1.
Ann Vasc Surg ; 74: 519.e7-519.e16, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33549777

RESUMO

BACKGROUND: The sympathetic nervous system (SNS) is important in the regulation of perfusion. Dorsal root ganglion stimulation (DRG-S) modulates sympathetic tone and is approved to treat complex regional pain syndrome, a disorder related to SNS dysfunction. We herein present 3 cases of DRG-S therapy to improve blood flow and symptoms of ischemia in peripheral arterial disease (PAD). METHODS: Patient 1 is a 44-year-old female with dry gangrene of the third and fourth digits of her right hand due to Raynaud's syndrome who was scheduled for amputation of the affected digits. DRG-S leads were placed at the right C6, 7, and 8 DRG. Pulse volume recordings (PVR) were measured at baseline and after DRG-S. Patient 2 is a 55-year-old female with a non-healing ulcer of her left foot secondary to PAD scheduled for a below the knee amputation who underwent a DRG-S trial with leads placed at the left L4 and L5 DRG followed by a spinal cord stimulation trial with leads placed at the T9-T10 spinal levels for comparison. Transcutaneous oximetry (TcPO2) was measured at baseline and after 3 days of each therapy. Patient 3 is a 69-year-old female with persistent left foot pain at rest secondary to PAD with DRG-S leads placed at the left L4 and S1 levels. RESULTS: All 3 patients experienced a significant reduction in pain with DRG-S, along with improvements in blood flow of the involved extremities, avoiding or limiting amputation. PVR improved dramatically with DRG-S in patient 1. A greater improvement in TcPO2 was seen with the DRG-S trial compared to spinal cord stimulation trial in patient 2. Patient 3 experienced an increase in walking distance and demonstrated long term efficacy and limb salvage at 32 months postimplantation. CONCLUSIONS: Modulation of SNS output from DRG-S through orthodromic and antidromic autonomic pathways is likely responsible for improving blood flow. DRG-S may be a treatment option for PAD.


Assuntos
Terapia por Estimulação Elétrica , Gânglios Espinais , Hemodinâmica , Isquemia/terapia , Doença Arterial Periférica/terapia , Adulto , Idoso , Amputação Cirúrgica , Feminino , Humanos , Isquemia/diagnóstico , Isquemia/fisiopatologia , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/fisiopatologia , Recuperação de Função Fisiológica , Fluxo Sanguíneo Regional , Resultado do Tratamento
2.
Neuromodulation ; 17(5): 465-71; discussion 471, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24612234

RESUMO

OBJECTIVE: The Epiducer lead delivery system is a novel lead delivery device that can be used to percutaneously implant S-Series paddle leads (St. Jude Medical, Plano, TX, USA) as well as multiple percutaneous leads obviating the need for laminectomy and/or multiple needle sticks, respectively. This study evaluates the safety and usage of the Epiducer lead delivery system. METHODS: An Institutional Review Board-approved observational data collection study was conducted to evaluate usage patterns of the Epiducer system. In addition to the number and frequency of different lead configurations, the following procedural aspects of the surgery were recorded during the evaluation: angle of entry, distance from entry to final lead placement, and physician feedback. Descriptive statistics on adverse events, procedural aspects, and patient outcomes were compiled. RESULTS: Data were collected from 163 patients across 25 investigational sites. Physicians successfully implanted patients using the Epiducer during 89% of the procedures. Seven possible lead configurations were implanted. There were 96% and 92% of physicians "satisfied" or "very satisfied" with accessing the epidural space and placing multiple leads with the Epiducer delivery system, respectfully. Eighty-nine percent of physicians were "satisfied" or "very satisfied" with implanting an S-Series paddle lead using the Epiducer delivery system. Ninety-five percent of physicians were "satisfied" or "very satisfied" with the Epiducer delivery system overall. Ten patients (6%) experienced adverse events. CONCLUSION: Results suggest that the Epiducer delivery system allows for the safe and successful percutaneous implantation of paddle leads and/or multiple lead configurations. Furthermore, physicians are satisfied with the Epiducer delivery system.


Assuntos
Dor Crônica/terapia , Espaço Epidural/fisiologia , Chumbo/efeitos adversos , Estimulação da Medula Espinal/métodos , Estimulação Elétrica Nervosa Transcutânea , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação Pessoal , Médicos/psicologia , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem