Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Virol J ; 19(1): 54, 2022 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-35346227

RESUMO

INTRODUCTION: RT-PCR testing on nasopharyngeal swabs is a key component in the COVID-19 fighting, provided to use sensitive and specific SARS-CoV2 genome targets. In this study, we aimed to evaluate and to compare 4 widely used WHO approved RT-PCR protocols on real clinical specimens, to decrypt the reasons of the diverging results and to propose recommendations for the choice of the genome targets. METHODS: 260 nasopharyngeal samples were randomly selected among the samples tested between Week-16, 2020 and week-16 2021, in the Institut Pasteur de Tunis, Tunisia, one of the referent laboratories of COVID-19 in Tunisia. All samples were tested by Charité, Berlin protocol (singleplex envelop (E) and singleplex RNA-dependent RNA polymerase (RdRp)), Hong Kong Universiy, China protocol (singleplex nucleoprotein (N) and singleplex Open reading frame Orf1b), commercial test DAAN Gene® (using the CDC China protocol), (triplex N, Orf1ab with internal control) and Institut Pasteur Paris protocol (IPP) (triplex IP2(nsp9) and IP4 (nsp12) with internal control). For IPP, a selection from samples positive by IP2 but negative with IP4 was re-tested by exactly the same protocol but this time in singleplex. New results were described and analyzed. RESULTS: In vitro analysis showed discordant results in 29.2% of cases (76 out of 260). The most discordant protocol is DAAN Gene® due to the false positive late signals with N target. Discordant results between the two protocol's targets are more frequent when viral load are low (high Ct values). Our results demonstrated that the multiplexing has worsened the sensitivity of the IP4 target. CONCLUSION: We provide concise recommendations for the choice of the genome targets, the interpretation of the results and the alarm signals which makes suspect a gene mutation.


Assuntos
COVID-19 , RNA Viral , COVID-19/diagnóstico , Humanos , Laboratórios , RNA Viral/análise , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa , SARS-CoV-2/genética , Sensibilidade e Especificidade , Organização Mundial da Saúde
2.
Arch Microbiol ; 204(5): 238, 2022 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-35366683

RESUMO

INTRODUCTION: Routine laboratory screening is based on the detection of WNV specific IgM and IgG in blood and cerebrospinal fluid. Confirmation is then classically applied by real time RT-PCR (rRT-PCR) in Cerebrospinal fluid (CSF), which often gives negative results due to too short virorachia and late sampling. rRT-PCR was applied-for the first time for routine diagnosis purpose-on urine samples. METHODS: During 2018 outbreak in Tunisia, 107 patients presented WNV neurologic symptoms and were positive for WNV serology. Of them, 95 patients were sampled for urine and 35 were sampled for CSF. Qualitative rRT-PCR was performed on both type of samples. RESULTS: WNV RNA was detected in 50.5% of urine samples (48/95) and in 2.8% of CSF samples (1/35). WNV RNA was detectable from day 1 to day 41 from symptom onset, however, positive urine rate was 53.1% during the first 10 days from symptom onset. The proportions of urine-positive and urine-negative samples, based on day of collection, showed no statistical difference (p > 0.005). Cycle threshold (Ct) values ranged from 12 to 39, with no correlation with the day of collection. The lowest Ct value was detected for urine sampled on day 5 after symptom onset. A statistically significant difference was found between age groups of confirmed and non confirmed cases (p < 0.001). DISCUSSION/CONCLUSION: Our study reported the use of rRT-PCR on urine samples as a confirmatory diagnostic tool for WNV "probable cases" during an outbreak. Our findings underlined the reliability and the rapidity of this confirmatory tool, even late, and showed its superiority on CSF investigation.


Assuntos
Febre do Nilo Ocidental , Vírus do Nilo Ocidental , Humanos , RNA Viral/genética , Reprodutibilidade dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Febre do Nilo Ocidental/diagnóstico , Febre do Nilo Ocidental/epidemiologia , Vírus do Nilo Ocidental/genética
3.
J Clin Virol ; 170: 105633, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38103483

RESUMO

West Nile Virus (WNV) causes a serious public health concern in many countries around the world. Virus detection in pathological samples is a key component of WNV infection diagnostic, classically performed by real-time PCR. In outbreak situation, rapid detection of the virus, in peripheral laboratories or at point of care, is crucial to guide decision makers and for the establishment of adequate action plans to prevent virus dissemination. Here, we evaluate a Loop-mediated isothermal amplification (LAMP) tool for WNV detection. Amplifications were performed comparatively on extracted viral RNA and on crude samples using a classical thermal cycler and a portable device (pebble device). qRT-PCR was used as gold standard and two sets of urine samples (n = 62 and n = 74) were used to evaluate the retained amplification protocols and assess their sensitivity and specificity. RT-LAMP on RNA extracts and crude samples showed a sensitivity of 90 % and 87 %, respectively. The specificity was 100 % for extracts and 97 % for crude samples. Using the device, the RT-LAMP on extracted RNA was comparable to the gold standard results (100 % sensitivity and specificity) and it was a bit lower on crude samples (65 % sensitivity and 94 % specificity). These results show that RT-LAMP is an efficient technique to detect WNV. RT-LAMP provides a rapid, sensitive, high-throughput and portable tool for accurate WNV detection and has potentials to facilitate diagnostic and surveillance efforts both in the laboratory and in the field, especially in developing countries.


Assuntos
Vírus do Nilo Ocidental , Humanos , Vírus do Nilo Ocidental/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Diagnóstico Molecular , Sensibilidade e Especificidade , RNA Viral/genética
4.
Vaccines (Basel) ; 12(2)2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38400157

RESUMO

BACKGROUND: Allogeneic hematopoietic stem cell transplantation (ASCT) induces acquired immunodeficiency, potentially altering vaccine response. Herein, we aimed to explore the clinical tolerance and the humoral and cellular immune responses following anti-SARS-CoV-2 vaccination in ASCT recipients. METHODS: A prospective, non-randomized, controlled study that involved 43 ASCT subjects and 31 healthy controls. Humoral response was investigated using the Elecsys® test anti-SARS-CoV-2. Cellular response was assessed using the QFN® SARS-CoV-2 test. The lymphocyte cytokine profile was tested using the LEGENDplex™ HU Th Cytokine Panel Kit (12-plex). RESULTS: Adverse effects (AE) were observed in 69% of patients, encompassing pain at the injection site, fever, asthenia, or headaches. Controls presented more side effects like pain in the injection site and asthenia with no difference in the overall AE frequency. Both groups exhibited robust humoral and cellular responses. Only the vaccine transplant delay impacted the humoral response alongside a previous SARS-CoV-2 infection. Noteworthily, controls displayed a Th1 cytokine profile, while patients showed a mixed Th1/Th2 profile. CONCLUSIONS: Pfizer-BioNTech® anti-SARS-CoV-2 vaccination is well tolerated in ASCT patients, inducing robust humoral and cellular responses. Further exploration is warranted to understand the impact of a mixed cytokine profile in ASCT patients.

5.
Virus Res ; 344: 199353, 2024 06.
Artigo em Inglês | MEDLINE | ID: mdl-38490581

RESUMO

The emergence of SARS-CoV-2 variants has led to several cases among children. However, limited information is available from North African countries. This study describes the SARS-CoV-2 strains circulating in Tunisian pediatric population during successive waves. A total of 447 complete sequences were obtained from individuals aged from 13 days to 18 years, between March 2020 and September 2022: 369 sequences generated during this study and 78 ones, available in GISAID, previously obtained from Tunisian pediatric patients. These sequences were compared with 354 and 274 ones obtained from Tunisian adults and a global dataset, respectively. The variant circulation dynamics of predominant variants were investigated during the study period using maximum-likelihood phylogenetic analysis. Among the studied population, adolescents were the predominant age group, comprising 55.26% of cases. Twenty-three lineages were identified; seven of which were not previously reported in Tunisia. Phylogenetic analysis showed a close relationship between the sequences from Tunisian adults and children. The connections of sequences from other countries were variable according to variants: close relationships were observed for Alpha, B1.160 and Omicron variants, while independent Tunisian clusters were observed for Delta and B.1.177 lineages. These findings highlight the pivotal role of children in virus transmission and underscore the impact of vaccination on virus spread. Vaccination of children, with booster doses, may be considered for better management of future emergences.


Assuntos
COVID-19 , Filogenia , SARS-CoV-2 , Humanos , Tunísia/epidemiologia , COVID-19/virologia , COVID-19/epidemiologia , Criança , SARS-CoV-2/genética , SARS-CoV-2/classificação , SARS-CoV-2/isolamento & purificação , Pré-Escolar , Lactente , Adolescente , Masculino , Recém-Nascido , Feminino
6.
Front Med (Lausanne) ; 10: 1226207, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38020093

RESUMO

Background: The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is responsible for serious respiratory infections in humans. Even in the absence of respiratory symptoms, gastrointestinal (GI) signs were commonly reported in adults and children. Thus, oral-fecal transmission was suspected as a possible route of infection. The objective of this study was to describe RNA shedding in nasopharyngeal and stool samples obtained from asymptomatic and symptomatic children and to investigate virus viability. Methods: This study included 179 stool and 191 nasopharyngeal samples obtained from 71 children, which included symptomatic (n = 64) and asymptomatic (n = 7) ones. They were collected every 7 days from the onset of the infection until negativation. Viral RNA was detected by real-time RT-PCR, targeting the N and ORF1 genes. Whole-genome sequencing was performed for positive cases. Viral isolation was assessed on Vero cells, followed by molecular detection confirmation. Results: All cases included in this study (n = 71) were positive in their nasopharyngeal samples. SARS-CoV-2 RNA was detected in 36 stool samples obtained from 15 out of 71 (21.1%) children; 13 were symptomatic and two were asymptomatic. Excretion periods varied from 7 to 21 days and 7 to 14 days in nasopharyngeal and fecal samples, respectively. Four variants were detected: Alpha (n = 3), B.1.160 (n = 3), Delta (n = 7), and Omicron (n = 1). Inoculation of stool samples on cell culture showed no specific cytopathic effect. All cell culture supernatants were negative for RT-qPCR. Conclusion: Our study demonstrated nasopharyngeal and fecal shedding of SARS-CoV-2 RNA by children up to 21 and 14 days, respectively. Fecal shedding was recorded in symptomatic and asymptomatic children. Nevertheless, SARS-CoV-2 was not isolated from positive stool samples.

7.
Vaccines (Basel) ; 11(8)2023 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-37631897

RESUMO

(1) Background: This study aimed to compare the immunogenicity of the mix-and-match CoronaVac/BNT162b2 vaccination to the homologous CoronaVac/CoronaVac regimen. (2) Methods: We conducted a simple-blinded randomized superiority trial to measure SARS-CoV-2 neutralization antibodies and anti-spike receptor binding domain (RBD) IgG concentrations in blood samples of participants who had received the first dose of CoronaVac vaccine followed by a dose of BNT162b2 or CoronaVac vaccine. The primary endpoint for immunogenicity was the serum-neutralizing antibody level with a percentage of inhibition at 90% at 21-35 days after the boost. A difference of 25% between groups was considered clinically relevant. (3) Results: Among the 240 eligible participants, the primary endpoint data were available for 100 participants randomly allocated to the mix-and-match group versus 99 participants randomly allocated to the homologous dose group. The mix-and-match regimen elicited significantly higher levels of neutralizing antibodies (median level of 96%, interquartile range (IQR) (95-97) versus median level of 94%, IQR (81-96) and anti-spike IgG antibodies (median level of 13,460, IQR (2557-29,930) versus median level of 1190, IQR (347-4964) compared to the homologous group. Accordingly, the percentage of subjects with a percentage of neutralizing antibodies > 90% was significantly higher in the mix-and-match group (90.0%) versus the homologous (60.6%). Interestingly, no severe events were reported within 30 days after the second dose of vaccination in both groups. (4) Conclusions: Our data showed the superiority of the mix-and-match CoronaVac/BNT162b2 vaccination compared to the CoronaVac/CoronaVac regimen in terms of immunogenicity, thus constituting a proof-of-concept study supporting the use of inactivated vaccines in a mix-and-match strategy while ensuring good immunogenicity and safety.

8.
Diagn Microbiol Infect Dis ; 105(4): 115903, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36805620

RESUMO

Management of the COVID-19 pandemic relies on molecular diagnostic methods supported by serological tools. Herein, we developed S-RBD- and N- based ELISA assays useful for infection rate surveillance as well as the follow-up of acquired protective immunity against SARS-CoV-2. ELISA assays were optimized using COVID-19 Tunisian patients' sera and prepandemic controls. Assays were further validated in 3 African countries with variable endemic settings. The receiver operating curve was used to evaluate the assay performances. The N- and S-RBD-based ELISA assays performances, in Tunisia, were very high (AUC: 0.966 and 0.98, respectively, p < 0.0001). Cross-validation analysis showed similar performances in different settings. Cross-reactivity, with malaria infection, against viral antigens, was noticed. In head-to-head comparisons with different commercial assays, the developed assays showed high agreement. This study demonstrates, the added value of the developed serological assays in low-income countries, particularly in ethnically diverse populations with variable exposure to local endemic infectious diseases.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Pandemias , Ensaio de Imunoadsorção Enzimática , Tunísia/epidemiologia , Anticorpos Antivirais
9.
Sci Rep ; 12(1): 11298, 2022 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-35788676

RESUMO

Reliable serological assays are needed to understand the real impact of COVID-19. In order to compare the efficiency of different COVID-19 vaccines used in the National Vaccination Program in Tunisia, we have developed a quantitative in-house ELISA. The ELISA is based on the ectodomain of the SARS-CoV-2 Spike Baculovirus recombinant protein. We used a panel of 145 COVID-19 RT-PCR positive serum samples and 116 pre-pandemic serum samples as a negative panel. The validation was carried out by comparison to four commercial techniques (Vidas SARS-CoV-2 IgG anti-RBD Biomérieux, Elecsys Anti-Nucleocapsid of SARS-CoV-2 Roche, cPass GenScript and the quantitative Elecsys Anti-RBD of SARS-CoV-2, Roche). For the evaluation of the National Vaccination campaign, we have included 115 recipients who received one of the approved vaccines. The qualitative performances of the developed ELISA gave 96% sensitivity, 97.5% specificity and 0.968 accuracy. For the evaluation of the different brand of vaccines in recipients not previously infected with SARS-CoV-2, it seems that mRNA vaccine of Pfizer/BioNTech has shown a higher efficacy compared to inactivated virus vaccines. COVID-19 convalescent individuals have generated poor antibody responses. Nevertheless, when they are vaccinated with any brand of the COVID-19 vaccines, many of them mounted an exponential increase of the induced immune responses, qualified as a "hybrid vigor immunity". Our developed in-house ELISA seems to be very efficient in evaluating the effectiveness of anti-COVID-19 vaccination. Platforms based on mRNA vaccine are better performing than those based on inactivated virus.


Assuntos
COVID-19 , Vacinas Virais , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Ensaio de Imunoadsorção Enzimática , Humanos , SARS-CoV-2 , Vacinas de Produtos Inativados , Vacinas Sintéticas , Vacinas de mRNA
10.
Biomedicines ; 10(12)2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36551862

RESUMO

Introduction: SARS-CoV-2 serology have several indications. Currently, as there are various types available, it is important to master their performance in order to choose the best test for the indication. We evaluated and compared four different commercial serology tests, three of them had the Food and Drug Administration Emergency Use Authorization (FDA-EUA). Our goal was to provide new data to help guide the interpretation and the choice of the serological tests. Methods: Four commercial tests were studied: Elecsys® Roche® on Cobas® (total anti-nucleocapsid (N) antibodies), VIDAS® Biomerieux® (IgM and IgG anti- receptor binding domain (RBD) antibodies), Mindray® (IgM and IgG anti-N and anti-RBD antibodies) and Access® Beckman Coulter® (IgG anti-RBD antibodies). Two panels were tested: a positive panel (n = 72 sera) obtained from COVID-19-confirmed patients with no vaccination history and a negative panel (n = 119) of pre-pandemic sera. The analytical performances were evaluated and the ROC curve was drawn to assess the manufacturer's cut-off for each test. Results: A large range of variability between the tests was found. The Mindray®IgG and Cobas® tests showed the best overall sensitivity, which was equal to 79.2% CI 95% (67.9−87.8). The Cobas® test showed the best sensitivity after 14 days of COVID-19 molecular confirmation; which was equal to 85.4% CI 95% (72.2−93.9). The Access® test had a lower sensitivity, even after day 14 (55.5% CI 95% (43.4−67.3)). The best specificity was noted for the Cobas®, VIDAS®IgG and Access® IgG tests (100% CI 95% (96.9−100)). The IgM tests, VIDAS®IgM and Mindray®IgM, showed the lowest specificity and sensitivity rates. Overall, only 43 out of 72 sera (59.7%) showed concordant results by all tests. Retained cut-offs for a significantly better sensitivity and accuracy, without significant change in the specificity, were: 0.87 for Vidas®IgM (p = 0.01) and 0.14 for Access® (p < 10−4). The combination of Cobas® with Vidas® IgM and IgG offered the best accuracy in comparison with all other tests combinations. Conclusion: Although using an FDA-EUA approved serology test, each laboratory should carry out its own evaluation. Tests variability may raise some concerns that seroprevalence studies may vary significantly based on the used serology test.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA