Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 87(6): 063115, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27370434

RESUMO

An electrostatic cryogenic storage ring, CSR, for beams of anions and cations with up to 300 keV kinetic energy per unit charge has been designed, constructed, and put into operation. With a circumference of 35 m, the ion-beam vacuum chambers and all beam optics are in a cryostat and cooled by a closed-cycle liquid helium system. At temperatures as low as (5.5 ± 1) K inside the ring, storage time constants of several minutes up to almost an hour were observed for atomic and molecular, anion and cation beams at an energy of 60 keV. The ion-beam intensity, energy-dependent closed-orbit shifts (dispersion), and the focusing properties of the machine were studied by a system of capacitive pickups. The Schottky-noise spectrum of the stored ions revealed a broadening of the momentum distribution on a time scale of 1000 s. Photodetachment of stored anions was used in the beam lifetime measurements. The detachment rate by anion collisions with residual-gas molecules was found to be extremely low. A residual-gas density below 140 cm(-3) is derived, equivalent to a room-temperature pressure below 10(-14) mbar. Fast atomic, molecular, and cluster ion beams stored for long periods of time in a cryogenic environment will allow experiments on collision- and radiation-induced fragmentation processes of ions in known internal quantum states with merged and crossed photon and particle beams.

2.
Rev Sci Instrum ; 81(5): 055105, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20515170

RESUMO

We report on the realization and operation of a fast ion beam trap of the linear electrostatic type employing liquid helium cooling to reach extremely low blackbody radiation temperature and residual gas density and, hence, long storage times of more than 5 min which are unprecedented for keV ion beams. Inside a beam pipe that can be cooled to temperatures <15 K, with 1.8 K reached in some locations, an ion beam pulse can be stored at kinetic energies of 2-20 keV between two electrostatic mirrors. Along with an overview of the cryogenic trap design, we present a measurement of the residual gas density inside the trap resulting in only 2 x 10(3) cm(-3), which for a room temperature environment corresponds to a pressure in the 10(-14) mbar range. The device, called the cryogenic trap for fast ion beams, is now being used to investigate molecules and clusters at low temperatures, but has also served as a design prototype for the cryogenic heavy-ion storage ring currently under construction at the Max-Planck Institute for Nuclear Physics.


Assuntos
Transferência de Energia , Congelamento , Íons , Manejo de Espécimes/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
3.
Phys Rev Lett ; 100(19): 193201, 2008 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-18518450

RESUMO

Angular fragment distributions from the dissociative recombination (DR) of HD(+) were measured with well directed monochromatic low-energy electrons over a dense grid of collision energies from 7 to 35 meV, where pronounced rovibrational Feshbach resonances occur. Significant higher-order anisotropies are found in the distributions, whose size varies along energy in a partial correlation with the relative DR rate from fast-rotating molecules. This may indicate a breakdown of the nonrotation assumption so far applied to predict angular DR fragment distributions.

4.
Psychiatr Neurol Med Psychol (Leipz) ; 37(8): 464-71, 1985 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-4059437

RESUMO

In the contribution the recent situation of the therapy-important psychodiagnostic is discribed as characterized through a contradiction. On one hand there's an substantial pressure for an effective treatment, on the other hand we have only a few well developed theoretical models and practical instruments. Three empirical questions in the experience of conflicts are investigated: First the rather few percentage of conscious conflicts as consequence of the substantial unconsciousness from central motives; second the still relative abstract definition of needs, and third problems in diagnostic of the so called personality strukture'. The article is closed with a discussion of some new possibilities of a action-related diagnostic of conflicts and motives.


Assuntos
Transtornos Neuróticos/diagnóstico , Psicoterapia , Adulto , Conflito Psicológico , Feminino , Humanos , Acontecimentos que Mudam a Vida , Masculino , Transtornos Neuróticos/psicologia , Transtornos Neuróticos/terapia , Testes Psicológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA