Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Strahlenther Onkol ; 199(7): 621-630, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37285038

RESUMO

BACKGROUND: Single-session cardiac stereotactic radiation therapy (SBRT) has demonstrated promising results for patients with refractory ventricular tachycardia (VT). However, the full safety profile of this novel treatment remains unknown and very limited data from prospective clinical multicenter trials are available. METHODS: The prospective multicenter multiplatform RAVENTA (radiosurgery for ventricular tachycardia) study assesses high-precision image-guided cardiac SBRT with 25 Gy delivered to the VT substrate determined by high-definition endocardial and/or epicardial electrophysiological mapping in patients with refractory VT ineligible for catheter ablation and an implanted cardioverter defibrillator (ICD). Primary endpoint is the feasibility of full-dose application and procedural safety (defined as an incidence of serious [grade ≥ 3] treatment-related complications ≤ 5% within 30 days after therapy). Secondary endpoints comprise VT burden, ICD interventions, treatment-related toxicity, and quality of life. We present the results of a protocol-defined interim analysis. RESULTS: Between 10/2019 and 12/2021, a total of five patients were included at three university medical centers. In all cases, the treatment was carried out without complications. There were no serious potentially treatment-related adverse events and no deterioration of left ventricular ejection fraction upon echocardiography. Three patients had a decrease in VT episodes during follow-up. One patient underwent subsequent catheter ablation for a new VT with different morphology. One patient with local VT recurrence died 6 weeks after treatment in cardiogenic shock. CONCLUSION: The interim analysis of the RAVENTA trial demonstrates early initial feasibility of this new treatment without serious complications within 30 days after treatment in five patients. Recruitment will continue as planned and the study has been expanded to further university medical centers. TRIAL REGISTRATION NUMBER: NCT03867747 (clinicaltrials.gov). Registered March 8, 2019. Study start: October 1, 2019.


Assuntos
Radiocirurgia , Taquicardia Ventricular , Humanos , Radiocirurgia/métodos , Volume Sistólico , Estudos Prospectivos , Qualidade de Vida , Estudos de Viabilidade , Função Ventricular Esquerda , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
2.
J Appl Clin Med Phys ; 24(8): e14077, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37357570

RESUMO

INTRODUCTION: Performing lymphoscintigraphy in a separate room, frees up the conventional gamma camera, coupled with the desire to directly localize sentinel lymph nodes (SLN) in the operating theatre has led to the development of high-resolution semiconductor-detector based handheld gamma-cameras, CrystalCam. METHODS: This work consists of phantom and clinical studies. For the first part, a Jaszczak phantom with hollow spheres of various volumes were filled with the 99m Tc and the camera's sensitivity was measured at various distances to assess the possibilities and limitations of the device. The clinical study evaluates the effectiveness of CrystalCam in localizing SLN in 40 consecutive malignant melanoma patients compared to both conventional planar lymphoscintigraphy and hybrid SPECT/CT. SLNs detected by planar lymphoscintigraphy were marked on the patients' skin using a UV-marker. CrystalCam images were acquired in another room by another examiner and the SLNs were marked with a felt pen. The detected nodes by both camera systems were evaluated using UV-lamp and normal light to visualize the UV- and felt pen marks respectively. The concordance rate of the SLNs and higher-echelon nodes localized by both planar scintigraphy and CrystalCam imaging with respect to the total SLNs and higher-echelon nodes detected by SPECT/CT imaging are compared and statistically analyzed. RESULTS: The results of the phantom study show a good correlation between activity and count-rates for all distancesSPECT/CT, CrystalCamm, and planar lymphoscintigraphy detected 69, 58, and 61 SLNs respectively. The concordance rate of 95.65% by the CrystalCam and planar scintigraphy implies both cameras are statistically coequal in preoperative SLN detection of malignant melanoma. For the higher-echelon nodes, SPECT/CT, planar and CrystalCam imaging systems identified 82, 48, and 13 respectively; thus, CrystalCam was statistically inferior to planar imaging. CONCLUSION: The handheld CrystalCam is a reliable instrument for localizing SLNs in surgical centers without an on-site nuclear medicine department.


Assuntos
Melanoma , Linfonodo Sentinela , Humanos , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/patologia , Linfocintigrafia/métodos , Câmaras gama , Metástase Linfática , Melanoma/diagnóstico por imagem , Melanoma/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Melanoma Maligno Cutâneo
3.
Arthroscopy ; 38(3): 860-869, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34052378

RESUMO

PURPOSE: The goal of the present study was to evaluate a potential tunnel convergence in combined anterior cruciate ligament (ACL) reconstruction using the anteromedial portal technique and lateral extra-articular tenodesis (LET). METHODS: Ten fresh frozen femora were dissected and a K-wires were inserted into the middle of the ACL stump, according to an ACL reconstruction at 110° and 140° knee flexion. ACL reconstruction at 120° and 130° was simulated. Seven K-wires with different femoral insertion sites and angulations were drilled into the lateral femoral condyle relative to the lateral epicondyle (E3: 8 mm proximal and 4 mm posterior; E1: 5 mm proximal and 5 mm anterior and E2: over-the-top position). Tunnel conflict rate was evaluated using a measuring arm and a metrology software. RESULTS: Drilling the femoral ACL tunnel in low knee flexion (110°-120°) significantly (P < .001) reduced the tunnel conflict rate compared to the ACL drilled in high knee flexion (130°-140°). Changing the insertion point from proximal and posterior (E3) to proximal and anterior (E1) showed a reduced tunnel conflict rate from 40 ± 21.2% to 15 ± 26% and no tunnel conflict for an ACL drilled at 110°-130° knee flexion. CONCLUSION: A possible tunnel conflict in simultaneous ACL reconstruction using the AMP technique and LET was dependent on ACL knee flexion angle, LET insertion site, and angulation. This posed the dilemma that no generally applicable LET configuration could be recommended to avoid a tunnel conflict. However, it appears that an insertion point located proximal and anterior to the lateral epicondyle results in less tunnel conflicts than an insertion point located proximal and posterior. CLINICAL RELEVANCE: An insertion point located proximal and anterior to the lateral epicondyle with a 30° proximal and 30° anterior angulation could reliably avoid a tunnel conflict when the ACL was drilled between 110 and 130° using a low anteromedial portal.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Cadáver , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia
4.
Arch Orthop Trauma Surg ; 142(8): 1859-1864, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33844054

RESUMO

INTRODUCTION: The number of atraumatic stress fractures of the scapular spine associated with reverse shoulder arthroplasty is increasing. At present, there is no consensus regarding the optimal treatment strategy. Due to the already weakened bone, fractures of the scapular spine require a high fixation stability. Higher fixation strength may be achieved by double plating. The aim of this study was to evaluate the biomechanical principles of double plating in comparison to single plating for scapular spine fractures. METHODS: In this study, eight pairs (n = 16) of human shoulders were randomised pairwise into two groups. After an osteotomy at the level of the spinoglenoid notch, one side of each pair received fracture fixation with a single 3.5 LCP (Locking Compression Plate) plate. The contralateral scapular spine was fixed with a 3.5 LCP and an additional 2.7 LCP plate in 90-90 configuration. The biomechanical test protocol consisted of 700 cycles of dynamic loading and a load-to-failure test with a servohydraulic testing machine. Failure was defined as macroscopic catastrophic failure (screw cut-out, plate breakage). The focus was set on the results of specimens with osteoporotic bone quality. RESULTS: In specimens with an osteoporotic bone mineral density (BMD; n = 12), the mean failure load was significantly higher for the double plate group compared to single plating (471 N vs. 328 N; p = 0.029). Analysis of all specimens (n = 16) including four specimens without osteoporotic BMD revealed no significant differences regarding stiffness and failure load (p > 0.05). CONCLUSION: Double plating may provide higher fixation strength in osteoporotic bone in comparison to a single plate alone. This finding is of particular relevance for fixation of scapular spine fractures following reverse shoulder arthroplasty. LEVEL OF EVIDENCE: Controlled laboratory study.


Assuntos
Osteoporose , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Fenômenos Biomecânicos , Placas Ósseas , Cadáver , Fixação Interna de Fraturas/métodos , Humanos , Fraturas por Osteoporose/cirurgia
5.
Strahlenther Onkol ; 197(7): 581-591, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32588102

RESUMO

PURPOSE: For step-and-shoot robotic stereotactic radiosurgery (SRS) the dose delivered over time, called local tumor-dose-rate (TDR), may strongly vary during treatment of multiple lesions. The authors sought to evaluate technical parameters influencing TDR and correlate TDR to clinical outcome. MATERIAL AND METHODS: A total of 23 patients with 162 oligo (1-3) and multiple (>3) brain metastases (OBM/MBM) treated in 33 SRS sessions were retrospectively analyzed. Median PTV were 0.11 cc (0.01-6.36 cc) and 0.50 cc (0.12-3.68 cc) for OBM and MBM, respectively. Prescription dose ranged from 16 to 20 Gy prescribed to the median 70% isodose line. The maximum dose-rate for planning target volume (PTV) percentage p in time span s during treatment (TDRs,p) was calculated for various p and s based on treatment log files and in-house software. RESULTS: TDR60min,98% was 0.30 Gy/min (0.23-0.87 Gy/min) for OBM and 0.22 Gy/min (0.12-0.63 Gy/min) for MBM, respectively, and increased by 0.03 Gy/min per prescribed Gy. TDR60min,98% strongly correlated with treatment time (ρ = -0.717, p < 0.001), monitor units (MU) (ρ = -0.767, p < 0.001), number of beams (ρ = -0.755, p < 0.001) and beam directions (ρ = -0.685, p < 0.001) as well as lesions treated per collimator (ρ = -0.708, P < 0.001). Median overall survival (OS) was 20 months and 1­ and 2­year local control (LC) was 98.8% and 90.3%, respectively. LC did not correlate with any TDR, but tumor response (partial response [PR] or complete response [CR]) correlated with all TDR in univariate analysis (e.g., TDR60min,98%: hazard ration [HR] = 0.974, confidence interval [CI] = 0.952-0.996, p = 0.019). In multivariate analysis only concomitant targeted therapy or immunotherapy and breast cancer tumor histology remained a significant factor for tumor response. Local grade ≥2 radiation-induced tissue reactions were noted in 26.3% (OBM) and 5.2% (MBM), respectively, mainly influenced by tumor volume (p < 0.001). CONCLUSIONS: Large TDR variations are noted during MBM-SRS which mainly arise from prolonged treatment times. Clinically, low TDR corresponded with decreased local tumor responses, although the main influencing factor was concomitant medication.


Assuntos
Neoplasias Encefálicas/radioterapia , Radiocirurgia/métodos , Neoplasias Encefálicas/cirurgia , Humanos , Doses de Radiação , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/métodos , Resultado do Tratamento , Carga Tumoral/efeitos da radiação
6.
BMC Musculoskelet Disord ; 22(1): 841, 2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-34592967

RESUMO

BACKGROUND: The implantation of screws is a standard procedure in musculoskeletal surgery. Heat can induce thermal osteonecrosis, damage the bone and lead to secondary problems like implant loosening and secondary fractures. The aim of this study was to investigate whether screw insertion generates temperatures that can cause osteonecrosis. METHODS: We measured the temperature of twenty human femur diaphysis in a total of 120 measurements, while screws of different material (stainless steel and titanium alloy) and different design (locking and cortex screw) were inserted in three different screwing modes (manual vs. machine screwing at full and reduced rotational speed) with 6 thermocouples (3 cis and 3 trans cortex). Each was placed at a depth of 2 mm with a distance of 1.5 mm from the outer surface of the screw. RESULTS: The screw design (cortical > locking), the site of measurement (trans-cortex > cis-cortex) and the type of screw insertion (hand insertion > machine insertion) have an influence on the increase in bone temperature. The screw material (steel > titanium), the site of measurement (trans-cortex > cis-cortex) and the type of screw insertion (machine insertion > hand insertion) have an influence on the time needed to cool below critical temperature values. The combination of the two parameters (maximum temperature and cooling time), which is particularly critical for osteonecrosis, is found only at the trans-cortex. CONCLUSION: Inserting a screw hast the potential to increase the temperature of the surrounding bone tissue above critical values and therefore can induce osteonecrosis. The trans-cortex is the critical area for the development of temperatures above the osteonecrosis threshold, making effective cooling by irrigation difficult. It would be conceivable to cool the borehole with cold saline solution before inserting the screw or to cool the screw in cold saline solution. If possible, insertion by hand should be considered.


Assuntos
Diáfises , Temperatura Alta , Fenômenos Biomecânicos , Parafusos Ósseos/efeitos adversos , Osso e Ossos , Diáfises/diagnóstico por imagem , Diáfises/cirurgia , Humanos , Aço Inoxidável
7.
Knee Surg Sports Traumatol Arthrosc ; 29(8): 2631-2639, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33839898

RESUMO

PURPOSE: Surgical treatment of shoulder instability caused by anterior glenoid bone loss is based on a critical threshold of the defect size. Recent studies indicate that the glenoid concavity is essential for glenohumeral stability. However, biomechanical proof of this principle is lacking. The aim of this study was to evaluate whether glenoid concavity allows a more precise assessment of glenohumeral stability than the defect size alone. METHODS: The stability ratio (SR) is a biomechanical estimate of glenohumeral stability. It is defined as the maximum dislocating force the joint can resist related to a medial compression force. This ratio was determined for 17 human cadaveric glenoids in a robotic test setup depending on osteochondral concavity and anterior defect size. Bony defects were created gradually, and a 3D measuring arm was used for morphometric measurements. The influence of defect size and concavity on the SR was examined using linear models. In addition, the morphometrical-based bony shoulder stability ratio (BSSR) was evaluated to prove its suitability for estimation of glenohumeral stability independent of defect size. RESULTS: Glenoid concavity is a significant predictor for the SR, while the defect size provides minor informative value. The linear model featured a high goodness of fit with a determination coefficient of R2 = 0.98, indicating that 98% of the SR is predictable by concavity and defect size. The low mean squared error (MSE) of 4.2% proved a precise estimation of the SR. Defect size as an exclusive predictor in the linear model reduced R2 to 0.9 and increased the MSE to 25.7%. Furthermore, the loss of SR with increasing defect size was shown to be significantly dependent on the initial concavity. The BSSR as a single predictor for glenohumeral stability led to highest precision with MSE = 3.4%. CONCLUSION: Glenoid concavity is a crucial factor for the SR. Independent of the defect size, the computable BSSR is a precise biomechanical estimate of the measured SR. The inclusion of glenoid concavity has the potential to influence clinical decision-making for an improved and personalised treatment of glenohumeral instability with anterior glenoid bone loss.


Assuntos
Cavidade Glenoide , Instabilidade Articular , Luxação do Ombro , Articulação do Ombro , Fenômenos Biomecânicos , Cadáver , Cavidade Glenoide/diagnóstico por imagem , Cavidade Glenoide/cirurgia , Humanos , Instabilidade Articular/cirurgia , Ombro , Articulação do Ombro/cirurgia
8.
Knee Surg Sports Traumatol Arthrosc ; 29(11): 3800-3808, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33454831

RESUMO

PURPOSE: The purpose of this study was to examine the length change patterns of the native medial structures of the knee and determine the effect on graft length change patterns for different tibial and femoral attachment points for previously described medial reconstructions. METHODS: Eight cadaveric knee specimens were prepared by removing the skin and subcutaneous fat. The sartorius fascia was divided to allow clear identification of the medial ligamentous structures. Knees were then mounted in a custom-made rig and the quadriceps muscle and the iliotibial tract were loaded, using cables and hanging weights. Threads were mounted between tibial and femoral pins positioned in the anterior, middle, and posterior parts of the attachment sites of the native superficial medial collateral ligament (sMCL) and posterior oblique ligament (POL). Pins were also placed at the attachment sites relating to two commonly used medial reconstructions (Bosworth/Lind and LaPrade). Length changes between the tibiofemoral pin combinations were measured using a rotary encoder as the knee was flexed through an arc of 0-120°. RESULTS: With knee flexion, the anterior fibres of the sMCL tightened (increased in length 7.4% ± 2.9%) whilst the posterior fibres slackened (decreased in length 8.3% ± 3.1%). All fibre regions of the POL displayed a uniform lengthening of approximately 25% between 0 and 120° knee flexion. The most isometric tibiofemoral combination was between pins placed representing the middle fibres of the sMCL (Length change = 5.4% ± 2.1% with knee flexion). The simulated sMCL reconstruction that produced the least length change was the Lind/Bosworth reconstruction with the tibial attachment at the insertion of the semitendinosus and the femoral attachment in the posterior part of the native sMCL attachment side (5.4 ± 2.2%). This appeared more isometric than using the attachment positions described for the LaPrade reconstruction (10.0 ± 4.8%). CONCLUSION: The complex behaviour of the native MCL could not be imitated by a single point-to-point combination and surgeons should be aware that small changes in the femoral MCL graft attachment position will significantly effect graft length change patterns. Reconstructing the sMCL with a semitendinosus autograft, left attached distally to its tibial insertion, would appear to have a minimal effect on length change compared to detaching it and using the native tibial attachment site. A POL graft must always be tensioned near extension to avoid capturing the knee or graft failure.


Assuntos
Ligamento Colateral Médio do Joelho , Fenômenos Biomecânicos , Cadáver , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Ligamentos Articulares , Ligamento Colateral Médio do Joelho/cirurgia , Tíbia/cirurgia
9.
J Shoulder Elbow Surg ; 30(12): 2852-2861, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34022364

RESUMO

BACKGROUND: Fractures of the proximal humerus are common. The most frequent surgical treatment option is open reduction and locking plate fixation. Multifragmentary fractures, including 3- and 4-part fractures, are especially challenging to treat because they correlate with an increased risk of fixation failure. In the past, several mechanisms of additional fixation were investigated, but none directly addressed the lesser tuberosity (LT). The goal of this study was to investigate the biomechanical impact of additional anterior fracture fixation in lateral locked plating (LLP) of 4-part proximal humeral fractures (PHFs). METHODS: Twenty-seven fresh frozen human shoulder specimens (mean age, 80 years) with intact rotator cuffs (RCs) were randomized into 4 groups: 3-part PHF with LLP and RC cerclage (n = 6); 4-part PHF with LLP and RC cerclage as standard of care (n = 7); 4-part PHF with LLP, RC cerclage, and 2 anterior 3.5-mm cortical screws (n = 7); and 4-part PHF with LLP, RC cerclage, and additional anterior one-third tubular plate (additional anterior plating [AAP], n = 7). Static load of the RC was simulated with weights. A force-controlled cyclic loading test was performed with a servo-hydraulic testing machine, followed by load-to-failure testing. An optical motion capture system recorded humeral head range of motion. RESULTS: LLP of a 4-part PHF showed more humeral head motion than LLP of a 3-part PHF without fracture of the LT (P < .001). Fixing the LT to the humeral head with two 3.5-mm screws significantly reduced humeral head motion compared with LLP with RC cerclage alone (P < .006). Using AAP significantly increased the construct stiffness compared with the standard of care (P = .03). CONCLUSION: LLP of a 4-part PHF is biomechanically less stable than LLP of a 3-part PHF without fracture of the LT. Additional screw fixation of the LT in 4-part PHFs improves stability compared with LLP alone. In case of metaphyseal comminution, AAP is favorable from a biomechanical perspective.


Assuntos
Fraturas do Ombro , Ombro , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas , Humanos , Cabeça do Úmero/diagnóstico por imagem , Cabeça do Úmero/cirurgia , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia
10.
Strahlenther Onkol ; 196(1): 23-30, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31673718

RESUMO

PURPOSE: Single-session cardiac stereotactic body radiotherapy, called cardiac radiosurgery (CRS) or radioablation (RA), may offer a potential treatment option for patients with refractory ventricular tachycardia (VT) and electrical storm who are otherwise ineligible for catheter ablation. However, there is only limited clinical experience. We now present the first-in-patient treatment using (CRS/RA) for VT in Germany. METHODS: A 78-year-old male patient with dilated cardiomyopathy and significantly reduced ejection fraction (15%) presented with monomorphic VT refractory to poly-anti-arrhythmic medication and causing multiple implantable cardioverter-defibrillator (ICD) interventions over the course of several weeks, necessitating prolonged treatment on an intensive care unit. Ultra-high-resolution electroanatomical voltage mapping (EVM) revealed a re-entry circuit in the cardiac septum inaccessible for catheter ablation. Based on the EVM, CRS/RA with a single session dose of 25 Gy (83% isodose) was delivered to the VT substrate (8.1 cc) using a c-arm-based high-precision linear accelerator on November 30, 2018. RESULTS: CRS/RA was performed without incident and dysfunction of the ICD was not observed. Following the procedure, a significant reduction in monomorphic VT from 5.0 to 1.6 episodes per week and of ICD shock interventions by 81.2% was observed. Besides periprocedural nausea with a single episode of vomiting, no treatment-associated side effects were noted. Unfortunately, the patient died 57 days after CRS/RA due to sepsis-associated cardiac circulatory failure after Clostridium difficile-associated colitis developed during rehabilitation. Histopathologic examination of the heart as part of a clinical autopsy revealed diffuse fibrosis on most sections of the heart without apparent differences between the target area and the posterior cardiac wall serving as a control. CONCLUSION: CRS/RA appears to be a possible treatment option for otherwise untreatable patients suffering from refractory VT and electrical storm. A relevant reduction in VT incidence and ICD interventions was observed, although long-term outcome and consequences of CRS/RA remain unclear. Clinical trials are strongly warranted and have been initiated.


Assuntos
Admissão do Paciente , Radiocirurgia/métodos , Taquicardia Ventricular/radioterapia , Idoso , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/patologia , Cardiomiopatia Dilatada/radioterapia , Terapia Combinada , Desfibriladores Implantáveis , Evolução Fatal , Septos Cardíacos/patologia , Septos Cardíacos/efeitos da radiação , Humanos , Masculino , Aceleradores de Partículas , Taquicardia Ventricular/patologia
11.
J Endovasc Ther ; 27(2): 258-265, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32096435

RESUMO

Purpose: To compare experimentally the biomechanical properties of the Viabahn Balloon-Expandable Stent Graft (VBX) with the widely used Advanta V12/iCast in the role of bridging stent-grafts for fenestrated endovascular aortic repair. Materials and Methods: Test sheets made of polyester having 2 rows of 5 fenestrations in 6-mm and 8-mm diameters were used to simulate a commercially made fenestrated aortic endograft. In total, 40 stent-grafts measuring 6×39 mm and 8×39 mm (10 of each size for each stent-graft) were implanted in fenestration sheets immersed in a 37°C water bath. After flaring, all stent-grafts were evaluated using microscopy and radiography. Biomechanical evaluation included pullout and the shear stress force testing; results are reported in Newtons (N) as the median (minimum-maximum). Results: After flaring, no damage or fracture to the stent-graft structures were detected. Pullout forces for the 6-mm stent-grafts were 27.1 N (20.0-28.9) for the VBX and 16.6 N (14.7-19.2) for the Advanta (p=0.008). Pullout forces for the 8-mm stent-grafts were 20.1 N (14.8-21.5) for the VBX and 15.8 N (12.4-17.5) for the Advanta (p=0.095). The shear stress forces necessary to dislocate the device at 150% stent diameter displacement was 12.5 N (VBX) vs 14.7 N (Advanta) for the 6-mm devices and 23.3 N (VBX) vs 20.2 N (Advanta) for the 8-mm stents (p>0.99 and p=0.222, respectively). Conclusion: In vitro tests simulating external pull and shear forces on bridging stent-grafts implanted in fenestrations showed that the VBX had resistance to dislocation equivalent to a well-known control device.


Assuntos
Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Análise de Falha de Equipamento , Migração de Corpo Estranho/etiologia , Teste de Materiais , Desenho de Prótese , Falha de Prótese , Fatores de Risco , Estresse Mecânico
12.
Int J Mol Sci ; 21(8)2020 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-32325713

RESUMO

Integrins are a family of transmembrane proteins, involved in substrate recognition and cell adhesion in cross-talk with the extra cellular matrix. In this study, we investigated the influence of integrin α2ß1 on tendons, another collagen type I-rich tissue of the musculoskeletal system. Morphological, as well as functional, parameters were analyzed in vivo and in vitro, comparing wild-type against integrin α2ß1 deficiency. Tenocytes lacking integrin α2ß1 produced more collagen in vitro, which is similar to the situation in osseous tissue. Fibril morphology and biomechanical strength proved to be altered, as integrin α2ß1 deficiency led to significantly smaller fibrils as well as changes in dynamic E-modulus in vivo. This discrepancy can be explained by a higher collagen turnover: integrin α2ß1-deficient cells produced more matrix, and tendons contained more residual C-terminal fragments of type I collagen, as well as an increased matrix metalloproteinase-2 activity. A greatly decreased percentage of non-collagenous proteins may be the cause of changes in fibril diameter regulation and increased the proteolytic degradation of collagen in the integrin-deficient tendons. The results reveal a significant impact of integrin α2ß1 on collagen modifications in tendons. Its role in tendon pathologies, like chronic degradation, will be the subject of future investigations.


Assuntos
Colágeno/metabolismo , Integrina alfa2beta1/deficiência , Metaloproteinase 2 da Matriz/metabolismo , Tendões/metabolismo , Tenócitos/metabolismo , Animais , Fenômenos Biomecânicos , Células Cultivadas , Colágeno/ultraestrutura , Feminino , Fibroblastos/metabolismo , Gelatinases/metabolismo , Integrina alfa2beta1/genética , Integrina alfa2beta1/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Microscopia Eletrônica de Transmissão , Proteína-Lisina 6-Oxidase/metabolismo , Tendões/citologia , Tendões/enzimologia , Tendões/ultraestrutura
13.
J Endovasc Ther ; 26(3): 361-368, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30975017

RESUMO

PURPOSE: To evaluate the safety and integrity of a new stent-graft as a potential bridging device in fenestrated stent-grafts using an in vitro fenestrated model. MATERIALS AND METHODS: Polyester test sheets with ten 6-mm- or 8-mm-diameter fenestrations were used to simulate a fenestrated main body endoprosthesis. In total, 50 Viabahn balloon-expandable (VBX) stent-grafts of varying lengths (29 and 39 mm) and diameters (6, 7, and 8 mm) were implanted in the fitting fenestrations. After release, the 6- and 7-mm-diameter stent-grafts were flared with a 10×20-mm angioplasty balloon; a 12×20-mm balloon was used in the 8-mm-diameter devices. Safety of the devices was defined as absence of fractures detected on radiography or computed tomography (CT), as well as material failure detected by microscopy and water permeability testing. The forces (in Newtons, N) needed for perpendicular dislocation (pullout force) and axial dislocation (shear stress force) were also evaluated. RESULTS: Forty VBX stent-grafts were subjected to digital radiographic imaging and multiplanar CT. None showed any stent fracture. Subsequent microscopy indicated no damage to the fabric or separation of the graft after flaring. Ten VBX stent-grafts underwent water permeability testing after flaring; no water passed through the graft wall during a 10-minute period under an intraluminal pressure at 120 mm Hg. Testing of 25 VBX stent-grafts revealed initial pullout forces between 11.3 and 31 N. Shear stress tests showed that the average force needed to dislocate the stent-grafts by 50% of their diameter ranged between 5.75 and 6.91 N (mean 6.1±0.5 N) for the 6-mm stents and between 3.31 and 5.4 N (mean 4.4±0.8) for the 8-mm stents. CONCLUSION: This preliminary study demonstrated the applicability of the VBX as a bridging stent-graft in a simulated fenestration model. A comparison with other stent-grafts and clinical assessment are required.


Assuntos
Angioplastia com Balão/instrumentação , Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Stents , Angioplastia com Balão/efeitos adversos , Aneurisma Aórtico/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Hemodinâmica , Humanos , Teste de Materiais , Permeabilidade , Desenho de Prótese , Falha de Prótese , Estresse Mecânico
14.
J Endovasc Ther ; 26(6): 787-794, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31379276

RESUMO

Purpose: To investigate 2 generations of balloon-expandable covered stents as potential bridging devices using an in vitro model of stent-graft fenestrations. Materials and Methods: Twenty BeGraft and 20 BeGraft+ cobalt-chromium stents covered in expanded polytetrafluoroethylene (ePTFE) in 6- and 8-mm diameters were tested in sheets mimicking stent-graft fenestrations. Microscopy and radiography were employed to evaluate stent morphology after flaring. In vitro bench tests measured maximum pullout (perpendicular displacement) and the shear stress (axial displacement) forces needed to dislocate the stents. Results: No alteration of ePTFE coverage was detected in the flared stents. Digital radiography and computed tomography showed marked alteration of the stent geometry, which was more pronounced in the BeGraft group. No fractures were detected. Median (minimum-maximum) pullout forces for the 6-mm stent-grafts were 17.1 N (15.8-19.6) for the BeGraft device and 30.4 N (20.2-31.9) for the BeGraft+ device (p=0.006). Median (minimum-maximum) pullout forces for the 8-mm stent-grafts were 11.3 N (11-12.1) for the BeGraft device and 21.8 N (18.2-25.5) for the BeGraft+ device (p<0.001). The shear stress test showed median forces of 10.5 vs 15.28 N at 150% of the stent diameter for the 6-mm BeGraft and BeGraft+ stent-grafts, respectively, and 15.23 vs 20.72 N at 150% stent diameter for the 8-mm models (p=0.016 and 0.017, respectively). Conclusion: Flaring changed the stent geometry but did not provoke stent fractures. The BeGraft+ is superior to the BeGraft in terms of pullout and shear stress forces, demonstrating greater resilience.


Assuntos
Angioplastia com Balão/instrumentação , Aorta/cirurgia , Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Stents , Angioplastia com Balão/efeitos adversos , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Ligas de Cromo , Análise de Falha de Equipamento , Humanos , Teste de Materiais , Politetrafluoretileno , Desenho de Prótese , Falha de Prótese , Estresse Mecânico
15.
Strahlenther Onkol ; 194(9): 843-854, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29802435

RESUMO

PURPOSE: To investigate the quality of treatment plans of spinal radiosurgery derived from different planning and delivery systems. The comparisons include robotic delivery and intensity modulated arc therapy (IMAT) approaches. Multiple centers with equal systems were used to reduce a bias based on individual's planning abilities. The study used a series of three complex spine lesions to maximize the difference in plan quality among the various approaches. METHODS: Internationally recognized experts in the field of treatment planning and spinal radiosurgery from 12 centers with various treatment planning systems participated. For a complex spinal lesion, the results were compared against a previously published benchmark plan derived for CyberKnife radiosurgery (CKRS) using circular cones only. For two additional cases, one with multiple small lesions infiltrating three vertebrae and a single vertebra lesion treated with integrated boost, the results were compared against a benchmark plan generated using a best practice guideline for CKRS. All plans were rated based on a previously established ranking system. RESULTS: All 12 centers could reach equality (n = 4) or outperform (n = 8) the benchmark plan. For the multiple lesions and the single vertebra lesion plan only 5 and 3 of the 12 centers, respectively, reached equality or outperformed the best practice benchmark plan. However, the absolute differences in target and critical structure dosimetry were small and strongly planner-dependent rather than system-dependent. Overall, gantry-based IMAT with simple planning techniques (two coplanar arcs) produced faster treatments and significantly outperformed static gantry intensity modulated radiation therapy (IMRT) and multileaf collimator (MLC) or non-MLC CKRS treatment plan quality regardless of the system (mean rank out of 4 was 1.2 vs. 3.1, p = 0.002). CONCLUSIONS: High plan quality for complex spinal radiosurgery was achieved among all systems and all participating centers in this planning challenge. This study concludes that simple IMAT techniques can generate significantly better plan quality compared to previous established CKRS benchmarks.


Assuntos
Benchmarking , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Coluna Vertebral , Vértebras Torácicas , Idoso , Algoritmos , Fracionamento da Dose de Radiação , Humanos , Recidiva Local de Neoplasia/radioterapia , Órgãos em Risco , Radiocirurgia/instrumentação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/instrumentação , Reirradiação , Procedimentos Cirúrgicos Robóticos/instrumentação , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/secundário , Vértebras Torácicas/cirurgia
16.
J Appl Clin Med Phys ; 17(4): 59-72, 2016 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-27455475

RESUMO

Radiation Protection in Radiology, Nuclear Medicine and Radio Oncology is of the utmost importance. Radioiodine therapy is a frequently used and effective method for the treatment of thyroid disease. Prior to each therapy the radioactivity of the [131I]-capsule must be determined to prevent misadministration. This leads to a significant radiation exposure to the staff. We describe an alternative method, allowing a considerable reduction of the radiation exposure. Two [131I]-capsules (A01 = 2818.5; A02 = 7355.0 MBq) were measured multiple times in their own delivery lead containers - that is to say, [131I]-capsules remain inside the containers during the measurements (shielded measurement) using a dose calibrator and a well-type and a thyroid uptake probe. The results of the shielded measurements were correlated linearly with the [131I]-capsules radioactivity to create calibration curves for the used devices. Additional radioactivity measurements of 50 [131I]-capsules of different radioactivities were done to validate the shielded measuring method. The personal skin dose rate (HP(0.07)) was determined using calibrated thermo luminescent dosimeters. The determination coefficients for the calibration curves were R2 > 0.9980 for all devices. The relative uncertainty of the shielded measurement was < 6.8%. At a distance of 10 cm from the unshielded capsule the HP(0.07) was 46.18 µSv/(GBq•s), and on the surface of the lead container containing the [131I]-capsule the HP(0.07) was 2.99 and 0.27 µSv/(GBq•s) for the two used container sizes. The calculated reduction of the effective dose by using the shielded measuring method was, depending on the used container size, 74.0% and 97.4%, compared to the measurement of the unshielded [131I]-capsule using a dose calibrator. The measured reduction of the effective radiation dose in the practice was 56.6% and 94.9 for size I and size II containers. The shielded [131I]-capsule measurement reduces the radiation exposure to the staff significantly and offers the same accuracy of the unshielded measurement in the same amount of time. In order to maintain the consistency of the measuring method, monthly tests have to be done by measuring a [131I]-capsule with known radioactivity.


Assuntos
Exposição por Inalação/análise , Radioisótopos do Iodo/análise , Corpo Clínico Hospitalar , Exposição à Radiação/análise , Proteção Radiológica/normas , Radiometria/métodos , Humanos , Radioisótopos do Iodo/uso terapêutico , Doses de Radiação
17.
J Appl Clin Med Phys ; 17(3): 313-330, 2016 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-27167291

RESUMO

Stereotactic radiosurgery (SRS) is the accurate, conformal delivery of high-dose radiation to well-defined targets while minimizing normal structure doses via steep dose gradients. While inverse treatment planning (ITP) with computerized optimization algorithms are routine, many aspects of the planning process remain user-dependent. We performed an international, multi-institutional benchmark trial to study planning variability and to analyze preferable ITP practice for spinal robotic radiosurgery. 10 SRS treatment plans were generated for a complex-shaped spinal metastasis with 21 Gy in 3 fractions and tight constraints for spinal cord (V14Gy < 2 cc, V18Gy < 0.1 cc) and target (coverage > 95%). The resulting plans were rated on a scale from 1 to 4 (excellent-poor) in five categories (constraint compliance, optimization goals, low-dose regions, ITP complexity, and clinical acceptability) by a blinded review panel. Additionally, the plans were mathemati-cally rated based on plan indices (critical structure and target doses, conformity, monitor units, normal tissue complication probability, and treatment time) and compared to the human rankings. The treatment plans and the reviewers' rankings varied substantially among the participating centers. The average mean overall rank was 2.4 (1.2-4.0) and 8/10 plans were rated excellent in at least one category by at least one reviewer. The mathematical rankings agreed with the mean overall human rankings in 9/10 cases pointing toward the possibility for sole mathematical plan quality comparison. The final rankings revealed that a plan with a well-balanced trade-off among all planning objectives was preferred for treatment by most par-ticipants, reviewers, and the mathematical ranking system. Furthermore, this plan was generated with simple planning techniques. Our multi-institutional planning study found wide variability in ITP approaches for spinal robotic radiosurgery. The participants', reviewers', and mathematical match on preferable treatment plans and ITP techniques indicate that agreement on treatment planning and plan quality can be reached for spinal robotic radiosurgery.


Assuntos
Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Robótica/métodos , Neoplasias da Coluna Vertebral/cirurgia , Algoritmos , Benchmarking , Humanos , Agências Internacionais , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
18.
Med Phys ; 51(1): 464-475, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37897883

RESUMO

BACKGROUND: Ideally, inverse planning for HDR brachytherapy (BT) should include the pose of the needles which define the trajectory of the source. This would be particularly interesting when considering the additional freedom and accuracy in needle pose which robotic needle placement enables. However, needle insertion typically leads to tissue deformation, resulting in uncertainty regarding the actual pose of the needles with respect to the tissue. PURPOSE: To efficiently address uncertainty during inverse planning for HDR BT in order to robustly optimize the pose of the needles before insertion, that is, to facilitate path planning for robotic needle placement. METHODS: We use a form of stochastic linear programming to model the inverse treatment planning problem. To account for uncertainty, we consider random tissue displacements at the needle tip to simulate tissue deformation. Conventionally for stochastic linear programming, each simulated deformation is reflected by an addition to the linear programming problem which increases problem size and computational complexity substantially and leads to impractical runtime. We propose two efficient approaches for stochastic linear programming. First, we consider averaging dose coefficients to reduce the problem size. Second, we study weighting of the slack variables of an adjusted linear problem to approximate the full stochastic linear program. We compare different approaches to optimize the needle configurations and evaluate their robustness with respect to different amounts of tissue deformation. RESULTS: Our results illustrate that stochastic planning can improve the robustness of the treatment with respect to deformation. The proposed approaches approximating stochastic linear programming better conform to the tissue deformation compared to conventional linear programming. They show good correlation with the plans computed after deformation while reducing the runtime by two orders of magnitude compared to the complete stochastic linear program. Robust optimization of needle configurations takes on average 59.42 s. Skew needle configurations lead to mean coverage improvements compared to parallel needles from 0.39 to 2.94 percentage points, when 8 mm tissue deformation is considered. Considering tissue deformations from 4  to 10 mm during planning with weighted stochastic optimization and skew needles generally results in improved mean coverage from 1.77 to 4.21 percentage points. CONCLUSIONS: We show that efficient stochastic optimization allows selecting needle configurations which are more robust with respect to potentially negative effects of target deformation and displacement on the achievable prescription dose coverage. The approach facilitates robust path planning for robotic needle placement.


Assuntos
Braquiterapia , Neoplasias da Próstata , Procedimentos Cirúrgicos Robóticos , Robótica , Masculino , Humanos , Próstata , Neoplasias da Próstata/radioterapia , Braquiterapia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Agulhas
19.
Radiother Oncol ; 193: 110114, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38309583

RESUMO

AIM: 106Ru eye plaque brachytherapy (BT, interventional radiotherapy) is an eye-preserving treatment for uveal melanoma performed in about 100 clinics worldwide. Despite this relatively low number, there is a considerable variation in clinical practice. In 2022, the BRAPHYQS and Head & Neck and Skin GEC-ESTRO working groups conducted a survey to map the current clinical practice. The survey consisted of a physicist and a physician part. This paper describes the physicist results. However, three physician questions with overlapping interest are included here as well. MATERIALS AND METHODS: The survey questions pertained to commissioning and quality control (QC) of the plaques, treatment planning, radiobiological correction, as well as more general questions on practice improvement. The questions overlapping with the physician survey were related to dose prescription and margins. RESULTS: Sixty-five physicist responses were included. A majority of the centres do not perform an independent measurement of the absorbed dose at reference depth, percentage depth dose (PDD) and off-axis data. A lack of calibration services and suitable equipment are the main reasons. About one third of the centres indicated that they do image based treatment planning. The use of margins and dose prescription showed a large variability, despite the availability of guidelines [1]. Many respondents expressed a strong wish for improvement in a wide range of aspects of clinical practice. CONCLUSION: The physics survey showed a wide variability regarding quality control of the 106Ru sources and treatment planning practice.


Assuntos
Braquiterapia , Melanoma , Humanos , Melanoma/radioterapia , Dosagem Radioterapêutica , Braquiterapia/métodos , Planejamento da Radioterapia Assistida por Computador , Inquéritos e Questionários
20.
Phys Imaging Radiat Oncol ; 27: 100461, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37720460

RESUMO

Background/Purpose: This study determines and compares the geometric setup errors between stereoscopic x-ray and kilo-voltage cone beam CT (CBCT) in phantom tests on a linear accelerator (linac) for image-guided (IG) stereotactic radiotherapy of intracranial tumors. Additionally, dose-volume metrics in the target volumes of the setup errors of CBCT were evaluated. Materials/Methods: A Winston-Lutz- and an anthropomorphic phantom were used. The mean deviation and root mean square error (RMSE) of CBCT and stereoscopic x-ray were compared. Dose-volume metrics of the planning target volume (PTV) and gross target volume (GTV) for CBCT were calculated. Results: The RMSEs in the tests with the Winston-Lutz-Phantom were 0.3 mm, 1.1 mm and 0.3 mm for CBCT and 0.1 mm, 0,1 mm and <0.1 mm for stereoscopic x-ray in the translational dimensions (right-left, anterior-posterior and superior-inferior). The RMSEs in the tests with the anthropomorphic phantom were 0.3 mm, 0.2 mm and 0.1 mm for CBCT and 0.1 mm, 0,1 mm and <0.1 mm for stereoscopic x-ray. The effects on dose-volume metrics of the setup errors of CBCT on the GTV were within 1 % for all considered dose values. The effects on the PTV were within 5 % for all considered dose values. Conclusion: Both IG systems provide high accuracy patient positioning within a submillimeter range. The phantom tests exposed a slightly higher accuracy of stereoscopic x-ray than CBCT. The comparison with other studies with a similar purpose emphasizes the importance of individual IG installation quality assurance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA