1.
Br J Clin Pharmacol ; 86(12): 2424-2434, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32374030

RESUMO

AIMS: To demonstrate the bioequivalence of macitentan/tadalafil fixed-dose combination (FDC) tablets with single-component tablets of macitentan and tadalafil in healthy subjects. METHODS: Studies AC-077-101 and AC-077-103 were single-centre, open-label, single-dose, 2-period, randomized, crossover Phase 1 studies conducted in healthy subjects. Two FDCs were investigated: FDC-1 and FDC-2 in Study AC-077-101 and FDC-2 in Study AC-077-103. Both FDCs contained 10 mg/40 mg of macitentan/tadalafil and differed in excipients and coating materials used. In both studies, pharmacokinetic sampling over 216 hours was conducted, and pharmacokinetic parameters were derived using noncompartmental methods. RESULTS: Bioequivalence of macitentan, its active metabolite ACT-132577, and tadalafil was established for FDC-2 in both studies AC-077-101 and AC-077-103 in which tadalafil as a single component was sourced from the USA and EU, respectively, to fulfil regional regulatory requirements. The area under the plasma concentration-time curve and maximum plasma concentration with 90% confidence intervals of all components were entirely within the bioequivalence limits (0.8000-1.2500). No subject died and no serious adverse events were reported in either studies. CONCLUSION: The FDC-2 tablet containing 10 mg/40 mg of macitentan/tadalafil was bioequivalent to the free combination of 10 mg macitentan and 40 mg tadalafil (both US and EU sourced). Macitentan and tadalafil were well tolerated when administered as FDC or as a free combination.


Assuntos
Hipoglicemiantes , Metformina , Pirimidinas , Sulfonamidas , Tadalafila , Adolescente , Adulto , Área Sob a Curva , Estudos Cross-Over , Preparações de Ação Retardada , Combinação de Medicamentos , Feminino , Voluntários Saudáveis , Humanos , Hipoglicemiantes/farmacologia , Masculino , Pessoa de Meia-Idade , Pirimidinas/farmacologia , Sulfonamidas/farmacologia , Comprimidos , Tadalafila/farmacologia , Equivalência Terapêutica , Adulto Jovem
2.
Pharmacol Res Perspect ; 8(2): e00580, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32302056

RESUMO

To compare the pharmacokinetic (PK) properties of the pediatric dispersible tablet formulation of macitentan and the adult film-coated tablet formulation of macitentan in healthy subjects. A randomized, open-label, single-dose, two-sequence, two-period, crossover, Phase 1 study was conducted in 12 healthy adults. Subjects were randomized to one of the two possible treatment sequences A/B or B/A on Day 1 under fasted conditions. Treatment A was a single 10 mg dose of macitentan (film-coated adult formulation) and Treatment B was a single 10 mg dose of macitentan, consisting of two 5 mg dispersible tablets (pediatric formulation). PK sampling over 216 hours was conducted, and PK parameters were derived using non-compartmental methods. For macitentan, geometric means ratio of peak plasma concentrations (Cmax ), plasma concentration-time curve from zero to the time of the last quantifiable concentration (AUC0-t ), and plasma concentration-time curve from zero to infinity (AUC0-∞ ) were 1.140, 0.974, and 0.974, respectively. The corresponding 90% confidence intervals fell entirely within the referenced range of 0.8000 to 1.2500, which is used for evaluation of bioequivalence. These results indicate no significant differences between the pediatric dispersible tablet and the adult film-coated tablet. Both formulations were well tolerated. The pediatric dispersible tablet is biocomparable to the adult film-coated tablet formulation.


Assuntos
Pirimidinas/farmacocinética , Sulfonamidas/farmacocinética , Adolescente , Adulto , Área Sob a Curva , Disponibilidade Biológica , Criança , Estudos Cross-Over , Jejum/metabolismo , Voluntários Saudáveis , Humanos , Masculino , Pirimidinas/administração & dosagem , Pirimidinas/sangue , Sulfonamidas/administração & dosagem , Sulfonamidas/sangue , Comprimidos , Adulto Jovem
3.
Bioanalysis ; 12(14): 1033-1038, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32706625

RESUMO

In this paper, the European Bioanalysis Forum reports back from the discussions with software developers, involved in regulated bioanalysis software solutions, on agreeing to data transfer specification in the bioanalytical labs' LC-MS workflows as part of today's Data Integrity (DI) challenges. The proposed specifications aim at identifying what consists of a minimum dataset, that is, which are the pre-identified fields to be included in DI proof bidirectional data transfer between LC-MS and information management systems. The proposal is an attempt from the European Bioanalysis Forum to facilitate new software solutions becoming available to increase compliance related to DI in today's LC-MS workflows. The proposal may also serve as a template and inspiration for new data transfer solutions in other workflows.


Assuntos
Bioensaio/métodos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Europa (Continente) , Humanos
4.
Bioanalysis ; 11(13): 1227-1231, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31452404

RESUMO

In this conference report, we summarize the main findings and messages from a workshop on 'Data Integrity'. The workshop was held at the 11th European Bioanalysis Forum Open (EBF) Symposium in Barcelona (21-23 November 2018), in collaboration with the Medicines and Health products Regulatory Agency to provide insight and understanding of regulatory data integrity expectations. The workshop highlighted the importance of engaging with software developers to address the gap between industry's data integrity needs and current system software capabilities. Delegates were also made aware of the importance of implementing additional procedural controls to mitigate the risk associated with using systems that do not fully meet data integrity requirements.


Assuntos
Bioensaio , Preparações Farmacêuticas/análise , Bioensaio/normas , Confiabilidade dos Dados , Regulamentação Governamental , Preparações Farmacêuticas/normas , Controle de Qualidade
5.
Bioanalysis ; 8(19): 2065-70, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27416776

RESUMO

Interference testing of co-medication in bioanalytical method validation has become an area of debate in view of the increased specificity offered by current state-of-the-art technology in both LC-MS/MS and ligand-binding assay platforms. In view of this, and considering the extensive experience within the European Bioanalysis Forum member companies, we evaluated the impact of co-medication on the performance of hundreds of bioanalytical methods with the aim of providing a science-based recommendation on how to evaluate and document potential interference from co-medication on the PK parameters in clinical studies in patients and volunteers.


Assuntos
Cromatografia Líquida de Alta Pressão , Preparações Farmacêuticas/análise , Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão/normas , Interações Medicamentosas , Humanos , Ligantes , Preparações Farmacêuticas/normas , Controle de Qualidade , Espectrometria de Massas em Tandem/normas
6.
Bioanalysis ; 3(14): 1567-75, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21749218

RESUMO

Over the last few years bioanalysts, pharmacokineticists and clinical investigators have rediscovered the technique of dried blood spots. The revival has provided pharmaceutical R&D a wealth of opportunities to optimize the drug-discovery and development process with respect to animal and patient ethics, new scientific insights and costs savings. On the bioanalytical front, multiple experiments have been performed and a lot of experience has been gained. Nevertheless, the technique still has a number of bioanalytical challenges. The European Bioanalysis Forum discussed the advantages and hurdles of the technique and summarized their current thinking in a recommendation on the validation of bioanalytical methods for dried blood spots, which can be used as a cornerstone for further discussions and experiments.


Assuntos
Técnicas de Química Analítica/métodos , Técnicas de Química Analítica/normas , Teste em Amostras de Sangue Seco/métodos , Teste em Amostras de Sangue Seco/normas , Preparações Farmacêuticas/sangue , Anticoagulantes/química , Europa (Continente) , Hematócrito , Humanos , Reprodutibilidade dos Testes
7.
Bioanalysis ; 3(8): 833-8, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21510756

RESUMO

The European Bioanalysis Forum is a bioanalytical nonprofit organization comprised of European pharmaceutical companies (27 members to date) and currently expanding to include CROs as well. The European Bioanalysis Forum provides a broad European bioanalytical network for the discussion of scientific, technological and regulatory topics of bioanalytical interest. The 3rd Annual Open Symposium was again much anticipated after the two previous successful meetings. The symposium included sessions on thinking outside the 'commodity' box, bioanalytical challenges with blood, global harmonization, assay platforms, dried blood spots, immunogenicity, matrix effects, anomalous results, biomarkers and two plenary technology sessions hosted by the Platinum sponsors. Experts and key opinion leaders were invited as guest speakers. A total of 424 delegates registered from 113 companies representing a large percentage of the European bioanalytical community. In addition to 48 oral presentations, 88 posters were presented and there was a vendor exposition of 40 companies.


Assuntos
Testes de Química Clínica/métodos , Indústria Farmacêutica , Bioensaio , Biomarcadores/análise , Testes de Química Clínica/normas , Testes de Química Clínica/tendências , Europa (Continente) , Organizações sem Fins Lucrativos , Preparações Farmacêuticas/análise
8.
Bioanalysis ; 1(6): 1049-56, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21083073

RESUMO

Following intensive discussions, review, alignment of procedures and multiple surveys among their member companies, the European Bioanalysis Forum (EBF) is providing a recommendation on how to integrate incurred sample reproducibility (ISR) in the bioanalytical process. The recommendation aims to provide guidance throughout the lifecycle of a validated method, including the application of the method in study support. In its recommendation, the EBF considers both the internal discussions with EBF member companies, as well as the input provided in international meetings where ISR was discussed. The ultimate goal of the EBF recommendation is to ensure that bioanalytical methods can provide accurate and reproducible concentration data for pharmacokinetic and/or toxicokinetic evaluation, without any compromise, while safeguarding the optimal use of laboratory resources.


Assuntos
Métodos Analíticos de Preparação de Amostras/normas , Preparações Farmacêuticas/análise , Europa (Continente) , Guias como Assunto , Humanos , Farmacocinética , Reprodutibilidade dos Testes , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA