Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Cancer Biomark ; 24(4): 405-419, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30932880

RESUMO

We introduce here recently developed highly resolved Sub-Terahertz resonance spectroscopy of biological molecules and cells combined with molecular dynamics (MD) computational analysis as a new approach for optical visualization and quantification of the presence of microRNAs, particularly the mir-200 family, as potential biomarkers in samples from tissue of epithelial ovarian cancers for disease early detection, analysis, prognosis and treatment.METHOD: A set of samples for this study was prepared from anonymized archival formalin-fixed, paraffin-embedded ovarian epithelial tissue containing regions of invasive neoplastic cells from cases of high-histologic grade serous papillary ovarian carcinoma. Control samples were normal mucosa from fallopian tubes of patients with no known malignancy. Spectroscopic characterization of tissue samples in this study was performed using a continuous wave, frequency domain automated spectrometer operating at room temperature in the spectral region of 310-500 GHz. The spectral results were compared with molecular dynamics simulations and absorption coefficient calculations utilized to predict the absorption spectra.RESULTS: The characteristic spectroscopic features in absorption spectra, particularly the presence of absorption peaks near 13 cm-1 have been identified as cancer indicators. Tissue samples heterogeneity, reflected by diverse spectral signatures, provides additional, very specific information that may be used for identification of cancer subtypes, clinical behavior or sensitivity to specific therapies. Further work is warranted to determine if this signature can be detected in bio-fluids from ovarian cancer patients. If strongly correlated with cancer burden, it may then be investigated as a potential new biomarker for disease monitoring, and also perhaps as a biomarker for cancer screening.


Assuntos
Biomarcadores Tumorais , Técnicas de Diagnóstico Molecular , Neoplasias Ovarianas/diagnóstico , Neoplasias Ovarianas/genética , Análise Espectral , Feminino , Humanos , Metástase Linfática , Gradação de Tumores , Estadiamento de Neoplasias , Análise Espectral/métodos
2.
J Phys Chem A ; 112(47): 12090-6, 2008 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-18928269

RESUMO

This work combines experimental and theoretical approaches to investigate terahertz absorption spectra of the DNA formed by the sequence oligomer 5'-CCGGCGCCGG-3'. The three-dimensional structure of this self-complimentary DNA decamer has been well-studied, permitting us to perform direct identification of the low-frequency phonon modes associated with specific conformation and to conduct comprehensive computer simulations. Two modeling techniques, normal-mode analysis and nanosecond molecular dynamics with explicit solvent molecules, were employed to extract the low-frequency vibrational modes based on which the absorption spectra were calculated. The absorption spectra of the DNA decamer in aqueous solution were measured in the frequency range 10-25 cm(-1) using the terahertz Fourier transform infrared spectroscopy. Multiple well-resolved and reproducible resonance modes were observed. When calculated and experimental spectra were compared, the spectrum based on molecular dynamics simulations showed a better correlation with the experimental spectra than the one based on normal-mode analysis. These results demonstrate that there exist a considerable number of active low-frequency phonon modes in this short DNA duplex.


Assuntos
DNA/química , Oligodesoxirribonucleotídeos/química , Absorção , Sequência de Bases , Dicroísmo Circular , Simulação por Computador , DNA/genética , Modelos Moleculares , Conformação de Ácido Nucleico , Oligodesoxirribonucleotídeos/genética
3.
Faraday Discuss ; 171: 179-93, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25415676

RESUMO

Hydrogen bonds (H-bonds) in biological macromolecules are important for the molecular structure and functions. Since interactions via hydrogen bonds are weaker than covalent bonds, it can be expected that atomic movements involving H-bonds have low frequency vibrational modes. Sub-Terahertz (sub-THz) vibrational spectroscopy that combines measurements with molecular dynamics (MD) computational prediction has been demonstrated as a promising approach for biological molecule characterization. Multiple resonance absorption lines have been reported. The knowledge of relaxation times of atomic oscillations is critical for the successful application of THz spectroscopy for hydrogen bond characterization. The purpose of this work is to use atomic oscillations in the 0.35-0.7 THz range, found from molecular dynamic (MD) simulations of E.coli thioredoxin (2TRX), to study relaxation dynamics of two intra-molecular H-bonds, OH-N and OH-C. Two different complimentary techniques are used in this study, one is the analysis of the statistical distribution of relaxation time and dissipation factor values relevant to low frequency oscillations, and the second is the analysis of the autocorrelation function of low frequency quasi-periodic movements. By studying hydrogen bond atomic displacements, it was found that the atoms are involved in a number of collective oscillations, which are characterized by different relaxation time scales ranging from 2-3 ps to more than 150 ps. The existence of long lasting relaxation processes opens the possibility to directly observe and study H-bond vibrational modes in sub-THz absorption spectra of bio-molecules if measured with an appropriate spectral resolution. The results of measurements using a recently developed frequency domain spectroscopic sensor with a spectral resolution of 1 GHz confirm the MD analysis.


Assuntos
Escherichia coli/química , Simulação de Dinâmica Molecular , Tiorredoxinas/química , Ligação de Hidrogênio
4.
J Mol Model ; 18(5): 2209-18, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-21947449

RESUMO

Sub-terahertz (THz) vibrational modes of the protein thioredoxin in a water environment were simulated using molecular dynamics (MD) in order to find the conditions needed for simulation convergence, improve the correlation between experimental and simulated absorption frequencies, and ultimately enhance the predictive capabilities of computational modeling. Thioredoxin from E. coli was used as a model molecule for protocol development and to optimize the simulation parameters. The empirically parameterized software packages Amber 8 and 10 were used in this work. Using atomic trajectories from the constant energy and volume MD simulations, thioredoxin's sub-THz vibrational spectra and absorption coefficients were calculated in a quasi-harmonic approximation. An optimal production run length ~100 ps was found, in agreement with experimental data on thioredoxin relaxation dynamics. At the same time, a new procedure was developed for averaging correlation matrices of atomic coordinates in MD simulations. In particular, the open source package ptraj was edited to improve a matrix-analyzing function. Averaging only six matrices gave much more consistent results, with absorption peak intensities exceeding those from the individual spectra and a rather good correlation between simulated vibrational frequencies and experimental data.


Assuntos
Proteínas de Escherichia coli/química , Escherichia coli/química , Simulação de Dinâmica Molecular , Software , Tiorredoxinas/química , Água/química , Absorção , Ligação de Hidrogênio , Ligação Proteica , Espectroscopia Terahertz , Interface Usuário-Computador , Vibração
5.
Phys Rev Lett ; 98(15): 153906, 2007 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-17501354

RESUMO

In this work, a theoretical study of the coupling of TM polarized subterahertz (THz) radiation with periodic semiconductor rectangular slot arrays was conducted, using InSb as an example. Simulation results showed that the structure with 4-12 microm thickness provides over a 20-30-fold increase in the electric field at slot edges in a nanosize region ( approximately 500 nm). The enhancement of the THz electromagnetic field extends across the slots and reaches peak values at the edges due to discontinuity effects. Because of the strong local electromagnetic field enhancement, the structure can potentially be used for the development of novel biophotonic sensors, leading to improved detection sensitivity.


Assuntos
Antimônio/química , Índio/química , Modelos Teóricos , Semicondutores , Simulação por Computador , Radiação não Ionizante , Análise Espectral/métodos
6.
Philos Trans A Math Phys Eng Sci ; 362(1815): 365-74; discussion 374-7, 2004 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-15306526

RESUMO

Terahertz spectroscopy has long been used as an important measurement tool in fields such as radio astronomy, physical chemistry, atmospheric studies and plasma research. More recently terahertz technology has been used to develop an exciting new technique to investigate the properties of a wide range of biological materials. Although much research remains before a full understanding of the interaction between biomaterials and terahertz radiation is developed, these initial studies have created a compelling case for further scientific study. Also, the potential development of practical tools to detect and identify biological materials such as biological-warfare agents and food contaminants, or of medical diagnostic tools, is driving the need for improved terahertz technology. In particular, improved terahertz sources and detectors that can be used in practical spectroscopy systems are needed. This paper overviews some of the recent measurements of the terahertz spectra of biomaterials and the ongoing efforts to create an all-solid-state technology suitable not only for improved scientific experiments but also for military and commercial applications.


Assuntos
Biopolímeros/análise , Biopolímeros/metabolismo , Espectrofotometria Infravermelho/instrumentação , Espectrofotometria Infravermelho/métodos , Tomografia de Coerência Óptica/instrumentação , Tomografia de Coerência Óptica/métodos , Transdutores , Desenho de Equipamento , Espectrofotometria Infravermelho/tendências , Tomografia de Coerência Óptica/tendências
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA