Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Am J Physiol Heart Circ Physiol ; 308(3): H217-31, 2015 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-25398980

RESUMO

We developed a mathematical model of the cerebral venous outflow for the simulation of the average blood flows and pressures in the main drainage vessels of the brain. The main features of the model are that it includes a validated model for the simulation of the intracranial circulation and it accounts for the dependence of the hydraulic properties of the jugular veins with respect to the gravity field, which makes it an useful tool for the study of the correlations between extracranial blood redistributions and changes in the intracranial environment. The model is able to simulate the average pressures and flows in different points of the jugular ducts, taking into account the amount of blood coming from the anastomotic connections; simulate how the blood redistribution due to change of posture affects flows and pressures in specific points of the system; and simulate redistributions due to stenotic patterns. Sensitivity analysis to check the robustness of the model was performed. The model reproduces average physiologic behavior of the jugular, vertebral, and cerebral ducts in terms of pressures and flows. In fact, jugular flow drops from ∼11.7 to ∼1.4 ml/s in the passage from supine to standing. At the same time, vertebral flow increases from 0.8 to 3.4 ml/s, while cerebral blood flow, venous sinuses pressure, and intracranial pressure are constant around the average value of 12.5 ml/s, 6 mmHg, and 10 mmHg, respectively. All these values are in agreement with literature data.


Assuntos
Veias Cerebrais/fisiologia , Circulação Cerebrovascular , Hemodinâmica , Modelos Cardiovasculares , Humanos , Veias Jugulares/fisiologia
2.
Phys Med Biol ; 65(24): 245002, 2020 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-32693398

RESUMO

Interference effects are included in the x-ray coherent scattering models used in Monte Carlo codes by modifying each material form factor through a proper interference function, which is obtained directly from the measured scattering pattern. This approach is effective for non-biological materials, but it is impractical for biological tissues, due the wide composition variability they can feature. Instead, a given biological sample can be considered as a proper mixture of four basis materials: fat, water, collagen and calcium hydroxyapatite. The sample form factor can then be obtained through a weighted mean of the form factors of the basis materials, which include interference effects. Here, we fully demonstrate the validity of the proposed segmentation method by applying it to 31 biological tissue samples whose form factors are available in the literature. The segmentation, namely the determination of the optimal weight of the basis components, was carried out through a multiple linear regression or, in some cases, by using a controlled trial and error sequence. The form factors of the basis materials were extracted from previous works and elaborated to include more scattering features. In particular, they were interpolated at a denser grid. Furthermore, the data measured separately in wide angle and small angle regimes, for fat and collagen, were merged. In general, a very good agreement was obtained between the original sample and the calculated mixture, being the mean relative difference of their scattering profiles and their attenuation coefficients ∼10%. The segmentation method is fully supported by our extension to the Geant4 model of x-ray coherent scattering, which was used to compare simulated scatter distributions with known experimental data. The developed Geant4 code and a series of molecular form factors, including those of the basis materials, are freely downloadable from a dedicated web repository.


Assuntos
Método de Monte Carlo , Espalhamento de Radiação , Humanos , Modelos Biológicos , Água , Raios X
3.
Phys Med ; 77: 127-137, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32829101

RESUMO

MariX is a research infrastructure conceived for multi-disciplinary studies, based on a cutting-edge system of combined electron accelerators at the forefront of the world-wide scenario of X-ray sources. The generation of X-rays over a large photon energy range will be enabled by two unique X-ray sources: a Free Electron Laser and an inverse Compton source, called BriXS (Bright compact X-ray Source). The X-ray beam provided by BriXS is expected to have an average energy tunable in the range 20-180 keV and intensities between 1011 and 1013 photon/s within a relative bandwidth ΔE/E=1-10%. These characteristics, together with a very small source size (~20 µm) and a good transverse coherence, will enable a wide range of applications in the bio-medical field. An additional unique feature of BriXS will be the possibility to make a quick switch of the X-ray energy between two values for dual-energy and K-edge subtraction imaging. In this paper, the expected characteristics of BriXS will be presented, with a particular focus on the features of interest to its possible medical applications.


Assuntos
Lasers , Fótons , Elétrons , Radiografia , Raios X
4.
Med Phys ; 36(10): 4683-701, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19928100

RESUMO

PURPOSE: A 3-year project called LABSYNC has been recently funded by the European Commission, with the aim of designing a radiation facility based on a compact light source, i.e., a laboratory-sized commercial synchrotron, capable of accelerating electrons up to 6 or 20 MeV. An accurate spectral description of hard x rays emitted from thin targets, irradiated by electron beams circulating in the storage ring, is of primary interest for the design and the characterization of a beamline. This article, Part I, aims at optimizing some of the parameters which are critical for the design of medical applications based on the above compact light source. The goal was to evaluate the dependence of photon fluence and beam monochromaticity on electron-beam energy, target material, and thickness. METHODS: The transport of 6 and 20 MeV electrons in a thin molybdenum, rhodium, and tungsten target is studied by means of Monte Carlo simulations using MCNPX. Configurations of the x-ray output port, different from the default forward-directed emission of the beam, are also investigated. A comparison with reference spectra for general diagnostic radiology and mammography is carried out. RESULTS: It is shown that the emitted x-ray beams can be far more intense than those generated by conventional x-ray tubes for radiography applications. The profiles of the calculated polychromatic spectra resemble those generated by conventional x-ray tubes, with x-ray energies up to the energy of the incident-electron beam. An appreciable improvement in the monochromaticity of the beams can be obtained by viewing the x-ray emission from an output port antiparallel to the direction of the incident-electron beam. CONCLUSIONS: The optimum target thickness for tungsten target spectra is practically constrained by a trade-off between bremsstrahlung efficiency and focal-spot size requirements. A larger margin for optimization of target thickness is probably available for mammographic spectra. The constraint of a backward-directed (or, to a lesser extent, orthogonal) output port is to be considered mandatory for minimizing the high-energy tail of the spectral distribution and keeping the radiation dose to a reasonable level. It is also fundamental to evaluate the impact of the high-energy tail of the emitted spectra in x-ray imaging applications, since the energy range involved is significantly beyond the diagnostic range. This topic will be dealt with in Part II of the article.


Assuntos
Desenho Assistido por Computador , Aceleradores de Partículas/instrumentação , Intensificação de Imagem Radiográfica/instrumentação , Radiografia/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização , Controle de Qualidade , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Raios X
5.
Phys Med Biol ; 64(18): 185002, 2019 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-31307026

RESUMO

Coronary angiography is clinically used worldwide to diagnose diseases of coronary arteries. Despite its effectiveness, this technique is quite invasive and it is associated with significant risks due to the arterial catheterisation needed to inject the contrast agent. A valid alternative is using the K-edge subtraction (KES) method, which is based on the subtraction of two images acquired at energies bracketing the K-edge of the contrast element. The enhanced sensitivity of KES allows the intravenous injection of the contrast agent, thus reducing the risks of catheterisation. This technique can be effectively implemented by using intense and quasi-monochromatic x-ray beams. Synchrotron radiation has been proven to work well for this purpose, but its cost and size prevent a widespread clinical application. Inverse Compton sources are among the most promising innovative sources of intense and quasi-monochromatic x-rays. These sources are intrinsically more compact than those based on synchrotron radiation. In this work, the potential application of inverse Compton radiation to KES angiography is investigated. To this purpose, after a short review of the physics behind the inverse Compton process, an analytical framework is described. The proposed model is based on the application of the KES algorithm to calculate the SNR of details inside a suitable mathematical phantom. That allowed us to identify the characteristics of an inverse Compton source required for KES imaging. In particular, it was estimated that a photon fluence of 108 ph mm-2 is necessary to detect signals of clinical interest. Novel sources based on inverse Compton promise to achieve this requirement with an acquisition time of few hundreds of ms. This feature, together with compactness, broad two-dimensional radiation field, absence of harmonic contamination and the ability to deliver high photon fluxes also at high energies, makes this kind of sources promising for KES angiography and other diagnostic applications.


Assuntos
Angiografia Coronária/métodos , Técnica de Subtração , Algoritmos , Angiografia Coronária/instrumentação , Imagens de Fantasmas , Fótons , Razão Sinal-Ruído , Técnica de Subtração/instrumentação , Síncrotrons , Raios X
6.
Med Phys ; 35(1): 13-24, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18293556

RESUMO

The effect of the energy dispersion of a quasi-monochromatic x-ray beam on the performance of a dual-energy x-ray imaging system is studied by means of Monte Carlo simulations using MCNPX (Monte Carlo N-Particle eXtended) version 2.6.0. In particular, the case of subtraction imaging at the iodine K-edge, suitable for angiographic imaging application, is investigated. The average energies of the two beams bracketing the iodine K-edge are set to the values of 31.2 and 35.6 keV corresponding to the ones obtained with a compact source based on a conventional x-ray tube and a mosaic crystal monochromator. The energy dispersion of the two beams is varied between 0 and 10 keV of full width at half-maximum (FWHM). The signal and signal-to-noise ratio produced in the simulated images by iodine-filled cavities (simulating patient vessels) drilled in a PMMA phantom are studied as a function of the x-ray energy dispersion. The obtained results show that, for the considered energy separation of 4.4 keV, no dramatic deterioration of the image quality is observed with increasing x-ray energy dispersion up to a FWHM of about 2.35 keV. The case of different beam energies is also investigated by means of fast simulations of the phantom absorption.


Assuntos
Angiografia Digital/métodos , Iodo/química , Método de Monte Carlo , Simulação por Computador , Elétrons , Humanos , Imagens de Fantasmas , Fótons , Raios X
7.
Phys Med Biol ; 53(20): 5675-88, 2008 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-18812651

RESUMO

Myelin is a multi-lamellar membrane surrounding neuronal axons and increasing their conduction velocity. When investigated by small-angle x-ray scattering (SAXS), the lamellar quasi-periodical arrangement of the myelin sheath gives rise to distinct peaks, which allow the determination of its molecular organization and the dimensions of its substructures. In this study we report on the myelin sheath structural determination carried out on a set of human brain tissue samples coming from surgical biopsies of two patients: a man around 60 and a woman nearly 90 years old. The samples were extracted either from white or grey cerebral matter and did not undergo any manipulation or chemical-physical treatment, which could possibly have altered their structure, except dipping them into a formalin solution for their conservation. Analysis of the scattered intensity from white matter of intact human cerebral tissue allowed the evaluation not only of the myelin sheath periodicity but also of its electronic charge density profile. In particular, the thicknesses of the cytoplasm and extracellular regions were established, as well as those of the hydrophilic polar heads and hydrophobic tails of the lipid bilayer. SAXS patterns were measured at several locations on each sample in order to establish the statistical variations of the structural parameters within a single sample and among different samples. This work demonstrates that a detailed structural analysis of the myelin sheath can also be carried out in randomly oriented samples of intact human white matter, which is of importance for studying the aetiology and evolution of the central nervous system pathologies inducing myelin degeneration.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/ultraestrutura , Bainha de Mielina/diagnóstico por imagem , Bainha de Mielina/ultraestrutura , Espalhamento a Baixo Ângulo , Difração de Raios X/métodos , Humanos , Conformação Molecular , Radiografia
8.
Phys Med ; 51: 64-70, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29724659

RESUMO

An extension to Geant4 Monte Carlo code was developed to take into account inter-atomic (molecular) interference effects in X-ray coherent scattering. Based on our previous works, the developed code introduces a set of form factors including interference effects for a selected variety of amorphous materials useful for medical applications, namely various tissues and plastics used to build phantoms. The code is easily upgradable in order to include new materials and offers the possibility to model a generic tissue as a combination of a set of four basic components. A dedicated Geant4 application for the simulation of X-ray diffraction experiments was created to validate the proposed upgrade of Rayleigh scattering model. A preliminary validation of the code obtained through a comparison with EGS4 and an experiment is presented, showing a satisfactory agreement.


Assuntos
Método de Monte Carlo , Espalhamento a Baixo Ângulo , Difração de Raios X/instrumentação , Imagens de Fantasmas
9.
Eur J Cancer ; 43(4): 660-75, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17276672

RESUMO

According to EUSOMA position paper 'The requirements of a specialist breast unit', each breast unit should have a core team made up of health professionals who have undergone specialist training in breast cancer. In this paper, on behalf of EUSOMA, authors have identified the standards of training in breast cancer, to harmonise and foster breast care training in Europe. The aim of this paper is to contribute to the increase in the level of care in a breast unit, as the input of qualified health professionals increases the quality of breast cancer patient care.


Assuntos
Neoplasias da Mama/terapia , Educação Médica , Pessoal de Saúde/educação , Oncologia/educação , Educação em Enfermagem/métodos , Feminino , Cirurgia Geral/educação , Humanos , Medicina Nuclear/educação , Radiologia/educação
10.
Phys Med Biol ; 52(11): 3015-26, 2007 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-17505086

RESUMO

The aim of the work is to quantitatively compare the effect of the energy separation in the k-edge digital subtraction imaging technique. Images of a custom-made, iodine filled (k-edge = 33.17 keV) test object have been acquired with monochromatic x-ray beams (energy spread <0.1 keV) at the ID17 biomedical beamline of the ESRF. Image acquisition has been performed using two energy separations, namely 0.65 keV (32.85 keV and 33.5 keV, respectively) and 4.4 keV (31.2 keV and 35.6 keV, respectively), using beams of energies on either side of the iodine k-edge. Signal and signal-to-noise ratio (SNR) analysis has been performed as a function of DeltaE and the contrast medium concentrations. The results show that the SNR values measured for DeltaE < 1 keV are only slightly higher than those measured for DeltaE = 4.4 keV. This preliminary study shows that monochromaticity and the energy separation obtained with quasi monochromatic beams from conventional x-ray sources might be suitable for this imaging technique.


Assuntos
Diagnóstico por Imagem/métodos , Intensificação de Imagem Radiográfica/métodos , Técnica de Subtração , Síncrotrons/instrumentação , Biofísica/métodos , Meios de Contraste , Humanos , Processamento de Imagem Assistida por Computador , Iodo/química , Modelos Estatísticos , Modelos Teóricos , Imagens de Fantasmas , Fótons , Raios X
11.
Physiol Meas ; 38(11): 1939-1952, 2017 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-28857747

RESUMO

OBJECTIVE: The gravitational gradient is the major component to face when considering the physiology of venous return, and there is a growing interest in understanding the mechanisms ensuring the heart filling, in the absence of gravity, for astronauts who perform long-term space missions. APPROACH: The purpose of the Drain Brain project was to monitor the cerebral venous outflow of a crew member during an experiment on the International Space Station (ISS), so as to study the compensatory mechanisms that facilitate this essential physiological action in subjects living in a microgravity environment. Such venous function has been characterized by means of a novel application of strain-gauge plethysmography which uses a capacitive sensor. MAIN RESULTS: In this contribution, preliminary results of our investigation have been presented. In particular, comparison of plethysmography data confirmed that long duration spaceflights lead to a redistribution of venous blood volume, and showed interesting differences in the amplitude of cardiac oscillations measured at the level of the neck veins. SIGNIFICANCE: The success of the experiment has also demonstrated that thanks to its easy portability, non-invasiveness, and non-operator dependence, the proposed device can be considered as a novel tool for use aboard the ISS. Further trials are now under way to complete the investigation on the drainage function of the neck veins in microgravity.


Assuntos
Veias Cerebrais/fisiologia , Circulação Cerebrovascular , Ausência de Peso , Adulto , Feminino , Humanos , Modelos Biológicos , Pletismografia , Respiração
13.
Phys Med Biol ; 51(17): 4311-28, 2006 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-16912383

RESUMO

The aim of the present work is to analytically evaluate the signal to noise ratio (SNR) and the delivered dose in K-edge digital subtraction imaging (KES) using two types of x-ray sources: a monochromatic x-ray source (available at synchrotron radiation facilities and considered as gold standard) and a quasi-monochromatic compact source. The energy separation DeltaE between the two monochromatic beams is 1 keV and 4 keV for the two sources, respectively. The evaluation has been performed for both radiography and computed tomography. Different geometries have been studied to mimic clinical situations. In mammography, a pathology perfused by a contrast agent has been modelled; in angiography, a vessel superimposed to a ventricle or a stand-alone artery stenosis has been studied. The SNR and the skin dose have been calculated as a function of the detail diameter, the contrast agent (iodine and gadolinium), and its concentration in the tissues. Results show that for DeltaE = 4 keV a slightly higher delivered dose is required to obtain the same SNR with respect to DeltaE < 1 keV. A similar study has been performed for KES-CT. Computer simulations of CT images performed with Snark software are shown to validate the analytical calculations.


Assuntos
Angiografia Digital/métodos , Meios de Contraste/química , Processamento de Sinais Assistido por Computador/instrumentação , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Gadolínio/química , Humanos , Iodo/química , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Phys Med Biol ; 51(17): 4233-51, 2006 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-16912379

RESUMO

Early manifestation of breast cancer is often very subtle and is displayed in a complex and variable pattern of normal anatomy that may obscure the disease. The use of dual-energy techniques, that can remove the structural noise, and contrast media, that enhance the region surrounding the tumour, could help us to improve the detectability of the lesions. The aim of this work is to investigate the use of an iodine-based contrast medium in mammography with two different double exposure techniques: K-edge subtraction mammography and temporal subtraction mammography. Both techniques have been investigated by using an ideal source, like monochromatic beams produced at a synchrotron radiation facility and a clinical digital mammography system. A dedicated three-component phantom containing cavities filled with different iodine concentrations has been developed and used for measurements. For each technique, information about the minimum iodine concentration, which provides a significant enhancement of the detectability of the pathology by minimizing the risk due to high dose and high concentration of contrast medium, has been obtained. In particular, for cavities of 5 and 8 mm in diameter filled with iodine solutions, the minimum concentration needed to obtain a contrast-to-noise ratio of 5 with a mean glandular dose of 2 mGy has been calculated. The minimum concentrations estimated with monochromatic beams and K-edge subtraction mammography are 0.9 mg ml(-1) and 1.34 mg ml(-1) for the biggest and smallest details, respectively, while for temporal subtraction mammography they are 0.84 mg ml(-1) and 1.31 mg ml(-1). With the conventional clinical system the minimum concentrations for the K-edge subtraction mammography are 4.13 mg ml(-1) (8 mm diameter) and 5.75 mg ml(-1) (5 mm diameter), while for the temporal subtraction mammography they are 1.01 mg ml(-1) (8 mm diameter) and 1.57 mg ml(-1) (5 mm diameter).


Assuntos
Algoritmos , Meios de Contraste/química , Iodo/química , Técnica de Subtração , Relação Dose-Resposta a Droga , Humanos , Mamografia/instrumentação , Mamografia/métodos , Imagens de Fantasmas , Controle de Qualidade , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos
15.
AJNR Am J Neuroradiol ; 37(11): 2100-2109, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27444939

RESUMO

BACKGROUND AND PURPOSE: A comprehensive parameter model was developed to investigate correlations between cerebral hemodynamics and alterations in the extracranial venous circulation due to posture changes and/or extracranial venous obstruction (stenosis). The purpose of this work was to validate the simulation results by using MR imaging and echo-color Doppler experimental blood flow data in humans. MATERIALS AND METHODS: To validate the model outcomes, we used supine average arterial and venous extracerebral blood flow, obtained by using phase-contrast MR imaging from 49 individuals with stenosis in the acquisition plane at the level of the disc between the second and third vertebrae of the left internal jugular vein, 20 with stenosis in the acquisition plane at the level of the disc between the fifth and sixth vertebrae of the right internal jugular vein, and 38 healthy controls without stenosis. Average data from a second group of 10 healthy volunteers screened with an echo-color Doppler technique were used to evaluate flow variations due to posture change. RESULTS: There was excellent agreement between experimental and simulated supine flows. Every simulated CBF fell inside the standard error from the corresponding average experimental value, as well as most of the simulated extracerebral arterial flow (extracranial blood flow from the head and face, measured at the level of the disc between second and third vertebrae) and venous flows. Simulations of average jugular and vertebral blood flow variations due to a change of posture from supine to upright also matched the experimental data. CONCLUSIONS: The good agreement between simulated and experimental results means that the model can correctly reproduce the main factors affecting the extracranial circulation and could be used to study other types of stenotic conditions not represented by the experimental data.

16.
Med Phys ; 32(12): 3755-66, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16475775

RESUMO

Dual-energy mammographic imaging experimental tests have been performed using a compact dichromatic imaging system based on a conventional x-ray tube, a mosaic crystal, and a 384-strip silicon detector equipped with full-custom electronics with single photon counting capability. For simulating mammal tissue, a three-component phantom, made of Plexiglass, polyethylene, and water, has been used. Images have been collected with three different pairs of x-ray energies: 16-32 keV, 18-36 keV, and 20-40 keV. A Monte Carlo simulation of the experiment has also been carried out using the MCNP-4C transport code. The Alvarez-Macovski algorithm has been applied both to experimental and simulated data to remove the contrast between two of the phantom materials so as to enhance the visibility of the third one.


Assuntos
Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Silício , Algoritmos , Fenômenos Biofísicos , Biofísica , Feminino , Humanos , Mamografia/estatística & dados numéricos , Método de Monte Carlo , Imagens de Fantasmas/estatística & dados numéricos
17.
Phys Med Biol ; 50(10): 2225-40, 2005 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-15876663

RESUMO

Improvement in image contrast and dose reduction, in mammographic x-ray imaging, can be achieved using narrow energy band x-ray beams in the 16-24 keV range. As part of an Italian Government funded project, a quasi-monochromatic system for mammography applications has been developed. The system is based on a tunable narrow energy band x-ray source operating in the 16-24 keV energy range. The bremsstrahlung beam is monochromatized via Bragg diffraction by a highly oriented pyrolytic graphite mosaic crystal (HOPG). The scanning system provides a large field (18 x 24 cm2) of quasi-monochromatic x-rays with energy resolution ranging from 10% at 18 keV to 17.2% at 24 keV. The system has been characterized in terms of fluence rate and energy resolution. An x-ray tube developed ad hoc allows us to acquire images in a reasonable time to minimize the motion blur. A qualitative analysis has been performed in order to know if the prototype system performances are far from a clinical application, by evaluating the spatial resolution, the field uniformity and the image quality as a function of the quasi-monochromatic beam energy. Dose evaluation has been performed as a function of the energy and compared to a conventional system for mammography. The quasi-monochromatic prototype system can produce comparable image quality at half the dose.


Assuntos
Mamografia/instrumentação , Proteção Radiológica/métodos , Radiometria , Medição de Risco/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Imagens de Fantasmas , Projetos Piloto , Doses de Radiação , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade
18.
Artigo em Inglês | MEDLINE | ID: mdl-26738101

RESUMO

Alterations in the extracranial venous circulation due to posture changes, and/or extracranial venous obstructions in patients with vascular diseases, can have important implications on cerebral hemodynamics. A hemodynamic model for the study of cerebral venous outflow was developed to investigate the correlations between extracranial blood redistributions and changes in the intracranial environment. Flow data obtained with both magnetic resonance (MR) and Echo-Color Doppler (ECD) technique are used to validate the model. The very good agreement between simulated supine and upright flows and experimental results means that the model can correctly reproduce the main factors affecting the extracranial venous circulation.


Assuntos
Veias Cerebrais/fisiologia , Circulação Cerebrovascular , Algoritmos , Velocidade do Fluxo Sanguíneo , Drenagem , Humanos , Modelos Cardiovasculares , Postura
19.
Med Phys ; 28(4): 412-8, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11339737

RESUMO

A novel x-ray source for mammography application is being investigated. Quasimonochromatic x rays have been produced via Bragg diffraction with a W-anode x-ray tube and a graphite mosaic crystal array. The system provides 18 keV x rays with an energy resolution deltaE/E approximately equals 0.12. A thorough analysis of the spatial resolution of the system has been performed in order to understand and quantify the effect of the introduction of an active optical element such as a mosaic crystal in the x-ray path. The focal spot of the source and its emission properties have been studied by using the slit camera method. Experiments have shown that the introduction of a mosaic crystal in the optical path modifies the resolution properties of the Bragg diffraction-based radiography system. Along the direction perpendicular to the diffraction plane the resolution properties of the imaging system mainly depend on the x-ray tube focal spot size and position. Along the diffraction plane the focal spot size depends on mosaic characteristics and on the geometrical setup. Hence, it could be modified by setting the appropriate experimental conditions.


Assuntos
Mamografia/instrumentação , Raios X , Modelos Teóricos
20.
Med Phys ; 16(1): 94-7, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2921988

RESUMO

A radiation probe was designed for indirectly determining the high voltage of a Mo anode mammography unit. The real time processing of the probe outputs yields exposure time, voltage waveform, kVp, and ripple in the range 24-40 kVp useful for screen-film mammography. The probe, connected to a portable computer, will be employed in a survey of radiation dose and image quality in mammography as part of an ongoing program in Italy.


Assuntos
Mamografia/instrumentação , Eletrodos , Humanos , Molibdênio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA