1.
J Shoulder Elbow Surg ; 26(8): 1348-1354, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28601487

RESUMO

BACKGROUND: The available literature on the use of a cementless total elbow arthroplasty (TEA) design and its results are limited. This clinical study reports the outcome of the cementless Discovery elbow system. METHODS: Patients were operated on by a single surgeon between 2007 and 2014. Nineteen patients (20 elbows) were available for review, 2 women (1 bilateral TEA) and 17 men. The age of the patients ranged from 27 to 75 years (mean, 48 years). The mean follow-up was 61.8 months (range, 12-156 months). Patients were assessed for range of motion, pain, and satisfaction level. Outcome scores included the Mayo Elbow Performance Score, the Liverpool Elbow Score, and the 12-Item Short Form Health Survey (version 1). Radiographs were reviewed to evaluate for loosening. RESULTS: The mean Mayo Elbow Performance Score was 77.25, and the mean Liverpool Elbow Score was 6.76. The mean flexion range was 123°, and the mean extension lag was 35°. The mean pronation was 59°, and the mean supination was 58°. On radiologic evaluation, there were no signs of loosening; however, in 2 cases, nonprogressive radiolucent lines were observed. No signs of infection were detected at final follow-up, and no elbows were revised. More than 90% of patients were satisfied with the overall outcome. CONCLUSION: The cementless TEA seems to be a reliable option for treatment of varying elbow diseases. Long-term results are needed to assess the survivorship of this design.


Assuntos
Artroplastia de Substituição do Cotovelo/instrumentação , Articulação do Cotovelo/fisiopatologia , Articulação do Cotovelo/cirurgia , Adulto , Idoso , Artroplastia de Substituição do Cotovelo/efeitos adversos , Articulação do Cotovelo/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Dor/etiologia , Satisfação do Paciente , Pronação , Radiografia , Amplitude de Movimento Articular , Estudos Retrospectivos , Supinação , Resultado do Tratamento
2.
J Shoulder Elbow Surg ; 24(6): 965-71, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25535020

RESUMO

HYPOTHESIS AND BACKGROUND: The purpose of this study was to compare the accuracy of patient-specific guides for total shoulder arthroplasty (TSA) with traditional instrumentation in arthritic cadaver shoulders. We hypothesized that the patient-specific guides would place components more accurately than standard instrumentation. MATERIALS AND METHODS: Seventy cadaver shoulders with radiographically confirmed arthritis were randomized in equal groups to 5 surgeons of varying experience levels who were not involved in development of the patient-specific guidance system. Specimens were then randomized to patient-specific guides based off of computed tomography scanning, standard instrumentation, and anatomic TSA or reverse TSA. Variances in version or inclination of more than 10° and more than 4 mm in starting point were considered indications of significant component malposition. RESULTS: TSA glenoid components placed with patient-specific guides averaged 5° of deviation from the intended position in version and 3° in inclination; those with standard instrumentation averaged 8° of deviation in version and 7° in inclination. These differences were significant for version (P = .04) and inclination (P = .01). Multivariate analysis of variance to compare the overall accuracy for the entire cohort (TSA and reverse TSA) revealed patient-specific guides to be significantly more accurate (P = .01) for the combined vectors of version and inclination. Patient-specific guides also had fewer instances of significant component malposition than standard instrumentation did. CONCLUSION: Patient-specific targeting guides were more accurate than traditional instrumentation and had fewer instances of component malposition for glenoid component placement in this multi-surgeon cadaver study of arthritic shoulders. Long-term clinical studies are needed to determine if these improvements produce improved functional outcomes.


Assuntos
Artrite/cirurgia , Artroplastia de Substituição/métodos , Cavidade Glenoide , Articulação do Ombro/cirurgia , Artrite/diagnóstico por imagem , Artroplastia de Substituição/instrumentação , Cadáver , Cavidade Glenoide/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Radiografia , Articulação do Ombro/diagnóstico por imagem , Tomógrafos Computadorizados
3.
Eur J Appl Physiol ; 114(1): 177-85, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24178819

RESUMO

PURPOSE: Despite increasing interest in bio-impedance analysis (BIA) for estimation of segmental skeletal muscle mass (SMM), published results have not been entirely convincing. Furthermore, a better understanding of the relationship between muscle strength and SMM will be useful in interpreting outcomes of physical/training interventions particularly in groups with diverse body sizes (e.g. men vs women). This study aimed to measure SMM in the upper body (upper extremity and torso), to determine its correlation with muscle strength and to examine the effects of gender on muscle strength-muscle mass relationship. METHODS: Segmental (upper extremity and torso) SMM and muscle strength in five distinct shoulder planes (forward flexion, abduction in scapular plane, abduction in coronal plane, internal and external rotation) were measured in 45 healthy participants (22 males, 23 females) with mean age 30.3 years. Statistical analysis included independent t tests, Pearson correlation, and multiple regression analysis. RESULTS: Men and women differed significantly in body mass (BMI: 25.9 ± 4.3 vs 23 ± 3.6) and SMM (p < 0.01). A strong relationship correlation was found between the five shoulder strength measurements and upper extremity SMM (r = 0.66-0.80, p < 0.01), which was not affected by gender. There was a significant gender difference (p < 0.01) in absolute shoulder strength, but not after normalisation to the SMM. CONCLUSION: BIA-estimated SMM of upper extremity and torso was highly correlated with upper extremity (shoulder) strength independent of gender. SMM may, therefore, be useful for the normalisation of muscle strength allowing size-independent comparisons of muscle strength in individuals with diverse physical characteristics.


Assuntos
Força Muscular , Músculo Esquelético/fisiologia , Adulto , Impedância Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/anatomia & histologia , Tamanho do Órgão , Fatores Sexuais , Tronco/anatomia & histologia , Tronco/fisiologia , Extremidade Superior/anatomia & histologia , Extremidade Superior/fisiologia
4.
J Shoulder Elbow Surg ; 22(3): 312-7, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23312819

RESUMO

BACKGROUND: Responsiveness and floor and ceiling effect are important parameters for evaluating the sensitivity of an outcome instrument in detecting the changes in the clinical condition of patients after an intervention as well as evaluating the content validity of the instrument. The aim of this prospective observational study was to assess these parameters for the Liverpool Elbow Score (LES) in total elbow replacement (TER). METHODS: The study included 121 cemented TER cases with linked elbow prosthesis (Discovery Elbow, Biomet Orthopaedics, Swindon, UK) for various conditions, including inflammatory arthritis, noninflammatory arthritis, trauma, and loosening. The proportion of patients with the lowest score (0 points; floor effect) and maximum score (10 points; ceiling effect) was checked preoperatively and 1 year postoperatively. Distribution-based methods (effect size [ES], standardized response mean [SRM], Guyatt responsiveness ratio [GRR]) and anchor-based methods (receiver operating characteristic [ROC] curve and Spearman correlation coefficient) were used to assess responsiveness. Patient satisfaction after TER was used as an external anchor. RESULTS: Patients were a mean age of 63 years (range, 20-86 years). Large ES (1.64), SRM (1.25), and GRR (1.69) were found during the follow-up period. Area under the ROC curve was 0.71 (95% confidence interval, 0.56-0.87; P = .03). There was significant positive correlation (Spearman correlation coefficient, 0.35; P = .004) between changes in LES and satisfaction level. LES showed no floor and ceiling effect preoperatively and at 1 year postoperatively. CONCLUSION: LES is a responsive measure and has no floor and ceiling effect. LEVEL OF EVIDENCE: This encourages its use as an outcome instrument for TER. Basic Science Study, Development or Validation of Outcome Instruments.


Assuntos
Artroplastia de Substituição do Cotovelo , Articulação do Cotovelo/cirurgia , Indicadores Básicos de Saúde , Artropatias/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Resultado do Tratamento , Adulto Jovem , Lesões no Cotovelo
5.
J Shoulder Elbow Surg ; 22(10): 1352-8, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23562291

RESUMO

BACKGROUND: Published data on the outcome of Copeland shoulder resurfacing arthroplasty (CSRA) are limited. This observational case series study reports the functional and radiological outcome of CSRA during a mean follow-up of 4 years and highlights the correlation between key outcome measures. METHODS: One-hundred two consecutive patients with osteoarthritis (OA-47.1%), rheumatoid arthritis (RA-40.2%), rotator cuff arthropathy (RCA-8.8%), and avascular necrosis (AVN-3.9%) underwent CSRA. The outcome assessment included pain and satisfaction, physical limitation, Oxford Shoulder score (OSS), Constant score (CS), and SF-12. Imaging was reviewed for glenoid morphology (Walch classification) and humeral head (HH) migration. RESULTS: Highest patient satisfaction and lowest pain levels were related to the primary pathology with AVN best followed by OA, RA, and with RCA having the poorest outcome. Comparing the two largest groups the CS was significantly higher in OA (61 ± 21.3) than RA (44 ± 20.5). OSS showed a significant correlation with CS and physical subscale of SF-12. Walch type A (67.6%) and HH migration (47%) were the commonest radiographic observations. OSS, CS, pain, and satisfaction were significantly different between migration and nonmigration groups. CONCLUSION: The CSRA resulted in satisfactory outcome in many patients. AVN and OA were associated with the best and RCA with the poorest results. The CSRA was associated with glenoid erosion and HH migration particularly in RCA. CSRA remains an option in the treatment of arthritic conditions of the shoulder but its future use may be limited to younger patients where implanting a glenoid may be regarded as problematic.


Assuntos
Artroplastia de Substituição/métodos , Cabeça do Úmero/cirurgia , Osteoartrite/cirurgia , Articulação do Ombro/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Cabeça do Úmero/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteoartrite/diagnóstico por imagem , Osteoartrite/fisiopatologia , Satisfação do Paciente , Desenho de Prótese , Radiografia , Amplitude de Movimento Articular , Estudos Retrospectivos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
6.
J Shoulder Elb Arthroplast ; 6: 24715492221118765, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36035594

RESUMO

Background: Stemless shoulder arthroplasty was developed to restore the glenohumeral centre of rotation without violation of the humeral shaft. It allows the preservation of humeral bone stock. Complications related to stem malalignment and periprosthetic fractures can be avoided. Patient and methods: This is a prospective observational study that reports outcomes of 46 patients who received stemless shoulder arthroplasty "Comprehensive Nano implant ®." The series includes Group (A): 30 anatomic and one hemiarthroplasty. Group (B): 15 reverse stemless replacement. Functional outcomes were assessed by visual analog score (VAS), satisfaction, range motion, Constant score, and American Shoulder and Elbow Score (ASES). Results: The mean follow-up was 40.4 ± 12 months (range, 24 months to 60 months). Group (A): VAS and satisfaction improved by 5.3 and 67.5 points respectively. Constant score significantly improved from 28.5 ± 14.5 to 62.5 ± 23 P = <0.001. The radiological assessment showed the mean centre of rotation (COR) deviation was 2.8 ± 1.9 mm. 27% of patients have COR discrepancy of more than 4 mm. In Group (B), patients reported a significant improvement in VAS, Satisfaction, and ASES P = 0.002, 0.002, and 0.003, respectively.Complications include shoulder pain with progressive loss of movements, aseptic loosening early subscapularis rupture, glenohumeral dislocations, and humeral component migration. Conclusion: Anatomic Stemless total shoulder arthroplasty offers acceptable results and improvement of overall functional outcomes.

7.
Knee ; 37: 47-59, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35679783

RESUMO

BACKGROUND: Gene expression in healthy synovium remains poorly characterised. Thus, synovial functional activity changes associated with osteoarthritis (OA) are difficult to define. This study sought to identify differentially expressed genes (DEG) of end-stage OA and assess the influence of OA risk factors on these DEG. METHODS: Anonymised patient clinical data and x-ray images were analysed. Osteoarthritic and non-osteoarthritic patients with soft tissue or traumatic knee injuries were matched for body mass index (BMI) and sex. Tissue samples were partitioned for immunocytochemistry (IHC) and microarray analysis. Multiple bioinformatics applications were utilised to determine changes in functional and canonical pathway activation. RESULTS: Age, disease-modifying injections and hypertension were confounding factors between patient groups. Inflammation was present in all tissues. Cartilage debris and inflammatory aggregates were noted in many osteoarthritic patient tissues. IHC and expression analyses revealed upregulation of synoviolin 1 (SYVN1) in osteoarthritic synovium. Significant differential expression was noted in 2084 genes. Osteoarthritic synovium displayed a significant upregulation of 95% of DEG coding for proteins, relative to non-osteoarthritic synovium tissues. Unfolded protein response (UPR)-related genes were upregulated in osteoarthritic synovium; gene expression of molecules within many canonical pathways including protein ubiquitination and UPR pathways was modified by BMI and sex. CONCLUSIONS: The synovium of all three pathologies exhibited elements of an inflammatory response. Cartilage debris, age, BMI and sex influence DEG of osteoarthritic synovium. UPR pathway is the top deregulated canonical pathway identified in osteoarthritic synovium regardless of BMI and sex, while typical OA-associated inflammatory and matrix gene responses were minimal.


Assuntos
Cartilagem Articular , Osteoartrite , Cartilagem , Cartilagem Articular/metabolismo , Expressão Gênica , Humanos , Osteoartrite/genética , Osteoartrite/metabolismo , Fatores de Risco , Membrana Sinovial/metabolismo
8.
J Shoulder Elb Arthroplast ; 6: 24715492221075449, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35669616

RESUMO

Aims: Patient-specific instrumentation (PSI) in primary shoulder arthroplasty has been studied; results supported the positive impact of the PSI on the glenoid positioning. Nevertheless, no clinical outcomes have been reported. We compare the clinical outcomes of primary reverse total shoulder arthroplasty using PSI versus the standard methods. Methods: Fifty-three patients with full records and a minimum of 24-months follow-up were reviewed, 35 patients received primary standard RSTA, and 18 patients received primary PSI RSTA. All patients were operated on in a single center. The median follow-up was 46 months (53 months in the standard group vs 39 months in the PSI group). Results: There was an overall significant post-operative improvement in the whole cohort (P< 0.05). The standard group had more deformed glenoids (B2, B3, C&D) and significantly low preoperative constant score and forward flexion (P=0.02 & 0.034). Compared to the PSI group (all were A1, A2, B1 &one type D), there were no statistically significant differences in any clinical outcome postoperatively. PSI neither prolonged the waiting time to surgery (P=0.693) nor the intraoperative time (P=0.962). Radiologically, PSI secured a higher percentage of optimum baseplate position and screw anchorage; however, no statistical correlation was found. Conclusion: In this series, both groups achieved comparable good outcomes. PSI did not achieve significantly better clinical outcomes than Standard after primary RSTA. Yet comparison has some limitations. PSI did not negatively impact the waiting time or the surgical time.

9.
Data Brief ; 42: 108082, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35392626

RESUMO

Degradation of articular cartilage is the defining feature of end-stage osteoarthritis (OA) with osteophytes, subchondral sclerosis, malalignment and joint space narrowing being additional indicators of advanced disease. Obesity, older age and female gender are OA risk factors. Differing degrees of synovitis are observed in OA, soft tissue and traumatic injuries of the knee. The synovium is also subject to systemic, enhanced lipids and inflammatory mediators characteristic of obesity. Synovial cellular composition changes specific to OA and associated with its handling of cartilage debris are unclear. Triangulation of data from three knee pathologies was used to highlight findings pertaining to OA compared to non-OA. OA patient data was compared to non-OA from knee ligament and tibial frature patients at surgery. Knee pathology, gender and BMI informed patient identification. Once consented, patient inclusion and characterisation utilised data from clinical assessments, blood tests, function scores, and radiological imaging, scores and intraoperative assessment. Intra-operative synovial tissues from the same site and processed identically underpins in-depth analyses and comparisons of histopathological images from these different knee pathologies. This supports the identification of distinct changes in the cellular composition of the knee synovium characteristic of OA. This data underpins a better understanding of OA pathogenesis and disease progression vital for the design of targeted therapeutics. The tissue and cell data include detailed results from the semi-quantitative synovitis score established by Krenn and observational data for morphological features such as cartilage debris inclusion, inflammatory cells aggregate and infiltration. This histopathological data is presented in the context of detailed clinical and functional information. This data and the holistic study design can be used as a foundation for the multifactorial collection and analysis of clinical data from OA patients, OA severity measures, tissue immuno-histology and synovial inflammation analysis to underpin the details and comparisons needed in further studies into OA and its treatment globally.

10.
PeerJ ; 8: e8740, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32587790

RESUMO

BACKGROUND: Type 2 diabetes mellitus (T2DM) had been reported to be associated with tendinopathy. However, the underlying mechanisms of diabetic tendinopathy still remain largely to be discovered. The purpose of this study was to develop insulin resistance (IR) model on primary human tenocytes (hTeno) culture with tumour necrosis factor-alpha (TNF-α) treatment to study tenocytes homeostasis as an implication for diabetic tendinopathy. METHODS: hTenowere isolated from human hamstring tendon. Presence of insulin receptor beta (INSR-ß) on normal tendon tissues and the hTeno monolayer culture were analyzed by immunofluorescence staining. The presence of Glucose Transporter Type 1 (GLUT1) and Glucose Transporter Type 4 (GLUT4) on the hTeno monolayer culture were also analyzed by immunofluorescence staining. Primary hTeno were treated with 0.008, 0.08, 0.8 and 8.0 µM of TNF-α, with and without insulin supplement. Outcome measures include 2-[N-(7-nitrobenz-2-oxa-1,3-diazol-4-yl) amino]-2-deoxy-d-glucose (2-NBDG) assay to determine the glucose uptake activity; colourimetric total collagen assay to quantify the total collagen expression levels; COL-I ELISA assay to measure the COL-I expression levels and real-time qPCR to analyze the mRNA gene expressions levels of Scleraxis (SCX), Mohawk (MKX), type I collagen (COL1A1), type III collagen (COL3A1), matrix metalloproteinases (MMP)-9 and MMP-13 in hTeno when treated with TNF-α. Apoptosis assay for hTeno induced with TNF-α was conducted using Annexin-V FITC flow cytometry analysis. RESULTS: Immunofluorescence imaging showed the presence of INSR-ß on the hTeno in the human Achilles tendon tissues and in the hTeno in monolayer culture. GLUT1 and GLUT4 were both positively expressed in the hTeno. TNF-α significantly reduced the insulin-mediated 2-NBDG uptake in all the tested concentrations, especially at 0.008 µM. Total collagen expression levels and COL-I expression levels in hTeno were also significantly reduced in hTeno treated with 0.008 µM of TNF-α. The SCX, MKX and COL1A1 mRNA expression levels were significantly downregulated in all TNF-α treated hTeno, whereas the COL3A1, MMP-9 and MMP-13 were significantly upregulated in the TNF-α treated cells. TNF-α progressively increased the apoptotic cells at 48 and 72 h. CONCLUSION: At 0.008 µM of TNF-α, an IR condition was induced in hTeno, supported with the significant reduction in glucose uptake, as well as significantly reduced total collagen, specifically COL-I expression levels, downregulation of candidate tenogenic markers genes (SCX and MKX), and upregulation of ECM catabolic genes (MMP-9 and MMP-13). Development of novel IR model in hTeno provides an insight on how tendon homeostasis could be affected and can be used as a tool for further discovering the effects on downstream molecular pathways, as the implication for diabetic tendinopathy.

11.
Int J Biochem Cell Biol ; 126: 105800, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32673644

RESUMO

OBJECTIVES: To compare mechanobiological response of synovial fibroblasts (SFb) from OA patient cohorts under mechanical load and inflammatory stressors for better understanding of SFb homeostatic functions. METHODS: Primary SFb isolated from knee synovium of OA obese (OA-ob:SFb), OA-pre-obese (OA-Pob:SFb), non-OA arthroscopic (scope:SFb), and non-OA arthroscopic with cartilage damage (scope-CD:SFb) were exposed to OA-conditioned media (OACM), derived from OA obese (OA-ob:CM), OA-pre-obese (OA-Pob:CM), and mechanical stretch at either 0 %, 6 % or 10 % for 24 h. Differences in the mRNA levels of genes involved in extracellular matrix production, inflammation and secretory activity were measured. RESULTS: Despite the significant BMI differences between the OA-ob and OA-Pob groups, OA-Pob has more patients with underlying dyslipidaemia, and low-grade synovitis with higher levels of secreted proteins, CXCL8, COL4A1, CCL4, SPARC and FGF2 in OA-Pob:CM. All primary SFb exhibited anti-proliferative activity with both OA-CM. Mechanical stretch stimulated lubricin production in scope:SFb, higher TGFß1 and COL1A1 expressions in scope-CD:SFb. OA-Pob:CM stimulated greater detrimental effects than the OA-ob:CM, with higher pro-inflammatory cytokines, IL1ß, IL6, COX2 and proteases such as aggrecanases, ADAMTS4 and ADAMTS5, and lower ECM matrix, COL1A1 expressions in all SFb. OA-ob:SFb were unresponsive but expressed higher pro-inflammatory cytokines under OA-Pob:CM treatment. CONCLUSION: Both mechanical and inflammatory stressors regulate SFb molecular functions with heterogeneity in responses that are dependent on their pathological tissue of origins. While mechanical stretch promotes a favorable effect with enhanced lubricin production in scope:SFb and TGFß1 and COL1A1 in scope-CD:SFb, the presence of excessively high OA-associated inflammatory mediators in OA-Pob:CM, predominantly SPARC, CXCL8 and FGF2 drive all SFb regardless of pathology, towards greater pro-inflammatory activities.


Assuntos
Fibroblastos/patologia , Osteoartrite/patologia , Estresse Mecânico , Membrana Sinovial/patologia , Adulto , Fenômenos Biomecânicos , Estudos de Casos e Controles , Feminino , Humanos , Inflamação/complicações , Masculino , Pessoa de Meia-Idade , Osteoartrite/complicações , Osteoartrite/metabolismo , Adulto Jovem
12.
Sci Rep ; 9(1): 6271, 2019 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-31000752

RESUMO

The pathophysiology of Stanmore Classification Polar type II/III shoulder instability is not well understood. Functional Magnetic Resonance Imaging was used to measure brain activity in response to forward flexion and abduction in 16 patients with Polar Type II/III shoulder instability and 16 age-matched controls. When a cluster level correction was applied patients showed significantly greater brain activity than controls in primary motor cortex (BA4), supramarginal gyrus (BA40), inferior frontal gyrus (BA44), precentral gyrus (BA6) and middle frontal gyrus (BA6): the latter region is considered premotor cortex. Using voxel level correction within these five regions a unique activation was found in the primary motor cortex (BA4) at MNI coordinates -38 -26 56. Activation was greater in controls compared to patients in the parahippocampal gyrus (BA27) and perirhinal cortex (BA36). These findings show, for the first time, neural differences in patients with complex shoulder instability, and suggest that patients are in some sense working harder or differently to maintain shoulder stability, with brain activity similar to early stage motor sequence learning. It will help to understand the condition, design better therapies and improve treatment of this group; avoiding the common clinical misconception that their recurrent shoulder dislocations are a form of attention-seeking.


Assuntos
Encéfalo/diagnóstico por imagem , Instabilidade Articular/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ombro/diagnóstico por imagem , Adulto , Encéfalo/patologia , Mapeamento Encefálico , Feminino , Humanos , Instabilidade Articular/patologia , Masculino , Córtex Motor/diagnóstico por imagem , Córtex Motor/patologia , Lobo Parietal/diagnóstico por imagem , Lobo Parietal/patologia , Córtex Pré-Frontal/diagnóstico por imagem , Córtex Pré-Frontal/patologia , Ombro/patologia
13.
PLoS One ; 14(2): e0211800, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30735521

RESUMO

The shoulder relies heavily on coordinated muscle activity for normal function owing to its limited osseous constraint. However, previous studies have failed to examine the sophisticated interrelationship between all muscles. It is essential for these normal relationships to be defined as a basis for understanding pathology. Therefore, the primary aim of the study was to investigate shoulder inter-muscular coordination during different planes of shoulder elevation. Twenty healthy subjects were included. Electromyography was recorded from 14 shoulder girdle muscles as subjects performed shoulder flexion, scapula plane elevation, abduction and extension. Cross-correlation was used to examine the coordination between different muscles and muscle groups. Significantly higher coordination existed between the rotator cuff and deltoid muscle groups during the initial (Pearson Correlation Coefficient (PCC) = 0.79) and final (PCC = 0.74) stages of shoulder elevation compared to the mid-range (PCC = 0.34) (p = 0.020-0.035). Coordination between the deltoid and a functional adducting group comprising the latissimus dorsi and teres major was particularly high (PCC = 0.89) during early shoulder elevation. The destabilising force of the deltoid, during the initial stage of shoulder elevation, is balanced by the coordinated activity of the rotator cuff, latissimus dorsi and teres major. Stability requirements are lower during the mid-range of elevation. At the end-range of movement the demand for muscular stability again increases and higher coordination is seen between the deltoid and rotator cuff muscle groups. It is proposed that by appreciating the sophistication of normal shoulder function targeted evidence-based rehabilitation strategies for conditions such as subacromial impingement syndrome or shoulder instability can be developed.


Assuntos
Músculo Deltoide/fisiopatologia , Eletromiografia , Movimento , Síndrome de Colisão do Ombro/fisiopatologia , Articulação do Ombro/fisiopatologia , Músculos Superficiais do Dorso/fisiopatologia , Adulto , Feminino , Humanos , Masculino , Amplitude de Movimento Articular , Manguito Rotador/fisiopatologia
14.
Lancet ; 370(9591): 949-56, 2007 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-17869635

RESUMO

BACKGROUND: After hip replacement surgery, prophylaxis following discharge from hospital is recommended to reduce the risk of venous thromboembolism. Our aim was to assess the oral, direct thrombin inhibitor dabigatran etexilate for such prophylaxis. METHODS: In this double-blind study, we randomised 3494 patients undergoing total hip replacement to treatment for 28-35 days with dabigatran etexilate 220 mg (n=1157) or 150 mg (1174) once daily, starting with a half-dose 1-4 h after surgery, or subcutaneous enoxaparin 40 mg once daily (1162), starting the evening before surgery. The primary efficacy outcome was the composite of total venous thromboembolism (venographic or symptomatic) and death from all causes during treatment. On the basis of the absolute difference in rates of venous thromboembolism with enoxaparin versus placebo, the non-inferiority margin for the difference in rates of thromboembolism was defined as 7.7%. Efficacy analyses were done by modified intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00168818. FINDINGS: Median treatment duration was 33 days. 880 patients in the dabigatran etexilate 220 mg group, 874 in the dabigatran etexilate 150 mg group, and 897 in the enoxaparin group were available for the primary efficacy outcome analysis; the main reasons for exclusion in all three groups were the lack of adequate venographic data. The primary efficacy outcome occurred in 60 (6.7%) of 897 individuals in the enoxaparin group versus 53 (6.0%) of 880 patients in the dabigatran etexilate 220 mg group (absolute difference -0.7%, 95% CI -2.9 to 1.6%) and 75 (8.6%) of 874 people in the 150 mg group (1.9%, -0.6 to 4.4%). Both doses were thus non-inferior to enoxaparin. There was no significant difference in major bleeding rates with either dose of dabigatran etexilate compared with enoxaparin (p=0.44 for 220 mg, p=0.60 for 150 mg). The frequency of increases in liver enzyme concentrations and of acute coronary events during the study did not differ significantly between the groups. INTERPRETATION: Oral dabigatran etexilate was as effective as enoxaparin in reducing the risk of venous thromboembolism after total hip replacement surgery, with a similar safety profile.


Assuntos
Anticoagulantes/uso terapêutico , Artroplastia de Quadril , Benzimidazóis/uso terapêutico , Enoxaparina/uso terapêutico , Complicações Pós-Operatórias/prevenção & controle , Piridinas/uso terapêutico , Tromboembolia/prevenção & controle , Trombose Venosa/prevenção & controle , Idoso , Anticoagulantes/efeitos adversos , Benzimidazóis/efeitos adversos , Dabigatrana , Método Duplo-Cego , Enoxaparina/efeitos adversos , Feminino , Hemorragia/induzido quimicamente , Humanos , Masculino , Pessoa de Meia-Idade , Piridinas/efeitos adversos
15.
Arthroscopy ; 24(1): 39-45, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18182200

RESUMO

PURPOSE: The purpose of this study was to review the results of distal biceps tendon repair via suture anchors through a single anterior incision. METHODS: This is a retrospective review of 17 patients (18 repairs) treated for complete distal biceps tendon rupture between 1998 and 2005 by use of G4 Superanchors (DePuy Mitek, Raynham, MA) in our unit. The length of follow-up was 14 to 70 months (mean, 45 months). RESULTS: There was a mean loss of 5.3 degrees (range, 0 degrees to 50 degrees ; SD, 14.12) of extension when compared with the uninjured side. Of the 17 patients, 6 achieved full extension when compared with the uninvolved elbow. The mean loss of flexion was 6.2 degrees (range, 0 degrees to 15 degrees; SD, 6.11). There was a mean loss of 11.0 degrees of pronation (range, 0 degrees to 30 degrees; SD, 11.34) and 6.4 degrees of supination (range, 0 degrees to 45 degrees; SD, 17.45). Flexion in supination strength measured by a handheld dynamometer was 82.1% of that of the injured side (range, 59% to 102%; SD, 11.26). There were two complications in our series: transient superficial radial nerve palsy in one case and heterotopic ossification in the other. The mean Disabilities of the Arm, Shoulder and Hand score was 14.45 (range, 0 to 55.17; SD, 4.76). Six months after surgery, all patients but one returned to their preinjury levels of activity and employment. CONCLUSIONS: Our study shows that repair of distal biceps tendon ruptures via suture anchors is safe and yields clinically objective and functional results comparable to measurements in the other, uninjured extremity. LEVEL OF EVIDENCE: Level IV, therapeutic case series.


Assuntos
Procedimentos Ortopédicos/instrumentação , Âncoras de Sutura , Traumatismos dos Tendões/cirurgia , Adulto , Braço , Humanos , Masculino , Amplitude de Movimento Articular , Estudos Retrospectivos , Ruptura , Técnicas de Sutura , Traumatismos dos Tendões/fisiopatologia
16.
Acta Orthop Belg ; 74(5): 596-601, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19058691

RESUMO

It has been reported that the effectiveness of arthroscopic procedures in terms of preventing recurrent dislocation has not matched that from open techniques. Also little is known about how these knots behave when exposed to physiological loading following repair. This study presents the development of a practical tool to allow surgeons to test the quality of their arthroscopic knots and allow them to make choices with regard to knot configuration and suture material. This study uses an apparatus to model the repair of a Bankart lesion. Ten examples of the Duncan loop and SMC knots were tied using PDS, Ethibond, Panacryl and Fibrewire. An arthroscopic knotting technique was used. Reverse slippage occurring during the tying process was recorded. Each knot was then left for 12 hours under loads equivalent to a Bankart repair and the subsequent reverse slippage was recorded. After initial passing of the Duncan loop and after passing of locking hitches the sutures were ranked inversely to size of suture loop (resistance to slippage). Only Fibrewire showed a significant difference (5.7 +/- 1.03 mm to 5.66 +/- 0.5 mm; p <0.05). After 12 hrs, some evidence of reverse slippage was noted, especially with Fibrewire (5.66 +/- 0.5 mm--significant p <0.05). The SMC knot showed generally inferior results. In this study using arthroscopic techniques, Fibrewire performed less well than other materials.


Assuntos
Artroscopia , Luxações Articulares/cirurgia , Suturas , Humanos , Prevenção Secundária , Fatores de Tempo
17.
J Electromyogr Kinesiol ; 38: 136-142, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29245114

RESUMO

Muscle fatigue affecting glenohumeral and/or scapular muscles is suggested as one of the contributing factors to the development of subacromial impingement syndrome (SAIS). Nonetheless, the fatigability of shoulder girdle muscles in association with the pathomechanics of SAIS has not been reported. This study aimed to measure and compare fatigue progression within the shoulder girdle musculature of patients and healthy controls. 75 participants including 39 patients (20 females; 19 males) and 36 healthy controls (15 females; 21 males) participated in the study. Study evaluated the progression of muscle fatigue in 15 shoulder girdle muscles by means of surface and fine-wire EMG during submaximal contraction of four distinct movements (abduction, flexion, internal and external rotation). Shoulder strength, subjective pain experience (McGill Pain Questionnaire), and psychological status (Hospital Anxiety and Depression Scale) were also assessed. The results were compared between patient and control groups according to the gender. Despite marked fatigue observed in the majority of muscles particularly during flexion and abduction at 90°, overall results indicated a lower tendency of fatigue progression in the impingement group across the tests (p < 0.05 - p < 0.001). Shoulder Strength, pain experience, and psychological status were significantly different between the two groups (P < .05). Lower tendency to fatigue progression in the impingement group can be attributed to the presence of fear avoidance and pain-related muscle inhibition, which in turn lead to adaptations in motor programme to reduce muscle recruitment and activation. The significantly higher levels of pain experience and anxiety/depression in the impingement group further support this proposition.


Assuntos
Fadiga Muscular , Músculo Esquelético/fisiopatologia , Síndrome de Colisão do Ombro/fisiopatologia , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contração Muscular
18.
Clin J Pain ; 23(6): 482-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17575487

RESUMO

OBJECTIVES: First to compare pain and functional disability in tennis elbow (TE) patients with healthy controls. Second, to evaluate the relationship between the 2 major psychologic factors (anxiety and depression) and TE. METHODS: Sixteen TE patients were recruited from 46 consecutive attendees at an upper limb clinic: inclusion criteria were lateral epicondyle tenderness, pain with resisted wrist and middle finger extension and at least 3 months localized lateral elbow pain. Sixteen healthy controls with no upper limb problem were recruited from students and staff. Participants were given 4 questionnaires, together with instructions for completion: Disabilities of the Arm, Shoulder, and Hand, Patient-Rated Forearm Evaluation Questionnaire, Patient-Rated Wrist Evaluation Questionnaire, and Hospital Anxiety and Depression Scale. The independent t test was used to compare the total and subscale scores between the groups. RESULTS: Significantly higher scores were found in TE for pain and function subscales and also total score for Disabilities of the Arm, Shoulder, and Hand, Patient-Rated Forearm Evaluation Questionnaire, and Patient-Rated Wrist Evaluation Questionnaire. For Hospital Anxiety and Depression Scale, both anxiety and depression subscales (P<0.001) and the total score (P<0.01) were significantly higher in TE. According to the anxiety and depression subscales, 55% and 36% of patients, respectively, were classified as probable cases (score >11). DISCUSSION: TE patients showed markedly increased pain and functional disability. Significantly elevated levels of depression and anxiety pointed out the importance of psychologic assessment in TE patients. In the development of supportive and treatment strategies, we suggest the combination of "upper limb" and "psychologic" assessment tools.


Assuntos
Avaliação da Deficiência , Dor/etiologia , Cotovelo de Tenista/fisiopatologia , Cotovelo de Tenista/psicologia , Adulto , Idoso , Ansiedade/psicologia , Doença Crônica , Interpretação Estatística de Dados , Depressão/fisiopatologia , Depressão/psicologia , Medo/psicologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dor/fisiopatologia , Escalas de Graduação Psiquiátrica , Inquéritos e Questionários
19.
J Shoulder Elbow Surg ; 16(3 Suppl): S33-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17174113

RESUMO

This randomized controlled trial compares 2 mobilization regimens after shoulder hemiarthroplasty for acute 3- and 4-part fractures. The aim was to establish whether the length of immobilization plays a role in the functional outcome, tuberosity healing, and subsequent range of motion. The same prosthesis and surgical technique were used. We recruited 59 patients into the study; 31 were randomized to early (2 weeks) mobilization and 28 to late (6 weeks) mobilization. Greater tuberosity migration was assessed with a series of radiographs, and the functional outcome was assessed with the Constant Shoulder Assessment and Oxford shoulder scores. Of the patients, 49 (mean age, 70 years) met the inclusion criteria and were followed up for 12 months. Greater tuberosity migration occurred in 3 cases in the early mobilization group and once in the late mobilization group (P > .10). There was no significant difference in the Constant Shoulder Assessment and Oxford scores between the 2 groups. Although there was a decreased incidence of tuberosity migration in the group undergoing late mobilization, this was not statistically significant.


Assuntos
Artroplastia de Substituição/métodos , Fraturas do Ombro/reabilitação , Fraturas do Ombro/cirurgia , Adulto , Idoso , Artroplastia de Substituição/efeitos adversos , Feminino , Consolidação da Fratura , Humanos , Masculino , Pessoa de Meia-Idade , Modalidades de Fisioterapia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Fatores de Tempo
20.
Case Rep Orthop ; 2017: 9307259, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29234550

RESUMO

Melorheostosis is a rare, nonhereditary, benign, mesenchymal condition of unknown aetiology affecting the bones and surrounding tissues. A male patient complaining of left shoulder pain, swelling, and mildly limited range of motion has an exclusive combination of the classic dripping wax lesion in the scapula and the myositis ossificans-like lesion in the deltoid muscle; this combination is the first to be reported in the shoulder. Both lesions showed typical findings of melorheostosis in radiographs, CT, MRI, and bone scan. This case has a stationary course over the follow-up period, and no specific treatment is needed in due course.

SELEÇÃO DE REFERÊNCIAS