Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
J Appl Lab Med ; 9(3): 549-557, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38332638

RESUMO

BACKGROUND: Busulfan is widely used in conditioning regimens to prepare patients for hematopoietic stem cell transplantation. Therapeutic drug monitoring (TDM) is critical due to large inter- and intra-individual variability in busulfan pharmacokinetics, and the risk of adverse consequences of toxicity including hepatic veno-occlusive disease. Busulfan is most commonly measured by liquid chromatography-mass spectrometry (LC-MS/MS), which is not as widely available in clinical laboratories as automated routine clinical chemistry analyzers. The objective was to perform analytical verification of a busulfan immunoassay on the Abbott Alinity c platform. METHODS: The MyCare Oncology busulfan immunoassay was configured as a third-party reagent on the Abbott Alinity c. Imprecision, linearity, sample carryover, and onboard stability of reagent studies were evaluated. The performance of the busulfan immunoassay using the Abbott Alinity c was compared to the Beckman Coulter AU480 using sodium heparinized plasma, as well as to LC-MS/MS using lithium heparinized plasma. RESULTS: The imprecision goal of 8% was met, and linearity within the analytical measurement range of 240 to 1700 ng/mL was verified. Sample carryover was negligible, and the reagents were stable onboard for at least 84 days. The busulfan immunoassay correlated well with LC-MS/MS (slope = 0.949, y-intercept = -7.8 ng/mL, r2 = 0.9935) and the Beckman Coulter AU480 (slope = 1.090, y-intercept = -34.5 ng/mL, r2 = 0.9988). CONCLUSIONS: This study demonstrated successful analytical verification of a busulfan third-party immunoassay on the Abbott Alinity c platform. The ability to perform TDM of busulfan on a routine clinical chemistry analyzer will positively impact turnaround times to improve patient outcomes.


Assuntos
Bussulfano , Monitoramento de Medicamentos , Bussulfano/sangue , Bussulfano/farmacocinética , Humanos , Imunoensaio/métodos , Monitoramento de Medicamentos/métodos , Monitoramento de Medicamentos/instrumentação , Espectrometria de Massas em Tandem , Cromatografia Líquida/métodos , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Reprodutibilidade dos Testes
2.
J Chromatogr A ; 1192(1): 152-6, 2008 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-18405906

RESUMO

A background electrolyte for capillary electrophoresis containing tris(-hydroxymethyl) aminomethane (THAM) and ethanesulfonic acid (ESA) gives excellent efficiency for separation of drug cations with actual theoretical plate numbers as high as 300,000. However, the analyte cations often elute too quickly and consequently offer only a narrow window for separation. The best way to correct this is to induce a reverse electroosmotic flow (EOF) that will spread out the peaks by slowing their migration rates, but this has always been difficult to accomplish in a controlled manner. A new method for producing a variable EOF is described in which a low variable concentration of tributylammonium- or triethylammonium ESA is added to the BGE. The additive equilibrates with the capillary wall to give it a positive charge and thereby produce a controlled opposing EOF. Excellent separations of complex drug mixtures were obtained by this method.


Assuntos
Cátions/isolamento & purificação , Eletroforese Capilar/métodos , Trometamina/análogos & derivados , Acetonitrilas/química , Butilaminas/química , Eletrólitos/química , Trometamina/química
3.
J Chromatogr A ; 1118(1): 62-7, 2006 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-16476436

RESUMO

There is an increasing need to know the concentrations of chromium(III) and (VI) separately rather than only the total chromium content. A method is described for accomplishing this very quickly using only low-cost, portable equipment. Two small, resin-loaded extraction disks are placed one on top of the other in a plastic holder. Then a syringe containing the aqueous sample is attached to the holder and the sample is pushed through the disks. In a matter of seconds, all of the chromium(VI) is retained on the top anion-exchange disk and chromium(III) is extracted by the second cation-exchange disk. The concentrations on each disk are several hundredfold higher than they were in the original sample. The amounts of chromium(III) and (VI) extracted are measured directly on the surface of the respective disks by diffuse reflectance spectroscopy (DRS). Despite the low molar absorptivity of chromium(III) in aqueous solution, the concentration on the upper most layer on the extraction disk is high enough to permit the determination of chromium(III) in samples at the low mg/L range. Chromium(VI) can also be determined at low to sub-mg/L concentrations. A study of the cation-exchange disks was undertaken to compare the performance characteristics of disks containing sulfonated resins and those with iminodiacetate functionality. In addition, data are presented to show the effects of heating the iminodiacetate disks after the initial extraction. The disks were heated in hot water for 15-30 min to complete the slow complexation reaction on the surface.


Assuntos
Cromo/análise , Resinas de Troca Iônica/química , Resinas de Troca Aniônica/química , Calibragem , Resinas de Troca de Cátion/química , Cromatografia por Troca Iônica/instrumentação , Cromatografia por Troca Iônica/métodos , Cromo/química , Cromo/isolamento & purificação , Reprodutibilidade dos Testes , Análise Espectral/instrumentação , Análise Espectral/métodos , Fatores de Tempo
4.
J Chromatogr A ; 1109(1): 86-91, 2006 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-16360162

RESUMO

Novel monolithic disks were prepared via ring opening metathesis polymerization (ROMP) from norborn-2-ene (NBE), a crosslinker, i.e., 1,4,5,8,8a-hexahydro-1,4,4,5,8, exo, endo-dimethanonaphthalene (DMN-H6) and tris(norborn-5-ene-2-ylmethylenoxy)methylsilane, respectively, 2-propanol and toluene (25:25:41:9, all %, w/w) using RuCl2(PCy3)2(CHPh) (Cy=cyclohexyl) as initiator and triphenylphosphine (PPh3) as modulator. Disks 1-2 mm thick were prepared by polymerization in a mold, disks thinner than 1mm were prepared by impregnation of nylon or other porous filters prior to the polymerization step. These disks were evaluated for the preconcentration of iodine and selected organic solutes from dilute aqueous samples by solid-phase extraction (SPE). Quantitative measurement of the extracted solutes was achieved by diffuse-reflectance spectroscopy (DRS) directly on the surface of the disk.


Assuntos
Fracionamento Químico/métodos , Membranas Artificiais , Compostos Bicíclicos com Pontes/química , Heptanos/química , Iodo/análise , Naftalenos/química , Polímeros/síntese química , Silanos/química , Análise Espectral/métodos
5.
J Chromatogr A ; 1118(1): 155-9, 2006 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-16516904

RESUMO

Simple, reliable and sensitive analytical methods to determine the anions, such as fluoride, monofluorophaosphate, glycerophosphate related to anticaries are necessary for basic investigations of anticaries and quality control of dentifrices. A method for the simultaneous determination of organic acids, organic anions and inorganic anions in the sample of commercial toothpaste is proposed. Nine anions (fluoride, chloride, nitrite, nitrate, sulfate, phosphate, monofluorophaosphate, glycerophosphate and oxalic acid) were analyzed by means of ion chromatography using a gradient elution with KOH as mobile phase, IonPac AS18 as the separation column and suppressed conductivity detection. Optimized analytical conditions were further validated in terms of accuracy, precision and total uncertainty and the results showed the reliability of the IC method. The relative standard deviations (RSD) of the retention time and peak area of all species were less than 0.170 and 1.800%, respectively. The correlation coefficients for target analytes ranged from 0.9985 to 0.9996. The detection limit (signal to noise ratio of 3:1) of this method was at low ppb level (<15 ppb). The spiked recoveries for the anions were 96-103%. The method was applied to toothpaste without interferences.


Assuntos
Ânions/análise , Cromatografia por Troca Iônica/métodos , Dentifrícios/química , Glicerofosfatos/análise , Cloretos/análise , Fluoretos/análise , Nitratos/análise , Nitritos/análise , Ácido Oxálico/análise , Fosfatos/análise , Reprodutibilidade dos Testes , Sulfatos/análise , Cremes Dentais/química
6.
J Chromatogr A ; 1118(1): 68-72, 2006 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-16483592

RESUMO

A single-column method for the simultaneous determination of common cations and transition metals in real samples is proposed in this paper. Eleven cations (copper, lithium, sodium, ammonium, potassium, cobalt, nickel, magnesium, calcium, strontium and zinc) were separated and analyzed by means of ion chromatography using an isocratic elution with 2.5 mM methane sulfonic acid and 0.8 mM oxalic acid as mobile phase, IonPac SCS1 (250 mm x 4 mm I.D.) as the separation column and non-suppressed conductor detection. Optimized analytical conditions were further validated in terms of accuracy, precision and total uncertainty and the results showed the reliability of the IC method. The relative standard deviations (RSDs) of the retention time and peak area were less than 0.04 and 1.30%, respectively. The coefficients of determination for cations ranged from 0.9988 to 1.000. The method developed was successfully applied to determination of cations in samples of beer and bottled mineral water. The spiked recoveries for the cations were 94-106%. The method was applied to beer and beverage without interferences.


Assuntos
Cátions/análise , Cromatografia por Troca Iônica/métodos , Metais/análise , Cátions/química , Metais/química , Águas Minerais/análise , Ácido Oxálico/química , Padrões de Referência , Reprodutibilidade dos Testes , Ácidos Sulfônicos/química
7.
J Chromatogr A ; 1085(1): 8-17, 2005 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-16106841

RESUMO

Methods for separation of ions by ion-exchange, ion-pair, and zwitterion ion chromatography share at least one common thread--the induced formation of a cation-anion pair in the stationary phase. Selectivity can be defined as the relative ability of sample ions to form such a pair. Examples are given in anion-exchange chromatography to show the effect of variations in the geometry, bulkiness and polarity of the resin cation on selectivity. The type of resin matrix, the hydrophobic nature of the resin surface and the degree of solvation also affect chromatographic behavior. The selectivity series observed in ion chromatography seems to be best explained by the interplay of two components: electrostatic attraction (ES) and the enforced-pairing (EP) that is brought about by hydrophobic attraction and by water-enforced ion pairing. Selectivity in ion-pair chromatography (IPC) and in zwitterion ion chromatography (ZIC) is affected by both the mobile phase cation and anion. This leads to elution orders for anions that are different from conventional ion-exchange chromatography (IC) of anions where cations are excluded from the stationary phase and have little effect on a separation. The elution order of anions in ZIC is similar to that in IC except for small anions of 2-charge, which are retained more weakly in ZIC. A unique advantage of ZIC is that sample ions can be eluted as ion pairs with pure water as the eluent and a conductivity detector. The mechanism for separation of anions on a zwitterionic stationary phase has been a subject for considerable debate. The available facts point strongly to a partitioning mechanism or a mixed mechanism in which partitioning is dominant with a weaker ion-exchange component.


Assuntos
Cromatografia Líquida/métodos , Íons/química , Cromatografia por Troca Iônica/métodos , Troca Iônica , Resinas de Troca Iônica/química , Solventes/química , Eletricidade Estática , Água/química
8.
J Chromatogr A ; 1085(1): 170-5, 2005 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-16106865

RESUMO

A background electrolyte (BGE) containing a 100 mM concentration of an alkylammonium cation with ethyl, propyl or butyl groups provides an excellent medium for separation of anions by capillary electrophoresis (CE). Two major effects were noted. Use of one of a series of alkylammonium cations in the BGE at a selected pH provides a simple and effective way to vary and control electroosmotic flow (EOF) over a broad range. It is believed that the alkylammonium cations are coated onto the capillary surface through a reversible dynamic equilibrium. Secondly, alkylammonium cations modify the electrophoretic migration of sample anions and the electroosmotic migration of neutral organic analytes by association interaction. This selective interaction results in improved anion separations and permits the simultaneous separation of neutral analytes. The degree of association interaction varies with the bulk and hydrophobicity of the alkylammonium cations. Incorporation of an aliphatic amine salt of moderate molecular weight in the running electrolyte provides a valuable new way to vary the migration times of sample anions and to optimize their resolution. The interactions between alkylammonium cations and sample anions or neutral organics appear to take place entirely within the liquid phase and do not require a polymeric or micellar pseudo phase.


Assuntos
Ânions/análise , Eletroforese Capilar/métodos , Compostos de Amônio Quaternário/química , Cátions/química , Eletrólitos/química , Eletroforese Capilar/instrumentação , Concentração de Íons de Hidrogênio , Reprodutibilidade dos Testes
9.
J Chromatogr A ; 1085(1): 18-22, 2005 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-16106842

RESUMO

New technology is reported here for the synthesis of an effective weak acid-cation exchanger for ion chromatography. Monodisperse macroporous poly(ethylvinylbenzene-co-divinylbezene) (PEVB-DVB) beads of 5 microm diameter were prepared by a two-step swelling and polymerization method. Then carboxyl groups were introduced by polymerization of maleic anhydride with unreacted vinyl groups on the resin beads, followed by hydrolysis of the maleic anhydride groups. A column packed with the carboxylate beads was used to separate alkali and alkaline earth metal ions in a single isocratic run. Separations were found to be better than those with similar resin particles that are simply coated with maleic acid. The columns containing the new particles were 100% compatible with solvents commonly used for HPLC. Additionally, the prepared column was stable and could be used for a long time in a wide range of pH. The column gave good resolution, low detection limits and good repeatability for the separation of common cations. Satisfactory results were also obtained for separations of organic amines and of common cations in rainwater.


Assuntos
Resinas de Troca de Cátion/química , Cátions/química , Cromatografia por Troca Iônica/instrumentação , Poliestirenos/química , Álcalis/análise , Álcalis/isolamento & purificação , Aminas/análise , Aminas/isolamento & purificação , Cátions/análise , Cátions/isolamento & purificação , Cromatografia por Troca Iônica/métodos , Concentração de Íons de Hidrogênio , Metais Alcalinos/análise , Metais Alcalinos/isolamento & purificação , Metais Alcalinoterrosos/análise , Metais Alcalinoterrosos/isolamento & purificação , Tamanho da Partícula , Polímeros/química , Solventes/química , Fatores de Tempo
10.
J Chromatogr A ; 1039(1-2): 3-12, 2004 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-15250395

RESUMO

Ion chromatography as we know it today was built on a foundation of knowledge accumulated over a period of many years. Here, we review some of the outstanding earlier achievements in ion-exchange chromatography. Beginning about 1947. Spedding and Powell at Iowa State published a series of papers describing practical methods for preparative separation of the rare earths by displacement ion-exchange chromatography. The same group then demonstrated the ion-exchange separation of 14N and 15N isotopes in ammonia. Beginning in the 1950s. Kraus and Nelson at Oak Ridge published numerous analytical methods for metal ions based on separation of their chloride, fluoride, nitrate or sulfate complexes by anion chromatography. In the period from about 1960 to 1980 many clever chromatographic methods for metal ion separations were reported by researchers throughout the world and automatic in-line detection was gradually introduced. A truly innovative method by Small, Stevens and Bauman at Dow Chemical Co. marked the birth of modern ion chromatography. Anions, as well as cations, could now be separated quickly and conveniently by a system of suppressed conductivity detection. A method for anion chromatography with non-suppressed conductivity detection was published by Gjerde et al. in 1979. This was followed by a similar method for cation chromatography in 1980. Ion chromatography as we know it today did not just happen. It was built on a solid foundation of knowledge that has accumulated over a period of many years. Revisiting the older ion-exchange chromatography serves not only to pay tribute to some remarkable accomplishments, but it can also be a learning experience. Trends and ideas in science tend to run in repeating cycles. Thus, an awareness of older work may provide inspiration for new research using improved contemporary technology. Selection of milestones is a rather personal matter. I chose to write about subjects of which I came to have a firsthand knowledge during my career. The topics selected are in roughly chronological order and cover the period from about 1945 to 1980. An effort has been made to explain the chemical principles as well as to recount the major accomplishments of the various research projects.


Assuntos
Cromatografia por Troca Iônica/história , Cromatografia por Troca Iônica/métodos , História do Século XX
11.
J Chromatogr A ; 964(1-2): 91-8, 2002 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-12198859

RESUMO

A straight-chain alcohol or diol additive in the mobile phase was used to modify and improve the HPLC separation of organic acids and bases. Incorporation of 2% 1-butanol, 1% 1,2-hexanediol, or 0.25% 1,2-octanediol into an aqueous mobile phase greatly improved the separation of alkane carboxylic acids on a silica C18 column, both in terms of separation time and peak shape. When 1.5% 1-hexanol, 0.09% 1-decanol or 0.01% 1-dodecanol was added to an acetonitrile-water (30:70) mobile phase, much sharper peaks and better resolution were obtained for aromatic bases separated on an underivatized polystyrene-divinylbenzene column. The mobile phase additive is believed to coat the stationary phase surface by a dynamic equilibrium. The coated surface is more hydrophilic and facilitates the efficient partitioning of analytes between the mobile and stationary phases.


Assuntos
Ácidos/isolamento & purificação , Álcalis/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Compostos Orgânicos/química , Espectrofotometria Ultravioleta
12.
J Chromatogr A ; 985(1-2): 359-65, 2003 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-12580504

RESUMO

Columns suitable for use in anion chromatography can be prepared by coating a packed reversed-phase HPLC column (C18 silica or polystyrene particles) with a cationic surfactant. The efficiency is improved dramatically by first coating the column with a nonionic surfactant and then subsequently with the cationic surfactant. The thickness of the first coated layer as well as the chemical structure of the surfactant have a major effect on the column performance. Actual separations are included to demonstrate the convenience and practical use of the coated columns. Using this approach, columns with 12,900 theoretical plates for the 15-cm column (or 86,000 plates/m) were produced, giving well shaped peaks with an average asymmetry factor of 1.09. The coated layers were found to be stable, giving retention times with an average relative standard deviation of 1.6% for 12 consecutive runs.


Assuntos
Cátions/química , Cromatografia Líquida de Alta Pressão/métodos , Tensoativos/química , Cromatografia Líquida de Alta Pressão/instrumentação
13.
J Chromatogr A ; 997(1-2): 21-31, 2003 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-12830873

RESUMO

New findings are reported on simple ways to modify an ordinary HPLC column to obtain efficient ion chromatographic (IC) separations. Permanently coating a column with an ionic surfactant is known to produce an effective column for IC. We now show that incorporation of a nonionic surfactant in the coating, or coating in separate layers, results in a dramatic reduction of ion retention times and gives sharper peaks. Dynamic coating by incorporating a small amount of an alcohol, diol or zwitterion in the aqueous mobile phase permits good separations of alkanecarboxylic acids. A mobile phase containing a quaternary ammonium cation and a zwitterion anion provides excellent separations of common anions on a silica C18 column. An aqueous eluent containing a mixture of a zwitterion 4-(2-hydroxyethyl) acid and methanesulfonic acid can be used in conjunction with a standard cation exchange column. After passing through a membrane suppressor, the mobile phase has a slightly acidic pH, permitting divalent transition metal ions (as well as others) to be detected by conductivity.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia/métodos , Tensoativos , Ânions , Ácidos Carboxílicos/isolamento & purificação , Cátions , Cetilpiridínio , Concentração de Íons de Hidrogênio , Indicadores e Reagentes , Mesilatos , Percloratos , Compostos de Amônio Quaternário , Dióxido de Silício , Compostos de Sódio
14.
J Chromatogr A ; 956(1-2): 139-45, 2002 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-12108644

RESUMO

An ion chromatographic (IC) method is reported for simultaneous determination of total acidity (H+), Ba2+, Ca2+, and Mg2+ in aqueous samples. A standard ODS silica column modified by coating with n-hexadecylphosphocholine was used as the separation column. Water alone was used as the eluent, with conductivity detection of the sample ions. An excess of sodium iodide was added to each sample so that both H+ and divalent cations were always eluted with iodide as the counterion. The elution order was Ba2+, Mg2+, Ca2+, and H+ with H+ being eluted much later than the divalent cations. Acetic acid and several other weak acids could also be separated because all the protons were transposed from acetic acid (HAc) to HI by the sodium iodide. Detection limits for 100 microl injection, S/N=3 were in the low micromolar range for the divalent cations and approximately 0.3 mM for H+/I-. This method was used successfully for simultaneous determination of total acidity, magnesium and calcium in HCl-type of hot-spring water.


Assuntos
Ácidos/química , Cátions Bivalentes/análise , Cromatografia Líquida/métodos , Fosforilcolina/análogos & derivados , Fosforilcolina/química , Sensibilidade e Especificidade
15.
J Chromatogr A ; 1020(2): 259-64, 2003 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-14661749

RESUMO

Inorganic and organic anions can be separated on an ordinary silica C18 column using a mobile phase containing tetrabutylammonium hydroxide (TBAH) and an aminosulfonic acid zwitterion reagent (MOPS). The pH of this eluent is close to 7 and the background conductivity is about 50 microS, which is low enough to permit anion analyte detection by direct conductivity. Linear calibration curves were obtained for the six anions studied and detection limits ranged from 0.075 to 0.15 mg/l (ppm) for the five inorganic anions. The method was applied to the determination of water-soluble anions in aerosol samples at concentrations as low as 0.3 mg/l.


Assuntos
Ânions/isolamento & purificação , Cromatografia Líquida/métodos , Aerossóis , Cátions , Concentração de Íons de Hidrogênio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
J Chromatogr A ; 1039(1-2): 227-33, 2004 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-15250427

RESUMO

At concentrations of 100 mM or higher the chemical nature of both the cation and anion in the background electrolyte (BGE) can be varied to manipulate the migration times of protonated aniline cations. Significant differences were noted with Li+, Na+ and K+ for capillary electrophoretic runs carried out at pH 3. However, much greater differences in migration times were observed at acidic pH values when the BGE contained protonated cations of aliphatic amines. Analyte migration became progressively slower in the series: methylamine, diethylamine, diethylamino ethanol and triethylamine. A major part of this effect was attributed to an opposing electroosmotic flow (EOF) resulting from a positively-charged coating of the capillary surface with the amine cations in the BGE via a dynamic equilibrium. The amine cations also interact in solution with the analyte ions to reduce their electrophoretic mobilities. Migration times of anilines could be varied systematically over a broad range according to the BGE amine cation selected. Excellent separations of seven closely-related anilines were obtained with the new system.


Assuntos
Cátions/análise , Eletroforese Capilar/métodos , Compostos Orgânicos/análise , Sais/química , Concentração de Íons de Hidrogênio
17.
J Chromatogr A ; 997(1-2): 41-50, 2003 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-12830875

RESUMO

We introduce colorimetric solid-phase extraction (C-SPE) for the rapid determination of selected ions. This new technique links the exhaustive concentration of an analyte by SPE onto a membrane disk surface for quantitative measurement with a hand-held diffuse reflectance spectrometer. The concentration/measurement procedure is complete in approximately 1 min and can be performed almost anywhere. This method has been used to monitor iodine and iodide in spacecraft water in the 0.1-5.0 ppm range and silver(I) in the range of 5.0-1000 microg/l. Applications to the trace analysis of copper(II), nickel(II), iron(III) and chromium(VI) are described. Studies on the mechanism of extraction showed that impregnation of the disk with a surfactant as well as a complexing reagent results in uptake of additional water, which markedly improves the extraction efficiency.


Assuntos
Colorimetria/métodos , Íons/análise , Análise Espectral/métodos , Cátions/análise , Cromo/análise , Cobre/análise , Iodetos/análise , Iodo/análise , Ferro/análise , Metais/análise , Níquel/análise , Prata/análise , Água/química
18.
J Chromatogr A ; 942(1-2): 11-32, 2002 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-11822376

RESUMO

One of the problems with capillary electrophoresis is a lack of versatility regarding manipulation of the separation selectivity. A new and potentially universal concept is to introduce an ion-exchange component into a separation so that the migration of analyte ions is influenced by both their electrophoretic mobilities and their chromatographic properties. This may be accomplished by use of capillaries filled with or coated with solid ion-exchange polymers, or by addition of a soluble ionic polymer to the background electrolyte to create a pseudo-stationary phase. While each of these methods achieves the same result, they are not competitive, but rather complementary as the problems associated by one approach are overcome by the others. Recent highlights in the field are used to illustrate the flexibility that this approach provides to electrophoretic separation of ions.


Assuntos
Cromatografia Capilar Eletrocinética Micelar/métodos , Eletroforese Capilar/métodos , Polímeros/química , Resinas de Troca Iônica/química , Íons , Tensoativos/química
19.
J Chromatogr A ; 997(1-2): 127-32, 2003 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-12830884

RESUMO

In this study, an aqueous solution consisting of benzoic acid with low background conductivity and beta-cyclodextrin (beta-CD) of hydrophilic nature and the inclusion effect to benzoic acid were used as eluent for the ion-exclusion chromatographic separation of aliphatic carboxylic acids with different pKa values and hydrophobicity on a polymethacrylate-based weakly acidic cation-exchange resin in the H+ form. With increasing concentration of beta-cyclodextrin in the eluent, the retention times of the carboxylic acids decreased due to the increased hydrophilicity of the polymethacrylate-based cation-exchange resin surface from the adsorption of OH groups of beta-cyclodextrin. Moreover, the eluent background conductivity decreased with increasing concentration of beta-cyclodextrin in 1 mM benzoic acid, which could result in higher sensitivity for conductimetric detection. The ion-exclusion chromatographic separation of carboxylic acids with high resolution and sensitivity was accomplished successfully by elution with a 1 mM benzoic acid-10 mM cyclodextrin solution without chemical suppression.


Assuntos
Ácido Benzoico , Ácidos Carboxílicos/análise , Resinas de Troca de Cátion , Cromatografia por Troca Iônica/métodos , Ciclodextrinas , beta-Ciclodextrinas , Adsorção , Calibragem , Condutividade Elétrica , Concentração de Íons de Hidrogênio , Indicadores e Reagentes , Metanol , Ácidos Polimetacrílicos , Controle de Qualidade , Sensibilidade e Especificidade , Soluções
20.
J Chromatogr A ; 956(1-2): 209-14, 2002 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-12108652

RESUMO

In this preliminary study, a new approach to ion-exclusion chromatography is proposed to overcome the relatively poor conductivity detection response which occurs in ion-exclusion chromatography when acids are added to the eluent in order to improve peak shape. This approach, termed vacancy ion-exclusion chromatography, requires the sample to be used as eluent and a sample of water to be injected onto a weakly acidic cation-exchange column (TSKgel OApak-A). Vacancy peaks for each of the analytes appear at the retention times of these analytes. Highly sensitive conductivity detection is possible and sharp, well-shaped peaks are produced, leading to efficient separations. Retention times were found to be affected by the concentration of the analytes in the eluent, and also by the presence of an organic modifier such as methanol in the eluent. Detection limits for oxalic, formic, acetic, propionic, butyric and valeric acids were 0.1, 0.2, 0.3, 0.3, 0.4 and 0.5 microM, respectively, and linear ranges for some acids extended over two orders of magnitude. Precision values for retention times were 0.21% and for peak areas were <1.90%. The vacancy ion-exclusion chromatography method was found to give detection responses four to 10 times higher than conventional ion-exclusion chromatography using sulfuric acid eluent and two to five times higher than conventional ion-exclusion chromatography using benzoic acid eluent.


Assuntos
Resinas de Troca de Cátion , Cromatografia por Troca Iônica/métodos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA