Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
AJR Am J Roentgenol ; 175(2): 375-9, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10915678

RESUMO

OBJECTIVE: Two different types of percutaneous fluoroscopic gastrostomy procedures were prospectively evaluated. SUBJECTS AND METHODS: Between January 1, 1998, and August 10, 1999, 127 percutaneous gastrostomy catheters were placed in 128 patients in 128 attempts. Seventy-five 12- or 14-French pigtail-retained catheters and fifty-two 20-French mushroom-retained catheters were inserted. Catheters were generally placed on the basis of operator preference except pigtail-retained tubes were preferentially placed in patients with head and neck or esophageal malignancies and mushroom-retained catheters were preferentially placed in neurologically compromised or combative patients. The technical success, procedural complications, and catheter complications were recorded. Statistical analysis was performed. RESULTS: Ninety-nine percent (127/128) of the procedures were successful, and there were no procedural complications. One catheter was not placed because the colon intervened between the abdominal wall and stomach. In patients who received pigtail-retained catheters, the major complication rate was 3% (2/75), the minor complication rate was 8% (6/75), and the tube complication rate was 36% (27/75). The following complications were seen: tube occlusion (n = 12), inadvertent catheter removal (n = 8), peristomal tube leakage (n = 7), superficial cellulitis (n = 4), aspiration pneumonia (n = 2), and T-fastener cellulitis (n = 2). In patients who received mushroom-retained catheters, the major complication rate was 0%, the minor complication rate was 2% (1/52), and the tube complication rate was 2% (1/52). Complications were superficial cellulitis (n = 1) and partial catheter fracture (n = 1). There were no significant differences in major and minor complications between procedures. Pigtail-retained catheters had a significantly higher rate of tube complications (p < 0.001) CONCLUSION: Compared with pigtail-retained catheters, mushroom-retained gastrostomy catheters are more durable and secure and are less prone to tube dysfunction. These catheters should be preferentially placed when possible.


Assuntos
Cateterismo , Gastrostomia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Fluoroscopia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estômago/diagnóstico por imagem
2.
AJR Am J Roentgenol ; 172(6): 1591-6, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10350295

RESUMO

OBJECTIVE: We studied the effectiveness of Wallstent deployment to treat elastic femoral and iliac vein stenoses in patients with lower extremity hemodialysis grafts. MATERIALS AND METHODS: Between August 31, 1992, and October 13, 1997, 44 metallic stents were deployed in 20 patients to treat stenoses exhibiting immediate, significant elastic recoil after angioplasty. Twenty-four stents were placed in the femoral and saphenous veins, and the remaining 20 stents were placed in the iliac veins. Follow-up was provided by the nephrology and surgical service at our institution and by electronic review of patients' charts. The follow-up period was from August 31, 1992, until October 1, 1998. RESULTS: Stents were successfully inserted and stenotic lesions dilated in 100% of procedures. Each patient successfully completed at least one session of dialysis after the procedure. The primary patency rate of stents was 87% 60 days after the procedure, 51% 180 days after, 39% 1 year after, and 20% 2 years after. The secondary patency rate was 95% 60 days after the procedure, 92% 180 days after, 81% 1 year after, and 62% 2 years after. Complications were limited to two graft infections that developed 5 and 7 days after stent placement. CONCLUSION: Treatment of elastic venous stenoses is effective in patients with lower extremity dialysis grafts using metallic stents. The patency rates of these devices placed in the iliac and femoral veins are comparable with those of metallic stents placed in upper extremity and central veins.


Assuntos
Veia Femoral , Oclusão de Enxerto Vascular/terapia , Veia Ilíaca , Veia Safena , Stents , Adolescente , Adulto , Idoso , Angioplastia com Balão , Prótese Vascular/estatística & dados numéricos , Feminino , Veia Femoral/diagnóstico por imagem , Oclusão de Enxerto Vascular/diagnóstico por imagem , Humanos , Veia Ilíaca/diagnóstico por imagem , Tábuas de Vida , Masculino , Pessoa de Meia-Idade , Politetrafluoretileno , Radiografia Intervencionista , Diálise Renal , Veia Safena/diagnóstico por imagem , Stents/estatística & dados numéricos , Coxa da Perna
3.
AJR Am J Roentgenol ; 173(6): 1541-4, 1999 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-10584798

RESUMO

OBJECTIVE: We evaluated the technical success and complications of percutaneous transhepatic biliary drainage in patients with nondilated intrahepatic bile ducts. MATERIALS AND METHODS: Between January 1, 1996, and August 31, 1998, 130 percutaneous transhepatic biliary drainage procedures were performed on patients with nondilated intrahepatic bile ducts. This group comprised primarily patients who had received liver transplants or who had sustained iatrogenic bile duct injuries. Access in all procedures was performed using a one-step system consisting of a 21-gauge needle and an .018-inch guidewire. The technical success and complications of the procedures were evaluated. RESULTS: Percutaneous biliary drainage was successful in 117 (90%) of 130 attempts. In four patients, two attempts were required to place a drainage catheter. The overall complication rate was 9%. There were seven (5%) minor complications and five major complications (4%). No procedure-related deaths occurred. CONCLUSION: Percutaneous biliary drainage can be performed with a high success rate in patients with nondilated intrahepatic ducts. The incidence and types of complications in this population were similar to those reported in patients with intrahepatic ductal dilatation.


Assuntos
Ductos Biliares Intra-Hepáticos/lesões , Colestase Intra-Hepática/terapia , Drenagem/instrumentação , Transplante de Fígado , Complicações Pós-Operatórias/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateteres de Demora , Feminino , Fluoroscopia/instrumentação , Humanos , Doença Iatrogênica , Masculino , Pessoa de Meia-Idade , Agulhas , Punções/instrumentação , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA