RESUMO
The dorsal (DRN) and median (MRN) raphe are important nuclei involved in similar functions, including mood and sleep, but playing distinct roles. These nuclei have a different composition of neuronal types and set of neuronal connections, which among other factors, determine their neuronal dynamics. Most works characterize the neuronal dynamics using classic measures, such as using the average spiking frequency (FR), the coefficient of variation (CV), and action potential duration (APD). In the current study, to refine the characterization of neuronal firing profiles, we examined the neurons within the raphe nuclei. Through the utilization of nonlinear measures, our objective was to discern the redundancy and complementarity of these measures, particularly in comparison with classic methods. To do this, we analyzed the neuronal basal firing profile in both nuclei of urethane-anesthetized rats using the Shannon entropy (Bins Entropy) of the inter-spike intervals, permutation entropy of ordinal patterns (OP Entropy), and Permutation Lempel-Ziv Complexity (PLZC). Firstly, we found that classic (i.e., FR, CV, and APD) and nonlinear measures fail to distinguish between the dynamics of DRN and MRN neurons, except for the OP Entropy. We also found strong relationships between measures, including the CV with FR, CV with Bins entropy, and FR with PLZC, which imply redundant information. However, APD and OP Entropy have either a weak or no relationship with the rest of the measures tested, suggesting that they provide complementary information to the characterization of the neuronal firing profiles. Secondly, we studied how these measures are affected by the oscillatory properties of the firing patterns, including rhythmicity, bursting patterns, and clock-like behavior. We found that all measures are sensitive to rhythmicity, except for the OP Entropy. Overall, our work highlights OP Entropy as a powerful and useful quantity for the characterization of neuronal discharge patterns.
Assuntos
Potenciais de Ação , Modelos Neurológicos , Neurônios , Dinâmica não Linear , Animais , Ratos , Potenciais de Ação/fisiologia , Neurônios/fisiologia , Núcleos da Rafe/fisiologia , Masculino , Biologia Computacional , Ratos Sprague-DawleyRESUMO
BACKGROUND: Plaque composition and wall shear stress (WSS) magnitude act as well-established players in coronary plaque progression. However, WSS magnitude per se does not completely capture the mechanical stimulus to which the endothelium is subjected, since endothelial cells experience changes in the WSS spatiotemporal configuration on the luminal surface. This study explores WSS profile and lipid content signatures of plaque progression to identify novel biomarkers of coronary atherosclerosis. METHODS: Thirty-seven patients with acute coronary syndrome underwent coronary computed tomography angiography, near-infrared spectroscopy intravascular ultrasound, and optical coherence tomography of at least 1 nonculprit vessel at baseline and 1-year follow-up. Baseline coronary artery geometries were reconstructed from intravascular ultrasound and coronary computed tomography angiography and combined with flow information to perform computational fluid dynamics simulations to assess the time-averaged WSS magnitude (TAWSS) and the variability in the contraction/expansion action exerted by WSS on the endothelium, quantifiable in terms of topological shear variation index (TSVI). Plaque progression was measured as intravascular ultrasound-derived percentage plaque atheroma volume change at 1-year follow-up. Plaque composition information was extracted from near-infrared spectroscopy and optical coherence tomography. RESULTS: Exposure to high TSVI and low TAWSS was associated with higher plaque progression (4.00±0.69% and 3.60±0.62%, respectively). Plaque composition acted synergistically with TSVI or TAWSS, resulting in the highest plaque progression (≥5.90%) at locations where lipid-rich plaque is exposed to high TSVI or low TAWSS. CONCLUSIONS: Luminal exposure to high TSVI, solely or combined with a lipid-rich plaque phenotype, is associated with enhanced plaque progression at 1-year follow-up. Where plaque progression occurred, low TAWSS was also observed. These findings suggest TSVI, in addition to low TAWSS, as a potential biomechanical predictor for plaque progression, showing promise for clinical translation to improve patient prognosis.
Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Vasos Coronários/diagnóstico por imagem , Células Endoteliais , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Lipídeos , Estresse Mecânico , Angiografia CoronáriaRESUMO
Over the last decade, several in vivo and computational investigations have significantly advanced our understanding of the pathophysiology of coronary bifurcations, contributing to the enhancement of their percutaneous revascularization. The carina of the coronary bifurcations plays a substantial role in generating their main hemodynamic features, including distinctive flow patterns with secondary flows and specific shear stress patterns. These factors play a pivotal role in determining the susceptibility, development, and progression of atherosclerosis. The underlying pathophysiological mechanisms of atherosclerosis in coronary bifurcations are complex and multifactorial. Understanding these mechanisms is fundamental to comprehending lesions at the bifurcation level and informing future treatment strategies. This review aims to present the currently available data regarding the pathophysiological and prognostic role of the carina in coronary bifurcations, offering an interpretation of these findings from the perspective of interventional cardiologists, providing valuable insights for their clinical practice.
RESUMO
BACKGROUND: Fenestrated (FEVAR) and chimney (ChEVAR) endovascular aortic repair have been applied in anatomically suitable complex aortic aneurysms. However, local hemodynamic changes may occur after repair. This study aimed to compare FEVAR's and ChEVAR's hemodynamic properties, focusing on visceral arteries. METHODS: Preoperative and postoperative computed tomography angiographies have been used to reconstruct patient-based models. Data of 3 patients, for each modality, were analyzed. Following geometric reconstruction, computational fluid dynamics simulations were used to extract near-wall and intravascular hemodynamic indicators, such as pressure drops, velocity, wall shear stress, time averaged wall shear stress, oscillatory shear index, relative residence time, and local normalized helicity. RESULTS: An overall improvement in hemodynamics was detected after repair, with either technique. Preoperatively, a disturbed prothrombotic wall shear stress profile was recorded in several zones of the sac. The local normalized helicity results showed a better organization of the helical structures at postoperative setting, decreasing thrombus formation, with both modalities. Similarly, time averaged wall shear stress increased and oscillatory shear index decreased postoperatively, signaling nondisturbed blood flow. The relative residence time was locally reduced. The flow in visceral arteries tended to be more streamlined in ChEVAR, compared to evident recirculation regions at renal and superior mesenteric artery fenestrations (P = 0.06). CONCLUSIONS: ChEVAR and FEVAR seem to improve hemodynamics toward normal values with a reduction of recirculation zones in the main graft and aortic branches. Visceral artery flow comparison revealed that ChEVAR tended to present lower recirculation regions at parallel grafts' entries while FEVAR showed less intense flow regurgitation in visceral stents.
Assuntos
Implante de Prótese Vascular , Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Hemodinâmica , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Desenho de Prótese , Estresse Mecânico , Humanos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Velocidade do Fluxo Sanguíneo , Fatores de Tempo , Aortografia , Fluxo Sanguíneo Regional , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Idoso , Masculino , Stents , Hidrodinâmica , Correção Endovascular de AneurismaRESUMO
Hemodynamics interacts with the cellular components of human vessels, influencing function and healthy status. Locally acting hemodynamic forces have been associated-by a steadily increasing amount of scientific evidence-with nucleation and evolution of atherosclerotic plaques in several vascular regions, resulting in the formulation of the 'hemodynamic risk hypothesis' of the atherogenesis. At the level of coronary arteries, however, the complexity of both anatomy and physiology made the study of this vascular region particularly difficult for researchers. Developments in computational fluid dynamics (CFD) have recently allowed an accurate modelling of the intracoronary hemodynamics, thus offering physicians a unique tool for the investigation of this crucial human system by means of advanced mathematical simulations. The present review of CFD applications in coronary artery disease was set to concisely offer the medical reader the theoretical foundations of quantitative intravascular hemodynamics-reasoned schematically in the text in its basic (i.e., pressure and velocity) and derived quantities (e.g., fractional flow reserve, wall shear stress and helicity)-along with its current implications in clinical research. Moreover, attention was paid in classifying computational modelling derived from invasive and non-invasive imaging modalities with unbiased remarks on the advantages and limitations of each procedure. Finally, an extensive description-aided by explanatory figures and cross references to recent clinical findings-was presented on the role of near-wall hemodynamics, in terms of shear stress, and of intravascular flow complexity, in terms of helical flow.
