Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38587261

RESUMO

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Bioprótese/efeitos adversos , Insuficiência Cardíaca , Estimativa de Kaplan-Meier , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos
2.
Catheter Cardiovasc Interv ; 103(6): 1015-1022, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38577931

RESUMO

BACKGROUND: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients. AIMS: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness. METHODS: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second-generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow-up were compared between the two generations. RESULTS: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para-valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para-valvular regurgitation, which remained significant at 1 year. CONCLUSION: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Complicações Pós-Operatórias , Estudos Prospectivos , Recuperação de Função Fisiológica , Fatores de Risco , Espanha , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
Basic Res Cardiol ; 116(1): 4, 2021 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-33495853

RESUMO

Remote ischemic conditioning (RIC) and the GLP-1 analog exenatide activate different cardioprotective pathways and may have additive effects on infarct size (IS). Here, we aimed to assess the efficacy of RIC as compared with sham procedure, and of exenatide, as compared with placebo, and the interaction between both, to reduce IS in humans. We designed a two-by-two factorial, randomized controlled, blinded, multicenter, clinical trial. Patients with ST-segment elevation myocardial infarction receiving primary percutaneous coronary intervention (PPCI) within 6 h of symptoms were randomized to RIC or sham procedure and exenatide or matching placebo. The primary outcome was IS measured by late gadolinium enhancement in cardiac magnetic resonance performed 3-7 days after PPCI. The secondary outcomes were myocardial salvage index, transmurality index, left ventricular ejection fraction and relative microvascular obstruction volume. A total of 378 patients were randomly allocated, and after applying exclusion criteria, 222 patients were available for analysis. There were no significant interactions between the two randomization factors on the primary or secondary outcomes. IS was similar between groups for the RIC (24 ± 11.8% in the RIC group vs 23.7 ± 10.9% in the sham group, P = 0.827) and the exenatide hypotheses (25.1 ± 11.5% in the exenatide group vs 22.5 ± 10.9% in the placebo group, P = 0.092). There were no effects with either RIC or exenatide on the secondary outcomes. Unexpected adverse events or side effects of RIC and exenatide were not observed. In conclusion, neither RIC nor exenatide, or its combination, were able to reduce IS in STEMI patients when administered as an adjunct to PPCI.


Assuntos
Braço/irrigação sanguínea , Exenatida/uso terapêutico , Incretinas/uso terapêutico , Precondicionamento Isquêmico , Miocárdio/patologia , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Idoso , Terapia Combinada , Método Duplo-Cego , Exenatida/efeitos adversos , Feminino , Humanos , Incretinas/efeitos adversos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Fluxo Sanguíneo Regional , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/patologia , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Espanha , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
4.
Cardiovasc Diabetol ; 20(1): 69, 2021 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-33757510

RESUMO

BACKGROUND: During COVID-19 pandemic, elective invasive cardiac procedures (ICP) have been frequently cancelled or postponed. Consequences may be more evident in patients with diabetes. OBJECTIVES: The objective was to identify the peculiarities of patients with DM among those in whom ICP were cancelled or postponed due to the COVID-19 pandemic, as well as to identify subgroups in which the influence of DM has higher impact on the clinical outcome. METHODS: We included 2,158 patients in whom an elective ICP was cancelled or postponed during COVID-19 pandemic in 37 hospitals in Spain. Among them, 700 (32.4%) were diabetics. Patients with and without diabetes were compared. RESULTS: Patients with diabetes were older and had a higher prevalence of other cardiovascular risk factors, previous cardiovascular history and co-morbidities. Diabetics had a higher mortality (3.0% vs. 1.0%; p = 0.001) and cardiovascular mortality (1.9% vs. 0.4%; p = 0.001). Differences were especially important in patients with valvular heart disease (mortality 6.9% vs 1.7% [p < 0.001] and cardiovascular mortality 4.9% vs 0.9% [p = 0.002] in patients with and without diabetes, respectively). In the multivariable analysis, diabetes remained as an independent risk factor both for overall and cardiovascular mortality. No significant interaction was found with other clinical variables. CONCLUSION: Among patients in whom an elective invasive cardiac procedure is cancelled or postponed during COVID-19 pandemic, mortality and cardiovascular mortality is higher in patients with diabetes, irrespectively on other clinical conditions. These procedures should not be cancelled in patients with diabetes.


Assuntos
COVID-19 , Angiografia Coronária , Diabetes Mellitus , Cardiopatias/diagnóstico por imagem , Cardiopatias/terapia , Intervenção Coronária Percutânea , Tempo para o Tratamento , Listas de Espera , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Bases de Dados Factuais , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Feminino , Cardiopatias/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Medição de Risco , Fatores de Risco , Espanha/epidemiologia , Fatores de Tempo , Listas de Espera/mortalidade
5.
Catheter Cardiovasc Interv ; 98(7): 1241-1249, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33232583

RESUMO

OBJECTIVES: To assess the efficacy and safety of excimer laser coronary atherectomy (ELCA), as well as, the long-term outcomes and the factors associated with ELCA failure in uncrossable lesions. BACKGROUND: Uncrossable lesions constitute a challenge for percutaneous coronary intervention. METHODS: This multicenter registry included 126 patients with 126 uncrossable lesions. Study endpoints were ELCA success, technical success and a composite of cardiac death, myocardial infarction (MI), and target-lesion revascularization (TLR) on follow-up. Predictors of ELCA failure were analyzed. RESULTS: Moderate or severe calcification was present in 79 (62.7%) of the lesions and 58 (46%) were a chronic total occlusion. ELCA success was obtained in 103 (81.8%) patients. Rotational atherectomy was attempted as bailout in 21 out of 23 ELCA failure (91.3%), being successful in 14 (66.7%) of them. Finally, technical and procedural success were achieved in 114 (90.5%) and 110 (87.3%) of the patients. Severe calcification was independently associated with ELCA failure (OR: 3.73, 95% CI: 1.35-10.32; p = .011). Two (1.6%) patients died (one after a stroke and another patient because of heart failure), 4 (3.2%) developed a non-Q MI without clinical consequences and 1 (0.8%) patient had a Q-MI. Other complications were ventricular tachycardia/fibrillation (n = 2; 1.6%) and flow-limiting dissection (n = 1, 0.8%). At follow-up (median 424 days), 3 (2.4%) patients died (1 (0.8%) from cardiovascular cause) and 15 (11.9%) required TLR. CONCLUSIONS: In our multicenter experience, ELCA use demonstrated to be safe and reasonably effective with a rate of events on follow-up relatively low. Severe calcification was associated with ELCA failure.


Assuntos
Aterectomia Coronária , Aterectomia Coronária/efeitos adversos , Angiografia Coronária , Humanos , Lasers de Excimer/efeitos adversos , Sistema de Registros , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 97(5): 927-937, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33336506

RESUMO

BACKGROUND: During COVID-19 pandemic in Spain, elective procedures were canceled or postponed, mainly due to health care systems overwhelming. OBJECTIVE: The objective of this study was to evaluate the consequences of interrupting invasive procedures in patients with chronic cardiac diseases due to the COVID-19 outbreak in Spain. METHODS: The study population is comprised of 2,158 patients that were pending on elective cardiac invasive procedures in 37 hospitals in Spain on the 14th of March 2020, when a state of alarm and subsequent lockdown was declared in Spain due to the COVID-19 pandemic. These patients were followed-up until April 31th. RESULTS: Out of the 2,158 patients, 36 (1.7%) died. Mortality was significantly higher in patients pending on structural procedures (4.5% vs. 0.8%, respectively; p < .001), in those >80 year-old (5.1% vs. 0.7%, p < .001), and in presence of diabetes (2.7% vs. 0.9%, p = .001), hypertension (2.0% vs. 0.6%, p = .014), hypercholesterolemia (2.0% vs. 0.9%, p = .026) [Correction added on December 23, 2020, after first online publication: as per Dr. Moreno's request changes in p-values were made after original publication in Abstract.], chronic renal failure (6.0% vs. 1.2%, p < .001), NYHA > II (3.8% vs. 1.2%, p = .001), and CCS > II (4.2% vs. 1.4%, p = .013), whereas was it was significantly lower in smokers (0.5% vs. 1.9%, p = .013). Multivariable analysis identified age > 80, diabetes, renal failure and CCS > II as independent predictors for mortality. CONCLUSION: Mortality at 45 days during COVID-19 outbreak in patients with chronic cardiovascular diseases included in a waiting list due to cancellation of invasive elective procedures was 1.7%. Some clinical characteristics may be of help in patient selection for being promptly treated when similar situations happen in the future.


Assuntos
COVID-19/epidemiologia , Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Doenças Cardiovasculares/cirurgia , Procedimentos Cirúrgicos Eletivos/estatística & dados numéricos , Pandemias , SARS-CoV-2 , Listas de Espera , Idoso , Idoso de 80 Anos ou mais , Doenças Cardiovasculares/epidemiologia , Comorbidade , Feminino , Humanos , Masculino , Espanha/epidemiologia
7.
Circulation ; 140(23): 1904-1916, 2019 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-31553204

RESUMO

BACKGROUND: The use of poly-l-lactide acid-based bioresorbable scaffolds is limited in daily clinical practice because of safety concerns and lack of physiological benefit. Magnesium-based bioresorbable scaffold (MgBRS) presents a short resorption period (<1 year) and have the potential of being thromboresistant and exhibiting early restoration of vasomotor function. To date, however, no randomized clinical trial has investigated the performance of MgBRS. Therefore, this study aimed to compare the in-stent/scaffold vasomotion between MgBRS and permanent metallic sirolimus-eluting stent (SES) at 12-month follow-up in ST-segment-elevation myocardial infarction patients. METHODS: This investigator-driven, multicenter, randomized, single-blind, controlled trial randomized ST-segment-elevation myocardial infarction patients 1:1 to SES or MgBRS at 11 academic centers. The primary end point was the rate of increase (≥3%) after nitroglycerin in mean lumen diameter of the in-stent/scaffold segment at 12 months with superiority of MgBRS over SES in the as-treated population. The main secondary end points included angiographic parameters of restenosis, device-oriented composite end point, their individual components, and device thrombosis rate. Besides, endothelial-dependent vasomotor response to acetylcholine (ie, endothelial function) was also assessed in a subgroup of patients (n=69). RESULTS: Between June 2017 and June 2018, 150 ST-segment-elevation myocardial infarction patients were randomized (MgBRS, n=74; SES, n=76). At 1 year, the primary end point was significantly higher in the MgBRS arm (56.5% versus 33.8%; P=0.010). Conversely, late lumen loss was significantly lower in the SES group (in-segment: 0.39±0.49mm versus 0.02±0.27mm, P<0.001; in-device: 0.61±0.55mm versus 0.06±0.21mm; P<0.001). The device-oriented composite end point was higher in the MgBRS arm driven by an increase in ischemia-driven target lesion revascularization rate (12[16.2%] versus 4[5.2%], P=0.030). Definite thrombosis rate was similar between groups (1[1.4%] in the MgBRS arm versus 2[2.6%] in the SES group; P=1.0). Endothelial function assessment at device segment evidenced a more pronounced vasoconstrictive response to maximal dose of acetylcholine in the MgBRS arm (-8.3±3.5% versus -2.4±1.3% in the SES group, P=0.003). CONCLUSIONS: When compared to SES, MgBRS demonstrated a higher capacity of vasomotor response to pharmacological agents (either endothelium-independent or endothelium-dependent) at 1 year. However, MgBRS was associated with a lower angiographic efficacy, a higher rate of target lesion revascularization, without thrombotic safety concerns. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03234348.


Assuntos
Angioplastia Coronária com Balão , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Sirolimo/uso terapêutico , Alicerces Teciduais , Implantes Absorvíveis , Acetilcolina/farmacologia , Idoso , Angiografia Coronária , Reestenose Coronária/epidemiologia , Stents Farmacológicos , Endotélio Vascular/efeitos dos fármacos , Endotélio Vascular/fisiopatologia , Feminino , Humanos , Incidência , Magnésio , Masculino , Pessoa de Meia-Idade , Nitroglicerina/farmacologia , Poliésteres , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/tratamento farmacológico , Tamanho da Amostra , Sirolimo/administração & dosagem , Trombectomia , Vasodilatação/efeitos dos fármacos , Vasodilatadores/uso terapêutico , Sistema Vasomotor/fisiopatologia
8.
Health Qual Life Outcomes ; 18(1): 140, 2020 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-32410687

RESUMO

BACKGROUND: Health-related quality of life (HRQoL) is impaired in patients with stable angina but patients often present with other forms of chest pain. The aim of this study was to compare the pre-diagnostic HRQoL in patients with suspected coronary artery disease (CAD) according to angina type, gender, and presence of obstructive CAD. METHODS: From the pilot study for the European DISCHARGE trial, we analysed data from 24 sites including 1263 patients (45.9% women, 61.1 ± 11.3 years) who were clinically referred for invasive coronary angiography (ICA; 617 patients) or coronary computed tomography angiography (CTA; 646 patients). Prior to the procedures, patients completed HRQoL questionnaires: the Short Form (SF)-12v2, the EuroQoL (EQ-5D-3 L) and the Hospital Anxiety and Depression Scale. RESULTS: Fifty-five percent of ICA and 35% of CTA patients had typical angina, 23 and 33% had atypical angina, 18 and 28% had non-anginal chest discomfort and 5 and 5% had other chest discomfort, respectively. Patients with typical angina had the poorest physical functioning compared to the other angina groups (SF-12 physical component score; 41.2 ± 8.8, 43.3 ± 9.1, 46.2 ± 9.0, 46.4 ± 11.4, respectively, all age and gender-adjusted p < 0.01), and highest anxiety levels (8.3 ± 4.1, 7.5 ± 4.1, 6.5 ± 4.0, 4.7 ± 4.5, respectively, all adjusted p < 0.01). On all other measures, patients with typical or atypical angina had lower HRQoL compared to the two other groups (all adjusted p < 0.05). HRQoL did not differ between patients with and without obstructive CAD while women had worse HRQoL compared with men, irrespective of age and angina type. CONCLUSIONS: Prior to a diagnostic procedure for stable chest pain, HRQoL is associated with chest pain characteristics, but not with obstructive CAD, and is significantly lower in women. TRIAL REGISTRATION: Clinicaltrials.gov, NCT02400229.


Assuntos
Angina Pectoris/fisiopatologia , Doença da Artéria Coronariana/fisiopatologia , Qualidade de Vida , Idoso , Angina Pectoris/classificação , Angina Pectoris/diagnóstico , Doença da Artéria Coronariana/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Distribuição por Sexo , Inquéritos e Questionários
9.
J Cardiovasc Electrophysiol ; 30(3): 448-456, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30556327

RESUMO

BACKGROUND: Radiofrequency ablation (RF) of ventricular tachycardia (VT) due to intramural foci has a high recurrence rate. Several techniques, such as bipolar ablation, irrigated needle ablation catheter, and retrograde coronary venous ethanol ablation have been suggested. Transarterial coronary ethanol ablation (TCEA) can also be effective. We present a case series of TCEA guided with preprocedural imaging to correlated coronary arteries and the intramural substrate. METHODS AND RESULTS: We present three consecutive patients with previous RF of septal VT (100% male; age, 72.6 ± 11.01 years; two patients with hypertrophic cardiomyopathy, one with mechanical aortic valve prosthesis) that underwent TCEA. Cardiac magnetic resonance was performed in two patients and cardiac CT in all patients. Correlation of septal arteries with intramural substrate was analyzed before the procedure so TCEA was attempted according to this analysis. After last TCEA (6.3 ± 2.08 months) the VT burden was reduced in all patients (sum of all implantable cardioverter-defibrillator therapies [antitachycardia pacing and shock] before and after TCEA, 15.8 ± 3.73 vs 0.97 ± 0.63 therapies/month; P = 0.02). No complications occurred during TCEA. CONCLUSIONS: TCEA completely guided with previous magnetic resonance imaging and computed tomography scan to select the coronary artery in relation to the substrate seems to be feasible as an alternative strategy in cases of intramural VT refractory to RF ablation.


Assuntos
Técnicas de Ablação , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Etanol/administração & dosagem , Imagem Cinética por Ressonância Magnética , Tomografia Computadorizada Multidetectores , Taquicardia Ventricular/cirurgia , Septo Interventricular/cirurgia , Idoso , Idoso de 80 Anos ou mais , Humanos , Injeções Intra-Arteriais , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/fisiopatologia
10.
Catheter Cardiovasc Interv ; 92(7): E493-E501, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-29774986

RESUMO

OBJECTIVES: To assess the efficacy and safety of the Xience Prime everolimus-eluting stent (EES) in long coronary lesions in a real-world population. BACKGROUND: Long lesions are considered difficult technically and in terms of achieving successful clinical outcomes. With first generation DES, MACE can be as high as 10% at a short-medium term follow-up. There are a few data available in this subset regarding the use of second generation DES METHODS: A prospective, multicenter registry of consecutive patients (aged 64.8 ± 11.2 years, 77% men and 33% diabetics) in 29 tertiary hospitals with de novo > 24 mm lesions in vessels of 2.25-4 mm was performed. The primary and secondary endpoints were major adverse cardiac events (MACE; cardiac death, myocardial infarction, and target lesion revascularization) and stent thrombosis (ST) at 1, 12, and 24 months. Patients were on dual antiplatelet therapy during 12 months. RESULTS: A total of 610 patients with 705 long lesions were included (1.2 per patient). Lesion length was 34.59 ± 11.17 mm and vessel size 2.93 ± 0.41 mm. Stented length was 39.83 ± 14.08 mm (1.4 stents per lesion). Predilatation/postdiltatation was performed in 75 and 33% of the cases, intravascular ultrasound in 15%. The device success rate was 99.1%. MACE and ST rates at 1, 12, and 24-months follow-up were 0.3, 2.1, and 5.4% and 0.2, 0.7, and 1.5%, respectively. CONCLUSION: In this real-world population, the Xience Prime EES performs extremely well in long lesions, with a very low rate of both MACE and ST.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Europa (Continente) , Everolimo/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 91(3): 435-443, 2018 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-28707379

RESUMO

BACKGROUND: Pre-clinical results of a novel open-cell, thin strut, durable polymer, laser cut cobalt chromium sirolimus-eluting stent (Angiolite) were promising. Using quantitative optical coherence tomographic (OCT) analyses, we explored the healing characteristics of the Angiolite DES system at 3- and 6-months post implantation. METHODS: A total of 103 patients with de novo coronary lesions underwent percutaneous coronary intervention with the Angiolite DES and were randomized 1:3 into two cohorts for angiographic and OCT follow-up, with 28 and 70 patients returning for 3- or 6-month post-PCI surveillance, respectively. The primary endpoints were the 6-month rates of OCT-derived neointimal proliferation, strut coverage and incomplete strut apposition (ISA), whilst the secondary endpoints were 3-month OCT-derived measures of strut coverage and ISA, as well as 6-month quantitative coronary angiographic-derived measures [late lumen loss (LLL), binary restenosis]. RESULTS: The Angiolite stent was successfully implanted in all patients, without periprocedural complications. At 3- and 6-months follow-up, OCT strut coverage was evident in 86.3% and 83.3% of struts, mean neointimal thickness was 73.7 ± 46.5 µm and 73.9 ± 54.3 µm, mean neo-intimal area obstruction of 5.8% ±10.3% and 4.4% ± 11.3%, and ISA rates were 1.3% ± 7.3% and 1.1% ± 6.2%, respectively. In-stent LLL at 6 months was 0.07 ± 0.37 mm, with a binary in-stent angiographic restenosis rate of 0% without any stent thrombosis, myocardial infarction or cardiovascular death, with 1 patient undergoing ischemia-driven target-lesion revascularization. CONCLUSIONS: At 6 months, the Angiolite DES was safe with high rates of strut coverage, modest degrees of neointimal hyperplasia and very low rates of strut malapposition. These data coupled with the absence of in-stent binary restenosis and a very low 6-month in-stent LLL point towards an efficacious DES. Future studies are required to evaluate its efficacy in broader lesion subsets with longer follow-up.


Assuntos
Doença da Artéria Coronariana/cirurgia , Vasos Coronários/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Tomografia de Coerência Óptica , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neointima , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento
12.
Eur Radiol ; 27(7): 2957-2968, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27864607

RESUMO

OBJECTIVES: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate noninvasive test for detection and exclusion of coronary artery disease (CAD). To investigate the comparative effectiveness of CT and ICA, we designed the European pragmatic multicentre DISCHARGE trial funded by the 7th Framework Programme of the European Union (EC-GA 603266). METHODS: In this trial, patients with a low-to-intermediate pretest probability (10-60 %) of suspected CAD and a clinical indication for ICA because of stable chest pain will be randomised in a 1-to-1 ratio to CT or ICA. CT and ICA findings guide subsequent management decisions by the local heart teams according to current evidence and European guidelines. RESULTS: Major adverse cardiovascular events (MACE) defined as cardiovascular death, myocardial infarction and stroke as a composite endpoint will be the primary outcome measure. Secondary and other outcomes include cost-effectiveness, radiation exposure, health-related quality of life (HRQoL), socioeconomic status, lifestyle, adverse events related to CT/ICA, and gender differences. CONCLUSIONS: The DISCHARGE trial will assess the comparative effectiveness of CT and ICA. KEY POINTS: • Coronary artery disease (CAD) is a major cause of morbidity and mortality. • Invasive coronary angiography (ICA) is the reference standard for detection of CAD. • Noninvasive computed tomography angiography excludes CAD with high sensitivity. • CT may effectively reduce the approximately 2 million negative ICAs in Europe. • DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest probability for CAD.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Avaliação de Resultados em Cuidados de Saúde , Tomografia Computadorizada por Raios X/métodos , Idoso , Doença da Artéria Coronariana/economia , Análise Custo-Benefício , Europa (Continente) , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Qualidade de Vida , Estudos Retrospectivos
13.
Circ J ; 80(2): 354-62, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26725763

RESUMO

BACKGROUND: The effects of dual antiplatelet therapy (DAPT) and triple therapy (TT: DAPT plus oral anticoagulation) in patients with atrial fibrillation (AF) undergoing percutaneous coronary intervention (PCI) regarding to CHA2DS2-VASc score remain undefined.We compare the effect of TT vs. DAPT in this setting regarding the CHA2DS2-VASc score. METHODS AND RESULTS: In a prospective multicenter registry, 585 patients (75.2% male, 73.2 ± 8.2 years) with AF undergoing PCI were followed up during 1 year. Of them, 157 (26.8%) had a CHA2DS2-VASc=1, and 428 (73.2%) had a CHA2DS2-VASc ≥2. TT was prescribed in 51.6% with CHA2DS2-VASc=1 and in 55.5% with CHA2DS2-VASc ≥ 2. Patients with CHA2DS2-VASc=1 receiving TT had a similar thromboembolism rate to those on DAPT (1.2% vs. 1.3%, P=0.73), but more total (19.5% vs. 6.9%, P=0.01) and a tendency to more major (4.9% vs. 0%, P=0.06) bleeding. However, patients with CHA2DS2-VASc ≥ 2 receiving TT had a lower thromboembolism rate (1.7% vs. 5.3%, P=0.03) and a trend towards more bleeds (21.8% vs. 15.6%, P=0.06), with an excess of major bleeding (8.4% vs. 3.1%, P=0.01). Rates of major adverse cardiac events (MACE) in both CHA2DS2-VASc subgroups were similar, irrespective of treatment. In a Cox multivariate analysis, TT was associated to major bleeding, but not with MACE. CONCLUSIONS: In patients with AF and CHA2DS2-VASc=1 undergoing PCI, the use of TT involves a high risk of bleeding without a significant benefit in preventing thromboembolism.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/administração & dosagem , Sistema de Registros , Tromboembolia/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/métodos , Hemorragia Pós-Operatória/prevenção & controle , Estudos Prospectivos , Medição de Risco , Tromboembolia/etiologia
14.
Circulation ; 129(11): 1233-43, 2014 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-24370552

RESUMO

BACKGROUND: Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after transcatheter aortic valve implantation on late outcomes in a large cohort of patients. METHODS AND RESULTS: A total of 1556 consecutive patients without prior PPI undergoing transcatheter aortic valve implantation were included. Of them, 239 patients (15.4%) required a PPI within the first 30 days after transcatheter aortic valve implantation. At a mean follow-up of 22±17 months, no association was observed between the need for 30-day PPI and all-cause mortality (hazard ratio, 0.98; 95% confidence interval, 0.74-1.30; P=0.871), cardiovascular mortality (hazard ratio, 0.81; 95% confidence interval, 0.56-1.17; P=0.270), and all-cause mortality or rehospitalization for heart failure (hazard ratio, 1.00; 95% confidence interval, 0.77-1.30; P=0.980). A lower rate of unexpected (sudden or unknown) death was observed in patients with PPI (hazard ratio, 0.31; 95% confidence interval, 0.11-0.85; P=0.023). Patients with new PPI showed a poorer evolution of left ventricular ejection fraction over time (P=0.017), and new PPI was an independent predictor of left ventricular ejection fraction decrease at the 6- to 12-month follow-up (estimated coefficient, -2.26; 95% confidence interval, -4.07 to -0.44; P=0.013; R(2)=0.121). CONCLUSIONS: The need for PPI was a frequent complication of transcatheter aortic valve implantation, but it was not associated with any increase in overall or cardiovascular death or rehospitalization for heart failure after a mean follow-up of ≈2 years. Indeed, 30-day PPI was a protective factor for the occurrence of unexpected (sudden or unknown) death. However, new PPI did have a negative effect on left ventricular function over time.


Assuntos
Valva Aórtica/cirurgia , Cateterismo Cardíaco/tendências , Implante de Prótese de Valva Cardíaca/tendências , Marca-Passo Artificial/tendências , Função Ventricular Esquerda/fisiologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/patologia , Cateterismo Cardíaco/mortalidade , Estudos de Coortes , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
16.
Eur Heart J ; 35(38): 2685-96, 2014 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-24796337

RESUMO

AIM: The aim of this study was to determine the effects of advanced chronic kidney disease (CKD) on early and late outcomes after transcatheter aortic valve implantation (TAVI), and to evaluate the predictive factors of poorer outcomes in such patients. METHODS AND RESULTS: This was a multicentre study including a total of 2075 consecutive patients who had undergone TAVI. Patients were grouped according the estimated glomerular filtration rate as follows: CKD stage 1-2 (≥60 mL/min/1.73 m(2); n = 950), stage 3 (30-59 mL/min/1.73 m(2); n = 924), stage 4 (15-29 mL/min/1.73 m(2); n = 134) and stage 5 (<15 mL/min/1.73 m² or dialysis; n = 67). Clinical outcomes were evaluated at 30-days and at follow-up (median of 15 [6-29] months) and defined according to the VARC criteria. Advanced CKD (stage 4-5) was an independent predictor of 30-day major/life-threatening bleeding (P = 0.001) and mortality (P = 0.027), and late overall, cardiovascular and non-cardiovascular mortality (P < 0.01 for all). Pre-existing atrial fibrillation (HR: 2.29, 95% CI: 1.47-3.58, P = 0.001) and dialysis therapy (HR: 1.86, 95% CI: 1.17-2.97, P = 0.009) were the predictors of mortality in advanced CKD patients, with a mortality rate as high as 71% at 1-year follow-up in those patients with these 2 factors. Advanced CKD patients who had survived at 1-year follow-up exhibited both a significant improvement in NYHA class (P < 0.001) and no deterioration in valve hemodynamics (P = NS for changes in mean gradient and valve area over time). CONCLUSIONS: Advanced CKD was associated with a higher rate of early and late mortality and bleeding events following TAVI, with AF and dialysis therapy determining a higher risk in these patients. The mortality rate of patients with both factors was unacceptably high and this should be taken into account in the clinical decision-making process in this challenging group of patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Insuficiência Renal Crônica/complicações , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Feminino , Hemodinâmica/fisiologia , Humanos , Estimativa de Kaplan-Meier , Tempo de Internação , Masculino , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/mortalidade , Prognóstico , Insuficiência Renal Crônica/mortalidade , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
17.
Circ J ; 78(11): 2657-64, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25241887

RESUMO

BACKGROUND: It is unknown if lack of polymer can provoke a different edge response in drug-eluting stents. The aim of this study was to compare edge vascular response between polymer-free paclitaxel-eluting stent (PF-PES) and polymer-based paclitaxel-eluting stents (PB-PES). METHODS AND RESULTS: A total of 165 eligible patients undergoing percutaneous coronary intervention were prospectively randomized 1:1 to receive either PF-PES or PB-PES. Those patients with paired intravascular ultrasound (IVUS) after procedure and at 9-month follow-up were included in this analysis.Seventy-six patients with 84 lesions, divided into PB-PES (38 patients, 41 lesions) and PF-PES groups (38 patients, 43 lesions) had paired post-procedure and 9-month follow-up IVUS and were therefore included in this substudy. There was a significant lumen decrease at the proximal edge of PF-PES (from 9.02±3.06 mm(2)to 8.47±3.05 mm(2); P=0.040), and a significant plaque increase at the distal edges of PF-PES (from 4.39±2.73 mm(2)to 4.78±2.63 mm(2); P=0.004). At the distal edge there was a significant plaque increase in the PF-PES compared to PB-PES (+8.0% vs. -0.6%, respectively; P=0.015) with subsequent lumen reduction (-5.2% vs. +6.0%, respectively; P=0.024). CONCLUSIONS: PF-PES had significant plaque increase and lumen reduction at the distal edge as compared to PB-PES, probably due to difference in polymer-based drug-release kinetics between the 2 platforms.


Assuntos
Antineoplásicos Fitogênicos , Stents Farmacológicos , Paclitaxel , Intervenção Coronária Percutânea , Polímeros , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ultrassonografia de Intervenção
18.
JAMA Netw Open ; 7(3): e240809, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38446482

RESUMO

Importance: The MOSCA-FRAIL randomized clinical trial compared invasive and conservative treatment strategies in patients with frailty with non-ST-segment elevation myocardial infarction (NSTEMI). It showed no differences in the number of days alive and out of the hospital at 1 year. Objective: To assess the outcomes of the MOSCA-FRAIL trial during extended follow-up. Design, Setting, and Participants: The MOSCA-FRAIL randomized clinical trial was conducted at 13 hospitals in Spain between July 7, 2017, and January 9, 2021, and included 167 adults (aged ≥70 years) with frailty (Clinical Frailty Scale score ≥4) and NSTEMI. In this preplanned secondary analysis, follow-up was extended to January 31, 2023. Data analysis was performed from April 5 to 29, 2023, using the intention-to-treat principle. Interventions: Patients were randomized to a routine invasive (coronary angiography and revascularization if feasible [n = 84]) or a conservative (medical treatment with coronary angiography only if recurrent ischemia [n = 83]) strategy. Main outcomes and measures: The primary end point was the difference in restricted mean survival time (RMST). Secondary end points included readmissions for any cause, considering recurrent readmissions. Results: Among the 167 patients included in the analysis, the mean (SD) age was 86 (5) years; 79 (47.3%) were men and 88 (52.7%) were women. A total of 93 deaths and 367 readmissions accrued. The RMST for all-cause death over the entire follow-up was 3.13 (95% CI, 2.72-3.60) years in the invasive and 3.06 (95% CI, 2.84-3.32) years in the conservative treatment groups. The RMST analysis showed inconclusive differences in survival time (invasive minus conservative difference, 28 [95% CI, -188 to 230] days). Patients under invasive treatment tended to have shorter survival in the first year (-28 [95% CI, -63 to 7] days), which improved after the first year (192 [95% CI, 90-230] days). Kaplan-Meier mortality curves intersected, displaying higher mortality to 1 year in the invasive group that shifted to a late benefit (landmark analysis hazard ratio, 0.58 [95% CI, 0.33-0.99]; P = .045). Early harm was more evident in the subgroup with a Clinical Frailty Scale score greater than 4. No differences were found for the secondary end points. Conclusions and Relevance: In this extended follow-up of a randomized clinical trial of patients with frailty and NSTEMI, an invasive treatment strategy did not improve outcomes at a median follow-up of 1113 (IQR, 443-1441) days. However, a differential distribution of deaths was observed, with early harm followed by later benefit. The phenomenon of depletion of susceptible patients may be responsible for this behavior. Trial registration: ClinicalTrials.gov Identifier: NCT03208153.


Assuntos
Fragilidade , Infarto do Miocárdio sem Supradesnível do Segmento ST , Infarto do Miocárdio com Supradesnível do Segmento ST , Feminino , Humanos , Masculino , Tratamento Conservador , Angiografia Coronária , Análise de Dados , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Idoso , Idoso de 80 Anos ou mais , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
19.
J Nucl Cardiol ; 20(1): 99-110, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23143810

RESUMO

OBJECTIVES: Our study aimed to compare the area at risk (AAR) determined by single-photon emission computed tomography (SPECT) with the Bypass Angioplasty Revascularization Investigation (BARI) and modified Alberta Provincial Project for Outcome Assessment in Coronary Heart Disease (APPROACH) angiographic scores in the setting of patients undergoing coronary angioplasty for either unstable angina or an STEMI. BACKGROUND: Radionuclide myocardial perfusion imaging prior to reperfusion has classically been the most widely practised technique for assessing the AAR and has been successfully used to compare the efficacy of various reperfusion strategies in patients with an ST-segment elevation myocardial infarction (STEMI). The BARI and modified APPROACH scores are angiographic methods widely used to provide a rapid estimation of the AAR; however, they have not been directly validated with myocardial perfusion single-photon emission computed tomography (SPECT). METHODS: Fifty-five patients with no previous myocardial infarction who underwent coronary angioplasty for single-vessel disease (unstable angina: n = 25 or an STEMI: n = 30) with no evidence of collaterals (Rentrop Collateral Score <2) were included in a prospective study. In STEMI patients, the (99m)Tc-tetrofosmin was injected prior to opening of the occluded vessel and, in patients with unstable angina after 10-15 seconds of balloon inflation. Acquisition was performed with a dual-head gammacamera with a low-energy and high-resolution collimator. A total of 60 projections were acquired using a non-circular orbit. No attenuation or scatter correction was used. Maximal contours of hypoperfusion regions corresponding to each coronary artery occlusion were delineated over a polar map of 17 segments and compared with the estimated AAR determined by two experienced interventional cardiologists using both angiographic scores. RESULTS: Mean AAR percentage in SPECT was 35.0 (10.0%-56.0%). A high correlation was found between BARI and APPROACH scores (r = 0.9, P < .001). Furthermore, a high correlation was also observed between BARI versus SPECT and APPROACH versus SPECT to estimate the AAR (r = 0.9, P < .001 and r = 0.8, P < .001, respectively). Better correlations were observed when the left anterior descending artery (LAD) was revascularized (r = 0.8, P < 0.001 with BARI; r = 0.8, P = .001 with APPROACH) compared to other territories (r = 0.8, P = .001 with BARI; r = 0.7, P = .001 with APPROACH). Also, better correlations were observed in patients who underwent an elective rather than a primary percutaneous revascularization procedure. CONCLUSIONS: In the absence of collateral flow, BARI and APPROACH scores constitute valid methods for AAR estimation in current clinical practice, with more accurate results when used for the LAD territory; both are useful not only in STEMI patients but also in patients with unstable angina.


Assuntos
Coração/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Miocárdio/patologia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Angioplastia Coronária com Balão , Angiografia Coronária/métodos , Circulação Coronária , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Perfusão , Reprodutibilidade dos Testes , Risco
20.
Can J Cardiol ; 2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38013065

RESUMO

BACKGROUND: Percutaneous mitral paravalvular leak (PVL) closure techniques are an effective and safe alternative to surgical treatment, but data regarding long-term outcomes are scarce. We aim to describe the impact of successful percutaneous mitral PVL closure on long-term outcomes. METHODS: All consecutive patients in whom a first-attempt percutaneous mitral PVL closure was performed in a single tertiary centre between January 2010 and October 2021 were included. Clinical variables, procedural details, and procedural success were collected. Patients were classified based on procedural success, defined as no more than mild residual leak. All-cause mortality was the primary endpoint. Cardiovascular death and heart failure hospitalizations (HFHs) were key secondary endpoints. RESULTS: Ninety patients (median age 72.5 years [66.0-78.4]; median EuroSCORE-II 8.2 [5.3-12.46]) were included. Although reduction of at least 1 degree in PVL severity was achieved in 82 (91.1%), procedural success was achieved in 47 (52.2%). Chronic kidney disease, previous surgery for PVL, and the presence of multiple jets were independently associated with procedural failure. After a median follow-up of 3.2 (1.2-5.2) years, mortality rate was higher in the procedural failure group (27.3 per 100 patients-years) compared with the group with successful closure (8.2 per 100 patient-years). Procedural failure was associated with all-cause death (adjusted hazard ratio [aHR], 2.59; 95% confidence interval [CI], 1.41-4.78), cardiovascular death (aHR, 3.53; 95% CI, 1.67-7.49) and HFH (aHR, 3.27; 95% CI,1.72-6.20). CONCLUSIONS: A successful reduction in PVL to mild or absent is associated with improved rates of all-cause death, cardiovascular death, and HFHs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA