Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Eur Spine J ; 33(3): 1028-1043, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38353736

RESUMO

PURPOSE: In this study, we analyzed the use of a validated capture system (Spinal Adverse Events Severity system, SAVES V2) as a first non-technical skill to properly face the relevant problem of surgical complications (SCs) and adverse events (AEs) in spinal surgery. METHODS: We retrospectively collected AEs occurring in a tertiary referral center for spine surgery from January 2017 to January 2018 and classified them according to SAVES V2 system. We compared this collection of AEs with a prospective collection performed without any classification system. Univariate and multivariate logistic regression models were used to determined odds ratio (ORs) for selected potential risk factors of AEs and prolonged length of stay. RESULTS: Overall a higher number of AEs was retrospectively recorded using SAVES system compared to the prospective recording without the use of any capture system (97/336 vs 210/336, p < 0.001). The length of stay (LOS) increased in the group of complicated patients for all the procedures examined. In the non-oncological group, LOS was significantly higher for complicated patients compared to uncomplicated patients (F = 44.11, p = 0.0000). Similar results have been obtained in the oncological group of patients. In the multivariate regression model surgical time and postoperative AEs emerged as risk factors for prolonged LOS, while only the presence of previous surgeries was confirmed as risk factor for AEs. CONCLUSION: Considering that the rate of AEs and SCs in spinal surgery is still high despite the improvement of technical skills, we suggest the use of SAVES V2 capture system as a first-line tool to face the problem.


Assuntos
Complicações Pós-Operatórias , Coluna Vertebral , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Tempo de Internação , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Coluna Vertebral/cirurgia
2.
Sensors (Basel) ; 22(14)2022 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-35891039

RESUMO

This paper describes a compact electronic system employing a synchronous demodulation measurement method for the acquisition of pulsed-current signals. The fabricated prototype shows superior performance in terms of signal-to-noise ratio in comparison to conventional instrumentation performing free-running measurements, especially when extremely narrow pulses are concerned. It shows a reading error around 0.1% independently of the signal duty cycle (D) in the investigated D = 10−4−10−3 range. Conversely, high-precision electrometers display reading errors as high as 30% for a D = 10−4, which reduces to less than 1% only for D > 3 × 10−3. Field tests demonstrate that the developed front-end/readout electronics is particularly effective when coupled to dosimeters irradiated with the X-rays sourced by a medical linear accelerator. Therefore, it may surely be exploited for the real-time monitoring of the dosimeter output current, as required in modern radiotherapy techniques employing ultra-narrow pulses of high-energy photons or nuclear particles.


Assuntos
Eletrônica , Fótons , Radiometria , Razão Sinal-Ruído , Raios X
3.
Nano Lett ; 21(10): 4477-4483, 2021 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-33960788

RESUMO

Two-dimensional laser-induced periodic surface structures with a deep-subwavelength periodicity (80 nm ≈ λ/10) are obtained for the first time on diamond surfaces. The distinctive surface nanotexturing is achieved by employing a single step technique that relies on irradiation with two temporally delayed and cross-polarized femtosecond-laser pulses (100 fs duration, 800 nm wavelength, 1 kHz repetition rate) generated with a Michelson-like interferometer configuration, followed by chemical etching of surface debris. In this Letter, we demonstrate that, if the delay between two consecutive pulses is ≤2 ps, the 2D periodicity of nanostructures can be tuned by controlling the number of pulses irradiating the surface. Under scanning mode, the method is effective in treating uniformly large areas of diamond, so to induce remarkable antireflection properties able to enhance the absorptance in the visible up to 50 times and to pave the route toward the creation of metasurfaces for future diamond-based optoelectronic devices.

4.
Eur Spine J ; 30(10): 2775-2781, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34279722

RESUMO

PURPOSE: In the present report it is described the design, the manufacturing and the successful surgical implant of one of the first 3D custom titanium vertebra realized with Additive Manufacturing technique and its use for the spinal reconstruction after en-bloc resection for primary osteogenic sarcoma. METHODS: Clinical case presentation and the design of the 3D custom titanium vertebra was reported. It was also described the complex procedures adopted to evaluate the retrieved device from the histological point of view, as a tumor relapse hit the patient, one year after the reconstruction procedure. RESULTS: The histological evaluation confirmed that the resection technique exerts an important role in promoting bone formation: vertebral body osteotomies favored the reconstruction procedure and maximized the contact area between host bone/vertebral prosthesis thus favoring the bone tissue penetration and device colonization. CONCLUSION: The sharing of these results is very important as they represent the starting point for improving the knowledge starting from the evidence obtained in a challenging clinical condition and with post-operative treatments that could be never reproduced in preclinical model.


Assuntos
Neoplasias da Coluna Vertebral , Titânio , Vértebras Cervicais , Humanos , Recidiva Local de Neoplasia , Impressão Tridimensional , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/cirurgia
5.
Eur Spine J ; 29(5): 927-936, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31696338

RESUMO

PURPOSE: To investigate whether the World Health Organization Safety Surgical Checklist (SSC) is an effective tool to reduce complications in spinal surgery. METHODS: We retrospectively evaluated the clinical and radiological charts prospectively collected from patients who underwent a spinal surgery procedure from January 2010 to December 2012. The aim of this study was to compare the incidence of complications between two periods, from January to December 2010 (without checklist) and from January 2011 and December 2012 (with checklist), in order to assess the checklist's effectiveness. RESULTS: The sample size was 917 patients with an average of 30-month follow-up. The mean age was 52.88 years. The majority of procedures were performed for oncological diseases (54.4%) and degenerative diseases (39.8%). In total, 159 complications were detected (17.3%). The overall incidence of complications for trauma, infectious pathology, oncology, and degenerative disease was 22.2%, 19.2%, 18.4%, and 15.3%, respectively. No correlation was observed between the type of pathology and the complication incidence. We observed a reduction in the overall incidence of complications following the introduction of the SSC: In 2010 without checklist, the incidence of complications was 24.2%, while in 2011 and 2012, following the checklist introduction, the incidence of complications was 16.7% and 11.7%, respectively (mean 14.2%). CONCLUSIONS: The SSC seems to be an effective tool to reduce complications in spinal surgery. We propose to extend the use of checklist system also to the preoperative and postoperative phases in order to further reduce the incidence of complications. These slides can be retrieved under Electronic Supplementary Material.


Assuntos
Lista de Checagem , Segurança do Paciente , Humanos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos , Organização Mundial da Saúde
6.
Support Care Cancer ; 26(9): 3181-3186, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29600414

RESUMO

PURPOSE: Metastatic epidural spinal cord compression (MESCC) is radiologically defined as an epidural metastatic lesion causing the displacement of the spinal cord from its normal position in the vertebral canal. The purpose of this paper is the evaluation of the influence of timing of surgery on the chance of neurological recovery. METHODS: This is a retrospective observational case-control study performed on patients with MESCC from solid tumors surgically treated at our institute from January 2010 to December 2016. Patients included were divided in two groups depending on surgery that was performed within or after 24 h the admission to the hospital. Neurological status was assessed with American Spine Injury Association (ASIA) Impairment Scale. RESULTS: No statistically significant difference was observed in the variation of ASIA if surgery is performed within or after 24 h from the admission to the hospital. A statistically significant difference was observed after surgery in each group in the improvement of neurological status. A statistically significant difference was reported in the early post-operative complications in patients surgically treated within 24 h. CONCLUSION: MESCC management is challenge for spine surgeons and may represent an oncologic emergency and if not promptly diagnosed can lead to a permanent neurological damage. According to this study, there is no difference in the chance of neurological recovery if surgery is performed within or after 24 h the admission to hospital, but there is a greater rate of early post-operative complications when surgery is performed within 24 h from the admission to the hospital.


Assuntos
Descompressão Cirúrgica/métodos , Complicações Pós-Operatórias/etiologia , Compressão da Medula Espinal/complicações , Neoplasias da Coluna Vertebral/secundário , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Retrospectivos , Compressão da Medula Espinal/cirurgia , Tempo
7.
Eur Spine J ; 27(12): 3059-3063, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29372428

RESUMO

PURPOSE: Chordoma is a low-grade malignant tumor with recurrence and metastasis tendency that originates from embryonic notochordal remnants. The sacrococcygeal region is the most commonly involved site. The aim of this paper is to report the results of the use of cryosurgery in the excision of a giant recurrent sacral chordoma and review of pertinent literature. METHODS: A 64 years old female patient with a locally recurrent sacral chordoma came to our attention after ten interventions performed at another institute. A surgical treatment was performed using argon cryosurgery. RESULTS: In this case, it was not possible to perform a marginal or wide excision, but it was intralesional with the removal of three major blocks. The fragments sent for the histological analysis measured total 35 × 30 × 8 cm with a weight of 4.260 g. CONCLUSIONS: Given the gelatinous structure of the tumor and the possibility of contamination of operatory field, cryosurgery may be indicated when previous surgeries and the dimensions of tumor mass do not allow a resection with negative margins improving radiotherapy efficacy in the local control of tumor.


Assuntos
Cordoma/cirurgia , Criocirurgia/métodos , Recidiva Local de Neoplasia/cirurgia , Neoplasias da Coluna Vertebral/cirurgia , Cordoma/diagnóstico por imagem , Cordoma/patologia , Feminino , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Reoperação/métodos , Sacro , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/patologia , Tomografia Computadorizada por Raios X
8.
Eur Spine J ; 27(12): 3073-3083, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30039254

RESUMO

PURPOSE: Various techniques for anterior column reconstruction have been described after en bloc resection of spinal tumors. Limited evidence exists regarding one being superior to another. The purpose of this study is to evaluate 3D-printed vertebral bodies for spinal reconstruction after en bloc resection in the thoracolumbar spine. METHODS: Prospective observational study on custom-made 3D-printed titanium reconstruction of vertebral bodies after en bloc resection for spinal tumor was conducted between November 2015 and June 2017. 3D-printed vertebral bodies were monitored for mechanical complications such as (1) migration, (2) subsidence into the adjacent vertebral bodies, and/or (3) breakage. Complications and related details were recorded. RESULTS: Thirteen patients (7 females and 6 males) were enrolled, and reconstruction of the anterior column was performed using custom-made 3D-printed titanium prosthesis after en bloc resection for spinal tumor (8 primary bone tumors and 5 solitary metastases). Subsidence into the adjacent vertebral bodies occurred in all patients at both proximal and distal bone-implant interfaces; however, it was clinically irrelevant (asymptomatic, and no consequences on posterior instrumentation), in 11 out of 12 patients (92%). In 1 patient (#4), severity of the subsidence led to revision of the construct. At an average 10-month follow-up (range 2-16), 1 implant was removed due to local recurrence of the disease and 1 was revisioned due to progressive distal junctional kyphosis. CONCLUSION: Preliminary results from this series suggest that 3D printing can be effectively used to produce custom-made prosthesis for anterior column reconstruction. These slides can be retrieved under Electronic Supplementary Material.


Assuntos
Biomimética/métodos , Vértebras Lombares/cirurgia , Impressão Tridimensional , Desenho de Prótese , Neoplasias da Coluna Vertebral/cirurgia , Vértebras Torácicas/cirurgia , Adolescente , Adulto , Idoso , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/cirurgia , Estudos Prospectivos , Implantação de Prótese/métodos , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/secundário , Vértebras Torácicas/diagnóstico por imagem , Titânio , Tomografia Computadorizada por Raios X , Adulto Jovem
9.
Eur Spine J ; 26(Suppl 1): 58-62, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27554346

RESUMO

PURPOSE: We describe a rare case of solitary bone cyst involving the vertebral body of L4. INTRODUCTION: To the best of the authors' knowledge, only 15 cases of solitary bone cysts involving the spine have been reported previously. All the reported cases were treated surgically, including resection and curettage with or without bone grafting. In the current case, treatment was with steroid injection alone. METHOD: A cystic lesion involving the vertebral body of L4 was identified in a 16-year-old girl with persistent low back pain of 2 years' duration. According to the radiological characteristics of the lesion, a diagnosis of solitary bone cyst was suspected. The patient underwent surgical intervention with percutaneous steroid injection alone since there was no evidence of thinned cortex or pathological fracture. The patient was discharged 2 days after this intervention with resolution of the low back pain. RESULT: At the final follow-up 7 months after treatment, the patient was asymptomatic and the beginning of bony healing was evident. CONCLUSION: Herein, we reported an extremely rare case of solitary bone cyst involving the body of the fourth lumbar vertebra. Local steroid injection should be considered as a minimally invasive intervention for a solitary bone cyst involving the spinal column with no evidence of thinned cortex or pathological fracture.


Assuntos
Cistos Ósseos/tratamento farmacológico , Cortisona/administração & dosagem , Vértebras Lombares/patologia , Esteroides/administração & dosagem , Adolescente , Feminino , Humanos , Injeções , Dor Lombar/tratamento farmacológico , Resultado do Tratamento
10.
Eur Spine J ; 26(Suppl 1): 158-166, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28168344

RESUMO

PURPOSE: ABC is a benign lesion with unpredictable behavior. Its treatment is challenging, especially in poorly accessible surgical areas, such as spine and pelvis. Currently, the first-line treatment of ABC is repeated selective arterial embolization (SAE) until healing. Other options have been used with variable success rates. We propose an alternative treatment for spine aneurysmal bone cyst (sABC) based on the injection of concentrated autologous bone marrow. METHODS: We retrospectively report and analyze here two cases of patients, a 14-year-old girl and a 16-year-old boy, both affected by ABC in C2 vertebra which were impossible to treat by SAE. They were treated with single or repeated injection of concentrated autologous bone marrow into the lesion. Their follow-up period is 27 months for both patients. RESULTS: In the two cases reported here we observed a progressive ossification of the lesion, which was slow in one case, requiring three subsequent injections of concentrated bone marrow, and fast in the other case, beginning 1 month after the procedure. In both cases, the healing of the lesion was associated with symptom relief and the clinical status of the patients remains stable after 2 years. CONCLUSIONS: Although SAE can still be considered the first line in the treatment of ABC in the axial skeleton, new promising therapeutic procedures involving the use of mesenchymal stem cells are developing.


Assuntos
Vértebra Cervical Áxis/diagnóstico por imagem , Cistos Ósseos Aneurismáticos/terapia , Transplante de Medula Óssea/métodos , Embolização Terapêutica/métodos , Adolescente , Angiografia , Cistos Ósseos Aneurismáticos/diagnóstico por imagem , Feminino , Humanos , Injeções Intralesionais , Imageamento por Ressonância Magnética , Masculino , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Transplante Autólogo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA