Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 102(6): 1140-1148, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37668110

RESUMO

BACKGROUND: Preprocedural computed tomography planning improves procedural safety and efficacy of transcatheter aortic valve implantation (TAVI). However, contemporary imaging modalities do not account for device-host interactions. AIMS: This study evaluates the value of preprocedural computer simulation with FEops HEARTguideTM on overall device success in patients with challenging anatomies undergoing TAVI with a contemporary self-expanding supra-annular transcatheter heart valve. METHODS: This prospective multicenter observational study included patients with a challenging anatomy defined as bicuspid aortic valve, small annulus or severely calcified aortic valve. We compared the heart team's transcatheter heart valve (THV) planning decision based on (1) conventional multislice computed tomography (MSCT) and (2) MSCT imaging with FEops HEARTguideTM simulations. Clinical outcomes and THV performance were followed up to 30 days. RESULTS: A total of 77 patients were included (median age 79.9 years (IQR 74.2-83.8), 42% male). In 35% of the patients, preprocedural planning changed after FEops HEARTguideTM simulations (change in valve size selection [12%] or target implantation height [23%]). A new permanent pacemaker implantation (PPI) was implanted in 13% and >trace paravalvular leakage (PVL) occurred in 28.5%. The contact pressure index (i.e., simulation output indicating the risk of conduction abnormalities) was significantly higher in patients with a new PPI, compared to those without (16.0% [25th-75th percentile 12.0-21.0] vs. 3.5% [25th-75th percentile 0-11.3], p < 0.01) The predicted PVL was 5.7 mL/s (25th-75th percentile 1.3-11.1) in patients with none-trace PVL, 12.7 (25th-75th percentile 5.5-19.1) in mild PVL and 17.7 (25th-75th percentile 3.6-19.4) in moderate PVL (p = 0.04). CONCLUSION: FEops HEARTguideTM simulations may provide enhanced insights in the risk for PVL or PPI after TAVI with a self-expanding supra-annular THV in complex anatomies.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Simulação por Computador , Estudos Prospectivos , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Tomografia Computadorizada Multidetectores/métodos , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA