Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Am Coll Cardiol ; 46(2): 246-52, 2005 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-16022950

RESUMO

OBJECTIVES: We sought to compare, in a prospective randomized multicenter study, the effect of adjunctive thrombectomy using X-Sizer (eV3, White Bear Lake, Minnesota) before percutaneous coronary intervention (PCI) versus conventional PCI in patients with acute myocardial infarction (AMI) for <12 h and Thrombolysis In Myocardial Infarction (TIMI) flow grade 0 to 1. The primary end point was the magnitude of ST-segment resolution after PCI. BACKGROUND: Despite a high rate of TIMI flow grade 3 achieved by PCI in patients with AMI, myocardial reperfusion remains relatively low. Distal embolization of thrombotic materials may play a major role in this setting. METHODS: We conducted a prospective, randomized, multicenter study in patients with AMI <12 h and initial TIMI flow grade 0 to 1 who were treated with primary PCI. The magnitude of ST-segment resolution 1 h after PCI was the primary end point. RESULTS: A total of 201 patients were included. Treatment groups were comparable by age (61 +/- 13 years), diabetes (22%), previous MI (8%), anterior MI (52%), onset-to-angiogram (258 +/- 173 min), and glycoprotein IIb/IIIa inhibitor use (59%). The magnitude of ST-segment resolution was greater in the X-Sizer group compared with the conventional group (7.5 vs. 4.9 mm, respectively; p = 0.033) as ST-segment resolution >50% (68% vs. 53%; p = 0.037). The occurrence of distal embolization was reduced (2% vs. 10%; p = 0.033) and TIMI flow grade 3 was obtained in 96% vs. 89%, respectively (p = 0.105). Myocardial blush grade 3 was similar (30% vs. 31%; p = NS). Six-month clinical outcome was comparable (death, 6% vs. 4% and major adverse cardiac and cerebral events, 13% vs. 13%, respectively). By multivariate analysis, independent predictors of ST-segment resolution >50% were: younger age, non-anterior MI, use of the X-Sizer, and a short time interval from symptom onset. CONCLUSIONS: Reducing thrombus burden with X-Sizer before stenting leads to better myocardial reperfusion, as illustrated by a reduced risk of distal embolization and better ST-segment resolution.


Assuntos
Infarto do Miocárdio/cirurgia , Trombectomia/instrumentação , Angioplastia Coronária com Balão , Cateterismo Cardíaco/instrumentação , Angiografia Coronária , Circulação Coronária , Eletrocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Reperfusão Miocárdica , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Estudos Prospectivos , Stents , Fatores de Tempo
2.
J Invasive Cardiol ; 17(4): 199-202, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15831972

RESUMO

BACKGROUND: Various stent coatings have been shown to significantly reduce restenosis rates in comparison to non-coated devices. Therefore, the short- and mid-term performance of the new polyphosphazene-coated Coroflex Theca-Stent was investigated. METHODS: 103 patients [63.9 +/- 11 yrs, 5/103 (4.9%) lesion type A, 52/103 (50.5%) type B1, and 46 of 103 (44.6%) type B2] were enrolled for elective single stent deployment into de-novo coronary lesions (stenoses: greater than or equal to 70%, < 100%; reference diameter greater than or equal to 2.75 mm, less than or equal to 4 mm; lesion length: < 16 mm). RESULTS: Deployment and procedural success were 100%, in 57/103 (55.3%) patients without pre-dilatation. 3/103 (2.9%) patients were lost to follow-up. During the 7.1 +/- 2.3 months clinical follow-up, 3 of 100 (3.0%) patients underwent premature target lesion revascularizations, 4 /100 (4%) had non-target lesion-related deaths, and 1 of 100 (1%) suffered myocardial infarction. Among the 77 of 100 (77.0%) patients who underwent angiographic follow-up, the initial stenosis declined from 87.3 +/- 5.7% to 14.2 +/- 8.3% after stenting, and increased to 32.8 +/- 22.7% after 6.4 +/- 1.3 months. The late loss and late loss index were 0.6 +/- 0.7 mm and 0.2 +/- 0.4, respectively; the recurrence rate was 12 of 77 (15.6%), with reintervention required in 11 of 77 (14.3%) of these patients. CONCLUSION: The Coroflex Theca-Stent provides excellent procedural results and a low restenosis rate. Further development of this polymer as the final coating and as the basis for drug-eluting stents seems justified.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Reestenose Coronária/prevenção & controle , Isquemia Miocárdica/terapia , Stents/normas , Materiais Revestidos Biocompatíveis , Reestenose Coronária/epidemiologia , Vasos Coronários/patologia , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Organofosforados , Polímeros , Estudos Prospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA