Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 29(10): 14853-14867, 2021 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-33985198

RESUMO

Mueller matrix polarimetry (MMP) has been demonstrated and recognized as an effective approach to attaining imaging enhancement as well as revealing polarization properties of an imaged sample. Generally, a minimum of 16 combinations of intensity-only measurements involving both linear and circular polarizations are required to completely and accurately determine the 4 × 4 Mueller matrix (MM) and comprehensively describe the polarization properties of the sample. However, broadband circular polarizations (CP) are rather difficult to obtain for design and fabrication limitations in the terahertz region, which poses a challenge to the acquisition of the 4 × 4 MM. In this circumstance, the 3 × 3 MM degradation using only linear polarizations (LP) is preferred and sufficient for characterization of non-depolarizing samples. In this paper, a multi-spectral 3 × 3 MMP system based on the THz time-domain spectroscopy (THz-TDS) is established from 0.1 to 1 THz. The system demonstrated is capable of fulfilling the accurate determination of the 3 × 3 MM. The Mueller matrix polar decomposition (MMPD), modified to be compatible with the MM degradation, is employed to explore the fine details and properties of the sample. By signal post-processing techniques, the MM elements in the time domain are retrieved, and the time dimension reflecting the depth information facilitates the 3D reconstruction of the sample. This work provides a prototype for 3D imaging of biological samples at higher frequencies in the future.

2.
Opt Express ; 26(5): 5281-5291, 2018 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-29529733

RESUMO

We present a reconfigurable, dynamic beam steering holographic metasurface aperture to synthesize a microwave camera at K-band frequencies. The aperture consists of a 1D printed microstrip transmission line with the front surface patterned into an array of slot-shaped subwavelength metamaterial elements (or meta-elements) dynamically tuned between "ON" and "OFF" states using PIN diodes. The proposed aperture synthesizes a desired radiation pattern by converting the waveguide-mode to a free space radiation by means of a binary modulation scheme. This is achieved in a holographic manner; by interacting the waveguide-mode (reference-wave) with the metasurface layer (hologram layer). It is shown by means of full-wave simulations that using the developed metasurface aperture, the radiated wavefronts can be engineered in an all-electronic manner without the need for complex phase-shifting circuits or mechanical scanning apparatus. Using the dynamic beam steering capability of the developed antenna, we synthesize a Mills-Cross composite aperture, forming a single-frequency all-electronic microwave camera.

3.
Sensors (Basel) ; 18(5)2018 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-29757241

RESUMO

Numerous prototypes of computational imaging systems have recently been presented in the microwave and millimeter-wave domains, enabling the simplification of associated active architectures through the use of radiating cavities and metasurfaces that can multiplex signals encoded in the physical layer. This paper presents a new reconstruction technique leveraging the sparsity of the signals in the time-domain and decomposition of the sensing matrix.

4.
Opt Express ; 25(15): 18230-18249, 2017 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-28789312

RESUMO

Computational imaging systems leverage generalized measurements to produce high-fidelity images, enabling novel and often lower cost hardware platforms at the expense of increased processing. However, obtaining full resolution images across a large field-of-view (FOV) can lead to slow reconstruction times, limiting system performance where faster frame rates are desired. In many imaging scenarios, the highest resolution is needed only in smaller subdomains of interest within a scene, suggesting an aperture supporting multiple modalities of image capture with different resolutions can provide a path to system optimization. We explore this concept in the context of millimeter-wave imaging, presenting the design and simulation of a single frequency (75 GHz), multistatic, holographic spotlight aperture integrated into a K-band (17.5-26.5 GHz), frequency-diverse imager. The spotlight aperture - synthesized using an array of dynamically tuned, holographic, metasurface antennas - illuminates a constrained region-of-interest (ROI) identified from a low-resolution image, extracting a high-fidelity image of the constrained-ROI with a minimum number of measurement modes. The designs of both the static, frequency-diverse sub-aperture and the integrated dynamic spotlight aperture are evaluated using simulation techniques developed for large-scale synthetic apertures.

5.
Opt Express ; 25(22): 27488-27505, 2017 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-29092221

RESUMO

We propose a polarimetric microwave imaging technique that exploits recent advances in computational imaging. We utilize a frequency-diverse cavity-backed metasurface, allowing us to demonstrate high-resolution polarimetric imaging using a single transceiver and frequency sweep over the operational microwave bandwidth. The frequency-diverse metasurface imager greatly simplifies the system architecture compared with active arrays and other conventional microwave imaging approaches. We further develop the theoretical framework for computational polarimetric imaging and validate the approach experimentally using a multi-modal leaky cavity. The scalar approximation for the interaction between the radiated waves and the target- often applied in microwave computational imaging schemes-is thus extended to retrieve the susceptibility tensors, and hence provides additional information about the targets. Computational polarimetry has relevance for existing systems in the field that extract polarimetric imagery, and particular for ground observation. A growing number of short-range microwave imaging applications can also notably benefit from computational polarimetry, particularly for imaging objects that are difficult to reconstruct when assuming scalar estimations.

6.
J Opt Soc Am A Opt Image Sci Vis ; 34(5): A22-A36, 2017 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28463331

RESUMO

We investigate the application of dynamic metasurface antennas (DMAs) to synthetic aperture radar (SAR) systems. Metasurface antennas can generate a multitude of tailored electromagnetic waveforms from a physical platform that is low-cost, lightweight, and planar; these characteristics are not readily available with traditional SAR technologies, such as phased arrays and mechanically steered systems. We show that electronically tuned DMAs can generate steerable, directive beams for traditional stripmap and spotlight SAR imaging modes. This capability eliminates the need for mechanical gimbals and phase shifters, simplifying the hardware architecture of a SAR system. Additionally, we discuss alternative imaging modalities, including enhanced resolution stripmap and diverse pattern stripmap, which can achieve resolution on par with spotlight, while maintaining a large region-of-interest, as possible with stripmap. Further consideration is given to strategies for integrating metasurfaces with chirped pulse RF sources. DMAs are poised to propel SAR systems forward by offering a vast range of capabilities from a significantly improved physical platform.

7.
Opt Express ; 24(15): 16760-76, 2016 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-27464130

RESUMO

Computational imaging modalities support a simplification of the active architectures required in an imaging system and these approaches have been validated across the electromagnetic spectrum. Recent implementations have utilized pseudo-orthogonal radiation patterns to illuminate an object of interest-notably, frequency-diverse metasurfaces have been exploited as fast and low-cost alternative to conventional coherent imaging systems. However, accurately measuring the complex-valued signals in the frequency domain can be burdensome, particularly for sub-centimeter wavelengths. Here, computational imaging is studied under the relaxed constraint of intensity-only measurements. A novel 3D imaging system is conceived based on 'phaseless' and compressed measurements, with benefits from recent advances in the field of phase retrieval. In this paper, the methodology associated with this novel principle is described, studied, and experimentally demonstrated in the microwave range. A comparison of the estimated images from both complex valued and phaseless measurements are presented, verifying the fidelity of phaseless computational imaging.

8.
Nat Commun ; 14(1): 6249, 2023 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-37803018

RESUMO

The reaction-diffusion principle imagined by Alan Turing in an attempt to explain the structuring of living organisms is leveraged in this work for the procedural synthesis of radiating metasurfaces. The adaptation of this morphogenesis technique ensures the growth of anisotropic cellular patterns automatically arranged to satisfy local electromagnetic constraints, facilitating the radiation of waves controlled in frequency, space, and polarization. Experimental validations of this method are presented, designing morphogenetic metasurfaces radiating far-field circularly polarized beams and generating a polarization-multiplexed hologram in the radiative near-field zone. The exploitation of morphogenesis-inspired models proves particularly well suited for solving generative design problems, converting global physical constraints into local interactions of simulated chemical reactants ensuring the emergence of self-organizing meta-atoms.

9.
Sci Rep ; 11(1): 3545, 2021 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-33574392

RESUMO

Recent demonstrations have shown that frequency-diverse computational imaging systems can greatly simplify conventional architectures developed for imaging by transferring constraints into the digital layer. Here, in order to limit the latency and processing burden involved in image reconstruction, we propose to truncate insignificant principal components of the sensing matrix that links the measurements to the scene to be imaged. In contrast to recent work using principle component analysis to synthesize scene illuminations, our generic approach is fully unsupervised and is applied directly to the sensing matrix. We impose no restrictions on the type of imageable scene, no training data is required, and no actively reconfigurable radiating apertures are employed. This paper paves the way to the constitution of a new degree of freedom in image reconstructions, allowing one to place the performance emphasis either on image quality or latency and computational burden. The application of such relaxations will be essential for widespread deployment of computational microwave and millimeter wave imagers in scenarios such as security screening. We show in this specific context that it is possible to reduce both the processing time and memory consumption with a minor impact on the quality of the reconstructed images.

10.
Sci Rep ; 9(1): 16704, 2019 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-31723176

RESUMO

We present a frequency-diverse based direction of arrival (DoA) estimation technique for millimetre-wave (mmW) 5G channel sounding. Frequency-diversity enables the creation of spatially incoherent radiation masks to encode the plane-wave signals incident on the radar aperture using a single antenna. Leveraging the frequency-diversity concept, spatial information of the plane-wave projections on the radar aperture is retrieved, resulting in high-fidelity DoA estimations by means of a simple Fourier transform operation applied to the retrieved plane-wave projection patterns. It is demonstrated that using the frequency-diversity concept, DoA estimation can be achieved through a simple frequency sweep, compressing the incoming plane-waves into a single channel through the transfer function of the radar aperture. This results in a significant simplification in the system hardware, requiring only a single antenna to achieve DoA estimation. It is also shown that the proposed technique can simultaneously detect the DoA information for multiple sources with a diffraction limited resolution.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA