concentration of 30,000 units/cc. The mean urokinase infusion time for the 15 procedures was 33 +/- 10 min (range = 10-60 min) and the mean urokinase dose was 495,000 +/- 158,000 units (range = 150,000-900,000 units). Following Dispatch therapy, mean minimal lumen diameter increased from 0.34 +/- 0.32 to 1.81 +/- 0.78 mm (P < 0.01), mean TIMI flow increased from 1.9 +/- 1.4 to 2.8 +/- 0.8 (P < 0.06), and mean thrombus score was reduced from 2.3 +/- 0.6 to 0.3 +/- 0.8 (P < 0.01). Mild no reflow was noted in two cases, although no patient demonstrated angiographic evidence of gross distal embolization. One of the patients with no reflow also demonstrated a small increase in cardiac enzymes. Subsequent balloon angioplasty/stent placement was successful in 14 of the 15 procedures (93% success rate). This preliminary report suggests that pretreatment of thrombotic saphenous vein graft stenoses with local urokinase delivery via the Dispatch catheter may decrease intragraft thrombus and possibly decrease the incidence of vascular complications associated with percutaneous intervention. This technique may allow for recanalization of totally occluded vein grafts with large clot burdens by using significantly less urokinase and shorter drug administration times than conventional infusion protocols.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Ponte de Artéria Coronária , Doença das Coronárias/cirurgia , Sistemas de Liberação de Medicamentos/instrumentação , Fibrinolíticos/administração & dosagem , Oclusão de Enxerto Vascular/tratamento farmacológico , Terapia Trombolítica/instrumentação , Ativador de Plasminogênio Tipo Uroquinase/administração & dosagem , Veias/transplante , Adulto , Idoso , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Desenho de Equipamento , Feminino , Oclusão de Enxerto Vascular/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Retratamento , Stents , Resultado do Tratamento
19.
Am Heart J ; 129(6): 1114-21, 1995 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-7754941

RESUMO

Autopsy studies have suggested that infarction of > 35% of the myocardium is associated with cardiogenic shock. However, the relation between the extent of myocardial dysfunction and hemodynamic status has not been defined in patients in vivo. This study investigated, in patients with short-term and chronic left ventricular dysfunction, the relation between hemodynamic status and the extent of regional dyssynergia measured by two-dimensional echocardiography with quantitative endocardial surface mapping. Sixty patients were classified into hemodynamic groups by pulmonary capillary wedge pressure and cardiac index. Two-dimensional echocardiograms were used to calculate left ventricular endocardial surface area index (ESAi), abnormal wall motion index (AWMi), percentage myocardial dysfunction (%MD), and number of wall motion abnormalities. All patients in class 4 (high pulmonary capillary wedge pressure and low cardiac index had > or = 60% MD. With univariate analysis, hemodynamic class correlated with ESAi, AWMi, %MD, the number of wall motion abnormalities, and two clinical variables (number of infarctions and use of diuretic agents). By stepwise linear regression, only AWMi and the number of infarctions were independently predictive of hemodynamic status.


Assuntos
Mapeamento Potencial de Superfície Corporal , Ecocardiografia , Isquemia Miocárdica/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Débito Cardíaco , Diuréticos/administração & dosagem , Diuréticos/uso terapêutico , Endocárdio/fisiopatologia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Humanos , Modelos Lineares , Masculino , Análise Multivariada , Isquemia Miocárdica/diagnóstico por imagem , Pressão Propulsora Pulmonar , Sístole , Disfunção Ventricular Esquerda/diagnóstico por imagem
20.
JAMA ; 282(18): 1731-6, 1999 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-10568645

RESUMO

CONTEXT: Vigorous physical exertion transiently increases the risk of acute myocardial infarction (MI), but little is known about the clinical characteristics of exertion-related MI. OBJECTIVE: To compare the clinical and angiographic characteristics of patients who had an exertion-related acute MI vs those who experienced an MI not related to exertion. DESIGN AND SETTING: Prospective observational cohort study of patients with an acute MI referred to a tertiary care hospital for primary angioplasty. PATIENTS: Of 1048 patients with acute MI, 640 (64 who experienced an exertion-related MI and 576 who did not) were selected for treatment with primary angioplasty and admitted between August 1995 and November 1998. MAIN OUTCOME MEASURES: Clinical characteristics of the patients, including their habitual physical activity (determined by the Framingham Physical Activity Index and the Lipid Research Clinic Physical Activity Questionnaire), angiographic findings during coronary angiography, and the relative risk (RR) of MI during exertion. RESULTS: Patients who experienced exertion-related MI were more frequently men (86% vs 68%), hyperlipidemic (62% vs 40%), and smokers (59% vs 37%), were more likely to present with ventricular fibrillation (20% vs 11%), Killip classification III or IV heart failure (44% vs 22%), single-vessel disease (50% vs 28%), and a large thrombus in the infarct artery (64% vs 35%) and were more likely to be classified as having very low or low activity (84% vs 66%). The RR of experiencing an MI during exertion was 10.1 times greater than the risk at other times (95% confidence interval [CI], 1.6-65.6), with the highest risk among patients classified as very low active (RR, 30.5; 95% CI, 4.4-209.9) and low active (RR, 20.9; 95% CI, 3.1-142.1). CONCLUSION: These results show that exertion-related MIs occur in habitually inactive people with multiple cardiac risk factors. These individuals may benefit from modest exercise training and aggressive risk-factor modification before they perform vigorous physical activity.


Assuntos
Infarto do Miocárdio/etiologia , Infarto do Miocárdio/fisiopatologia , Esforço Físico/fisiologia , Cateterismo Cardíaco , Angiografia Coronária , Feminino , Humanos , Modelos Logísticos , Masculino , Infarto do Miocárdio/diagnóstico por imagem , Estudos Prospectivos , Risco