Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
MAGMA ; 36(2): 309-315, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36752933

RESUMO

PURPOSE: In this study, we aimed to measure the apparent diffusion coefficients (ADCs) of major phosphorous metabolites in the human calf muscle at 7 T with a diffusion-weighted (DW)-STEAM sequence. METHODS: A DW-STEAM sequence with bipolar gradients was implemented at 7 T, and DW MR spectra were acquired in three orthogonal directions in the human calf muscle of six healthy volunteers (TE/TM/TR = 15 ms/750 ms/5 s) at three b-values (0, 800, and 1200 s/mm2). Frequency and phase alignments were applied prior to spectral averaging. Averaged DW MR spectra were analyzed with LCModel, and ADCs of 31P metabolites were estimated. RESULTS: Four metabolites (phosphocreatine (PCr), adenosine triphosphate (ATP), inorganic phosphate (Pi) and glycerol phosphorylcholine (GPC)) were quantified at all b-values with mean CRLBs below 10%. The ADC values of PCr, ATP, Pi, and GPC were (0.24 ± 0.02, 0.15 ± 0.04, 0.43 ± 0.14, 0.40 ± 0.09) × 10-3 mm2/s, respectively. CONCLUSION: The ADCs of four 31P metabolites were successfully measured in the human calf muscle at 7 T, among which those of ATP, Pi and GPC were reported for the first time in humans. This study paves the way to investigate 31P metabolite diffusion properties in health and disease on the clinical MR scanner.


Assuntos
Imagem de Difusão por Ressonância Magnética , Músculo Esquelético , Humanos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/metabolismo , Fósforo , Trifosfato de Adenosina/metabolismo , Fosfatos
2.
MAGMA ; 36(5): 837-847, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36715885

RESUMO

OBJECTIVES: To access the performances of different algorithms for quantification of Intravoxel incoherent motion (IVIM) parameters D, f, [Formula: see text] in Vertebral Bone Marrow (VBM). MATERIALS AND METHODS: Five algorithms were studied: four deterministic algorithms (the One-Step and three segmented methods: Two-Step, Three-Step, and Fixed-[Formula: see text] algorithm) based on the least-squares (LSQ) method and a Bayesian probabilistic algorithm. Numerical simulations and quantification of IVIM parameters D, f, [Formula: see text] in vivo in vertebral bone marrow, were done on six healthy volunteers. The One-way repeated-measures analysis of variance (ANOVA) followed by Bonferroni's multiple comparison test (p value = 0.05) was applied. RESULTS: In numerical simulations, the Bayesian algorithm provided the best estimation of D, f, [Formula: see text] compared to the deterministic algorithms. In vivo VBM-IVIM, the values of D and f estimated by the Bayesian algorithm were close to those of the One-Step method, in contrast to the three segmented methods. DISCUSSION: The comparison of the five algorithms indicates that the Bayesian algorithm provides the best estimation of VBM-IVIM parameters, in both numerical simulations and in vivo data.


Assuntos
Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Medula Óssea/diagnóstico por imagem , Teorema de Bayes , Algoritmos , Movimento (Física)
3.
MAGMA ; 36(5): 823-836, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36847989

RESUMO

OBJECTIVE: The Fluid And White matter Suppression (FLAWS) MRI sequence provides multiple T1-weighted contrasts of the brain in a single acquisition. However, the FLAWS acquisition time is approximately 8 min with a standard GRAPPA 3 acceleration factor at 3 T. This study aims at reducing the FLAWS acquisition time by providing a new sequence optimization based on a Cartesian phyllotaxis k-space undersampling and a compressed sensing (CS) reconstruction. This study also aims at showing that T1 mapping can be performed with FLAWS at 3 T. MATERIALS AND METHODS: The CS FLAWS parameters were determined using a method based on a profit function maximization under constraints. The FLAWS optimization and T1 mapping were assessed with in-silico, in-vitro and in-vivo (10 healthy volunteers) experiments conducted at 3 T. RESULTS: In-silico, in-vitro and in-vivo experiments showed that the proposed CS FLAWS optimization allows the acquisition time of a 1 mm-isotropic full-brain scan to be reduced from [Formula: see text] to [Formula: see text] without decreasing image quality. In addition, these experiments demonstrate that T1 mapping can be performed with FLAWS at 3 T. DISCUSSION: The results obtained in this study suggest that the recent advances in FLAWS imaging allow to perform multiple T1-weighted contrast imaging and T1 mapping in a single [Formula: see text] sequence acquisition.


