Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
2.
Geriatr Orthop Surg Rehabil ; 13: 21514593221134800, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36262694

RESUMO

Objective: In recent years, many studies have reported good results with total hip arthroplasty (THA) for displaced femoral neck fractures (FNFs). However, no study has reported the clinical outcomes of the anterolateral modified Watson-Jones THA (MWJ-THA) for displaced FNFs. This study aimed to investigate the clinical results of THA for displaced FNFs at our hospital and to discuss the advantages of MWJ-THA over THA with other approaches for displaced FNFs. Methods: Forty-three patients who underwent MWJ-THA for displaced FNFs were included in this study. Patient characteristics, preinjury walking ability, activities of daily living, implants used, walking ability (at 1, 3, and 6 months after surgery), cup placement angle, clinical hip score, surgical complications, revision surgery, and death within 1 year after surgery were investigated. Results: The mean age of the 43 patients was 63.3 years, and the mean body mass index (kg/m2) was 21.1. Regarding the heads used, 28-mm heads were used in 4 patients, 32-mm heads were used in 32 patients, and 36-mm heads were used in 7 patients. The cups were placed in the Lewinnek safety zone (93.0%). Four patients had stem sinkage of a few millimeters. 6 months postoperatively, 38 patients walked unaided, and 4 patients walked with a cane. The Harris Hip Score averaged over 90 points at all time points. No postoperative dislocation was observed. Two patients died within 1 year postoperatively. Conclusion: In this study, MWJ-THA was performed for displaced FNFs and resulted in no postoperative dislocations. Furthermore, more than 90% of the patients regained their preinjury walking ability at 6 months postoperatively. MWJ-THA has great dislocation control and is effective in treating displaced FNFs.

3.
J Orthop Surg (Hong Kong) ; 26(3): 2309499018806645, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30352543

RESUMO

PURPOSE:: Cup setting with only an alignment guide has been reported to be inaccurate in the lateral decubitus position in total hip arthroplasty (THA). We assessed the accuracy of cup positioning using only the alignment guide technique via a modified Watson Jones approach in the lateral decubitus position. METHODS:: Two hundred hips of 189 patients underwent THA from October 2014 to September 2016 via a modified Watson Jones approach. In the final sample, 181 hips of 171 patients (35 males, 136 females) were included in this investigation. The alignment of the cup was evaluated by an anteroposterior radiograph of the pelvis 1 week after surgery. Measurements were divided into safe zone determined by Callanan and Lewinnek. RESULTS:: There were 168 (92.8%) acetabular cups that were placed within the safe zone for both inclination and anteversion based on the safe zones defined by Lewinnek, and 134 (74%) acetabular cups that were placed within the safe zone defined by Callanan. Multiple logistic analysis showed that the laterality and the addition of the confirmation method were indicators for malpositioning of combined inclination and anteversion. CONCLUSION:: Our data suggested that even if special tools were not used in the lateral decubitus position, using only the alignment guide enabled cup positioning to be achieved with 92.8% accuracy in the Lewinnek safe zone and 74% accuracy in the Callanan safe zone. Multiple logistic analysis showed that the laterality and the addition of a confirmation alignment guide influenced the accuracy of cup positioning.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Reprodutibilidade dos Testes
4.
Artigo em Inglês | MEDLINE | ID: mdl-16211695

RESUMO

A 42-year-old woman complained of progressive induration in the right palm. As the mass was impossible to separate from the ulnar nerve, we excised the mass together with the digital nerve and grafted 4cm of the sural nerve. The final diagnosis was nodular fasciitis.


Assuntos
Fasciite/patologia , Mãos/inervação , Neuropatias Ulnares/patologia , Adulto , Fasciite/cirurgia , Feminino , Humanos , Neuropatias Ulnares/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA