Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Ann Vasc Surg ; 101: 120-126, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38110085

RESUMO

BACKGROUND: Despite the evidence of good performance, carbon dioxide (CO2) routine employment as a contrast agent for endovascular procedures is far from being adopted with its use currently limited to patients with renal impairment and known allergy to iodinated contrast medium (ICM). The purpose of our study is to evaluate the safety and effectiveness of CO2 guided endovascular abdominal aortic aneurysm repair (EVAR) in a standard population and to assess the rationale for a future widespread use. METHODS: We retrospectively collected data of every patient who underwent CO2 guided standard EVAR from September 2020 to May 2021 and compared them with the data of every patient who underwent EVAR using ICM from December 2019 to August 2020 in our unit. The selection of the contrast medium was not based on any preoperative factor as the contrast medium was routinely used in every patient in both periods. The primary end point of the study was the technical success rate. Secondary end points were the early and late complication rates, radiation exposure and renal function impairment. RESULTS: 49 patients underwent ICM guided EVAR and 52 patients underwent CO2 guided EVAR in our unit in the time frames specified above. The technical success rate was 100% in both groups with no accidental coverage of any target vessel. Intraoperative endoleaks were observed in 14% of ICM patients and 25% of CO2 patients. The radiation exposure was higher in the CO2 group if compared to the ICM group (311.48 vs. 159.86 median mGy/cm2 - P < 0.001). The incidence of postoperative acute kidney injury was low and similar in the 2 groups. No significant worsening over time of the renal function has been reported in both groups. CONCLUSIONS: EVAR can be safely performed under CO2 guidance without the integration of any quantity of ICM but with an increase in radiation exposure. The nephroprotective role of CO2 guided EVAR in a standard population is unclear and the same role in renal impaired patients should be validated with further studies on selected populations.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Insuficiência Renal , Humanos , Meios de Contraste/efeitos adversos , Dióxido de Carbono/efeitos adversos , Aortografia/efeitos adversos , Aortografia/métodos , Estudos Retrospectivos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Implante de Prótese Vascular/efeitos adversos , Angiografia Digital/efeitos adversos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Insuficiência Renal/etiologia , Fatores de Risco
2.
J Vasc Surg ; 77(5): 1330-1338.e2, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36621617

RESUMO

BACKGROUND: Arch pathology represents one of the last frontiers in aortic aneurysm endovascular management. Several companies recently developed dedicated branched and fenestrated endografts specifically designed for the aortic arch, aiming to overcome some of the issues associated with standard thoracic endograft and supra-aortic vessels extra-anatomic debranching. This study aimed to evaluate early outcomes obtained with a custom-made fenestrated endograft approved for thoracic aortic aneurysms exclusion. METHODS: All consecutive patients treated with the Najuta endograft (Kawasumi Laboratories, Inc, Tokyo, Japan) in Italy were enrolled prospectively and included in the study population. Anatomic characteristics and perioperative data were analyzed retrospectively. Study end points were technical success, 30-day clinical success, overall survival, supra-aortic vessel patency, endoleak, and need for reintervention or surgical conversion. RESULTS: Between 2018 and 2022, 76 patients received a Najuta endograft in Italy and were enrolled in the study. The median patient age was 72 years (interquartile range, 69-76 years) and 80.3% were male. Most of the patients received treatment for atherosclerotic aneurysms (80.3%); others were treated for postdissection aneurysms (7.9%), penetrating aortic ulcer (9.2%), or type I endoleak correction after previous thoracic endovascular repair (2.6%). Overall, 161 supra-aortic vessels were preserved through a dedicated fenestration. Technical success was achieved in 74 of 76 procedure (97.4%); both failures were associated with endoleak detection at final angiography (one type I and one type III endoleak). Two distal migrations occurred during the implanting procedure. Clinical success at 30 days was 94.7%. Two early reinterventions were needed within 30 days after index procedure: in one case, an aortic false lumen coils embolization was performed, because distal re-entry caused enlargement of the postdissection thoracic aneurysm. The other procedure consisted of a femoral pseudoaneurysm repair. The median follow-up was 7 months (interquartile range, 3-15 months); no supra-aortic vessel occlusions occurred and no patients needed surgical conversion. CONCLUSIONS: Early results suggest that, in selected patients with aortic arch pathology needing a proximal landing, an endovascular approach with the Najuta system is safe and effective, especially for those at high surgical risk. A strict follow-up with high-quality computed tomography angiography images and eventual evaluation for long-term complications is needed to confirm these initial experience findings.


Assuntos
Aneurisma da Aorta Torácica , Aneurisma Aórtico , Doenças da Aorta , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Masculino , Idoso , Feminino , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Endoleak/complicações , Estudos Retrospectivos , Fatores de Risco , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Resultado do Tratamento , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações , Aneurisma Aórtico/cirurgia , Procedimentos Endovasculares/efeitos adversos , Doenças da Aorta/cirurgia , Desenho de Prótese
3.
Eur J Vasc Endovasc Surg ; 65(6): 811-817, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36871927

RESUMO

OBJECTIVE: The aim of this study was to investigate the early outcomes of a novel off the shelf pre-loaded inner branched thoraco-abdominal endograft (E-nside) in the treatment of aortic pathologies. METHODS: Data from a physician initiated national multicentre registry on patients treated with the E-nside endograft, were prospectively collected and analysed. Pre-operative clinical and anatomical characteristics, procedural data, and early outcomes (90 days) were recorded in a dedicated electronic data capture system. The primary endpoint was technical success. Secondary endpoints were early mortality (90 days), procedural metrics, target vessel patency, endoleak rate, and major adverse events (MAEs) at 90 days. RESULTS: In total, 116 patients from 31 Italian centres were included. Mean ± standard deviation (SD) patient age was 73 ± 8 years and 76 (65.5%) were male. Aortic pathologies included degenerative aneurysm in 98 (84.5%), post-dissection aneurysm in five (4.3%), pseudoaneurysm in six (5.2%), penetrating aortic ulcer or intramural haematoma in four (3.4%), and subacute dissection in three (2.6%). Mean ± SD aneurysm diameter was 66 ± 17 mm; aneurysm extent was Crawford I - III in 55 (50.4%), IV in 21 (19.2%), pararenal in 29 (26.7%), and juxtarenal in four (3.7%). The procedure setting was urgent in 25 (21.5%) patients. Median procedural time was 240 minutes (interquartile range [IQR] 195, 303), with a median contrast volume of 175 mL (IQR 120, 235). The endograft's technical success rate was 98.2% and the 90 day mortality rate was 5.2% (n = 6; 2.1% for elective repair and 16% for urgent repair). The 90-days cumulative MAE rate was 24.1% (n = 28). At 90 days, there were 10 (2.3%) target vessel related events (nine occlusions and one type IC endoleak) and one type 1A endoleak requiring re-intervention. CONCLUSION: In this real life, non-sponsored registry, the E-nside endograft was used for the treatment of a broad spectrum of aortic pathologies, including urgent cases and different anatomies. The results showed excellent technical implantation safety and efficacy, as well as early outcomes. Longer term follow up is needed to better define the clinical role of this novel endograft.

4.
J Endovasc Ther ; : 15266028221111301, 2022 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-35852447

RESUMO

PURPOSE: Despite encouraging early results, mid- and long-term follow-up of endovascular aneurysm sealing (EVAS) has shown increased rates of failure mainly associated with endoleak detection and progressive bag separation with aneurysm reperfusion. CASE REPORT: We present the first case of a Nellix endograft stent fracture detected in a 91-year-old male patient, presenting with widespread abdominal pain, 7 years after elective treatment of an abdominal aortic aneurysm by EVAS. Considering the sudden and unexpected nature of the event, an in-depth analysis of the possible causes of this structural failure has been performed. CONCLUSION: Material fatigue could be another significant cause of late EVAS failure and should be carefully assessed in addition to endoleak detection during follow-up. CLINICAL IMPACT: The case presented in this article further underlines the importance of a strict long term follow-up protocol in every patients who underwent EVAS.

5.
J Vasc Surg ; 74(4): 1204-1213, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33684472

RESUMO

BACKGROUND: Despite promising early results, midterm failures of the Nellix endovascular aneurysm sealing (EVAS) system (Endologix Inc, Irvine, Calif) have been reported at higher than expected rates. The management of proximal endoleaks and migration differs from those after conventional endovascular aortic aneurysm repair (EVAR) owing to the peculiar design of the Nellix device. In the present study, we report a monocentric experience in the management of EVAS complications using various techniques. We also performed a comprehensive review of the relevant literature on both open surgical and endovascular management of proximal failure of EVAS from the MEDLINE database. METHODS: We retrospectively analyzed the reinterventions for type Ia endoleak and migration after elective infrarenal EVAS at our institution. We collected preoperative, intraoperative, and follow-up data. Open and endovascular techniques are described. Overall survival, aortic-related mortality, and the technical success rate (rate of exclusion of endoleaks) with endovascular techniques were the primary outcomes. RESULTS: We performed 101 infrarenal elective EVAS procedures from 2013 to 2018. Of the 101 patients, 20 (19.8%) had required reintervention for proximal sealing failure. The indications were type Ia (Is2, Is3) endoleak, migration >5 mm, sac expansion >5 mm, and secondary rupture. Of the 20 patients, 6 (30%) were treated with endovascular techniques-2 with a chimney Nellix-in-Nellix application and 4 with proximal relining with a covered stent. The remaining 14 patients (70%) were treated with late open conversion (OC). The average time from EVAS to reintervention was 36.1 months (range, 3-65 months). Six patients (30%) had undergone OC in an emergent setting because of secondary rupture. The technical success rate for the patients treated with endovascular reinterventions was 100%. The 30-day mortality was 20% (4 of 20), all emergent cases (four of six emergent repairs; 67%). The overall survival for the 20 patients was 75% (n = 15) at a mean follow-up of 15.1 months (range, 2-47 months). One patient had died after 7 months of non-aortic-related causes. CONCLUSIONS: The high reintervention rate of the Nellix graft mandates careful evaluation for its further use with the revised instructions for use, and it should not be used off-label. OC remains the strategy of choice when managing Nellix proximal sealing failures in fit patients. Chimney Nellix-in-Nellix application and transcatheter embolization are feasible alternative techniques. Proximal relining also appears to be an effective alternative to more complex interventions, although it requires further studies for validation.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Remoção de Dispositivo , Endoleak/cirurgia , Procedimentos Endovasculares/efeitos adversos , Migração de Corpo Estranho/cirurgia , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/mortalidade , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/mortalidade , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/mortalidade , Humanos , Itália , Masculino , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
J Vasc Surg ; 73(6): 1958-1965.e1, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33278539

RESUMO

BACKGROUND: Endovascular aneurysm sealing (EVAS) is an innovative alternative to conventional endovascular aneurysm repair (EVAR). EVAS relies on sac anchoring without proximal fixation to achieve sealing and should have allowed for the treatment of a broader range of anatomic features compared with standard EVAR. Despite the encouraging early reports, the mid- and long-term follow-up data have shown increased rates of failure. To address the issue, the manufacturer introduced revised instructions for use (IFU) in 2016. The present study reports the outcomes of this system after a median follow-up of 45 months. METHODS: Data for all patients electively treated with EVAS at our institution were retrospectively collected. The patients were retrospectively reclassified according to the 2016 revised IFU of the device. All patients in the present series had undergone EVAS for the treatment of infrarenal abdominal aortic aneurysms (AAAs). The primary end point was therapeutic failure: graft migration >5 mm, sac expansion >5 mm, type IA endoleak (Is2 and Is3 using the Van den Ham classification), type Ib endoleak, and secondary rupture. The overall mortality, aortic-related mortality, and reintervention rates were also analyzed. RESULTS: A total of 101 patients had undergone elective treatment by EVAS from 2013 to 2018 for infrarenal AAAs. The median follow-up was 3.75 years. Therapeutic failure was observed in 31 of the 101 patients (30.7%), with no significant difference between the in-IFU and off-IFU 2016 subgroups. Failure occurred at a median interval of 34 months from the index procedure. Of the 101 patients, 6.9% had presented with secondary rupture. Freedom from aneurysm-related mortality was 96.9% at 1 and 2 years and 89.9% at 5 years. Freedom from reintervention decreased over time: 94.7% at 1 year, 77% at 4 years, and 52.1% at 6 years. Of the 101 patients, 14 (13.9%) had undergone emergent or elective graft explantation. CONCLUSIONS: EVAS performed worse than conventional endografts for several critical end points, regardless of any preoperative anatomic parameters. The incidence of therapeutic failures tended to increase over time, especially 4 years after the index procedure.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/etiologia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Endoleak/etiologia , Procedimentos Endovasculares/instrumentação , Migração de Corpo Estranho/etiologia , Falha de Prótese , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/mortalidade , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Remoção de Dispositivo , Endoleak/diagnóstico por imagem , Endoleak/mortalidade , Endoleak/cirurgia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/mortalidade , Migração de Corpo Estranho/cirurgia , Humanos , Masculino , Intervalo Livre de Progressão , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Falha de Tratamento
7.
Catheter Cardiovasc Interv ; 98(1): E115-E121, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33893754

RESUMO

BACKGROUND: While the experience with PCSK9i in patients with coronary artery disease has been wide, and coronary plaque regression has been documented, little is known regarding the role of these drugs on carotid plaque regression. The CARotid plaqUe StabilizatiOn and regression with evolocumab (CARUSO) study is a randomized, single-center, investigator-initiated trial aiming at evaluating carotid plaque morphological stabilization and regression following, respectively, 6 and 12 months of therapy with evolocumab. METHODS: Asymptomatic patients with uni- or bilateral de novo carotid artery stenosis ≥50% and LDL-C values ≥100 mg/dl despite maximum tolerated lipid lowering therapy (LLT) will be randomized to evolocumab 140 mg s.c. every 2 weeks on top of ongoing LLT, or no additional treatment. 100 patients (50 in each arm) will be enrolled. Serial carotid duplex ultra-sonography will be performed to monitor the carotid plaque morphology and stenosis over time. RESULTS: The primary end point of the study is, (a) carotid plaque morphological stabilization at 6 months, defined as defined as the disappearance of ulcerations and fluffy components and the achievement of a regular plaque morphology with prevalence of fibrous atheroma and/or (b) carotid plaque regression at 12 months, defined as reduction of the entity of the stenosis and/or peak systolic velocity by at least 5%, as compared with baseline. CONCLUSION: The CARUSO trial will test the superiority of evolocumab on top of ongoing LLT versus ongoing LLT alone regarding carotid plaque morphological stabilization and regression. The data that support the findings of this study are available on request from the corresponding author. The data are not publicly available due to privacy or ethical restrictions.


Assuntos
Estenose das Carótidas , Placa Aterosclerótica , Anticorpos Monoclonais Humanizados , Artérias Carótidas , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/tratamento farmacológico , Humanos , Placa Aterosclerótica/tratamento farmacológico , Resultado do Tratamento
8.
Ann Vasc Surg ; 62: 173-182, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31394211

RESUMO

BACKGROUND: Endovascular aneurysm repair (EVAR) is currently accepted as an alternative to open repair for the treatment of abdominal aortic aneurysm (AAA). Approximately 40-60% of AAA patients are not considered eligible for EVAR due to unfavorable anatomy. There is currently no consensus on the definition of "hostile" aortic neck for EVAR procedure. METHODS: An Expert Panel (EP), made up of 9 Italian vascular surgeons from high-volume centers (>50 EVAR procedures/year), was assembled to share their opinion about the definition of hostile aortic neck anatomy for EVAR procedure. The process included a review of the current literature by the EP, a face-to-face meeting, and an on-line survey completed by the EP prior to and following the face-to-face meeting, using the Delphi method. RESULTS: Of the 66 reviewed studies, only 38 (58%) reported at least 1 aortic neck hostility criterion. Five anatomic parameters were identified, namely, aortic neck length, aortic neck angulation, aortic neck diameter, conical neck, and presence of circumferential calcification. Based on the results of the first survey round, these criteria and related definitions were discussed in depth during the face-to-face meeting. For 3 parameters (aortic neck diameter, aortic neck angulation, conical neck), the agreement among the EP members was already high during the first survey round while for the remaining 2 (aortic neck length, circumferential calcification) it remarkably increased from the first to the second survey round. For each of these criteria, as well as combinations of at least 2 of these criteria, specific threshold values were identified above or below which a standard EVAR approach was not considered ideal by the EP due to high/moderate risk of complications. CONCLUSIONS: EP agreed on the definition of 5 aortic neck hostility criteria, according to which they gave their opinion on the feasibility and risks of a standard EVAR approach. Further agreement will be needed and examined on the best nonstandard EVAR technique which may be offered in the presence of different combinations of hostility criteria.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Técnicas de Apoio para a Decisão , Procedimentos Endovasculares , Terminologia como Assunto , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Tomada de Decisão Clínica , Consenso , Técnica Delphi , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Humanos , Seleção de Pacientes , Valor Preditivo dos Testes , Desenho de Prótese , Medição de Risco , Fatores de Risco
9.
Ann Vasc Surg ; 56: 353.e13-353.e17, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30500654

RESUMO

Atherosclerotic superficial femoral artery (SFA) true aneurysm is rare and often associated with other aortic or peripheral aneurysms, usually discovered when it reaches a considerable diameter or becomes symptomatic. We present the case of a 92-year-old woman admitted in the emergency department with a huge ruptured SFA aneurysm. The patient underwent successful aneurysmectomy, followed by bypass grafting. Degenerative SFA aneurysms differ from other peripheral aneurysms, being usually larger and symptomatic at presentation, occurring in old people, and representing life-threatening situations. The commonest symptom is rupture.


Assuntos
Aneurisma Roto/cirurgia , Implante de Prótese Vascular , Artéria Femoral/cirurgia , Idoso de 80 Anos ou mais , Aneurisma Roto/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Ligadura , Resultado do Tratamento
10.
Ann Vasc Surg ; 55: 310.e5-310.e8, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30287296

RESUMO

BACKGROUND: Successful treatment of tandem lesions of carotid arteries may represent a challenging goal for the vascular specialist. In the "endovascular era," a hybrid approach may represent a viable option. CASE REPORT: We describe the case of a 65-year-old patient with severe postcarotid endarterectomy recurrent stenosis of the internal carotid artery (ICA) associated with primitive stenosis of the proximal common carotid artery (CCA) treated with retrograde stenting and carotid bypass using the Gore Hybrid Vascular Graft (GHVG). CONCLUSIONS: We demonstrated the effectiveness of the hybrid technique using GHVG in treating carotid tandem lesions involving CCA and ICA.


Assuntos
Implante de Prótese Vascular/instrumentação , Prótese Vascular , Artéria Carótida Primitiva/cirurgia , Artéria Carótida Interna/cirurgia , Estenose das Carótidas/cirurgia , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Artéria Carótida Primitiva/diagnóstico por imagem , Artéria Carótida Primitiva/fisiopatologia , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/fisiopatologia , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/fisiopatologia , Angiografia por Tomografia Computadorizada , Humanos , Masculino , Desenho de Prótese , Resultado do Tratamento
11.
Ann Vasc Surg ; 43: 311.e1-311.e4, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28385501

RESUMO

External carotid artery pseudoaneurysm (ECAP) is very rare. The usual mechanism is trauma or iatrogenic. We report a case of a patient with an asymptomatic, chronic ECAP secondary to partial parathyroidectomy. Percutaneous injection of the 2-component Fibrin Sealant (Tisseel; Baxter int, Deerfield, IL) with the 2 active ingredients (Sealer Protein Solution and Thrombin Solution) was carried out with successful occlusion of the pseudoaneurysmal sac. The 6-month follow-up computed tomographic scan confirmed the ECAP thrombosis. The ECAP endovascular approach is less invasive and reduces the complications of the open surgical intervention, especially in high-risk patients or presenting with hostile neck.


Assuntos
Falso Aneurisma/terapia , Lesões das Artérias Carótidas/terapia , Embolização Terapêutica/métodos , Adesivo Tecidual de Fibrina/administração & dosagem , Paratireoidectomia/efeitos adversos , Trombina/administração & dosagem , Adesivos Teciduais/administração & dosagem , Idoso , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Doenças Assintomáticas , Lesões das Artérias Carótidas/diagnóstico por imagem , Lesões das Artérias Carótidas/etiologia , Artéria Carótida Externa/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Humanos , Masculino , Paratireoidectomia/métodos , Fatores de Tempo , Resultado do Tratamento
12.
Ann Vasc Surg ; 44: 422.e1-422.e7, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28483611

RESUMO

BACKGROUND: Coral reef aorta (CRA) is a rare, potential lethal disease of the visceral aorta as it can cause visceral and renal infarction. Various surgical approaches have been proposed for the CRA treatment. The purpose of this article is to report different extensive extra-anatomic CRA treatment modalities tailored on the patients' clinical and anatomic presentation. METHODS: From April 2006 to October 2012, 4 symptomatic patients with extensive CRA were treated at our department. Extra-anatomic aortic revascularization with selective visceral vessels clamping was performed in all cases. RESULTS: Technical success was 100%. No perioperative death was registered. All patients remained asymptomatic during the follow-up period (62, 49, 25, and 94 months, respectively), with bypasses and target vessels patency. CONCLUSIONS: The extra-anatomic bypass with selective visceral vessels clamping reduces the aortic occlusion time and the risk of organ ischemia. All approaches available should be considered on a case-by-case basis and in high-volume centers.


Assuntos
Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/fisiopatologia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
13.
Ann Vasc Surg ; 44: 416.e1-416.e4, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28483614

RESUMO

The most frequent complication during carotid artery stenting (CAS) is intraoperative distal embolization. Three categories of embolic protection devices (EPDs) are routinely used through a transfemoral or transcervical approach: distal occlusion devices, distal EPDs with flow preservation using filters, and the proximal occlusive protective systems. We report the case of the internal carotid artery (ICA) plaque rupture during CAS using a proximal EPD (the Mo.Ma system; INVATEC), treated with immediate surgery. The proximal occlusive protective system permitted the common carotid artery and ICA endoclamping for the time necessary to prepare the patient for the carotid endarterectomy. The EPDs should always be chosen considering the patient's and lesion's characteristics. This knowledge allows their use even as "bridge" endovascular devices.


Assuntos
Artéria Carótida Interna/cirurgia , Estenose das Carótidas/terapia , Conversão para Cirurgia Aberta , Dispositivos de Proteção Embólica , Endarterectomia das Carótidas , Procedimentos Endovasculares/instrumentação , Stents , Idoso de 80 Anos ou mais , Angiografia , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/fisiopatologia , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/fisiopatologia , Procedimentos Endovasculares/efeitos adversos , Humanos , Masculino , Placa Aterosclerótica , Desenho de Prótese , Ruptura Espontânea , Resultado do Tratamento
14.
J Cardiovasc Surg (Torino) ; 65(1): 49-63, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38037721

RESUMO

The objective of these Guidelines is to provide recommendations for the classification, indication, treatment and management of patients suffering from aneurysmal pathology of the visceral and renal arteries. The methodology applied was the GRADE-SIGN version, and followed the instructions of the AGREE quality of reporting checklist. Clinical questions, structured according to the PICO (Population, Intervention, Comparator, Outcome) model, were formulated, and systematic literature reviews were carried out according to them. Selected articles were evaluated through specific methodological checklists. Considered Judgments were compiled for each clinical question in which the characteristics of the body of available evidence were evaluated in order to establish recommendations. Overall, 79 clinical practice recommendations were proposed. Indications for treatment and therapeutic options were discussed for each arterial district, as well as follow-up and medical management, in both candidate patients for conservative therapy and patients who underwent treatment. The recommendations provided by these guidelines simplify and improve decision-making processes and diagnostic-therapeutic pathways of patients with visceral and renal arteries aneurysms. Their widespread use is recommended.


Assuntos
Aneurisma , Embolização Terapêutica , Humanos , Artéria Renal/diagnóstico por imagem , Radiologia Intervencionista , Aneurisma/diagnóstico por imagem , Aneurisma/cirurgia , Embolização Terapêutica/efeitos adversos , Itália
15.
Cardiovasc Intervent Radiol ; 46(12): 1674-1683, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37978065

RESUMO

PURPOSE: Comparison of hybrid and total endovascular aortic arch repair at two tertiary vascular surgery centers. MATERIALS AND METHODS: Consecutive patients undergoing hybrid (HG) or total endovascular (TEG) total aortic arch repair for aneurysms or dissections were included (2008-2022). Primary outcome measure was 30-day mortality. Secondary outcomes were major complications, technical success (defined as absence of surgical conversion/mortality, high-flow endoleaks or branch/limb occlusion), clinical success (defined as absence of disabling clinical sequelae), late and aortic-related mortality/reinterventions, freedom from endoleaks, aortic diameter growth > 5 mm, graft migration and supra-aortic trunks (SAT) patency. RESULTS: In total, 30 patients were included, 17 in HG and 13 in TEG. TEG presented shorter intervention time (240.5 vs 341 min, p = 0.01), median ICU stay (1 vs 4.5 days, p < 0.01) and median length of stay (8 vs 17.5 days, p < 0.01). No intraoperative deaths occurred. Technical success was 100%; clinical success was 70.6% in HG and 100% in TEG (p = 0.05). Thirty-day mortality was 13.3%, exclusively in HG (p = 0.11). Nine major complications occurred in 8 patients, 5 in HG and 3 in TEG (p = 0.99), among which five strokes, two in HG and three in TEG (p = 0.62). Late mortality was 38.5%, six patients in HG and four in TEG, p = 0.6. Two late aortic-related deaths occurred in HG (p = 0.9). Two aortic-related reinterventions, no graft migration or SAT occlusion was observed. CONCLUSIONS: Total endovascular repair seems to shorten operative times and provide higher clinical success compared with hybrid solutions, without significant 30-day mortality differences. The most common major complication is stroke.


Assuntos
Aneurisma do Arco Aórtico , Aneurisma , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Acidente Vascular Cerebral , Humanos , Prótese Vascular , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Endoleak/cirurgia , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Aneurisma/cirurgia , Acidente Vascular Cerebral/cirurgia , Estudos Retrospectivos , Fatores de Risco
16.
G Ital Cardiol (Rome) ; 24(5): 344-354, 2023 May.
Artigo em Italiano | MEDLINE | ID: mdl-37102347

RESUMO

The aim of this paper is to present the diagnostic and therapeutic care pathway on peripheral arterial disease, recently developed in the Piedmont Region, Italy. It proposes a combined approach between the cardiologist and vascular surgeon for optimizing the treatment of patients with peripheral artery disease, which includes the most recently approved antithrombotic and lipid-lowering drugs. The goal is to promote a greater awareness on peripheral vascular disease, in order to implement its treatment patterns and consequently to perform an effective secondary cardiovascular prevention.


Assuntos
Fibrinolíticos , Doença Arterial Periférica , Humanos , Fibrinolíticos/uso terapêutico , Procedimentos Clínicos , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/tratamento farmacológico , Hipolipemiantes/uso terapêutico , Lipídeos
17.
Clin Case Rep ; 10(2): e05407, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35145692

RESUMO

Approximately 25% of patients undergoing transcatheter aortic valve implantation presents significant peripheral arterial disease. The purpose of this case report was to present a feasible approach for transcatheter heart valve in a patient with peripheral arterial disease where the presence of a subclavian stent jutting in the aortic arch made the delivery system passage a challenging procedure.

18.
Ann Vasc Surg ; 24(8): 1034-7, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20800430

RESUMO

BACKGROUND: This sequential retrospective monocentric study compares the results between general and local anesthesia for carotid endarterectomy (CEA). METHODS: Between November 2002 and October 2004, 428 CEAs were performed in our vascular unit. Two groups were formed: group GA (general anesthesia): 219 patients operated under general anesthesia; group LA (local anesthesia): 209 patients operated under local anesthesia. RESULTS: No mortality was found in both groups. After surgery, three strokes were detected in group GA and three in group LA (GA 1.36% vs. LA 1.43%, p = .9540); After CEA, there were three TIAs in GA group and none in LA group (GA 0.42% vs. LA 0%, p = .2634). CONCLUSION: The morbi-mortality was not influenced by the type of anesthesia used for carotid surgery. No statistical difference was detected in the perioperative neurological and cardiopulmonary complication rates between GA and LA.


Assuntos
Anestesia Geral , Anestesia Local , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas , Idoso , Anestesia Geral/efeitos adversos , Anestesia Local/efeitos adversos , Distribuição de Qui-Quadrado , Endarterectomia das Carótidas/efeitos adversos , Feminino , Humanos , Ataque Isquêmico Transitório/etiologia , Itália , Masculino , Seleção de Pacientes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
19.
Ann Vasc Surg ; 24(8): 1134.e9-13, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20599343

RESUMO

True aneurysms of tibial artery are rare occurrences and their rupture is really rare. We report the case of a 59-year-old man who, after an episode of bacterial endocarditis, presented a posterior tibial aneurysm formation evolved in rupture. To our knowledge, this is the first case of a true giant aneurysm rupture of the posterior tibial artery (diameter, 6 cm). The treatment consisted of aneurysmectomy and surgical arterial ligation. A follow-up of 24 months was performed with good results.


Assuntos
Aneurisma Infectado/complicações , Aneurisma Roto/etiologia , Artérias da Tíbia , Aneurisma Infectado/diagnóstico , Aneurisma Infectado/cirurgia , Aneurisma Roto/diagnóstico , Aneurisma Roto/cirurgia , Antibacterianos/uso terapêutico , Humanos , Ligadura , Masculino , Pessoa de Meia-Idade , Artérias da Tíbia/diagnóstico por imagem , Artérias da Tíbia/cirurgia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia Doppler em Cores , Procedimentos Cirúrgicos Vasculares
20.
Ann Vasc Surg ; 24(2): 257.e9-12, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20036493

RESUMO

We report the case of a 54-year-old man with acute stroke caused by left internal carotid artery (ICA) occlusion secondary to pleural mesothelioma, discovered later. The cranial computed tomography scan revealed a left hemisphere ischemic lesion. At neurological examination, the modified National Institutes of Health Stroke Scale (mNIHSS) score was 9. The carotid duplex scan (DS) showed a complete thrombotic occlusion of the left ICA. The patient underwent emergency carotid thrombectomy. The screening tests revealed thrombocytosis, hyperfibrinogenemia, increased C-reactive protein values, and multiple left pleural mesothelioma nodularity confirmed at the immunohistochemical investigation. After surgery, the patient's neurological symptoms improved, with an mNIHSS score of 3. At 30 and 120 days, the DS follow-up showed regular patency of the ICA.


Assuntos
Isquemia Encefálica/etiologia , Artéria Carótida Interna/cirurgia , Estenose das Carótidas/etiologia , Mesotelioma/complicações , Neoplasias Pleurais/complicações , Acidente Vascular Cerebral/etiologia , Trombectomia , Trombose/etiologia , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/cirurgia , Estenose das Carótidas/diagnóstico , Estenose das Carótidas/cirurgia , Humanos , Masculino , Mesotelioma/diagnóstico , Mesotelioma/terapia , Pessoa de Meia-Idade , Exame Neurológico , Inibidores da Agregação Plaquetária/uso terapêutico , Neoplasias Pleurais/diagnóstico , Neoplasias Pleurais/terapia , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/cirurgia , Trombose/diagnóstico , Trombose/cirurgia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia Doppler Dupla
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA