Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Science ; 292(5516): 468-72, 2001 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-11292861

RESUMO

Hypoxia-inducible factor (HIF) is a transcriptional complex that plays a central role in the regulation of gene expression by oxygen. In oxygenated and iron replete cells, HIF-alpha subunits are rapidly destroyed by a mechanism that involves ubiquitylation by the von Hippel-Lindau tumor suppressor (pVHL) E3 ligase complex. This process is suppressed by hypoxia and iron chelation, allowing transcriptional activation. Here we show that the interaction between human pVHL and a specific domain of the HIF-1alpha subunit is regulated through hydroxylation of a proline residue (HIF-1alpha P564) by an enzyme we have termed HIF-alpha prolyl-hydroxylase (HIF-PH). An absolute requirement for dioxygen as a cosubstrate and iron as cofactor suggests that HIF-PH functions directly as a cellular oxygen sensor.


Assuntos
Proteínas de Ligação a DNA/metabolismo , Hidroxiprolina/metabolismo , Ligases , Proteínas Nucleares/metabolismo , Oxigênio/fisiologia , Pró-Colágeno-Prolina Dioxigenase/metabolismo , Proteínas/metabolismo , Fatores de Transcrição/metabolismo , Proteínas Supressoras de Tumor , Ubiquitina-Proteína Ligases , Sequência de Aminoácidos , Ácido Ascórbico/farmacologia , Hipóxia Celular , Proteínas de Ligação a DNA/química , Desferroxamina/farmacologia , Compostos Ferrosos/farmacologia , Humanos , Hidroxilação , Fator 1 Induzível por Hipóxia , Subunidade alfa do Fator 1 Induzível por Hipóxia , Dados de Sequência Molecular , Proteínas Nucleares/química , Mutação Puntual , Pró-Colágeno-Prolina Dioxigenase/antagonistas & inibidores , Estrutura Terciária de Proteína , Proteínas Recombinantes de Fusão/metabolismo , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Fatores de Transcrição/química , Células Tumorais Cultivadas , Ubiquitinas/metabolismo , Proteína Supressora de Tumor Von Hippel-Lindau
2.
J Am Soc Mass Spectrom ; 10(5): 414-22, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10222595

RESUMO

The ease of fragmentation of various charge states of protonated polypropylenamine (POPAM) dendrimers is investigated by surface-induced dissociation. Investigated are the protonated diaminobutane propylenamines [DAB(PA)n] DAB(PA)8 (1+ and 2+), DAB(PA)16 (2+ and 3+), and DAB(PA)32 (3+ and 4+). These ions have been proposed to fragment by charge-directed intramolecular nucleophilic substitution (SNi) reactions. Differences in relative fragment ion abundances between charge states can be related to the occupation of different protonation sites. These positions can be rationalized based on estimates of Coulomb energies and gas-phase basicities of the protonation/fragmentation sites. The laboratory collision energies at which the fragment ion current is approximately 50% of the total ion current were found to increase with the size, but to be independent of charge state of the protonated POPAM dendrimers. It is suggested that intramolecular Coulomb repulsion within the multiply protonated POPAM dendrimers selected for activation does not readily result in easier fragmentation, which is in accordance with the proposed fragmentation mechanism.


Assuntos
Poliaminas/química , Fenômenos Químicos , Físico-Química , Cromatografia Gasosa-Espectrometria de Massas , Prótons , Propriedades de Superfície
3.
J Mass Spectrom ; 36(12): 1260-8, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11754117

RESUMO

A novel tandem quadrupole mass spectrometer is described that enables gaseous collision-induced dissociation (CID) and surface-induced dissociation (SID) experiments. The instrument consists of a commercially available triple quadrupole mass spectrometer connected to an SID region and an additional, orthogonal quadrupole mass analyser. The performance of the instrument was evaluated using leucine-enkephalin, allowing a comparison between CID and SID, and with previous reports of other SID instruments. The reproducibility of SID data was assessed by replicate determinations of the collision energy required for 50% dissociation of leucine-enkephalin; excellent precision was observed (standard deviation of 0.6 eV) though, unexpectedly, the reproducibility of the equivalent figure for CID was superior. Several peptides were analysed using SID in conjunction with liquid secondary-ion mass spectrometry or electrospray; a comparison of the fragmentation of singly protonated peptide ions and the further dissociation of y-type fragments was consistent with the equivalence of the latter fragments to protonated peptides. Few product ions attributable to high-energy cleavages of amino acid side-chains were observed. The SID properties were investigated of a series of peptides differing only in the derivatization of a cysteine residue; similar decomposition efficiencies were observed for all except the cysteic acid analogue, which demonstrated significantly more facile fragmentation.


Assuntos
Espectrometria de Massas/instrumentação , Sequência de Aminoácidos , Angiotensinogênio/química , Bradicinina/análogos & derivados , Bradicinina/química , Cisteína/química , Dinorfinas/química , Encefalina Leucina/química , Fibrinopeptídeo A/química , Espectrometria de Massas/métodos , Dados de Sequência Molecular , Estrutura Molecular , Fragmentos de Peptídeos/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Termodinâmica