Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur J Cardiothorac Surg ; 29(5): 699-702, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16520053

RESUMO

OBJECTIVE: One of the complications of CPB is the systemic inflammatory response syndrome (SIRS). Recent developments tend to minimize the biological impact of CPB in using miniaturized closed circuit with reduced priming volume and less blood-air interface. The benefit of these miniaturized closed circuits in terms of inflammatory response has been proved in coronary surgery. However, in open heart surgery, the CPB circuit is no more closed and the benefit of the miniaturized set-up could disappear. The aim of the study is to compare the SIRS between standard and miniaturized circuits in aortic surgery. METHODS: Forty patients who underwent singular aortic valve replacement were randomly assigned either to a standard CPB (group A, n=20) or to a miniaturized CPB (group B, n=20). Pertinent clinical and surgical data were collected. Hematological parameters (leukocyte and neutrophil counts) and biochemical parameters (C-reactive protein, cytokine tests) were determined pre-, on and post-CPB. RESULTS: There were an increase in leukocyte and neutrophil counts and a decline in hematocrit in both groups. In both groups, there was a raise after CPB, in C-reactive protein, IL-6, TNF-alpha, neutrophil elastase, and IL-10. However, the raises of elastase and TNF-alpha were significantly lower after the weaning of miniaturized CPB (116+/-46 ng/ml and 10+/-4 pg/ml, respectively) compared to standard CPB (265+/-120 ng/ml, P=0.01 and 18+/-7 pg/ml, P=0.03). The raise of IL-10 is also lower with miniaturized circuit (15+/-6 pg/ml) compared to standard circuit (51+/-26, P=0.004). CONCLUSIONS: This study demonstrates in aortic surgery, the lesser inflammatory response of a miniaturized CPB compared to a standard CPB. However, there is always some inflammation after CPB and a small bio-reactive free perfusion circuit is still to be found in open heart surgery.


Assuntos
Valva Aórtica/cirurgia , Ponte Cardiopulmonar/efeitos adversos , Ponte Cardiopulmonar/instrumentação , Implante de Prótese de Valva Cardíaca , Síndrome de Resposta Inflamatória Sistêmica/etiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Interleucina-10/sangue , Interleucina-6/sangue , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Elastase Pancreática/sangue , Estudos Prospectivos , Síndrome de Resposta Inflamatória Sistêmica/imunologia , Fator de Necrose Tumoral alfa/metabolismo
2.
J Chromatogr B Analyt Technol Biomed Life Sci ; 781(1-2): 207-26, 2002 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-12450660

RESUMO

It is now widely accepted that increased total plasma homocysteine (tHcy) is a risk factor for cardiovascular disease. Hyperhomocysteinemia can be caused by impaired enzyme function as a result of genetic mutation or vitamin B (B(2), B(6), B(9), B(12)) deficiency. A lot of methods are now available for tHcy determination. High-pressure liquid chromatography (HPLC) with fluorescence detection are at present the most widely used methods but immunoassays, easier to use, begin to supplant in-house laboratory methods. In order to help with the choice of a main relevant homocysteine analytical method, the characteristics, performances and limits of the main current methods are reviewed. One major drawback among all these available methods is the transferability which is not clearly established to date. The impact of both inter-method and inter-laboratory variations on the interpretation of the tHcy results are discussed.


Assuntos
Homocisteína/sangue , Cromatografia/métodos , Eletroforese Capilar/métodos , Feminino , Homocisteína/fisiologia , Humanos , Imunoensaio/métodos , Masculino , Manejo de Espécimes
3.
Eur J Cardiothorac Surg ; 22(4): 527-33, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12297167

RESUMO

OBJECTIVE: Cardiopulmonary bypass (CPB) is known to cause part of the systemic inflammatory reaction after cardiac surgery that can be responsible for organ failure. A novel technique based on a minimal extracorporeal circulation (MECC(R)) system has been evaluated with regard to the inflammatory response in a prospective study involving patients undergoing coronary artery bypass grafting. METHODS: Sixty consecutive patients were randomly assigned to either standard normothermic CPB (n=30) or the MECC system, with a reduced priming volume, no aortic venting and no venous reservoir, excluding the blood-air interface (n=30). Specific evaluation of cytokine release (IL-1beta, IL-6, TNF-alpha), as well as neutrophil elastase secretion and beta-thromboglobulin release from platelets and S100 protein assay were performed. Serial blood samples were taken prior to the onset, after initiation, at the end and after weaning of the CPB; further samples were collected 6 and 24h after the end of the CPB. RESULTS: All patients were similar with regards to pre- and intra-operative characteristics and clinical outcomes were comparable for both groups. MECC system allowed a reduced hemodilution with a mean drop of the hematocrit of 8.5 vs. 15.3% (P<0.05). Mononuclear phagocytes dropped in a more important manner under standard CPB conditions (247+/-151 vs. 419+/-168, P=0.002), but both groups demonstrated a rise in monocyte count at the end of the CBP. No significant release of IL-1beta was observed in either group. By the end of CPB, IL-6 levels were significantly lower in the MECC group (38.8+/-19.6 vs. 87.9+/-78.9, P=0.04), despite a higher monocyte count. Plasma levels of TNF-alpha rised significantly more during standard CPB than with the MECC system (17.8+/-15.4 vs. 10.1+/-5.6, P=0.002). With MECC, the neutrophil elastase release was reduced (72.7+/-47.9 vs. 219.6+/-103.4, P=0.001). Platelet count remained at higher values with the minimal compared to standard CPB. It is noteworthy to consider that beta-thromboglobulin levels showed slightly lower platelet activation in the MECC group at all times of CPB (110.5+/-55.6 vs. 134.7+/-46.8, P=0.10). The pattern of release of S100 protein showed higher values in patients undergoing standard CPB than after MECC. CONCLUSIONS: The MECC system is suitable to maintain total extracorporeal circulation and demonstrates a lower inflammatory reaction when compared to standard CPB.


Assuntos
Ponte Cardiopulmonar , Ponte de Artéria Coronária , Doença das Coronárias/sangue , Doença das Coronárias/cirurgia , Oxigenação por Membrana Extracorpórea/métodos , Idoso , Método Duplo-Cego , Humanos , Interleucina-1/sangue , Interleucina-6/sangue , Contagem de Leucócitos , Elastase de Leucócito/sangue , Pessoa de Meia-Idade , Ativação Plaquetária , Contagem de Plaquetas , Estudos Prospectivos , Estatísticas não Paramétricas , Fator de Necrose Tumoral alfa/análise , beta-Tromboglobulina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA