Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
1.
Magn Reson Med ; 80(4): 1556-1567, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29488251

RESUMO

PURPOSE: Dixon-based fat suppression has recently gained interest for dynamic contrast-enhanced MRI, but multi-echo techniques require longer scan times and reduce temporal resolution compared to single-echo alternatives without fat suppression. The purpose of this work is to demonstrate accelerated single-echo Dixon imaging with high spatial and temporal resolution. THEORY AND METHODS: Real-valued water and fat images can be obtained from a single measurement if the shared initial phase and that due to ΔB0 are assumed known a priori. An expression for simultaneous sensitivity encoding (SENSE) unfolding and fat-water separation is derived for the general undersampling case, and simplified under the special case of uniform Cartesian undersampling. In vivo experiments were performed in extremities and brain with SENSE acceleration factors of up to R = 8. RESULTS: Single-echo Dixon reconstruction of highly undersampled data was successfully demonstrated. Dynamic contrast-enhanced water and fat images provided high spatial and temporal resolution dynamic images with image update times shorter than previous single-echo Dixon work. CONCLUSION: Time-resolved contrast-enhanced MRI with single-echo Dixon fat suppression shows high image quality, improved vessel delineation, and reduced sensitivity to motion when compared to time-subtraction methods.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Tecido Adiposo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Meios de Contraste , Mãos/irrigação sanguínea , Mãos/diagnóstico por imagem , Humanos , Processamento de Sinais Assistido por Computador , Água/química
2.
Magn Reson Med ; 80(1): 231-238, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29194738

RESUMO

PURPOSE: To implement a reduced field of view (rFOV) technique for cardiac MR elastography (MRE) and to demonstrate the improvement in image quality of both magnitude images and post-processed MRE stiffness maps compared to the conventional full field of view (full-FOV) acquisition. METHODS: With Institutional Review Board approval, 17 healthy volunteers underwent both full-FOV and rFOV cardiac MRE scans using 140-Hz vibrations. Two cardiac radiologists blindly compared the magnitude images and stiffness maps and graded the images based on several image quality attributes using a 5-point ordinal scale. Fisher's combined probability test was performed to assess the overall evaluation. The octahedral shear strain-based signal-to-noise ratio (OSS-SNR) and median stiffness over the left ventricular myocardium were also compared. RESULTS: One volunteer was excluded because of an inconsistent imaging resolution during the exam. In the remaining 16 volunteers (9 males, 7 females), the rFOV scans outperformed the full-FOV scans in terms of subjective image quality and ghosting artifacts in the magnitude images and stiffness maps, as well as the overall preference. The quantitative measurements showed that rFOV had significantly higher OSS-SNR (median: 1.4 [95% confidence interval (CI): 1.2-1.5] vs. 2.1 [95% CI: 1.8-2.4]), P < 0.05) compared to full-FOV. Although no significant change was found in the median myocardial stiffness between the 2 scans, we observed a decrease in the stiffness variation within the myocardium from 2.1 kPa (95% CI: [1.9, 2.3]) to 1.9 kPa (95% CI: [1.7, 2.0]) for full-FOV and rFOV, respectively (P < 0.05) in a subgroup of 7 subjects with ghosting present in the myocardium. CONCLUSION: This pilot volunteer study demonstrated that rFOV cardiac MRE has the capability to reduce ghosting and to improve image quality in both MRE magnitude images and stiffness maps. Magn Reson Med 80:231-238, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.


Assuntos
Imagem Ecoplanar/métodos , Técnicas de Imagem por Elasticidade/métodos , Coração/diagnóstico por imagem , Espectroscopia de Ressonância Magnética/métodos , Adulto , Algoritmos , Artefatos , Feminino , Voluntários Saudáveis , Ventrículos do Coração/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Lipídeos , Masculino , Miocárdio/patologia , Imagens de Fantasmas , Projetos Piloto , Probabilidade , Ondas de Rádio , Radiologia , Resistência ao Cisalhamento , Razão Sinal-Ruído , Estresse Mecânico , Adulto Jovem
3.
J Am Soc Nephrol ; 28(9): 2777-2785, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28461553

RESUMO

Atherosclerotic renovascular disease (RVD) reduces renal blood flow (RBF) and GFR and accelerates poststenotic kidney (STK) tissue injury. Preclinical studies indicate that mesenchymal stem cells (MSCs) can stimulate angiogenesis and modify immune function in experimental RVD. We assessed the safety and efficacy of adding intra-arterial autologous adipose-derived MSCs into STK to standardized medical treatment in human subjects without revascularization. The intervention group (n=14) received a single infusion of MSC (1.0 × 105 or 2.5 × 105 cells/kg; n=7 each) plus standardized medical treatment; the medical treatment only group (n=14) included subjects matched for age, kidney function, and stenosis severity. We measured cortical and medullary volumes, perfusion, and RBF using multidetector computed tomography. We assessed tissue oxygenation by blood oxygen level-dependent MRI and GFR by iothalamate clearance. MSC infusions were well tolerated. Three months after infusion, cortical perfusion and RBF rose in the STK (151.8-185.5 ml/min, P=0.01); contralateral kidney RBF increased (212.7-271.8 ml/min, P=0.01); and STK renal hypoxia (percentage of the whole kidney with R2*>30/s) decreased (12.1% [interquartile range, 3.3%-17.8%] to 6.8% [interquartile range, 1.8%-12.9%], P=0.04). No changes in RBF occurred in medical treatment only subjects. Single-kidney GFR remained stable after MSC but fell in the medical treatment only group (-3% versus -24%, P=0.04). This first-in-man dose-escalation study provides evidence of safety of intra-arterial infusion of autologous MSCs in patients with RVD. MSC infusion without main renal artery revascularization associated with increased renal tissue oxygenation and cortical blood flow.


Assuntos
Aterosclerose/terapia , Rim/irrigação sanguínea , Transplante de Células-Tronco Mesenquimais , Obstrução da Artéria Renal/terapia , Circulação Renal , Idoso , Antagonistas de Receptores de Angiotensina/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Aterosclerose/fisiopatologia , Feminino , Taxa de Filtração Glomerular , Humanos , Hipóxia/terapia , Infusões Intra-Arteriais , Rim/diagnóstico por imagem , Rim/fisiopatologia , Imageamento por Ressonância Magnética , Masculino , Transplante de Células-Tronco Mesenquimais/efeitos adversos , Tomografia Computadorizada Multidetectores , Oxigênio/sangue , Obstrução da Artéria Renal/fisiopatologia , Transplante Autólogo , Fator A de Crescimento do Endotélio Vascular/sangue , Fator C de Crescimento do Endotélio Vascular/sangue
4.
Can Assoc Radiol J ; 69(1): 78-91, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29458957

RESUMO

The atrioventricular (AV) groove constitutes the anatomic space separating the atria and ventricles. The AV groove is often difficult to visualize at echocardiography, and suspected lesions can be further assessed with cardiac computed tomography or magnetic resonance imaging. AV groove lesions may originate from within the AV groove or extend into this space from adjacent structures. The differential diagnosis for AV groove lesions is often wide, but a precise diagnosis can sometimes be made. This pictorial essay illustrates the magnetic resonance imaging and computed tomography appearance of common and uncommon AV groove lesions, and attempts to provide a logical framework for differential diagnosis when confronted with a known or suspected lesion at cross-sectional imaging.


Assuntos
Neoplasias Cardíacas/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
5.
Nephrol Dial Transplant ; 31(11): 1855-1863, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27474749

RESUMO

BACKGROUND: Atherosclerotic renal artery stenosis (ARAS) reduces renal blood flow (RBF), ultimately leading to kidney hypoxia and inflammation. Insulin-like growth factor binding protein-7 (IGFBP-7) and tissue inhibitor of metalloproteinases-2 (TIMP-2) are biomarkers of cell cycle arrest, often increased in ischemic conditions and predictive of acute kidney injury (AKI). This study sought to examine the relationships between renal vein levels of IGFBP-7, TIMP-2, reductions in RBF and postcontrast hypoxia as measured by blood oxygen level-dependent (BOLD) magnetic resonance imaging. METHODS: Renal vein levels of IGFBP-7 and TIMP-2 were obtained in an ARAS cohort (n= 29) scheduled for renal artery stenting and essential hypertensive (EH) healthy controls (n = 32). Cortical and medullary RBFs were measured by multidetector computed tomography (CT) immediately before renal artery stenting and 3 months later. BOLD imaging was performed before and 3 months after stenting in all patients, and a subgroup (N = 12) underwent repeat BOLD imaging 24 h after CT/stenting to examine postcontrast/procedure levels of hypoxia. RESULTS: Preintervention IGFBP-7 and TIMP-2 levels were elevated in ARAS compared with EH (18.5 ± 2.0 versus 15.7 ± 1.5 and 97.4 ± 23.1 versus 62.7 ± 9.2 ng/mL, respectively; P< 0.0001); baseline IGFBP-7 correlated inversely with hypoxia developing 24 h after contrast injection (r = -0.73, P< 0.0001) and with prestent cortical blood flow (r = -0.59, P= 0.004). CONCLUSION: These data demonstrate elevated IGFBP-7 and TIMP-2 levels in ARAS as a function of the degree of reduced RBF. Elevated baseline IGFBP-7 levels were associated with protection against postimaging hypoxia, consistent with 'ischemic preconditioning'. Despite contrast injection and stenting, AKI in these high-risk ARAS subjects with elevated IGFBP-7/TIMP-2 was rare and did not affect long-term kidney function.


Assuntos
Aterosclerose/complicações , Biomarcadores/sangue , Meios de Contraste/efeitos adversos , Hipóxia/induzido quimicamente , Rim/diagnóstico por imagem , Obstrução da Artéria Renal/sangue , Circulação Renal/fisiologia , Idoso , Aterosclerose/sangue , Aterosclerose/fisiopatologia , Pontos de Checagem do Ciclo Celular , Feminino , Humanos , Hipóxia/sangue , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/sangue , Rim/irrigação sanguínea , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Obstrução da Artéria Renal/etiologia , Obstrução da Artéria Renal/fisiopatologia , Inibidor Tecidual de Metaloproteinase-2/sangue
6.
Can Assoc Radiol J ; 67(2): 149-57, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26831730

RESUMO

The perirenal space can be involved by a variety of neoplastic, inflammatory, infectious, and proliferative disorders. Magnetic resonance imaging is often an ideal technique for identification and staging of lesions arising within the perirenal space, with its superior soft tissue characterization as well as its ability to visualize extension into blood vessels and adjacent organs. This pictorial essay describes the magnetic resonance imaging appearance of a variety of pathologies which can arise from or involve the perirenal space, and provides a framework for categorization and differential diagnosis of these lesions.


Assuntos
Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Imageamento por Ressonância Magnética , Neoplasias Ureterais/diagnóstico por imagem , Neoplasias das Glândulas Suprarrenais/patologia , Glândulas Suprarrenais/patologia , Humanos , Rim/diagnóstico por imagem , Rim/patologia , Neoplasias Renais/patologia , Espaço Retroperitoneal , Ureter/diagnóstico por imagem , Ureter/patologia , Neoplasias Ureterais/patologia
7.
Abdom Imaging ; 40(4): 766-75, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25805619

RESUMO

PURPOSE: To compare accuracy of morphological features of liver on MRI and liver stiffness with MR elastography (MRE) for detection of significant liver fibrosis and cirrhosis. MATERIALS AND METHODS: In this retrospective study, we evaluated 62 patients who underwent liver MRI with MRE and histological confirmation of liver fibrosis within 6 months. Two radiologists, blinded to histology results, independently evaluated liver parenchyma texture, surface nodularity, signs of volumetric changes, and portal hypertension for presence of significant fibrosis and cirrhosis. Two more readers independently calculated mean liver stiffness values with MRE. Interobserver agreement was evaluated with kappa and intra-class correlation coefficient (ICC) analysis. Diagnostic accuracy was assessed with area under receiver operating characteristic (AUROC) analysis. Comparison of AUROCs of MRI and MRE was performed. RESULTS: Liver fibrosis was present in 37 patients. The interobserver agreement was poor to good (κ = 0.12-0.74) for MRI features and excellent for MRE (ICC 0.97, 95% CI 0.95-0.98). MRI features had 48.5%-87.9% sensitivity, 55.2%-100% specificity, and 71.5%-81.6% accuracy/for detection of significant fibrosis. MRE performed better with 100% sensitivity, 96.5% specificity, and 98.9% accuracy. For the detection of cirrhosis, MRE performed better than MRI features with 88.2% sensitivity (vs. 41.2%-82.3%), 91.1% specificity (vs. 64.4%-95.6%), and 93.5% accuracy (vs. 60.6%-80.5%). Among the MRI features, surface nodularity and overall impression had the best accuracies of 80.3% and 81.6% for detection of significant fibrosis, respectively. For cirrhosis, parenchyma texture and overall impression had the best accuracies of 80.5% and 79.7%, respectively. Overall, MRE had significantly greater AUROC than MRI features for detection of both significant fibrosis (0.98.9 vs 0.71-0.82, P < 0.001) and cirrhosis (0.93.5 vs. 0.61-0.80.5, P < 0.01). CONCLUSION: MRE is superior to MRI for the non-invasive diagnosis of significant liver fibrosis and cirrhosis.


Assuntos
Técnicas de Imagem por Elasticidade , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Feminino , Humanos , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
8.
Radiology ; 272(1): 241-51, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24635676

RESUMO

PURPOSE: To determine the feasibility of using real-time fluoroscopic tracking for bolus-chase magnetic resonance (MR) angiography of peripheral vasculature to image three stations from the aortoiliac bifurcation to the pedal arteries. MATERIALS AND METHODS: This prospective study was institutional review board approved and HIPAA compliant. Eight healthy volunteers (three men; mean age, 48 years; age range, 30-81 years) and 13 patients suspected of having peripheral arterial disease (five men; mean age, 67 years; age range, 47-81 years) were enrolled and provided informed consent. All subjects were imaged with the fluoroscopic tracking MR angiographic protocol. Ten patients also underwent a clinical computed tomographic (CT) angiographic runoff examination. Two readers scored the MR angiographic studies for vessel signal intensity and sharpness and presence of confounding artifacts and venous contamination at 35 arterial segments. Mean aggregate scores were assessed. The paired MR angiographic and CT angiographic studies also were scored for visualization of disease, reader confidence, and overall diagnostic quality and were compared by using a Wilcoxon signed rank test. RESULTS: Real-time fluoroscopic tracking performed well technically in all studies. Vessel segments were scored good to excellent in all but the following categories: For vessel signal intensity and sharpness, the abdominal aorta, iliac arteries, distal plantar arteries, and plantar arch were scored as fair to good; and for presence of confounding artifacts, the abdominal aorta and iliac arteries were scored as fair. The MR angiograms and CT angiograms did not differ significantly in any scoring category (reader 1: P = .50, .39, and .39; reader 2: P = .41, .61, and .33, respectively). CT scores were substantially better in 20% (four of 20) and 25% (five of 20) of the pooled evaluations for the visualization of disease and overall image quality categories, respectively, versus 5% (one of 20) for MR scores in both categories. CONCLUSION: Three-station bolus-chase MR angiography with real-time fluoroscopic tracking provided high-spatial-resolution arteriograms of the peripheral vasculature, enabled precise triggering of table motion, and compared well with CT angiograms.


Assuntos
Abdome/irrigação sanguínea , Meios de Contraste , Imageamento Tridimensional , Perna (Membro)/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Doenças Vasculares Periféricas/diagnóstico , Adulto , Idoso , Estudos de Viabilidade , Feminino , Fluoroscopia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Compostos Organometálicos , Doenças Vasculares Periféricas/diagnóstico por imagem , Tomografia Computadorizada por Raios X
9.
Abdom Imaging ; 39(6): 1309-22, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24811765

RESUMO

Balanced steady state-free precession (b-SSFP) pulse sequences have a number of properties which can be useful in magnetic resonance cholangiopancreatography (MRCP), including short acquisition times, high signal-to-noise ratios, and T2/T1 contrast weighting. The utility and versatility of b-SSFP sequences for MRCP imaging are probably underappreciated, and this pictorial essay briefly discusses benefits and limitations of 2D and 3D b-SSFP techniques used in place of or in addition to conventional single-shot fast spin echo or 3D fast spin echo acquisitions and illustrates their appearance in several clinical cases.


Assuntos
Doenças Biliares/diagnóstico , Sistema Biliar/patologia , Colangiopancreatografia por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
10.
Lab Invest ; 93(6): 733-43, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23588707

RESUMO

The cholangiopathies are a diverse group of biliary tract disorders, many of which lack effective treatment. Murine models are an important tool for studying their pathogenesis, but existing noninvasive methods for assessing biliary disease in vivo are not optimal. Here we report our experience with using micro-computed tomography (microCT) and nuclear magnetic resonance (MR) imaging to develop a technique for live-mouse cholangiography. Using mdr2 knockout (mdr2KO, a model for primary sclerosing cholangitis (PSC)), bile duct-ligated (BDL), and normal mice, we performed in vivo: (1) microCT on a Siemens Inveon PET/CT scanner and (2) MR on a Bruker Avance 16.4 T spectrometer, using Turbo Rapid Acquisition with Relaxation Enhancement, IntraGate Fast Low Angle Shot, and Half-Fourier Acquisition Single-shot Turbo Spin Echo methods. Anesthesia was with 1.5-2.5% isoflurane. Scans were performed with and without contrast agents (iodipamide meglumine (microCT), gadoxetate disodium (MR)). Dissection and liver histology were performed for validation. With microCT, only the gallbladder and extrahepatic bile ducts were visualized despite attempts to optimize timing, route, and dose of contrast. With MR, the gallbladder, extra-, and intrahepatic bile ducts were well-visualized in mdr2KO mice; the cholangiographic appearance was similar to that of PSC (eg, multifocal strictures) and could be improved with contrast administration. In BDL mice, MR revealed cholangiographically distinct progressive dilation of the biliary tree without ductal irregularity. In normal mice, MR allowed visualization of the gallbladder and extrahepatic ducts, but only marginal visualization of the diminutive intrahepatic ducts. One mouse died during microCT and MR imaging, respectively. Both microCT and MR scans could be obtained in ≤20 min. We, therefore, demonstrate that MR cholangiography can be a useful tool for longitudinal studies of the biliary tree in live mice, whereas microCT yields suboptimal duct visualization despite requiring contrast administration. These findings support further development and application of MR cholangiography to the study of mouse models of PSC and other cholangiopathies.


Assuntos
Doenças dos Ductos Biliares/diagnóstico por imagem , Colangiografia , Animais , Meios de Contraste , Modelos Animais de Doenças , Feminino , Gadolínio DTPA , Imageamento por Ressonância Magnética , Masculino , Camundongos , Microtomografia por Raio-X
11.
Radiology ; 268(3): 770-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23788716

RESUMO

PURPOSE: To test the hypothesis that fractional kidney hypoxia, measured by using blood oxygen level-dependent (BOLD) magnetic resonance (MR) imaging, correlates with renal blood flow (RBF), tissue perfusion, and glomerular filtration rate (GFR) in patients with atherosclerotic renal artery stenosis (RAS) better than regionally selected region of interest-based methods. MATERIALS AND METHODS: The study was approved by the institutional review board according to a HIPAA-compliant protocol, with written informed consent. BOLD MR imaging was performed in 40 patients with atherosclerotic RAS (age range, 51-83 years; 22 men, 18 women) and 32 patients with essential hypertension (EH) (age range, 26-85 years; 19 men, 13 women) during sodium intake and renin-angiotensin blockade. Fractional kidney hypoxia (percentage of entire axial image section with R2* above 30 sec(-1)) and conventional regional estimates of cortical and medullary R2* levels were measured. Stenotic and nonstenotic contralateral kidneys were compared for volume, tissue perfusion, and blood flow measured with multidetector computed tomography. Statistical analysis was performed (paired and nonpaired t tests, linear regression analysis). RESULTS: Stenotic RBF was reduced compared with RBF of contralateral kidneys (225.2 mL/min vs 348 mL/min, P = .0003). Medullary perfusion in atherosclerotic RAS patients was lower than in EH patients (1.07 mL/min per milliliter of tissue vs 1.3 mL/min per milliliter of tissue, P = .009). While observer-selected cortical R2* (18.9 sec(-1) [stenosis] vs 18.5 sec(-1) [EH], P = .07) did not differ, fractional kidney hypoxia was higher in stenotic kidneys compared with kidneys with EH (17.4% vs 9.6%, P < .0001) and contralateral kidneys (7.2%, P < .0001). Fractional hypoxia correlated inversely with blood flow (r = -0.34), perfusion (r = -0.3), and GFR (r = -0.32). CONCLUSION: Fractional tissue hypoxia rather than cortical or medullary R2* values used to assess renal BOLD MR imaging demonstrated a direct relationship to chronically reduced blood flow and GFR.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Oximetria/métodos , Oxigênio/sangue , Obstrução da Artéria Renal/sangue , Obstrução da Artéria Renal/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Hipóxia Celular , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Magn Reson Med ; 70(2): 348-57, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22936574

RESUMO

Time-resolved three-dimensional contrast-enhanced MR angiography often relies on view sharing of peripheral k-space data to enable acquisition of angiograms with both high spatial resolution and a rapid frame rate. It is typically assumed that k-space will be fully sampled during passage of the contrast bolus arterial phase. However, this is not the case when view sharing is incomplete, for example, at the leading edge of an enhancing vessel or if acquisition time is limited as in fluoroscopic tracking for multistation bolus chase MR angiography. Incomplete view sharing will degrade image quality, for example, by reducing vessel signal and sharpness and increasing undersampling artifacts. In this work, the evolution of angiogram quality with view sharing is quantitatively assessed in phantom experiments and in vivo contrast-enhanced MR angiography calf studies. It is demonstrated that there are multiple sets of sequence parameters that can yield a target image update time, but the choice of parameters can profoundly affect how image quality evolves with view sharing. A fundamental tradeoff between vessel signal and sharpness and its relationship to the sequence temporal footprint is investigated and discussed.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
J Vasc Interv Radiol ; 24(3): 392-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23433414

RESUMO

PURPOSE: To compare prospectively the assessment of stenosis and radiologist confidence in the evaluation of below-the-knee lower extremity runoff vessels between computed tomography (CT) angiography and contrast-enhanced magnetic resonance (MR) angiography in a cohort of 19 clinical patients. MATERIALS AND METHODS: The study was compliant with the Health Insurance Portability and Accountability Act of 1996 and approved by the institutional review board. Imaging was performed in 19 consecutive patients with known or suspected peripheral arterial disease; both CT angiography and a more recently developed MR angiography technique were performed within 24 hours of each other and before any therapeutic intervention. Resulting images were randomized and interpreted in blinded fashion by four board-certified radiologists with expertise in CT angiography and MR angiography. Vasculature of the lower leg was apportioned into 22 segments, 11 for each leg. For each segment, degree of stenosis and confidence of diagnosis were determined using a 3-point scale. Differences between CT angiography and MR angiography were assessed for significance using pooled histograms that were analyzed using the Wilcoxon signed rank test. RESULTS: For assessment of stenosis, there was no difference in CT angiography compared with MR angiography for 20 of 22 segments. For confidence of diagnosis, assessment of popliteal arteries was superior on CT angiography compared with MR angiography (P<.05). Confidence in assessment of both tibioperoneal trunks and the left proximal anterior tibial artery was not significantly different between CT angiography and MR angiography. Confidence in assessment of all other 17 segments was superior with MR angiography compared with CT angiography (P<.02). CONCLUSIONS: MR angiography using the method described here is a promising technique for evaluating lower extremity arterial runoff. MR angiography had an overall superior performance in radiologist confidence compared with CT angiography for imaging runoff vessels below the knee.


Assuntos
Extremidade Inferior/irrigação sanguínea , Angiografia por Ressonância Magnética , Doença Arterial Periférica/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Constrição Patológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
14.
J Clin Med ; 12(8)2023 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-37109291

RESUMO

Renal fibrosis is an important marker in the progression of chronic kidney disease, and renal biopsy is the current reference standard for detecting its presence. Currently, non-invasive methods have only been partially successful in detecting renal fibrosis. Magnetization transfer imaging (MTI) allows estimates of renal fibrosis but may vary with scanning conditions. We hypothesized that MTI-derived renal fibrosis would be reproducible at 1.5T and 3T MRI and over time in fibrotic kidneys. Fifteen pigs with unilateral renal artery stenosis (RAS, n = 9) or age-matched sham controls (n = 6) underwent MTI-MRI at both 1.5T and 3T 6 weeks post-surgery and again 4 weeks later. Magnetization transfer ratio (MTR) measurements of fibrosis in both kidneys were compared between 1.5T and 3T, and the reproducibility of MTI at the two timepoints was evaluated at 1.5T and 3T. MTR at 3T with 600 Hz offset frequency successfully distinguished between normal, stenotic, and contralateral kidneys. There was excellent reproducibility of MTI at 1.5T and 3T over the two timepoints and no significant differences between MTR measurements at 1.5T and 3T. Therefore, MTI is a highly reproducible technique which is sensitive to detect changes in fibrotic compared to normal kidneys in the RAS porcine model at 3T.

15.
J Magn Reson Imaging ; 36(5): 1168-78, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22753021

RESUMO

PURPOSE: To refine, adapt, and evaluate the technical aspects of fluoroscopic tracking for generating dual-station high-spatial-resolution MR angiograms of the calves and feet using a single injection of contrast material. MATERIALS AND METHODS: Nine subjects (seven healthy volunteers followed by two patients) were imaged using a two-station calf-foot three-dimensional time-resolved bolus chase MR angiography protocol which provided <1.0 mm(3) spatial resolution throughout and 2.5- and 6.6-s frame times at the calf and foot stations, respectively. Real-time reconstruction of calf station time frames allowed visually guided triggering of table advance to the foot station. The studies were independently read and scored by two radiologists in six image quality categories. RESULTS: On average, overall diagnostic quality at the calf and foot stations was good-to-excellent, the calf arteries and all but the smallest foot arteries had good-to-excellent signal and sharpness, artifact and venous contamination were minor, and signal continuity across the inter-station interface was good. CONCLUSION: The feasibility of fluoroscopic tracking has been demonstrated as an efficient approach for high spatiotemporal imaging of the arteries of the calves and feet with good-to-excellent diagnostic quality and low degrading venous contamination.


Assuntos
Algoritmos , Artérias/anatomia & histologia , Imageamento Tridimensional/métodos , Perna (Membro)/anatomia & histologia , Perna (Membro)/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Nephrol Dial Transplant ; 27(9): 3532-9, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22773240

RESUMO

BACKGROUND: We showed in a randomized double-blinded placebo-controlled clinical trial that octreotide long-acting repeatable depot.® (OctLAR(®)) for 12 months reduces kidney and liver growth in autosomal dominant polycystic kidney patients with severe polycystic liver disease (PLD) and liver growth in patients with severe isolated PLD. We have now completed an open-label extension for one additional year to assess safety and clinical benefits of continued use of OctLAR for 2 years (O → O) and examined drug effect in the placebo group who crossed over to OctLAR in Year 2 (P → O). METHODS: The primary end point was change in total liver volume (TLV) measured by magnetic resonance imaging (MRI); secondary end points were changes in total kidney volume (TKV) measured by MRI, glomerular filtration rate (GFR), quality of life (QOL), safety, vital signs and laboratory parameters. RESULTS: Forty-one of 42 patients received OctLAR (n = 28) or placebo (n = 14) in Year 1 and received OctLAR in Year 2 (maximum dose 40 mg). Patients originally randomized to placebo (P → O) showed substantial reduction in TLV after treatment with OctLAR in Year 2 (Δ% -7.66 ± 9.69%, P = 0.011). The initial reduction of TLV in the OctLAR group (O → O) was maintained for 2 years (Δ% -5.96 ± 8.90%), although did not change significantly during Year 2 (Δ% -0.77 ± 6.82%). OctLAR inhibited renal enlargement during Year 1 (Δ% +0.42 ± 7.61%) in the (O → O) group and during Year 2 (Δ% -0.41 ± 9.45%) in the (P → O) group, but not throughout Year 2 (Δ% +6.49 ± 7.08%) in the (O → O) group. Using pooled analyses of all individuals who received OctLAR for 12 months, i.e. in Year 1 for O → O patients and Year 2 for P → O patients, average reduction in TLV was -6.08 ± 7.58% (P = 0.001) compared to net growth of 0.9 ± 8.35% in the original placebo group. OctLAR-treated individuals continued to experience improvements in QOL in Year 2, although overall physical and mental improvements were not significant during Year 2 compared to Year 1. Changes in GFR were similar in both groups. CONCLUSION: Over 2 years, OctLAR significantly reduced the rate of increase in TLV and possibly the rate of increase in TKV.


Assuntos
Cistos/tratamento farmacológico , Hormônios/uso terapêutico , Nefropatias/etiologia , Hepatopatias/tratamento farmacológico , Somatostatina/uso terapêutico , Adolescente , Estudos Cross-Over , Cistos/complicações , Método Duplo-Cego , Feminino , Seguimentos , Taxa de Filtração Glomerular , Humanos , Nefropatias/patologia , Hepatopatias/complicações , Imageamento por Ressonância Magnética , Masculino , Prognóstico , Qualidade de Vida , Fatores de Risco , Somatostatina/análogos & derivados , Fatores de Tempo
17.
Invest Radiol ; 57(5): 334-342, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-34935650

RESUMO

OBJECTIVES: Quantitative magnetization transfer (qMT) is useful for measurement of murine renal fibrosis at high and ultrahigh field strengths. However, its utility at clinical field strengths and in human-like kidneys remains unknown. We tested the hypothesis that qMT would successfully detect fibrosis in swine kidneys with unilateral renal artery stenosis (RAS) at 3.0 T. METHODS: The qMT protocol is composed of MT scans with variable flip angles and offset frequencies, and of B0, B1, and T1 mapping. Pigs were scanned 10 weeks after RAS or control. A 2-pool model was used to fit the bound pool fraction f of the renal cortex (CO) and outer medulla (OM). Then qMT-derived f in 5 normal and 10 RAS pigs was compared with histological fibrosis determined using Masson's trichrome staining and to renal perfusion assessed with computed tomography. RESULTS: The qMT 2-pool model provided accurate fittings of data collected on swine kidneys. Stenotic kidneys showed significantly elevated f in both the CO (9.8% ± 2.7% vs 6.4% ± 0.9%, P = 0.002) and OM (7.6% ± 2.2% vs 4.7% ± 1.1%, P = 0.002), as compared with normal kidneys. Histology-measured renal fibrosis and qMT-derived f correlated directly in both the cortex (Pearson correlation coefficient r = 0.93, P < 0.001) and OM (r = 0.84, P = 0.002), and inversely with stenotic kidney perfusion (r = 0.85, P = 0.002). CONCLUSIONS: This study demonstrates the feasibility of qMT for measuring fibrosis in human-like swine kidneys, and the association between tissue macromolecule content and renal perfusion. Therefore, qMT may be useful as a tool for noninvasive assessment of renal fibrosis in subjects with RAS at clinical field strengths.


Assuntos
Imageamento por Ressonância Magnética , Obstrução da Artéria Renal , Animais , Fibrose , Humanos , Rim/diagnóstico por imagem , Rim/patologia , Imageamento por Ressonância Magnética/métodos , Camundongos , Obstrução da Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/patologia , Suínos
18.
Radiology ; 261(2): 587-97, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21900616

RESUMO

PURPOSE: To demonstrate that highly accelerated (net acceleration factor [R(net)] ≥ 10) acquisition techniques can be used to generate three-dimensional (3D) subsecond timing images, as well as diagnostic-quality high-spatial-resolution contrast material-enhanced (CE) renal magnetic resonance (MR) angiograms with a single split dose of contrast material. MATERIALS AND METHODS: All studies were approved by the institutional review board and were HIPAA compliant; written consent was obtained from all participants. Twenty-two studies were performed in 10 female volunteers (average age, 47 years; range, 27-62 years) and six patients with renovascular disease (three women; average age, 48 years; range, 37-68 years; three men; average age, 60 years; range, 50-67 years; composite average age, 54 years; range, 38-68 years). The two-part protocol consisted of a low-dose (2 mL contrast material) 3D timing image with approximate 1-second frame time, followed by a high-spatial-resolution (1.0-1.6-mm isotropic voxels) breath-hold 3D renal MR angiogram (18 mL) over the full abdominal field of view. Both acquisitions used two-dimensional (2D) sensitivity encoding acceleration factor (R) of eight and 2D homodyne (HD) acceleration (R(HD)) of 1.4-1.8 for R(net) = R · R(HD) of 10 or higher. Statistical analysis included determination of mean values and standard deviations of image quality scores performed by two experienced reviewers with use of eight evaluation criteria. RESULTS: The 2-mL 3D time-resolved image successfully portrayed progressive arterial filling in all 22 studies and provided an anatomic overview of the vasculature. Successful timing was also demonstrated in that the renal MR angiogram showed adequate or excellent portrayal of the main renal arteries in 21 of 22 studies. CONCLUSION: Two-dimensional acceleration techniques with R(net) of 10 or higher can be used in CE MR angiography to acquire (a) a 3D image series with 1-second frame time, allowing accurate bolus timing, and (b) a high-spatial-resolution renal angiogram. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11110242/-/DC1.


Assuntos
Meios de Contraste , Aumento da Imagem/métodos , Nefropatias/diagnóstico , Angiografia por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos , Adulto , Idoso , Estudos de Casos e Controles , Meios de Contraste/administração & dosagem , Feminino , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/instrumentação , Masculino , Meglumina/administração & dosagem , Pessoa de Meia-Idade , Compostos Organometálicos/administração & dosagem , Circulação Renal
19.
Magn Reson Med ; 66(4): 1019-32, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21608028

RESUMO

Cartesian Acquisition with Projection-Reconstruction-like sampling is a SENSE-type parallel 3DFT acquisition paradigm for 4D contrast-enhanced magnetic resonance angiography that has been demonstrated capable of providing high spatial and temporal resolution, diagnostic-quality images at very high acceleration rates. However, Cartesian Acquisition with Projection-Reconstruction-like sampling images are typically reconstructed online using Tikhonov regularization and partial Fourier methods, which are prone to exhibit noise amplification and undersampling artifacts when operating at very high acceleration rates. In this work, a sparsity-driven offline reconstruction framework for Cartesian Acquisition with Projection-Reconstruction-like sampling is developed and demonstrated to consistently provide improvements over the currently-employed reconstruction strategy against these ill-effects. Moreover, the proposed reconstruction strategy requires no changes to the existing Cartesian Acquisition with Projection-Reconstruction-like sampling acquisition protocol, and an efficient numerical optimization and hardware system are described that allow for a 256 × 160 × 80 volume contrast-enhanced magnetic resonance angiography volume to be reconstructed from an eight-channel data set in less than 2 min.


Assuntos
Circulação Cerebrovascular , Pé/irrigação sanguínea , Mãos/irrigação sanguínea , Angiografia por Ressonância Magnética/métodos , Algoritmos , Artefatos , Criança , Meios de Contraste , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Meglumina/análogos & derivados , Compostos Organometálicos
20.
J Magn Reson Imaging ; 33(6): 1406-13, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21591010

RESUMO

PURPOSE: To compare a noncontrast enhanced balanced steady state free precession (bSSFP) MRI technique with a conventional dynamic contrast-enhanced (DCE) three-dimensional (3D) spoiled gradient recalled echo (SPGR) imaging in the vascular staging of renal and adrenal malignancies. MATERIALS AND METHODS: Sixty-three MRIs with both bSSFP and DCE acquisitions performed for initial staging of renal and adrenal malignancies were retrospectively evaluated for presence and extent of thrombus in the renal veins and inferior vena cava (IVC). Thrombus characterization was also evaluated. DCE imaging was used as the standard-of-reference. Histopathology was available in 46 of 63 cases as an additional external standard. RESULTS: There is very good agreement between bSSFP and DCE imaging for determining the presence or absence of thrombus in the renal veins (r = 0.95; P < 0.0001) and IVC (r = 0.91; P < 0.0001). BSSFP is less successful at distinguishing bland from tumor thrombus. CONCLUSION: Noncontrast enhanced bSSFP is an acceptable alternative to DCE imaging for vascular staging of locally advanced renal/adrenal malignancies, with somewhat limited ability to distinguish bland from tumor thrombus.


Assuntos
Neoplasias das Glândulas Suprarrenais/patologia , Carcinoma de Células Renais/patologia , Meios de Contraste/farmacologia , Neoplasias Renais/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias/métodos , Veias Renais/patologia , Estudos Retrospectivos , Trombose/patologia , Veia Cava Inferior/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA