Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 146
Filtrar
1.
Circ J ; 87(8): 1103-1111, 2023 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-37258218

RESUMO

BACKGROUND: Recently, destination therapy (DT) was approved in Japan, and patients ineligible for heart transplantation may now receive durable left ventricular assist devices (LVADs). Several conventional risk scores are available, but a risk score that is best to select optimal candidates for DT in the Japanese population remains unestablished.Methods and Results: A total of 1,287 patients who underwent durable LVAD implantation and were listed for the Japanese registry for Mechanically Assisted Circulatory Support (J-MACS) were eligible for inclusion. Finally, 494 patients were assigned to the derivation cohort and 487 patients were assigned to the validation cohort. According to the time-to-event analyses, J-MACS risk scores were newly constructed to predict 3-year mortality rate, consisting of age, history of cardiac surgery, serum creatinine level, and central venous pressure to pulmonary artery wedge pressure ratio >0.71. The J-MACS risk score had the highest predictability of 3-year death compared with other conventional scores in the validation cohort, including HeartMate II risk score and HeartMate 3 risk score. CONCLUSIONS: We constructed the J-MACS risk score to estimate 3-year mortality rate after durable LVAD implantation using large-scale multicenter Japanese data. The clinical utility of this scoring to guide the indication of DT should be validated in the next study.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Dados de Saúde Coletados Rotineiramente , Fatores de Risco , Resultado do Tratamento , Estudos Retrospectivos
2.
Artif Organs ; 47(11): 1742-1751, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37578196

RESUMO

BACKGROUND: Pulmonary complications often occur in patients receiving veno-arterial extracorporeal membrane oxygenation (VA ECMO). However, the prognostic impact of lung damage has not been fully elucidated. METHODS: This single-center retrospective observational study targeted patients with cardiogenic shock who received VA ECMO between 2012 and 2021. This study included 65 patients who underwent chest computed tomography (CT) on VA ECMO, followed by escalation to central mechanical circulatory support (MCS) with left ventricular venting. The average density of lung CT images was measured using region-of-interest methods, and the primary endpoint was 180-day all-cause death after escalation to the central MCS. RESULTS: Twenty-two patients (34%) developed 180-day all-cause death. According to the Cox regression analysis, age (hazard ratio [HR], 1.08; 95% confidence interval [CI], 1.03-1.14; p = 0.001), ischemic etiology (HR, 5.53; 95% CI, 2.09-14.62; p < 0.001), duration of VA ECMO support (HR, 1.19; 95% CI, 1.00-1.40; p = 0.045), and lung CT density (≥ -481 Hounsfield unit [HU]) (HR, 6.33; 95% CI, 2.26-17.72; p < 0.001) were independently associated with all-cause death. Receiver operating characteristic curve analysis determined that lung CT density ≥ -481 HU is an optimal cutoff value for predicting all-cause death (area under the curve [AUC], 0.72). The 180-day overall survival rate for patients with high lung CT density (≥ -481 HU) was significantly lower than that for those with low lung CT density (< -481 HU) (44.4% vs. 81.6%, respectively, p = 0.002). CONCLUSIONS: Higher lung CT density could be a useful predictor of death in patients with VA ECMO requiring central MCS escalation.


Assuntos
Oxigenação por Membrana Extracorpórea , Choque Cardiogênico , Humanos , Prognóstico , Choque Cardiogênico/diagnóstico por imagem , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Oxigenação por Membrana Extracorpórea/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Pulmão/diagnóstico por imagem
3.
Circ J ; 86(12): 1950-1958, 2022 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-35786688

RESUMO

BACKGROUND: The objective of this study is to investigate the effect of preoperative diabetes on all-cause mortality and major postoperative complications among patients with continuous-flow left ventricular assist device (LVAD) by using data from a national database.Methods and Results: The 545 study patients who underwent primary HeartMateII implantation between 2013 and 2019 were divided into 2 groups according to their diabetes mellitus (DM) status; patients with DM (n=116) and patients without DM (n=429). First, the on-device survival and incidence of adverse events were evaluated. Second, after adjusting for patients' backgrounds, the change of laboratory data in the 2 groups were compared. Overall, on-device survival at 1, 2, and 3 years was almost equivalent between the 2 groups; it was 95%, 94%, and 91% in patients without DM, and 93%, 91%m and 91% in patients with DM (P=0.468) The incidence of adverse events was similar between 2 groups of patients, except for driveline exit site infection in the adjusted cohort. Cox proportional hazards regression analysis revealed younger age (HR: 0.98 (95% confidence interval (CI): 0.97-0.99, P=0.001) and presence of DM (HR: 1.83 (95% CI: 1.14-2.88), P=0.016) as significant predictors of driveline infection. Laboratory findings revealed no differences between groups throughout the periods. CONCLUSIONS: The clinical results after LVAD implantation in DM patients were comparable with those in non-DM patients, except for the driveline exit site infection.


Assuntos
Diabetes Mellitus , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Japão/epidemiologia , Resultado do Tratamento , Estudos Retrospectivos
4.
Biol Pharm Bull ; 45(4): 452-459, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35370269

RESUMO

The aim of this study was to investigate whether low-dose valganciclovir (VGCV) prophylaxis for cytomegalovirus (CMV) infection increased the risk of developing neutropenia in heart transplant recipients (HTRs). Forty-three HTRs receiving VGCV were divided into two groups: those who received VGCV prophylaxis (n = 22) and those who did not (n = 21). Neutropenia was defined as an absolute neutrophil count ˂1500/µL and was monitored for approximately one year post-transplantation. In the prophylaxis group, 77.3% (17/22) of HTRs experienced neutropenia, which was significantly higher than that in the no prophylaxis group (42.9% [9/21], p = 0.031). No significant differences in the duration of VGCV administration and cumulative dose up to the first neutropenia episode were observed between the groups. Meanwhile, the cumulative dose of mycophenolate mofetil was significantly higher in the prophylaxis group than in the no prophylaxis group (p = 0.018); the daily maintenance dose and regularly measured area under the concentration-time curve (AUC) of mycophenolic acid did not significantly differ between groups. In conclusion, the risk of developing neutropenia was higher in HTRs receiving low-dose VGCV prophylaxis than it was in those not receiving prophylaxis, probably not attributed to dosing period and cumulative dose of VGCV until the onset of neutropenia.


Assuntos
Transplante de Coração , Neutropenia , Antivirais/uso terapêutico , Ganciclovir/efeitos adversos , Humanos , Neutropenia/induzido quimicamente , Neutropenia/tratamento farmacológico , Neutropenia/prevenção & controle , Medição de Risco , Valganciclovir
5.
J Artif Organs ; 25(3): 223-230, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35022936

RESUMO

Sleep-disordered breathing (SDB) is associated with an increased risk of adverse events in patients with heart failure (HF); however, its impact in patients implanted with a left ventricular assist device (LVAD) remains unclear. We aimed to investigate the prevalence of SDB in patients with LVAD and its impact on their clinical outcomes. Fifty consecutive patients with LVAD who underwent portable sleep monitoring between September 2017 and April 2018 were prospectively enrolled, and they were followed up for 170 ± 36 days. According to their respiratory disturbance indexes (RDIs), they were categorized into the SDB group (RDI ≥ 15, n = 12) and the non-SDB group (RDI < 15, n = 38). The incidence of adverse events during the follow-up period was investigated after enrollment. Multivariate logistic regression analysis revealed significant differences in SDB in LVAD-implanted patients in terms of the logarithmic transformation brain natriuretic peptide (BNP) values (p = 0.005). The optimal BNP cut-off value for SDB prediction in LVAD-implanted patients was 300 pg/mL (sensitivity: 58.3%, specificity: 94.7%). During follow-up, ventricular tachyarrhythmias (VTas) occurred significantly more frequently in the SDB group (4 [33%] vs. 2 [5%] patients, p = 0.02); Atrial tachyarrhythmia (ATa) also tended to occur more frequently in the SDB group (2 [25%] vs. 2 [2%] patients, p = 0.07). SBD was prevalent in 24% of the LVAD-implanted patients with advanced HF. Furthermore, SDB was significantly associated with high BNP levels and was also potentially associated with subsequent incidence of VTa in patients with LVAD.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Síndromes da Apneia do Sono , Taquicardia Ventricular , Humanos , Incidência
6.
J Artif Organs ; 25(3): 214-222, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34866164

RESUMO

A bridging strategy from extracorporeal life support (ECLS) is effective in salvage and a bridge to recovery or to a durable left ventricular assist device (LVAD) for acute refractory heart failure. However, the correlation of this strategy with adverse events after durable LVAD implantation has not been fully investigated. This study enrolled 158 consecutive patients who had either the HeartMate II or HeartMate 3 and were implanted for bridge-to-transplantation. These devices were implanted as the primary mechanical support device in 115 patients, whereas the remaining 43 underwent LVAD implantation as the bridge from central ECLS. The primary study endpoint was all-cause mortality and cerebrovascular accidents (CVAs) after durable LVAD implantation, and the secondary endpoints were adverse events. Overall survival was not significantly different between the two groups. In contrast, the probability of CVAs was significantly greater in the bridge group than in the primary group (probability of CVAs, P = 0.002; log-rank test). In Cox multivariate logistic regression analysis, a bridge from central ECLS was an independent predictive factor of CVAs (hazard ratio 4.27, 95% confidence interval 1.43-12.8; P = 0.0095). Patients who are bridged from central ECLS are more frequently complicated by CVAs compared with those who undergo primary implantation of a durable LVAD, but survival is not significantly different between the two groups. A bridge from central ECLS is an independent predictive factor of CVAs post-implantation of an LVAD.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Humanos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
7.
Kyobu Geka ; 75(1): 21-28, 2022 Jan.
Artigo em Japonês | MEDLINE | ID: mdl-35249073

RESUMO

BACKGROUND: Size-mismatched heart transplantation( HTx) is associated with a risk of stenosis of the caval anastomosis site or low cardiac output syndrome. We developed a modified bicaval anastomosis technique( mBCAT) that achieved an adjustable caval anastomosis to compensate for the size mismatch. This study clarified clinical outcomes of HTx with mBCAT technique according to the degree of the size mismatch. METHODS AND RESULTS: This study consisted of 130 adult patients who underwent HTx with the mBCAT during a 22-year period and were followed up for at least 1 year. The cohort was divided into three groups according to the donor-to-recipient body weight ratio:<0.8, undersized group (n=19);0.8 ~1.3, size-matched group( n=89);and >1.3, oversized group( n=22). The undersized, size-matched, and oversized groups showed no significant differences in the rate of mild or worse tricuspid regurgitation on echocardiography at 1 month [ 1( 5.3%), 8( 9.0%), and 1( 4.6%), respectively;p=0.683] or the survival rate at 10 years( 100%, 96%, and 95%, respectively;p=0.452). The right heart catheter study revealed no pressure gradient across the orifices of both cavae in any patient. Additionally, the cardiac index immediately post-HTx was low in the undersized group, but improved over time in all groups, achieving the comparable value at 6 and 12 months post-HTx. CONCLUSIONS: The mBCAT prevented caval anastomosis-related complications in size-mismatched HTx and achieved excellent hemodynamics regardless of donor size.


Assuntos
Transplante de Coração , Insuficiência da Valva Tricúspide , Adulto , Anastomose Cirúrgica/métodos , Tamanho Corporal , Ecocardiografia , Transplante de Coração/métodos , Hemodinâmica , Humanos , Doadores de Tecidos
8.
Circ J ; 85(10): 1906-1917, 2021 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-34433758

RESUMO

Destination therapy (DT) is the indication to implant a left ventricular assist device (LVAD) in a patient with stage D heart failure who is not a candidate for heart transplantation. The implantable LVAD has been utilized in Japan since 2011 under the indication of bridge to transplant (BTT). After almost 10 year lag, DT has finally been approved and reimbursed in May 2021 in Japan. To initiate the DT program in Japan, revision of the LVAD indication from BTT is necessary. Also, in-depth discussion of caregiver issues as well as end-of-life care is indispensable. For that purpose, we assembled a DT committee of multidisciplinary members in August 2020, and started monthly discussions via web-based communication during the COVID-19 pandemic. This is a summary of the consensus reached after 6 months' discussion, and we have included as many relevant topics as possible. Clinical application of DT has just started, and we are willing to revise this consensus to meet the forthcoming issues raised during real-world clinical experience.


Assuntos
COVID-19/epidemiologia , Consenso , Insuficiência Cardíaca/terapia , Transplante de Coração , Coração Auxiliar , Pandemias , SARS-CoV-2 , Insuficiência Cardíaca/epidemiologia , Humanos , Japão/epidemiologia
9.
Circ J ; 85(9): 1460-1468, 2021 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-33867408

RESUMO

BACKGROUND: Implantable left ventricular assist devices (LVAD) have improved quality of life and survival in patients with advanced heart failure. However, LVAD-specific infections and predicting which patients will develop infections remain challenging. This study investigated whether changes in body mass index (BMI) during hospitalization following LVAD implantation are associated with LVAD-specific infections within 1 year of implantation.Methods and Results:Patients (n=135) undergoing LVAD implantation were retrospectively divided into 2 groups based on changes in BMI from LVAD implantation to discharge: those with and without decreases in BMI. Each group was further subdivided according to baseline albumin concentrations (high [>3.7 g/dL] and low [≤3.7 g/dL]). Twenty patients developed LVAD-specific infections within 1 year. Receiver operating characteristic curve analysis resulted in a ∆BMI cut-off of less than -0.128 kg/m2. In multivariate analysis, younger patients and those with decreases in BMI had significantly higher rates of LVAD-specific infection (P=0.010 and P=0.035, respectively). LVAD-specific infection rates were significantly higher for patients with low albumin and decreases in BMI than for patients with low albumin but no decrease in BMI. CONCLUSIONS: Decreases in BMI during hospitalization after LVAD implantation and younger age were independently associated with LVAD-specific infection within 1 year. Strict patient management may be needed to avoid decreases in BMI during hospitalization after LVAD implantation, particularly in patients with low baseline albumin concentrations.


Assuntos
Coração Auxiliar , Índice de Massa Corporal , Coração Auxiliar/efeitos adversos , Humanos , Incidência , Qualidade de Vida , Estudos Retrospectivos
10.
Pacing Clin Electrophysiol ; 44(6): 1126-1129, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33521993

RESUMO

Left ventricular assist device (LVAD) therapy is increasingly used in patients with end-stage heart failure. However, LVADs are associated with challenges, especially in the presence of a cardiac implantable electronic device. Although a leadless pacemaker (PM), the Micra™ Transcatheter Pacing System, can be used with LVADs, data regarding HeartMate 3™ LVAD are limited. In this report, we present a patient with a HeartMate 3™ LVAD who underwent successful leadless PM implantation after the removal of an infected cardiac resynchronization therapy defibrillator.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Marca-Passo Artificial , Sarcoidose/terapia , Idoso , Eletrocardiografia , Mapeamento Epicárdico , Feminino , Fluoroscopia , Insuficiência Cardíaca/fisiopatologia , Humanos , Desenho de Prótese , Sarcoidose/fisiopatologia
11.
Int J Clin Pharmacol Ther ; 59(8): 566-571, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34085636

RESUMO

OBJECTIVE: Amphotericin B (AMPH-B) is used to prevent opportunistic infections associated with immunosuppressive therapy after heart transplantation (HTx), while the blood concentrations of tacrolimus (TAC) are carefully controlled. Although AMPH-B has the potential to inhibit TAC metabolism in in vitro studies, its interaction with clinically used AMPH-B oral suspension has not been investigated. In the present study, we examined whether oral AMPH-B therapy influences the pharmacokinetics of TAC in HTx patients. MATERIALS AND METHODS: A retrospective study was performed at the National Cerebral and Cardiovascular Center in Japan. All patients with HTx enrolled in the study received standard triple-drug immunosuppression therapy including the regular release of TAC, mycophenolate mofetil, and prednisolone as well as prophylactic therapy with AMPH-B oral suspension. Patient characteristics and clinical laboratory data were collected from the electronic medical record system. Blood concentrations of TAC were used for pharmacokinetic analysis. RESULTS: A total of 14 patients were enrolled in the study. There were no statistically significant differences in the variables except for serum creatinine levels and eGFR before and after discontinuation of oral AMPH-B therapy. The dose and trough concentrations of TAC and the area under the time-concentration curve and apparent oral clearance calculated from its concentrations were not influenced by discontinuation of AMPH-B treatment. CONCLUSION: The prophylactic treatment with AMPH-B oral suspension did not influence the pharmacokinetics of TAC and was demonstrated as a safe and easy method to prevent early post-HTx fungal infection.


Assuntos
Transplante de Coração , Tacrolimo , Anfotericina B , Humanos , Imunossupressores/efeitos adversos , Estudos Retrospectivos
12.
J Artif Organs ; 24(2): 191-198, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33420874

RESUMO

Aortic insufficiency (AI) is known to associate with a persistently closed aortic valve during continuous-flow ventricular assist device support. Some devices carry an intermittent low-speed (ILS) function, which facilitates aortic valve opening, but whether this function prevents AI is unknown. In this study, the Jarvik 2000 device, which is programmed to reduce the pump speed each minute for 8 s, was chosen to examine this potential effect. Prospectively collected data of 85 heart transplant-eligible Jarvik 2000 recipients who met the study criteria (no pre-existing AI and aortic valve surgery) were retrospectively analyzed for the incidence, correlating factors, and clinical outcomes of de novo AI. All data were provided by the Japanese Registry for Mechanically Assisted Circulatory Support. De novo AI occurred in 58 patients, 23 of whom developed at least moderate AI during a median support duration of 23.5 months. Freedom from moderate or greater AI was 84.4%, 66.1% and 60.2% at 1, 2 and 3 years, respectively. Multivariate analyses revealed that progressive AI was correlated with decreased pulse pressure after implantation (hazard ratio 1.060, 95% confidence interval 1.001-1.127, p = 0.045). No correlation was found for mortality or other adverse events, including stroke, bleeding, infection, pump failure, hemolysis, and readmission. The benefit of the Jarvik 2000's current ILS mode against AI appears to be minimal. However, in this limited cohort where all recipients underwent implantation as a bridge to transplantation, the impact of de novo progressive AI on other clinical adversities was also minimal.


Assuntos
Insuficiência da Valva Aórtica/prevenção & controle , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Adulto , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/etiologia , Feminino , Seguimentos , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar/efeitos adversos , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Fatores de Tempo
13.
J Artif Organs ; 24(2): 265-268, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32940802

RESUMO

Aortic insufficiency (AI) is an important adverse event in patients with continuous-flow (CF) left ventricular assist device (LVAD) support. AI is often progressive, resulting in elevated 2-year morbidity and mortality. The effectiveness of echocardiographic ramp studies in patients with AI has been unclear. Here, we describe a patient with a CF-LVAD implant who underwent aortic valve replacement (AVR), following assessment of AI using a hemodynamic ramp test with simultaneous echocardiography and right heart catheterization (RHC). The patient was a 21-year-old man with cardiogenic shock due to acute myocarditis, who underwent HeartWare CF-LVAD (HVAD) implantation. Heart failure persisted despite increased doses of diuretics and inotrope, as well as an increased HVAD pump rate. HVAD monitoring revealed a correlation between increased HVAD pump rate and flow at each speed step. A hemodynamic ramp test with simultaneous transthoracic echocardiography and RHC revealed a significant discrepancy between HVAD pump flow and cardiac output (CO) at each speed step; moreover, pulmonary capillary wedge pressure remained high. Therefore, the patient underwent AVR. Subsequently, his low CO symptoms disappeared and inotropes were successfully discontinued. A postoperative hemodynamic ramp test revealed that AVR had successfully closed the loop of blood flow and reduced the discrepancy between HVAD pump flow and CO, thereby increasing CO. The patient was then discharged uneventfully. In conclusion, a hemodynamic ramp test with simultaneous echocardiography and RHC was useful for the evaluation of the causal relationship between AI and low CO, and for selection of surgical treatment for AI in a patient with CF-LVAD.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Ecocardiografia/métodos , Testes de Função Cardíaca/métodos , Coração Auxiliar , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/fisiopatologia , Débito Cardíaco/fisiologia , Hemodinâmica/fisiologia , Humanos , Masculino , Função Ventricular Esquerda/fisiologia , Adulto Jovem
14.
Circ J ; 84(12): 2198-2204, 2020 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-33148939

RESUMO

BACKGROUND: The bridge-to-bridge (BTB) strategy, a conversion to durable left ventricular assist device (LVAD) after stabilization using surgical temporary mechanical circulatory supports for a couple of months, is not uncommon in Japan. However, its effect on clinical outcomes in comparison with a primary durable LVAD implantation strategy remains unknown.Methods and Results:Data of 837 consecutive patients (median age 45, 73% males) who underwent durable LVAD implantation as BTB (n=168) or primary implant (n=669) between April 2011 and April 2019 were retrospectively reviewed from the prospective multicenter Japanese mechanically assisted circulatory support registry. The BTB group was younger and had comparable end-organ function, better hemodynamic profile, and longer operative time compared with the primary implant group at baseline. The 3-year survival was 80% vs. 87% (P=0.007) for the BTB and primary implant groups respectively, with greater observed rates of stroke and infection as the predominant causes of death. The BTB strategy was independently associated with increased 3-year mortality (hazard ratio 2.69 [1.43-5.07], P=0.002) in addition to other significant risk factors. CONCLUSIONS: The BTB cohort had comparable baseline characteristics to the primary implant cohort at the time of durable LVAD conversion, but had lower 3-year survival. Detailed analysis clarifying the causality of this finding should improve outcomes with the BTB strategy.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Feminino , Insuficiência Cardíaca/terapia , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
15.
Circ J ; 84(11): 1949-1956, 2020 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-32999142

RESUMO

BACKGROUND: Continuous-flow left ventricular assist device (CF-LVAD) substantially improves survival in endstage heart failure patients. However, bleeding complications are common after CF-LVAD implantation and in some cases, re-exploration for bleeding is needed. We aimed to investigate the incidence, timing, and risk factors of bleeding requiring re-exploration after CF-LVAD implantation.Methods and Results:We retrospectively reviewed 162 consecutive patients (age 43±13 years, 71% men) who underwent CF-LVAD implantation (HeartMateII 119, Jarvik2000 15, HVAD 13, EVAHEART 10, DuraHeart 5) from January 2012 to June 2019. During follow-up [median 662 days, interquartile range (IQR) 364-1,116 days], 35 (21.6%) experienced re-exploration for bleeding. The median timing of re-exploration was 6 (IQR 1-10) days. In the multivariate logistic regression analysis, postoperative platelet count was an independent predictor for re-exploration for bleeding after CF-LVAD implantation (per 104/µL: odds ratio 0.83, 95% confidence interval 0.74-0.93, P=0.002). Patients who experienced re-exploration for bleeding had a significantly worse survival rate than patients who did not (at 4 years, 73.6% vs. 90.1%, P=0.039). CONCLUSIONS: Re-exploration for bleeding is prevalent after CF-LVAD implantation, especially in patients with low postoperative platelet counts. As bleeding requiring re-exploration is associated with poor prognosis, risk stratification using the postoperative platelet count may be beneficial for these patients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Hemorragia , Adulto , Feminino , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Hemorragia/epidemiologia , Hemorragia/etiologia , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos
16.
Circ J ; 84(7): 1090-1096, 2020 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-32461539

RESUMO

BACKGROUND: Bridge-to-decision (BTD) devices providing temporary mechanical circulatory support should be introduced to patients with advanced heart failure. This study evaluated the effectiveness and safety of a BTD device comprising an innovative extracorporeal continuous-flow temporary ventricular assist device (VAD) driven by a novel hydrodynamically levitated centrifugal flow blood pump.Methods and Results:Nine patients, comprising 3 with dilated cardiomyopathy, 3 with fulminant myocarditis, and 3 with ischemic heart disease, and 6 males, whose mean age was 47.7±8.1 years, were enrolled into the study. Six patients had Interagency Registry for Mechanically Assisted Circulatory Support profile 1, and 3 were profile 2. The primary endpoint was a composite of survival free from device-related serious adverse events and complications during circulatory support. Eight patients received left ventricular support, of whom 3 received concomitant right ventricular support using extracorporeal membrane oxygenation circuits, as a consequence of severe respiratory failure. One patient with fulminant myocarditis received biventricular support using the novel VAD system. After 19.0±13.5 days, 3 patients were weaned from circulatory support, because their native cardiac function recovered, and 6 patients required conversion to a durable device as a bridge-to-transplantation. One patient had non-disabling ischemic stroke episodes, and no patients died. CONCLUSIONS: This novel extracorporeal VAD system with a hydrodynamically levitated centrifugal pump can safely and successfully bridge patients with advanced heart failure to subsequent therapeutic stages.


Assuntos
Oxigenação por Membrana Extracorpórea/instrumentação , Insuficiência Cardíaca/terapia , Coração Auxiliar , Implantação de Prótese/instrumentação , Função Ventricular Esquerda , Função Ventricular Direita , Adulto , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/mortalidade , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Transplante de Coração , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Implantação de Prótese/efeitos adversos , Implantação de Prótese/mortalidade , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento
17.
Circ J ; 84(6): 965-974, 2020 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-32350231

RESUMO

BACKGROUND: During these 2 decades (1999-2019), many therapeutic strategies have been developed in the field of heart transplant (HTx) to improve post-HTx outcomes. In the present study, 116 consecutive HTx adults between 1999 and 2019 were retrospectively reviewed to evaluate the influences of a therapeutic modification on post HTx outcomes.Methods and Results:Patient survival, functional status and hemodynamics after HTx and modification of therapeutic strategies were reviewed. The overall cumulative survival rate at 10 and 20 years post-HTx was 96.4 and 76.7%, respectively. There were no significant differences in survival rate or exercise tolerance after HTx between extracorporeal and implantable continuous flow-LVAD. Post-HTx patient survival in patients, irrespective of the donor risk factors such as donor age, low LVEF, history of cardiac arrest, was equivalent across cohorts, while longer TIT and higher inotrope dosage prior to procurement surgery were significant risk factors for survival. In 21 patients given everolimus (EVL) due to renal dysfunction, serum creatinine significantly decreased 1 year after initiation. In 22 patients given EVL due to transplant coronary vasculopathy (TCAV), maximum intimal thickness significantly decreased 3 years after initiation. CONCLUSIONS: The analysis of a 20-year single-center experience with HTx in Japan shows encouraging improved results when several therapeutic modifications were made; for example, proactive use of donor hearts declined by other centers and the use of EVL in patients with renal dysfunction and TCAV.


Assuntos
Everolimo/administração & dosagem , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Imunossupressores/administração & dosagem , Adulto , Seleção do Doador , Everolimo/efeitos adversos , Tolerância ao Exercício , Circulação Extracorpórea , Feminino , Sobrevivência de Enxerto/efeitos dos fármacos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Transplante de Coração/efeitos adversos , Coração Auxiliar , Hemodinâmica , Humanos , Imunossupressores/efeitos adversos , Japão , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Doadores de Tecidos/provisão & distribuição , Resultado do Tratamento , Função Ventricular Esquerda , Listas de Espera
18.
Circ J ; 84(5): 815-819, 2020 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-32173690

RESUMO

BACKGROUND: The therapeutic strategy for giant cell myocarditis (GCM) remains controversial, so we reviewed the clinical status of Japanese patients with GCM.Methods and Results:We retrospectively reviewed 6 consecutive patients with GCM requiring percutaneous mechanical circulatory support (p-MCS), with 3 further requiring ventricular assist devices. One patient died during p-MCS. Cardiac function improved in the other 5 with immunosuppressive therapy, but only 3 patients treated with dual immunosuppressants, including cyclosporine (CyA), achieved >1-year survival. CONCLUSIONS: The prognosis of patients with fulminant GCM is poor, but a treatment that combines MCS and early administration of CyA-based immunosuppressants will be useful.


Assuntos
Circulação Assistida/instrumentação , Células Gigantes/efeitos dos fármacos , Coração Auxiliar , Imunossupressores/uso terapêutico , Miocardite/terapia , Miocárdio , Função Ventricular Esquerda , Idoso , Circulação Assistida/efeitos adversos , Circulação Assistida/mortalidade , Feminino , Células Gigantes/imunologia , Células Gigantes/patologia , Humanos , Imunossupressores/efeitos adversos , Japão , Masculino , Pessoa de Meia-Idade , Miocardite/imunologia , Miocardite/mortalidade , Miocardite/fisiopatologia , Miocárdio/imunologia , Miocárdio/patologia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
Circ J ; 84(6): 949-957, 2020 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-32269201

RESUMO

BACKGROUND: Sarcopenia is characterized by progressive loss of skeletal muscle and has frequently been associated with poor clinical outcomes in patients with advanced heart failure (HF). The urinary creatinine excretion rate (CER) index is an easily measured marker of muscle mass, but its predictive capacity for mortality and cerebrovascular events has not been investigated in patients with a continuous-flow implantable left ventricular assist device (CF-iLVAD).Methods and Results:We retrospectively reviewed 147 patients (mean [±SD] age 43.7±12.5 years, 106 male) who underwent CF-iLVAD implantation between April 2011 and June 2019. CER indices in 24-h urine samples before CF-iLVAD implantation were determined. Over a median follow-up of 2.3 years, there were 10 (6.8%) deaths and 43 (29.3%) cerebrovascular events. Patients were divided into 2 groups (low and high CER index) according to the median CER index in men and women (i.e., 13.71 and 12.06 mg·kg-1·day-1, respectively). Mortality and intracranial hemorrhage rates after CF-iLVAD implantation were significantly higher in the low than high CER index group (mortality 12.3% vs. 1.4% [P<0.01]; intracranial hemorrhage 23.3% vs. 8.1% [P=0.01]). Multivariate Cox proportional hazard models revealed that a low CER index was an independent predictor of intracranial hemorrhage in patients receiving a CF-iLVAD (hazard ratio 3.63; 95% confidence interval 1.43-9.24; P<0.01). CONCLUSIONS: A low preoperative CER index is an independent, non-invasive predictor of intracranial hemorrhage after CF-iLVAD implantation.


Assuntos
Creatinina/urina , Insuficiência Cardíaca/terapia , Coração Auxiliar , Hemorragias Intracranianas/etiologia , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Eliminação Renal , Sarcopenia/complicações , Sarcopenia/urina , Função Ventricular Esquerda , Adulto , Biomarcadores/urina , Bases de Dados Factuais , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Hemorragias Intracranianas/diagnóstico por imagem , Hemorragias Intracranianas/mortalidade , Masculino , Pessoa de Meia-Idade , Implantação de Prótese/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sarcopenia/mortalidade , Fatores de Tempo , Resultado do Tratamento
20.
Circ J ; 84(12): 2212-2223, 2020 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-33148937

RESUMO

BACKGROUND: Appropriate indications and protocols for induction therapy using basiliximab have not been fully established in heart transplant (HTx) recipients. This study elucidated the influence of induction therapy using basiliximab along with delayed tacrolimus (Tac) initiation on the outcomes of high-risk HTx recipients.Methods and Results:A total of 86 HTx recipients treated with Tac-based immunosuppression were retrospectively reviewed. Induction therapy was administered to 46 recipients (53.5%) with impaired renal function, pre-transplant sensitization, and recipient- and donor-related risk factors (Induction group). Tac administration was delayed in the Induction group. Induction group subjects showed a lower cumulative incidence of acute cellular rejection grade ≥1R after propensity score adjustment, but this was not significantly different (hazard ratio [HR]: 0.63, 95% confidence interval [CI]: 0.37-1.08, P=0.093). Renal dysfunction in the Induction group significantly improved 6 months post-transplantation (P=0.029). The cumulative incidence of bacterial or fungal infections was significantly higher in the Induction group (HR: 10.6, 95% CI: 1.28-88.2, P=0.029). CONCLUSIONS: These results suggest that basiliximab-based induction therapy with delayed Tac initiation may suppress mild acute cellular rejection and improve renal function in recipients with renal dysfunction, resulting in its non-inferior outcome, even in high-risk patients, when applied to the appropriate recipients. However, it should be carefully considered in recipients at a high risk of bacterial and fungal infections.


Assuntos
Basiliximab/uso terapêutico , Transplante de Coração , Quimioterapia de Indução , Nefropatias , Tacrolimo/uso terapêutico , Rejeição de Enxerto/prevenção & controle , Humanos , Terapia de Imunossupressão , Imunossupressores/uso terapêutico , Nefropatias/tratamento farmacológico , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA