RESUMO
Intact-mass spectrometry has huge potential for clinical application, as it enables both quantitative and qualitative analysis of intact proteins and possibly unlocks additional pathophysiological information via, e.g., detection of specific post-translational modifications (PTMs). Such valuable and clinically useful selectivity is typically lost during conventional bottom-up mass spectrometry. We demonstrate an innovative immunoprecipitation protein enrichment assay coupled to ultrahigh performance liquid chromatography quadrupole time-of-flight high resolution mass spectrometry (UPLC-QToF-HRMS) for the fast and simple identification of the protein tumor marker Neuron Specific Enolase Gamma (NSEγ) at low endogenous concentrations in human serum. Additionally, using the combination of immunoaffinity purification with intact mass spectrometry, the presence of NSEγ in an acetylated form in human serum was detected. This highlights the unique potential of immunoaffinity intact mass spectrometry in clinical diagnostics.
Assuntos
Biomarcadores Tumorais , Espectrometria de Massas , Fosfopiruvato Hidratase , Fosfopiruvato Hidratase/sangue , Fosfopiruvato Hidratase/isolamento & purificação , Humanos , Biomarcadores Tumorais/sangue , Biomarcadores Tumorais/metabolismo , Acetilação , Espectrometria de Massas/métodos , Processamento de Proteína Pós-Traducional , Imunoprecipitação/métodos , Cromatografia Líquida de Alta Pressão/métodosRESUMO
OBJECTIVES: Numerous studies have proven the potential of cytokeratin 19 fragment 21-1 (CYFRA 21-1) detection in the (early) diagnosis and treatment monitoring of non-small cell lung cancer (NSCLC). Conventional immunoassays for CYFRA 21-1 quantification are however prone to interferences and lack diagnostic sensitivity and standardization. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is an emerging approach based on a different, often superior, detection principle, which may improve the clinical applicability of CYFRA 21-1 in cancer diagnostics. Therefore, we developed and validated a protein precipitation, immunoaffinity (IA) LC-MS/MS assay for quantitative analysis of serum CYFRA 21-1. METHODS: Selective sample preparation was performed using ammonium sulfate (AS) precipitation, IA purification, tryptic digestion and LC-MS/MS quantification using a signature peptide and isotopically labeled internal standard. The workflow was optimized and validated according to EMA guidelines and results were compared to a conventional immunoassay. RESULTS: Significant interference effects were seen during IA purification, which were sufficiently solved by performing AS precipitation prior to IA purification. A linear calibration curve was obtained in the range of 1.0-100â¯ng/mL (R2=0.98). Accuracy and precision were well within acceptance criteria. In sera of patients suspected of lung cancer, the method showed good correlation with the immunoassay. CONCLUSIONS: A robust AS precipitation-IA LC-MS/MS assay for the quantification of serum CYFRA 21-1 was developed. With this assay, the clinically added value of LC-MS/MS-based detection over immunoassays can be further explored.
Assuntos
Antígenos de Neoplasias , Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Cromatografia Líquida/métodos , Queratina-19 , Espectrometria de Massas em Tandem/métodos , Neoplasias Pulmonares/diagnóstico , Biomarcadores Tumorais , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Espectrometria de Massa com Cromatografia LíquidaRESUMO
Fluorouracil is among the most used antimetabolite drugs for the chemotherapeutic treatment of various types of gastrointestinal malignancies. Dihydropyrimidine dehydrogenase (DPYD) genotyping prior to fluorouracil treatment is considered standard practice in most European countries. Yet, current pre-therapeutic DPYD genotyping procedures do not identify all dihydropyrimidine dehydrogenase (DPD)-deficient patients. Alternatively, DPD activity can be estimated by determining the DPD phenotype by quantification of plasma concentrations of the endogenous uracil and thymine concentrations and their respective metabolites dihydrouracil (DHU) and dihydrothymine (DHT). Liquid chromatography - mass spectrometry (LC-MS) detection is currently considered as the most adequate method for quantification of low-molecular weight molecules, although the sample preparation method is highly critical for analytical outcome. It was hypothesized that during protein precipitation, the recovery of the molecule of interest highly depends on the choice of precipitation agent and the extent of protein binding in plasma. In this work, the effect of protein precipitation using acetonitrile (ACN) compared to strong acid perchloric acid (PCA) on the recovery of uracil, thymine, DHU and DHT is demonstrated. Upon the analysis of plasma samples, PCA precipitation showed higher concentrations of uracil and thymine as compared to ACN precipitation. Using ultrafiltration, it was shown that uracil and thymine are significantly (60-65â¯%) bound to proteins compared to DHU and DHT. This shows that before harmonized cut-off levels of DPD phenotyping can be applied in clinical practice, the analytical methodology requires extensive further optimization.
Assuntos
Di-Hidrouracila Desidrogenase (NADP) , Fenótipo , Ligação Proteica , Timina , Uracila , Timina/metabolismo , Uracila/análogos & derivados , Uracila/metabolismo , Uracila/sangue , Di-Hidrouracila Desidrogenase (NADP)/metabolismo , Di-Hidrouracila Desidrogenase (NADP)/genética , Humanos , Cromatografia Líquida/métodos , Fluoruracila/metabolismo , Fluoruracila/sangue , Genótipo , Deficiência da Di-Hidropirimidina Desidrogenase/metabolismo , Espectrometria de Massas em Tandem/métodosRESUMO
OBJECTIVES: Timely diagnosis of lung cancer (LC) is crucial to achieve optimal patient care and outcome. Moreover, the number of procedures required to obtain a definitive diagnosis can have a large influence on the life expectancy of a patient. Here, adherence with existing Dutch guidelines for timeliness and type and number of invasive and imaging procedures was assessed. MATERIALS AND METHODS: 1096 patients with suspected LC were enrolled in this multicenter prospective study (NL9146). The overall survival, time from referral to the first appointment with the pulmonologist, time to diagnosis and treatment, and the number of imaging and invasive procedures were evaluated. Patients were divided into different diagnostic groupsearly- and advanced stage non-small-cell lung cancer (NSCLC), small-cell lung cancer (SCLC), large cell neuroendocrine carcinoma of the lung (LCNEC), patients without LC and patients without a definitive diagnosis. RESULTS: The majority of patients (66 %) received a definitive diagnosis within 5 weeks, although the time to diagnosis of early-stage LC patients and patients without LC was significantly longer comparted to advanced stage LC. An increase in invasive procedures was seen for early-stage LC compared to advanced stage LC and for 13 % of the advanced stage non-squamous NSCLC patients up to three additional invasive procedures were performed solely to obtain sufficient material for NGS. For patients without a definitive diagnosis, 50 % did undergo at least one invasive procedure, while 11 % did not wish to undergo any invasive procedures. CONCLUSION: These insights could aid in improved LC diagnostics and efficient implementation of new techniques like liquid biopsy and artificial intelligence. This may lead to more timely LC care, a decreased number of invasive procedures, less variability between the diagnostic trajectory of different patients and aid in obtaining a definitive diagnosis for all patients.
Assuntos
Carcinoma Neuroendócrino , Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/terapia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/terapia , Inteligência Artificial , Estudos Prospectivos , Hospitais , PulmãoRESUMO
Identification of actionable mutations in advanced stage non-squamous non-small-cell lung cancer (NSCLC) patients is recommended by guidelines as it enables treatment with targeted therapies. In current practice, mutations are identified by next-generation sequencing of tumor DNA (tDNA-NGS), which requires tissue biopsies of sufficient quality. Alternatively, circulating tumor DNA (ctDNA) could be used for mutation analysis. This prospective, multicenter study establishes the diagnostic value of ctDNA analysis by droplet digital PCR (ctDNA-ddPCR) in patients with primary lung cancer. CtDNA from 458 primary lung cancer patients was analyzed using a panel of multiplex ddPCRs for EGFR (Ex19Del, G719S, L858R, L861Q and S768I), KRAS G12/G13 and BRAF V600 mutations. For 142 of 175 advanced stage non-squamous NSCLC patients tDNA-NGS results were available to compare to ctDNA-ddPCR. tDNA-NGS identified 98 mutations, of which ctDNA-ddPCR found 53 mutations (54%), including 32 of 45 (71%) targetable driver mutations. In 2 of these 142 patients, a mutation was found by ctDNA-ddPCR only. In 33 advanced stage patients lacking tDNA-NGS results, ctDNA-ddPCR detected 15 additional mutations, of which 7 targetable. Overall, ctDNA-ddPCR detected 70 mutations and tDNA-NGS 98 mutations in 175 advanced NSCLC patients. Using an up-front ctDNA-ddPCR strategy, followed by tDNA-NGS only if ctDNA-ddPCR analysis is negative, increases the number of mutations found from 98 to 115 (17%). At the same time, up-front ctDNA-ddPCR reduces tDNA-NGS analyses by 40%, decreasing the need to perform (additional) biopsies.
RESUMO
Neuron-specific enolase (NSE) is a promising small-cell lung cancer (SCLC) biomarker composed of αγ and γγ isozyme dimers. As the conventional immunoassays are prone to interferences and cannot differentiate between the isozymes, we developed a multiplex immunoaffinity (IA) liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the quantification of NSEα and NSEγ in human serum. A calibrator was prepared by performing cold denaturation of recombinantly expressed αα and γγ enolase dimers to induce a new dimer equilibrium that was determined to be approximately 1αγ:1γγ:1αα. Selective sample purification was achieved by performing IA extraction using an antibody specific towards NSEγ. The isolated αγ and γγ dimers were denatured and trypsin digested to allow quantification of the selected signature peptides and their corresponding isotopically labelled peptide internal standard. The obtained linear dynamic ranges were determined to be 1.5-56 ng/mL and 0.64-167 ng/mL for NSEα and NSEγ (R2 = 0.88 and 0.97 respectively). Validation of the assay showed acceptable accuracy and precision for NSEα and NSEγ. The method was successfully applied to patient serum in which both isozymes were detected. Compared to the conventional immunoassay, substantially lower total NSE concentrations were measured in IA LC-MS/MS. With this multiplex IA LC-MS/MS assay, the clinical value of quantifying the individual isozymes can be explored. In addition, together with the calibrator described here, it may be applied to standardize NSE immunoassays across different platforms.
Assuntos
Isoenzimas , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Peptídeos , Fosfopiruvato Hidratase , Reprodutibilidade dos TestesRESUMO
OBJECTIVES: Pathologic subtyping of tissue biopsies is the gold standard for the diagnosis of lung cancer (LC), which could be complicated in cases of e.g. inconclusive tissue biopsies or unreachable tumors. The diagnosis of LC could be supported in a minimally invasive manner using protein tumor markers (TMs) and circulating tumor DNA (ctDNA) measured in liquid biopsies (LBx). This study evaluates the performance of LBx-based decision-support algorithms for the diagnosis of LC and subtyping into small- and non-small-cell lung cancer (SCLC and NSCLC) aiming to directly impact clinical practice. MATERIALS AND METHODS: In this multicenter prospective study (NL9146), eight protein TMs (CA125, CA15.3, CEA, CYFRA 21-1, HE4, NSE, proGRP and SCCA) and ctDNA mutations in EGFR, KRAS and BRAF were analyzed in blood of 1096 patients suspected of LC. The performance of individual and combined TMs to identify LC, NSCLC or SCLC was established by evaluating logistic regression models at pre-specified positive predictive values (PPV) of ≥95% or ≥98%. The most informative protein TMs included in the multi-parametric models were selected by recursive feature elimination. RESULTS: Single TMs could identify LC, NSCLC and SCLC patients with 46%, 25% and 40% sensitivity, respectively, at pre-specified PPVs. Multi-parametric models combining TMs and ctDNA significantly improved sensitivities to 65%, 67% and 50%, respectively. CONCLUSION: In patients suspected of LC, the LBx-based decision-support algorithms allowed identification of about two-thirds of all LC and NSCLC patients and half of SCLC patients. These models therefore show clinical value and may support LC diagnostics, especially in patients for whom pathologic subtyping is impossible or incomplete.
Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/genética , Carcinoma Pulmonar de Células não Pequenas/patologia , Estudos Prospectivos , Biomarcadores Tumorais , Fosfopiruvato Hidratase , Biópsia LíquidaRESUMO
Liquid biopsies have become of interest as minimally invasive ways to monitor treatment response in lung cancer patients. Circulating tumor DNA (ctDNA) and protein biomarkers are evaluated for their added value in monitoring therapy response and early detection of disease progression. Plasma and serum samples of non-small cell or small cell lung cancer patients were analyzed for driver mutations in ctDNA (EGFR, KRAS or BRAF) using droplet digital PCR and protein biomarkers (CA125, CEA, CA15.3, Cyfra 21-1, HE4, NSE, proGRP and SCCA) using electrochemiluminescence immunoassays. Biomarker concentration changes were compared with the outcome of CT-scans during therapy. The median difference of the concentration of ctDNA, CA125 and Cyfra21-1 was significantly lower in patients with partial response (PR) compared to patients with progressive disease (PD) on the first evaluation CT-scan (P<0.001, P=0.042 and P=0.020, respectively). A substantial agreement between ctDNA or CA125 response and radiographic response was observed (k=0.692 and k=0.792, respectively). The median difference of the concentration of ctDNA and Cyfra21-1 was also significantly lower in PR patients compared to PD patients at the last CT-scan during therapy (P<0.001 and P=0.026, respectively). An almost perfect agreement between ctDNA and radiographic response (k=0.827) and a moderate agreement between Cyfra21-1 response and radiographic response was observed (k=0.553). Serial testing of the concentration of ctDNA, Cyfra21-1, and possibly CA125 could be a useful added tool for monitoring therapy response and early detection of disease progression in lung cancer patients.
Assuntos
Biomarcadores Tumorais/metabolismo , Biópsia Líquida/métodos , Neoplasias Pulmonares/terapia , Idoso , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos ProspectivosRESUMO
Neuron-specific enolase (NSE) is a well-known biomarker for the diagnosis, prognosis and treatment monitoring of small-cell lung cancer (SCLC). Nevertheless, its clinical applicability is limited since serum NSE levels are influenced by hemolysis, leading to falsely elevated results. Therefore, this study aimed to develop a hemolysis correction equation and evaluate its role in SCLC diagnostics. Two serum pools were spiked with increasing amounts of hemolysate obtained from multiple individuals. A hemolysis correction equation was obtained by analyzing the relationship between the measured NSE concentration and the degree of hemolysis. The equation was validated using intentionally hemolyzed serum samples, which showed that the correction was accurate for samples with an H-index up to 30 µmol/L. Correction of the measured NSE concentration in patients suspected of lung cancer caused an increase in AUC and a significantly lower cut-off value for SCLC detection when compared to uncorrected results. Therefore, a hemolysis correction equation should be used to correct falsely elevated NSE concentrations. Results of samples with an H-index above 30 µmol/L should not be reported to clinicians. Application of the equation illustrates the importance of hemolysis correction in SCLC diagnostics and questions the correctness of the currently used diagnostic cut-off value.
RESUMO
Stabilization of protein-protein interactions (PPIs) holds great potential for therapeutic agents, as illustrated by the successful drugs rapamycin and lenalidomide. However, how such interface-binding molecules can be created in a rational, bottom-up manner is a largely unanswered question. We report here how a fragment-based approach can be used to identify chemical starting points for the development of small-molecule stabilizers that differentiate between two different PPI interfaces of the adapter protein 14-3-3. The fragments discriminately bind to the interface of 14-3-3 with the recognition motif of either the tumor suppressor protein p53 or the oncogenic transcription factor TAZ. This X-ray crystallography driven study shows that the rim of the interface of individual 14-3-3 complexes can be targeted in a differential manner with fragments that represent promising starting points for the development of specific 14-3-3 PPI stabilizers.