RESUMO
Despite the important advancements in the stent technology for the treatment of diseased coronary arteries, major complications still affect the postoperative long-term outcome. The stent-induced flow disturbances, and especially the altered wall shear stress (WSS) profile at the strut level, play an important role in the pathophysiological mechanisms leading to stent thrombosis (ST) and in-stent restenosis (ISR). In this context, the analysis of the WSS topological skeleton is gaining more and more interest by extending the current understanding of the association between local hemodynamics and vascular diseases. This study aims to analyze the impact that a deployed coronary stent has on the WSS topological skeleton. Computational fluid dynamics (CFD) simulations were performed in three stented human coronary artery geometries reconstructed from clinical images. The selected cases presented stents with different designs (i.e., two contemporary drug-eluting stents and one bioresorbable scaffold) and included regions with stent malapposition or overlapping. A recently proposed Eulerian-based approach was applied to analyze the WSS topological skeleton features. The results highlighted that the presence of single or multiple stents within a coronary artery markedly impacts the WSS topological skeleton. In particular, repetitive patterns of WSS divergence were observed at the luminal surface, highlighting a WSS contraction action exerted proximal to the stent struts and a WSS expansion action distal to the stent struts. This WSS action pattern was independent from the stent design. In conclusion, these findings could contribute to a deeper understanding of the hemodynamics-driven processes underlying ST and ISR.
Assuntos
Vasos Coronários , Modelos Cardiovasculares , Simulação por Computador , Vasos Coronários/fisiologia , Hemodinâmica/fisiologia , Humanos , Esqueleto , Stents , Estresse MecânicoRESUMO
BACKGROUND: The risk of recurrent ischemia and bleeding after percutaneous coronary intervention (PCI) for acute coronary syndrome (ACS) may vary during the first year of follow-up according to clinical presentation, and medical and interventional strategies. METHODS: BleeMACS and RENAMI are 2 multicenter registries enrolling patients with ACS treated with PCI and clopidogrel, prasugrel, or ticagrelor. The average daily ischemic and bleeding risks (ADIR and ADBR) in the first year after PCI were the primary end points. The difference between ADBR and ADIR was calculated to estimate the potential excess of bleeding/ischemic events in a given period or specific subgroup. RESULTS: A total of 19,826 patients were included. Overall, in the first year after PCI, the ADBR was 0.008085%, whereas ADIR was 0.008017% (Pâ¯=â¯.886). In the first 2â¯weeks ADIR was higher than ADBR (Pâ¯=â¯.013), especially in patients with ST-segment elevation myocardial infarction or incomplete revascularization. ADIR continued to be, albeit non-significantly, greater than ADBR up to the third month, whereas ADBR became higher, although not significantly, afterward. Patients with incomplete revascularization had an excess in ischemic risk (Pâ¯=â¯.003), whereas non-ST-segment elevation ACS patients and those on ticagrelor had an excess of bleeding (Pâ¯=â¯.012 and Pâ¯=â¯.022, respectively). CONCLUSIONS: In unselected ACS patients, ADIR and ADBR occurred at similar rates within 1â¯year after PCI. ADIR was greater than ADBR in the first 2â¯weeks, especially in ST-segment elevation myocardial infarction patients and those with incomplete revascularization. In the first year, ADIR was higher than ADBR in patients with incomplete revascularization, whereas ADBR was higher in non-ST-segment elevation ACS patients and in those discharged on ticagrelor.
Assuntos
Síndrome Coronariana Aguda/terapia , Hemorragia/epidemiologia , Isquemia/epidemiologia , Intervenção Coronária Percutânea/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Idoso , Clopidogrel/uso terapêutico , Feminino , Hemorragia/etiologia , Humanos , Isquemia/etiologia , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Complicações Pós-Operatórias/etiologia , Cloridrato de Prasugrel/uso terapêutico , Recidiva , Sistema de Registros , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Ticagrelor/efeitos adversos , Ticagrelor/uso terapêutico , Fatores de TempoRESUMO
INTRODUCTION: In new generation drug eluting stents (DESs) era, the impact of stent geometry on freedom from recurrent events has been poorly explored. Impact of struts thickness and the number of crowns and connectors on clinical outcomes were evaluated in the present study. METHODS: Randomized controlled trials comparing last generation DESs were selected. The primary endpoint was the rate of target lesion revascularization (TLR), while secondary was definite stent thrombosis (ST). RESULTS: Fifty-three studies with 52,006 patients were included. A struts thickness ≤81 nm was associated with a lower incidence of TLR (2.9%: 2.4-3.4 vs. 3.6%: 3.0-4.3) and ST (0.8%: 0.6-1.1 vs. 1.3%: 0.9-1.8). A mean number of connectors >2.5 was also associated with a lower incidence of TLR (3.2%: 2.8-3.6 vs. 3.5%: 2.9-4.2) and ST (1.0%:0.8-1.3 vs. 1.3%: 0.9-1.7 vs. for ST). On the other hand, stents with average number of crowns <7.5 did not perform better than stents with higher average number of crowns. CONCLUSIONS: The findings of the study support that lower struts thickness and higher numbers of connectors have a positive clinical outcome reducing stent thrombosis and target lesion revascularizations, while the average number of stent crowns plays a secondary role.
Assuntos
Doença da Artéria Coronariana/terapia , Trombose Coronária/prevenção & controle , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Recidiva , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVES: To evaluate the independent clinical impact of stent structural features in a large cohort of patients undergoing unprotected left main (ULM) or coronary bifurcation percutaneous coronary intervention (PCI) with a range of very thin strut stents. BACKGROUND: Clinical impact of structural features of contemporary stents remains to be defined. METHODS: All consecutive patients enrolled in the veRy thin stents for patients with left mAIn or bifurcatioN in real life (RAIN) registry were included. The following stent structural features were studied: antiproliferative drugs (everolimus vs. sirolimus vs. zotarolimus), strut material (platinum-chromium vs. cobalt-chromium), polymer (bioresorbable vs. durable), number of crowns (<8 vs. ≥8) and number of connectors (<3 vs. ≥3). For small diameter stents (≤2.5 mm), struct thickness (74 vs. 80/81 µm) was also tested. Target lesion failure (TLF), a composite of target lesion revascularization and stent thrombosis, was the primary endpoint. Multivariate analysis was performed with Cox regression models. RESULTS: Out of 2,707 patients, 110 (4.1%) experienced a TLF event after 16 months (12-18). After adjustment for confounders, an increased number of connectors (adjusted hazard ratio [adj-HR] 0.62, 95% confidence interval (CI) 0.39-0.99, p = .04) reduced risk of TLF, driven by stents with ≥2.5 mm diameter (HR 0.54, 95% CI 0.32-0.93, p = .02). This independent relationship was lost for stents with diameter <2.5 mm, where only strut thickness appeared to impact. Conversely, no independent relationship of polymer type, number of crowns, and the specific limus-family eluted drug with outcomes was observed. CONCLUSIONS: Among a range of contemporary very thin stent models, an increased number of connectors improved device-related outcomes in this investigated high-risk procedural setting.
Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
Endovascular aneurysm repair (EVAR) has disseminated rapidly as an alternative to open surgical repair for the treatment of abdominal aortic aneurysms (AAAs), because of its reduced invasiveness, low mortality, and morbidity rate. The effectiveness of the endovascular devices used in EVAR is always at question as postoperative adverse events can lead to re-intervention or to a possible fatal scenario for the circulatory system. Motivated by the assessment of the risks related to thrombus formation, here the impact of two different commercial endovascular grafts on local hemodynamics is explored through 20 image-based computational hemodynamic models of EVAR-treated patients (N = 10 per each endograft model). Hemodynamic features, susceptible to promote thrombus formation, such as flow separation and recirculation, are quantitatively assessed and compared with the local hemodynamics established in image-based infrarenal abdominal aortic models of healthy subjects (N = 10). Moreover, the durability of endovascular devices is investigated analyzing the displacement forces (DFs) acting on them. The hemodynamic analysis is complemented by a geometrical characterization of the EVAR-induced reshaping of the infrarenal abdominal aortic vascular region. The findings of this study indicate that (1) the clinically observed propensity to thrombus formation in devices used in EVAR strategies can be explained in terms of local hemodynamics by means of image-based computational hemodynamics approach; (2) reportedly prothrombotic hemodynamic structures are strongly associated with the geometry of the aortoiliac tract postoperatively; and (3) DFs are associated with cross-sectional area of the aortoiliac tract postoperatively. In perspective, our study suggests that future clinical followup studies could include a geometric analysis of the region of the implant, monitoring shape variations that can lead to hemodynamic disturbances of clinical significance.
RESUMO
The Josephin Domain (JD), i.e. the N-terminal domain of Ataxin 3 (At3) protein, is an interesting example of competition between physiological function and aggregation risk. In fact, the fibrillogenesis of Ataxin 3, responsible for the spinocerebbellar ataxia 3, is strictly related to the JD thermodynamic stability. Whereas recent NMR studies have demonstrated that different JD conformations exist, the likelihood of JD achievable conformational states in solution is still an open issue. Marked differences in the available NMR models are located in the hairpin region, supporting the idea that JD has a flexible hairpin in dynamic equilibrium between open and closed states. In this work we have carried out an investigation on the JD conformational arrangement by means of both classical molecular dynamics (MD) and Metadynamics employing essential coordinates as collective variables. We provide a representation of the free energy landscape characterizing the transition pathway from a JD open-like structure to a closed-like conformation. Findings of our in silico study strongly point to the closed-like conformation as the most likely for a Josephin Domain in water.
Assuntos
Ataxina-3/química , Biologia Computacional/métodos , Simulação de Dinâmica Molecular , Estrutura Terciária de Proteína , Modelos Químicos , Análise de Componente Principal , TermodinâmicaRESUMO
In this paper, we report the results of molecular dynamics simulations of AXH monomer of Ataxin-1. The AXH domain plays a crucial role in Ataxin-1 aggregation, which accompanies the initiation and progression of Spinocerebellar ataxia type 1. Our simulations involving both classical and replica exchange molecular dynamics, followed by principal component analysis of the trajectories obtained, reveal substantial conformational fluctuations of the protein structure, especially in the N-terminal region. We show that these fluctuations can be generated by thermal noise since the free energy barriers between conformations are small enough for thermally stimulated transitions. In agreement with the previous experimental findings, our results can be considered as a basis for a future design of ataxin aggregation inhibitors that will require several key conformations identified in the present study as molecular targets for ligand binding.
Assuntos
Ataxina-1/química , Ataxina-1/metabolismo , Humanos , Simulação de Dinâmica Molecular , Agregados Proteicos , Estrutura Terciária de Proteína , Ataxias Espinocerebelares/metabolismo , TermodinâmicaRESUMO
Ataxin-1 is the protein responsible for the Spinocerebellar ataxia type 1, an incurable neurodegenerative disease caused by polyglutamine expansion. The AXH domain plays a pivotal role in physiological functions of Ataxin-1. In Spinocerebellar ataxia 1, the AXH domain is involved in the misfolding and aggregation pathway. Here molecular modeling is applied to investigate the protein-protein interactions contributing to the AXH dimer stability. Particular attention is focused on: (i) the characterization of AXH monomer-monomer interface; (ii) the molecular description of the AXH monomer-monomer interaction dynamics. Technically, an approach based on functional mode analysis, here applied to replica exchange molecular dynamics trajectories, was employed. The findings of this study are consistent with previous experimental results and elucidate the pivotal role of the I580 residue in mediating the AXH monomer-monomer interaction dynamics.
Assuntos
Ataxina-1/química , Ataxina-1/metabolismo , Humanos , Simulação de Dinâmica Molecular , Ligação Proteica , Domínios Proteicos , Estabilidade Proteica , TermodinâmicaRESUMO
PURPOSE: Symmetric-tip dialysis catheters have become alternative devices because of low access recirculation and ease of tip positioning. Flow characteristics of three symmetric catheters were compared based on computational fluid dynamics (CFD) as they relate to catheter function. MATERIALS AND METHODS: In Palindrome, GlidePath, and VectorFlow catheters, a computational fluid dynamics-based approach was used to assess (i) regions of flow separation, which are prone to thrombus development; (ii) shear-induced platelet activation potency; (iii) recirculation; and (iv) venous outflow deflection. A steady-state, laminar flow model simulated catheter tip position within the superior vena cava. Catheter performance was investigated at high hemodialysis flow rate (400 mL/min). Blood was assumed as a Newtonian fluid. RESULTS: Wide regions of flow separation downstream of the Palindrome side slot and close to the distal tip were observed in forward and reversed line configurations. Geometric asymmetry of the distal guide wire aperture of the GlidePath catheter produced the highest levels of inverted velocity flow when run in reversed configuration. The lowest mean shear-induced platelet activation was exhibited by GlidePath and VectorFlow catheters; the Palindrome catheter exhibited 152% higher overall platelet activation potency. All catheters were associated with a recirculation close to zero; the helically contoured lumens of the VectorFlow catheter produced the greatest amount of deflection of venous flow away from the arterial lumen. CONCLUSIONS: The VectorFlow catheter produced less shear-induced platelet activation than the Palindrome catheter and less flow separation than the Palindrome and GlidePath catheters irrespective of line configuration. These findings have potential implications for differences in thrombogenic risk during clinical performance of these catheters.
Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Cateteres Venosos Centrais , Modelos Cardiovasculares , Ativação Plaquetária/fisiologia , Diálise Renal/instrumentação , Veia Cava Superior/fisiologia , Pressão Sanguínea/fisiologia , Simulação por Computador , Análise de Falha de Equipamento , Humanos , Desenho de Prótese , Reologia/métodos , Resistência ao Cisalhamento/fisiologiaRESUMO
Over the last years computer modelling and simulation has emerged as an effective tool to support the total product life cycle of cardiovascular devices, particularly in the device preclinical evaluation and post-market assessment. Computational modelling is particularly relevant for heart valve prostheses, which require an extensive assessment of their hydrodynamic performance and of risks of hemolysis and thromboembolic complications associated with mechanically-induced blood damage. These biomechanical aspects are typically evaluated through a fluid-structure interaction (FSI) approach, which enables valve fluid dynamics evaluation accounting for leaflets movement. In this context, the present narrative review focuses on the computational modelling of bileaflet mechanical aortic valves through FSI approach, aiming to foster and guide the use of simulations in device total product life cycle. The state of the art of FSI simulation of heart valve prostheses is reviewed to highlight the variety of modelling strategies adopted in the literature. Furthermore, the integration of FSI simulations in the total product life cycle of bileaflet aortic valves is discussed, with particular emphasis on the role of simulations in complementing and potentially replacing the experimental tests suggested by international standards. Simulations credibility assessment is also discussed in the light of recently published guidelines, thus paving the way for a broader inclusion of in silico evidence in regulatory submissions. The present narrative review highlights that FSI simulations can be successfully framed within the total product life cycle of bileaflet mechanical aortic valves, emphasizing that credible in silico models evaluating the performance of implantable devices can (at least) partially replace preclinical in vitro experimentation and support post-market biomechanical evaluation, leading to a reduction in both time and cost required for device development.
RESUMO
The present study adopts a smartphone-based approach for the experimental characterization of coronary flows. Technically, Particle Tracking Velocimetry (PTV) measurements were performed using a smartphone camera and a low-power continuous wave laser in realistic healthy and stenosed phantoms of left anterior descending artery with inflow Reynolds numbers approximately ranging from 20 to 200. A Lagrangian-Eulerian mapping was performed to convert Lagrangian PTV velocity data to a Eulerian grid. Eulerian velocity and vorticity data obtained from smartphone-based PTV measurements were compared with Particle Image Velocimetry (PIV) measurements performed with a smartphone-based setup and with a conventional setup based on a high-power double-pulsed laser and a CMOS camera. Smartphone-based PTV and PIV velocity flow fields substantially agreed with conventional PIV measurements, with the former characterized by lower average percentage differences than the latter. Discrepancies emerged at high flow regimes, especially at the stenosis throat, due to particle image blur generated by smartphone camera shutter speed and image acquisition frequency. In conclusion, the present findings demonstrate the feasibility of PTV measurements using a smartphone camera and a low-power light source for the in vitro characterization of cardiovascular flows for research, industrial and educational purposes, with advantages in terms of costs, safety and usability.
Assuntos
Fenômenos Fisiológicos Cardiovasculares , Smartphone , Reologia/métodos , Velocidade do Fluxo Sanguíneo , Imagens de FantasmasRESUMO
The electrical activity of the brain, characterized by its frequency components, reflects a complex interplay between periodic (oscillatory) and aperiodic components. These components are associated with various neurophysiological processes, such as the excitation-inhibition balance (aperiodic activity) or interregional communication (oscillatory activity). However, we do not fully understand whether these components are truly independent or if different neuromodulators affect them in different ways. The dopaminergic system has a critical role for cognition and motivation, being a potential modulator of these power spectrum components. To improve our understanding of these questions, we investigated the differential effects of this system on these components using electrocorticogram recordings in cats, which show clear oscillations and aperiodic 1/f activity. Specifically, we focused on the effects of haloperidol (a D2 receptor antagonist) on oscillatory and aperiodic dynamics during wakefulness and sleep. By parameterizing the power spectrum into these two components, our findings reveal a robust modulation of oscillatory activity by the D2 receptor across the brain. Surprisingly, aperiodic activity was not significantly affected and exhibited inconsistent changes across the brain. This suggests a nuanced interplay between neuromodulation and the distinct components of brain oscillations, providing insights into the selective regulation of oscillatory dynamics in awake states.
Assuntos
Encéfalo , Haloperidol , Sono , Vigília , Vigília/efeitos dos fármacos , Vigília/fisiologia , Animais , Haloperidol/farmacologia , Sono/efeitos dos fármacos , Sono/fisiologia , Gatos , Encéfalo/efeitos dos fármacos , Encéfalo/fisiologia , Masculino , Ondas Encefálicas/efeitos dos fármacos , Ondas Encefálicas/fisiologia , Eletrocorticografia/efeitos dos fármacos , Antagonistas de Dopamina/farmacologiaRESUMO
BACKGROUND AND OBJECTIVES: Vascular stents are scaffolding structures implanted in the vessels of patients with obstructive disease. Stents are typically designed as cylindrical lattice structures characterized by the periodic repetition of unit cells. Their design, including geometry and material characteristics, influences their mechanical performance and, consequently, the clinical outcomes. Computational optimization frameworks have proven to be effective in assisting the design phase of vascular stents, facilitating the achievement of enhanced mechanical performances. However, the reliance on time-consuming simulations and the challenge of automating the design process limit the number of design evaluations and reduce optimization efficiency. In this context, a rapid and automated method for the mechanical characterization of vascular stents is presented, taking the stent geometry, conceived as the periodic repetition of a unit cell, and material as input and providing the mechanical response of the stent as output. METHODS: Vascular stents were assumed to be thin-walled hollow cylinders sharing the same macroscopic geometrical characteristics as the cylindrical lattice structure but composed of an anisotropic homogenized material. Homogenization theory was applied to average the microscopic inhomogeneities at the stent unit cell level into a homogenized material at the macro-scale, enabling the calculation of the associated homogenized material tensor. Analytical formulations were derived to relate the stent mechanical behavior to the homogenized stiffness tensor, considering linear elastic theory for thin-walled hollow cylinders and three loading scenarios of relevance for vascular stents: radial crimping; axial traction; torsion. Validation was conducted by comparing the derived analytical formulations with results obtained from finite element analyses on typical stent designs. RESULTS: Homogenized stiffness tensors were computed for the unit cells of three stent designs, revealing insights into their mechanical performance, including whether they exhibit auxetic behavior. The derived analytical formulations were successfully validated with finite element analyses, yielding low relative differences in the computed values of foreshortening, radial, axial and torsional stiffnesses for all three stents. CONCLUSIONS: The proposed method offers a rapid, fully automated procedure that facilitates the assessment of the mechanical behavior of vascular stents and is suitable for effective integration into computational optimization frameworks.
RESUMO
The remarkable mechanical properties of nickel-titanium (NiTi) shape memory alloy, particularly its super-elasticity, establish it as the material of choice for fabricating self-expanding vascular stents, including the metallic backbone of peripheral stents and the metallic frame of stent-grafts. The super-elastic nature of NiTi substantially influences the mechanical performance of vascular stents, thereby affecting their clinical effectiveness and safety. This property shows marked sensitivity to the primary parameters of the heat treatment process used in device fabrication, specifically temperature and processing time. In this context, this study integrates experimental and computational analyses to explore the potential of designing the mechanical characteristics of NiTi vascular stents by adjusting heat treatment parameters. To reach this aim, differently heat-treated NiTi wire samples were experimentally characterized using calorimetric and uniaxial tensile testing. Subsequently, the mechanical response of a stent-graft model featuring a metallic frame made of NiTi wire was assessed in terms of radial forces generated at various implantation diameters through finite element analysis. The stent-graft served as an illustrative case of NiTi vascular stent to investigate the impact of the heat treatment parameters on its mechanical response. From the study a strong linear relationship emerged between NiTi super-elastic parameters (i.e., austenite finish temperature, martensite elastic modulus, upper plateau stress, lower plateau stress and transformation strain) and heat treatment parameters (R2 > 0.79, p-value < 0.001) for the adopted ranges of temperature and processing time. Additionally, a strong linear relationship was observed between: (i) the radial force generated by the stent-graft during expansion and the heat treatment parameters (R2 > 0.82, p-value < 0.001); (ii) the radial force generated by the stent-graft during expansion and the lower plateau stress of NiTi (R2 > 0.93, p-value < 0.001). In conclusion, the findings of this study suggest that designing and optimizing the mechanical properties of NiTi vascular stents by finely tuning temperature and processing time of the heat treatment process is feasible.