Assuntos
Substância Branca , Humanos , Substância Branca/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Neuroimagem , Cabeça , Processamento de Imagem Assistida por Computador
4.
J Comput Assist Tomogr ; 46(1): 110-115, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35099142

RESUMO

OBJECTIVE: This initial study aimed to investigate the feasibility of simultaneously measuring perfusion and diffusion including kurtosis features in acute ischemic stroke with the combined intravoxel incoherent motion and non-Gaussian diffusional kurtosis imaging (DKI-IVIM). MATERIAL AND METHODS: Five ischemic stroke patients underwent a 4-minute diffusion weighted imaging (DWI) protocol, using 8 b values chosen with the Cramer-Rao-Lower-Bound optimization approach, in addition to conventional DWI and arterial spin labeling sequences. Regions of interest in pathological and control regions were analyzed with DKI-IVIM, and parametric maps were reconstructed. RESULTS: The IVIM diffusion coefficient (D) decreased (P < 0.0001) in the infarcted areas, whereas higher kurtosis coefficient values were found (P = 0.0002). Regarding the perfusion, the individual IVIM perfusion fraction f decreased in 3 matching cases with the cerebral blood flow estimated through arterial spin labeling and the fD* decreased only in 2 patients of those. CONCLUSIONS: When compared with conventional stroke imaging protocol, DKI-IVIM 4-minute 2-in-1 acquisition can provide diffusion results comparable with conventional DWI with complementary kurtosis estimations but a limited robustness regarding perfusion estimations for clinical purpose.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador , Idoso , Idoso de 80 Anos ou mais , Encéfalo/diagnóstico por imagem , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
Magn Reson Med ; 85(3): 1364-1378, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32989788

RESUMO

PURPOSE: To demonstrate that fluid and white matter suppression (FLAWS) imaging can be used for high-resolution T1 mapping with low transmitted bias field ( B1+ ) sensitivity at 7T. METHODS: The FLAWS sequence was optimized for 0.8-mm isotropic resolution imaging. The theoretical accuracy and precision of the FLAWS T1 mapping was compared with the one of the magnetization-prepared two rapid gradient echoes (MP2RAGE) sequence optimized for low B1+ sensitivity. FLAWS images were acquired at 7T on six healthy volunteers (21 to 48 years old; two women). MP2RAGE and saturation-prepared with two rapid gradient echoes (SA2RAGE) datasets were also acquired to obtain T1 mapping references and B1+ maps. The contrast-to-noise ratio (CNR) between brain tissues was measured in the FLAWS-hco and MP2RAGE-uni images. The Pearson correlation was measured between the MP2RAGE and FLAWS T1 maps. The effect of B1+ on FLAWS T1 mapping was assessed using the Pearson correlation. RESULTS: The FLAWS-hco images were characterized by a higher brain tissue CNR ( CNRWM/GM=5.5 , CNRWM/CSF=14.7 , CNRGM/CSF=10.3 ) than the MP2RAGE-uni images ( CNRWM/GM=4.9 , CNRWM/CSF=6.6 , CNRGM/CSF=3.7 ). The theoretical accuracy and precision of the FLAWS T1 mapping ( acc=91.9%;prec=90.2% ) were in agreement with those provided by the MP2RAGE T1 mapping ( acc=90.0%;prec=86.8% ). A good agreement was found between in vivo T1 values measured with the MP2RAGE and FLAWS sequences (r = 0.91). A weak correlation was found between the FLAWS T1 map and the B1+ map within cortical gray matter and white matter segmentations ( rWM=-0.026 ; rGM=0.081 ). CONCLUSION: The results from this study suggest that FLAWS is a good candidate for high-resolution T1 -weighted imaging and T1 mapping at the field strength of 7T.


Assuntos
Substância Branca , Adulto , Encéfalo/diagnóstico por imagem , Feminino , Substância Cinzenta/diagnóstico por imagem , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Substância Branca/diagnóstico por imagem , Adulto Jovem
6.
MAGMA ; 34(5): 729-740, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33709226

RESUMO

OBJECTIVE: MRI is a reliable and accurate technique to characterize rheumatoid arthritis. The aim of this study was to provide voxel-by-voxel 3D maps of the proton density fat fraction (PDFF), the T1 of water (T1W), the T1 of fat (T1F), the T2* of water (T2*W), the T2* of fat (T2*F) in the wrist bone marrow. MATERIALS AND METHODS: The experiments were conducted on 14 healthy volunteers (mean age: 24 ± 4). The data were acquired at 1.5 T using two optimized four-echo 3D 1.2 × 1.2 × 1.2 mm3-isotropic spoiled gradient sequences. A repeatability study was carried out. The measurements were done using a homemade parametric viewer software. RESULTS: The inter-volunteer results were, on average: PDFF = 86 ± 3%, T1W = 441 ± 113 ms, T1F = 245 ± 19 ms, T2*W = 6 ± 1 ms and T2*F = 16 ± 3 ms. The coefficients of variation were for fat based biomarkers CVPDFF < 5%, CVT1F < 15% and CVT2*F < 10% in the repeatability study. DISCUSSION: The protocol and quantification tool proposed in this study provide high-resolution voxel-by-voxel 3D maps of five biomarkers in the wrist in less than 4 min of acquisition.


Assuntos
Medula Óssea , Punho , Adulto , Biomarcadores , Medula Óssea/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Água , Adulto Jovem
7.
J Magn Reson Imaging ; 49(3): 768-776, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30194746

RESUMO

BACKGROUND: A limited number of studies have used the intravoxel incoherent motion (IVIM) approach on bone marrow. In none of the previous studies were the effects of fat suppression on the IVIM parameters investigated. PURPOSE: To measure the water diffusion coefficient and the perfusion fraction in vertebral bone marrow using IVIM with multishot, readout-segmented (RESOLVE) echo-planar imaging and to assess the effects of different fat suppression techniques on the measurement of the IVIM parameters. STUDY TYPE: Prospective. POPULATION/SUBJECTS: Six healthy volunteers (24.2 ± 4.3 years). FIELD STRENGTH/SEQUENCE: 1.5T, RESOLVE. ASSESSMENT: Four experiments were performed: 1) RESOLVE imaging without fat suppression, 2) with fat saturation (FS), 3) with spectral attenuated inversion recovery (SPAIR), and 4) with short-tau inversion recovery (STIR). The water diffusion coefficient D, pseudo-diffusion coefficient D*, and the perfusion fraction f were assessed in the vertebral bodies of the lumbar vertebrae. STATISTICAL TESTS: One-way repeated-measures analysis of variance (ANOVA) followed by Bonferroni's multiple comparison test. RESULTS: The RESOLVE IVIM protocol allowed for measurement of D, D*, and f in all volunteers. The signal of lipid protons affected the quantification of the IVIM diffusion coefficient: D = 0.24 ± 0.10 (×10-3 mm2 /s), no FS; D = 0.43 ± 0.07 (×10-3 mm2 /s), FS; D = 0.42 ± 0.07 (×10-3 mm2 /s), SPAIR; D = 0.35 ± 0.10 (×10-3 mm2 /s), STIR; and IVIM perfusion fraction f = 7.5 ± 1.9% no FS, f = 14.5 ± 5.4%, FS; f = 12.5 ± 2.6%, SPAIR; f = 18.1 ± 6.1%, STIR. No significant effect (P = 0.36) was found on the quantification of D*. DATA CONCLUSION: An IVIM-MRI protocol using the RESOLVE sequence was implemented for measurements of vertebral bone marrow diffusion and the perfusion. The comparison between the protocols with and without fat suppression indicates that the lipid signal results in an underestimation of both D and f. LEVEL OF EVIDENCE: Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2019;49:768-776.


Assuntos
Medula Óssea/diagnóstico por imagem , Imagem Ecoplanar , Coluna Vertebral/diagnóstico por imagem , Tecido Adiposo/diagnóstico por imagem , Adulto , Algoritmos , Imagem de Difusão por Ressonância Magnética , Feminino , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Movimento (Física) , Perfusão , Estudos Prospectivos , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Adulto Jovem
8.
NMR Biomed ; 31(9): e3991, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30040156

RESUMO

INTRODUCTION: The composition of fatty acids in the body is gaining increasing interest, and can be followed up noninvasively by quantitative magnetic resonance spectroscopy (MRS). However, current MRS quantification methods have been shown to provide different quantitative results in terms of lipid signals, with possible varying outcomes for a given biological examination. Quantitative magnetic resonance imaging using multigradient echo sequence (MGE-MRI) has recently been added to MRS approaches. In contrast, these methods fit the undersampled magnetic resonance temporal signal with a simplified model function (expressing the triglyceride [TG] spectrum with only three TG parameters), specific implementations and prior knowledge. In this study, an adaptation of an MGE-MRI method to MRS lipid quantification is proposed. METHODS: Several versions of the method - with time data fully or undersampled, including or excluding the spectral peak T2 knowledge in the fitting - were compared theoretically and on Monte Carlo studies with a time-domain, peak-fitting approach. Robustness, repeatability and accuracy were also inspected on in vitro oil acquisitions and test-retest in vivo subcutaneous adipose tissue acquisitions, adding results from the reference LCModel method. RESULTS: On simulations, the proposed method provided TG parameter estimates with the smallest variability, but with a possible bias, which was mitigated by fitting on undersampled data and considering peak T2 values. For in vitro measurements, estimates for all approaches were correlated with theoretical values and the best concordance was found for the usual MRS method (LCModel and peak fitting). Limited in vivo test-retest variability was found (4.1% for PUFAindx, 0.6% for MUFAindx and 3.6% for SFAindx), as for LCModel (7.6% for PUFAindx, 7.8% for MUFAindx and 3.0% for SFAindx). CONCLUSION: This study shows that fitting the three TG parameters directly on MRS data is one valuable solution to circumvent the poor conditioning of the MRS quantification problem.


Assuntos
Ácidos Graxos/análise , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Processamento de Sinais Assistido por Computador , Tecido Adiposo/metabolismo , Adulto , Simulação por Computador , Humanos , Masculino , Método de Monte Carlo
9.
J Magn Reson Imaging ; 47(6): 1646-1653, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29135073

RESUMO

BACKGROUND: T2 -weighted imaging (T2 -WI) information has been used in a qualitative manner in the assessment of prostate cancer. Quantitative derivatives (T2 relaxation time) can be generated from T2 -WI. These outputs may be useful in helping to discriminate clinically significant prostate cancer from background signal. PURPOSE/HYPOTHESIS: To investigate changes in quantitative T2 parameters in lesions and noncancerous tissue of men on active surveillance for prostate cancer taking dutasteride 0.5 mg or placebo daily for 6 months. STUDY TYPE: Retrospective. POPULATION/SUBJECTS: Forty men randomized to 6 months of daily dutasteride (n = 20) or placebo (n = 20). FIELD STRENGTH/SEQUENCE: Multiparametric 3T MRI at baseline and 6 months. This included a multiecho MR sequence for quantification of the T2 relaxation times, in three regions of interest (index lesion, noncancerous peripheral [PZ] and transitional [TZ] zones). A synthetic signal contrast (T2 Q contrast) between lesion and noncancerous tissue was assessed using quantitative T2 values. Signal contrast was calculated using the T2 -weighted sequence (T2 W contrast). ASSESSMENT: Two radiologists reviewed the scans in consensus according to Prostate Imaging Reporting and Data System (PI-RADS v. 2) guidelines. STATISTICAL TESTS: Wilcoxon and Mann-Whitney U-tests, Spearman's correlation. RESULTS: When compared to noncancerous tissue, shorter T2 values were observed within lesions at baseline (83.5 and 80.5 msec) and 6 months (81.5 and 81.9 msec) in the placebo and dutasteride arm, respectively. No significant differences for T2 W contrast at baseline and after 6 months were observed, both in the placebo (0.40 [0.29-0.49] vs. 0.43 [0.25-0.49]; P = 0.881) and dutasteride arm (0.35 [0.24-0.47] vs. 0.37 [0.22-0.44]; P = 0.668). There was a significant, positive correlation between the T2 Q contrast and the T2 W contrast values (r = 0.786; P < 0.001). DATA CONCLUSION: The exposure to antiandrogen therapy did not significantly influence the T2 contrast or the T2 relaxation values in men on active surveillance for prostate cancer. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1646-1653.


Assuntos
Inibidores de 5-alfa Redutase/uso terapêutico , Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Antagonistas de Androgênios/uso terapêutico , Biomarcadores Tumorais , Método Duplo-Cego , Dutasterida/uso terapêutico , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Próstata/diagnóstico por imagem , Estudos Retrospectivos
10.
J Comput Assist Tomogr ; 42(1): 85-91, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28708726

RESUMO

OBJECTIVES: The aim of this study was to demonstrate the feasibility to assess cerebral hypoperfusion with a hyperventilation (HV) challenge protocol using intravoxel incoherent motion (IVIM) magnetic resonance imaging. MATERIALS AND METHODS: Magnetic resonance imaging experiments were performed on 10 healthy volunteers at 1.5 T, with a diffusion IVIM magnetic resonance imaging protocol using a set of b-values optimized by Cramer-Rao Lower Bound analysis. Hypoperfusion was induced by an HV maneuver. Measurements were performed in normoventilation and HV conditions. Biexponential curve fitting was used to obtain the perfusion fraction (f), pseudodiffusion coefficient (D*), and the product fD* in gray matter (GM) regions of interest (ROIs). Regional cerebral blood flow in the same ROIs was also assessed with arterial spin labeling. RESULTS: The HV challenge led to a diminution of IVIM perfusion-related parameters, with a decrease of f and fD* in the cerebellum (P = 0.03 for f; P = 0.01 for fD*), thalamus GM (P = 0.09 for f; P = 0.01 for fD*), and lenticular nuclei (P = 0.03 for f; P = 0.02 for fD*). Mean GM cerebral blood flow (in mL/100 g tissue/min) measured with arterial spin labeling averaged over all ROIs also decreased (normoventilation: 42.7 ± 4.1 vs HV: 33.2 ± 2.2, P = 0.004) during the HV challenge. CONCLUSIONS: The optimized IVIM protocol proposed in the current study allows for measurements of cerebral hypoperfusion that might be of great interest for pathologies diagnosis such as ischemic stroke.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/fisiopatologia , Imagem de Difusão por Ressonância Magnética/métodos , Hiperventilação/fisiopatologia , Adulto , Estudos de Viabilidade , Feminino , Voluntários Saudáveis , Humanos , Masculino
11.
Magn Reson Med ; 77(1): 310-317, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-26728917

RESUMO

PURPOSE: Tissue perfusion measurements using intravoxel incoherent motion (IVIM) diffusion-MRI are of interest for investigations of liver pathologies. A confounding factor in the perfusion quantification is the partial volume between liver tissue and large blood vessels. The aim of this study was to assess and correct for this partial volume effect in the estimation of the perfusion fraction. METHODS: MRI experiments were performed at 3 Tesla with a diffusion-MRI sequence at 12 b-values. Diffusion signal decays in liver were analyzed using the non-negative least square (NNLS) method and the biexponential fitting approach. RESULTS: In some voxels, the NNLS analysis yielded a very fast-decaying component that was assigned to partial volume with the blood flowing in large vessels. Partial volume correction was performed by biexponential curve fitting, where the first data point (b = 0 s/mm2 ) was eliminated in voxels with a very fast-decaying component. Biexponential fitting with partial volume correction yielded parametric maps with perfusion fraction values smaller than biexponential fitting without partial volume correction. CONCLUSION: The results of the current study indicate that the NNLS analysis in combination with biexponential curve fitting allows to correct for partial volume effects originating from blood flow in IVIM perfusion fraction measurements. Magn Reson Med 77:310-317, 2017. © 2016 Wiley Periodicals, Inc.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Algoritmos , Humanos , Fígado/irrigação sanguínea
12.
J Urol ; 197(4): 1006-1013, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27871928

RESUMO

PURPOSE: Dutasteride, which is licensed for symptomatic benign prostatic hyperplasia, has been associated with a lower progression rate of low risk prostate cancer. We evaluated the effect of dutasteride on prostate cancer volume as assessed by T2-weighted magnetic resonance imaging. MATERIALS AND METHODS: In this randomized, double-blind, placebo controlled trial, men with biopsy proven, low-intermediate risk prostate cancer (up to Gleason 3 + 4 and PSA up to 15 ng/ml) who had visible lesion of 0.2 ml or greater on T2-weighted magnetic resonance imaging sequences were randomized to daily dutasteride 0.5 mg or placebo for 6 months. Lesion volume was assessed at baseline, and 3 and 6 months with image guided biopsy to the lesion at study exit. The primary end point was the percent reduction in lesion volume over 6 months. This trial was registered with the European Clinical Trials register (EudraCT 2009-102405-18). RESULTS: A total of 42 men were recruited between June 2010 and January 2012. In the dutasteride group, the average volumes at baseline and 6 months were 0.55 and 0.38 ml, respectively and the average reduction was 36%. In the placebo group, the average volumes at baseline and 6 months were 0.65 and 0.76 ml, respectively, and the average reduction was -12%. The difference in percent reductions between the groups was 48% (95% CI 27.4-68.3, p <0.0001). The most common adverse event was deterioration in erectile function, which was 25% in men randomized to dutasteride and 16% in men randomized to placebo. CONCLUSIONS: Dutasteride was associated with a significant reduction in prostate cancer volume on T2-weighted magnetic resonance imaging compared to placebo.


Assuntos
Inibidores de 5-alfa Redutase/uso terapêutico , Dutasterida/uso terapêutico , Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/tratamento farmacológico , Inibidores de 5-alfa Redutase/farmacologia , Adulto , Idoso , Método Duplo-Cego , Dutasterida/farmacologia , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/patologia , Carga Tumoral/efeitos dos fármacos
13.
Anal Biochem ; 529: 65-78, 2017 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-27596743

RESUMO

Magnetic resonance spectroscopy (MRS) is a well established modality for investigating tissue metabolism in vivo. In recent years, many efforts by the scientific community have been directed towards the improvement of metabolite detection and quantitation. Quantum mechanics simulations allow for investigations of the MR signal behaviour of metabolites; thus, they provide an essential tool in the optimization of metabolite detection. In this review, we will examine quantum mechanics simulations based on the density matrix formalism. The density matrix was introduced by von Neumann in 1927 to take into account statistical effects within the theory of quantum mechanics. We will discuss the main steps of the density matrix simulation of an arbitrary spin system and show some examples for the strongly coupled two spin system.


Assuntos
Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Metaboloma , Metabolômica/métodos , Teoria Quântica , Animais , Humanos
14.
Eur Radiol ; 27(11): 4767-4774, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28523355

RESUMO

OBJECTIVES: To investigate changes in the Apparent Diffusion Coefficient (ADC) using diffusion-weighted imaging (DWI) in men on active surveillance for prostate cancer taking dutasteride 0.5 mg or placebo. METHODS: We analysed 37 men, randomised to 6 months of daily dutasteride (n = 18) or placebo (n = 19), undergoing 3T multi-parametric Magnetic Resonance Imaging (mpMRI) scans at baseline and 6 months. Images were reviewed blind to treatment allocation and clinical information. Mean ADC of peripheral (PZ) and transition (TZ) zones, and MR-suspicious lesions were compared between groups over 6 months. Conspicuity was defined as the PZ divided by tumour ADC, and its change over 6 months was assessed. RESULTS: A decrease in mean conspicuity in the dutasteride group (but not the controls) was seen over 6 months (1.54 vs 1.38; p = 0.025). Absolute changes in ADC and conspicuity were significantly different between placebo and dutasteride groups at 6 months: (-0.03 vs 0.08, p = 0.033) and (0.11 vs -0.16, p = 0.012), as were percentage changes in the same parameters: (-2.27% vs 8.56% p = 0.048) and (9.25% vs -9.89% p = 0.013). CONCLUSIONS: Dutasteride was associated with increased tumour ADC and reduced conspicuity. A lower threshold for triggering biopsy might be considered in men on dutasteride undergoing mpMRI for prostate cancer. KEY POINTS: • Dutasteride increases ADC and reduces conspicuity in small mpMRI-visible prostate cancers. • Knowledge of dutasteride exposure is important in the interpretation of prostate mpMRI. • A lower threshold for triggering biopsy may be appropriate on dutasteride.


Assuntos
Inibidores de 5-alfa Redutase/uso terapêutico , Imagem de Difusão por Ressonância Magnética , Dutasterida/uso terapêutico , Neoplasias da Próstata/diagnóstico por imagem , Idoso , Biópsia , Humanos , Masculino , Pessoa de Meia-Idade , Hiperplasia Prostática/tratamento farmacológico , Neoplasias da Próstata/patologia
15.
MAGMA ; 30(6): 545-554, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28608327

RESUMO

OBJECTIVES: The objectives were to investigate the diffusional kurtosis imaging (DKI) incorporation into the intravoxel incoherent motion (IVIM) model for measurements of cerebral hypoperfusion in healthy subjects. MATERIALS AND METHODS: Eight healthy subjects underwent a hyperventilation challenge with a 4-min diffusion weighted imaging protocol, using 8 b values chosen with the Cramer-Rao Lower Bound optimization approach. Four regions of interest in gray matter (GM) were analyzed with the DKI-IVIM model and the bi-exponential IVIM model, for normoventilation and hyperventilation conditions. RESULTS: A significant reduction in the perfusion fraction (f) and in the product fD* of the perfusion fraction with the pseudodiffusion coefficient (D*) was found with the DKI-IVIM model, during the hyperventilation challenge. In the cerebellum GM, the percentage changes were f: -43.7 ± 40.1, p = 0.011 and fD*: -50.6 ± 32.1, p = 0.011; in thalamus GM, f: -47.7 ± 34.7, p = 0.012 and fD*: -47.2 ± 48.7, p = 0.040. In comparison, using the bi-exponential IVIM model, only a significant decrease in the parameter fD* was observed for the same regions of interest. In frontal-GM and posterior-GM, the reduction in f and fD* did not reach statistical significance, either with DKI-IVIM or the bi-exponential IVIM model. CONCLUSION: When compared to the bi-exponential IVIM model, the DKI-IVIM model displays a higher sensitivity to detect changes in perfusion induced by the hyperventilation condition.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Hiperventilação/diagnóstico por imagem , Adulto , Volume Sanguíneo Cerebral , Circulação Cerebrovascular , Imagem de Difusão por Ressonância Magnética/estatística & dados numéricos , Imagem Ecoplanar/métodos , Imagem Ecoplanar/estatística & dados numéricos , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Masculino , Movimento (Física) , Imagem de Perfusão/métodos , Imagem de Perfusão/estatística & dados numéricos
16.
J Magn Reson Imaging ; 44(3): 549-55, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26918280

RESUMO

PURPOSE: To assess the feasibility of measuring the fat fraction, T1 and T2 * relaxation times of water and fat signals in vertebral bone marrow using breath-hold magnetic resonance imaging (MRI) gradient echo images of the spine. MATERIALS AND METHODS: MRI experiments were performed at 1.5T on eight healthy volunteers (35.1 ± 15.7 years, five men and three women) using two sagittal four-echo 3D gradient echo volumetric interpolated breath-hold examination (VIBE Dixon) sequences acquired at two different flip angles (5° and 15°). The water/fat decomposition was performed in the vertebral bodies of L1 to L5 by fitting the signal to a function that depends on the echo time and the flip angle to calculate the fat fraction (FF) and T1 and T2 * relaxation times of water and fat signals. Repeatability was assessed by scanning one volunteer six times. RESULTS: The mean fat fraction over L1 to L5 was 33 ± 8%. The mean T1 and T2 * of water and fat signals were respectively T1w = 701 ± 151 msec, T2 *w = 13.7 ± 2.9 msec, T1f = 334 ± 113 msec, and T2 *f = 11.4 ± 2.7 msec. When considering each vertebra separately, the fat fraction increased from L1 to L5 and the T1w decreased from L1 to L5. The mean coefficients of variation obtained from the repeatability study were 8% (FF), 11% (T1w ), 17% (T1f ), 8% (T2 *w ), and 27% (T2 *f ). CONCLUSION: The method introduced in the current study allows for the measurement of the fat fraction and water and fat relaxation times, with a total acquisition time of less than 40 seconds. J. Magn. Reson. Imaging 2016;44:549-555.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Água Corporal/diagnóstico por imagem , Medula Óssea/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo/fisiologia , Adiposidade/fisiologia , Adulto , Água Corporal/fisiologia , Medula Óssea/fisiologia , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Vértebras Lombares/fisiologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Mecânica Respiratória , Sensibilidade e Especificidade , Adulto Jovem
17.
MAGMA ; 29(1): 1-4, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26724927

RESUMO

OBJECTIVE: To evaluate the feasibility of in vivo measurement of the fatty acid (FA) composition of breast adipose tissue by MRS on a clinical platform. MATERIAL AND METHODS: MRS experiments were performed at 3 T, using a STEAM sequence, on 25 patients diagnosed with breast cancer. MR spectra, acquired on healthy breast tissue, were analysed with the LCModel. RESULTS: The measured values of the saturated fatty acid (SFA), mono-unsaturated fatty acid (MUFA) and poly-unsaturated fatty acid (PUFA) fractions were 23.8 ± 7.1%, 55.4 ± 6.8% and 20.8 ± 4.4%, respectively. The values of SFA, MUFA and PUFA observed in the current study are in the same range as those found in two previous studies performed at 7 T. CONCLUSION: The results of the current study show that it is possible to quantify the fatty acid composition of breast tissue in vivo in a clinical setting (3 T).


Assuntos
Mama/diagnóstico por imagem , Ácidos Graxos/química , Espectroscopia de Ressonância Magnética , Tecido Adiposo/química , Idoso , Biomarcadores Tumorais/química , Mama/química , Mama/patologia , Ácidos Graxos Monoinsaturados/química , Ácidos Graxos Insaturados/química , Feminino , Humanos , Pessoa de Meia-Idade , Software
18.
MAGMA ; 29(1): 29-37, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26590825

RESUMO

OBJECTIVE: To investigate the effect of water suppression on the hepatic lipid quantification, using the LCModel. MATERIALS AND METHODS: MR spectra with and without water suppression were acquired in the liver of mice at 4.7 T and patients at 3 T, and processed with the LCModel. The Cramér-Rao Lower Bound (CRLB) values of the seven lipid resonances were determined to assess the impact of water suppression on hepatic lipid quantification. A paired t test was used for comparison between the CRLBs obtained with and without water suppression. RESULTS: For the preclinical data, in the high (low) fat fraction subset an overall impairment in hepatic lipid quantification, i.e. an increase of CRLBs (no significant change of CRLBs) was observed in spectra acquired with water suppression. For the clinical data, there were no substantial changes in the CRLB with water suppression. Because (1) the water suppression does not overall improve the quantification of the lipid resonances and (2) the MR spectrum without water suppression is always acquired for fat fraction calculation, the optimal data-acquisition strategy for liver MRS is to acquire only the MR spectrum without water suppression. CONCLUSION: For quantification of hepatic lipid resonances, it is advantageous to perform MR spectroscopy without water suppression in a clinical and preclinical scenario (at moderate fields).


Assuntos
Lipídeos/química , Fígado/diagnóstico por imagem , Espectroscopia de Ressonância Magnética/métodos , Água/química , Animais , Biomarcadores/química , Diagnóstico por Imagem/métodos , Fígado Gorduroso/diagnóstico por imagem , Feminino , Fígado/química , Camundongos , Camundongos Endogâmicos C57BL
19.
Muscle Nerve ; 51(2): 214-21, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24831173

RESUMO

INTRODUCTION: Chronic obstructive pulmonary disease (COPD) is associated with metabolic abnormalities in muscles of the lower limbs, but it is not known whether these abnormalities are generalized or limited to specific muscle groups, nor is there an easy way of predicting their presence. METHODS: Metabolism in the quadriceps and biceps of 14 COPD patients and controls was assessed during sustained contraction using 31-phosphorus magnetic resonance spectroscopy ((31) P MRS). T1 MRI was used to measure quadriceps intermuscular adipose tissue (IMAT). RESULTS: COPD patients had prolonged quadriceps phosphocreatine time (patients: 38.8 ± 12.7 s; controls: 25.2 ± 10.6 s; P = 0.006) and a lower pH (patents: 6.88 ± 0.1; controls: 6.99 ± 0.06; P = 0.002). Biceps measures were not significantly different. IMAT was associated with a nadir pH <7.0 (area under the curve = 0.84). CONCLUSIONS: Anaerobic metabolism during contraction was characteristic of quadriceps, but not biceps, muscles of patients with COPD and was associated with increased IMAT. Because IMAT can be assessed quickly by conventional MRI, it may be a useful approach for identifying patients with abnormal muscle bioenergetics.


Assuntos
Metabolismo Energético , Gorduras/metabolismo , Doença Pulmonar Obstrutiva Crônica/patologia , Músculo Quadríceps/fisiopatologia , Idoso , Exercício Físico , Feminino , Volume Expiratório Forçado/fisiologia , Humanos , Concentração de Íons de Hidrogênio , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Contração Muscular/fisiologia , Fosfocreatina/metabolismo , Isótopos de Fósforo , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Curva ROC , Índice de Gravidade de Doença
20.
MAGMA ; 27(5): 419-24, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24337393

RESUMO

OBJECT: The ability to generate reference signals is of great benefit for quantitation of the magnetic resonance (MR) signal. The aim of the present study was to implement a dedicated experimental set-up to generate MR images of virtual phantoms. MATERIALS AND METHODS: Virtual phantoms of a given shape and signal intensity were designed and the k-space representation was generated. A waveform generator converted the k-space lines into a radiofrequency (RF) signal that was transmitted to the MR scanner bore by a dedicated RF coil. The k-space lines of the virtual phantom were played line-by-line in synchronization with the magnetic resonance imaging data acquisition. RESULTS: Virtual phantoms of complex patterns were reproduced well in MR images without the presence of artifacts. Time-series measurements showed a coefficient of variation below 1% for the signal intensity of the virtual phantoms. An excellent linearity (coefficient of determination r (2) = 0.997 as assessed by linear regression) was observed in the signal intensity of virtual phantoms. CONCLUSION: Virtual phantoms represent an attractive alternative to physical phantoms for providing a reference signal. MR images of virtual phantoms were here generated using a stand-alone, independent unit that can be employed with MR scanners from different vendors.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Interface Usuário-Computador , Valores de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA