Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Radiology ; 312(2): e240229, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-39136569

RESUMO

Background Quantifying the fibrotic and calcific composition of the aortic valve at CT angiography (CTA) can be useful for assessing disease severity and outcomes of patients with aortic stenosis (AS); however, it has not yet been validated against quantitative histologic findings. Purpose To compare quantification of aortic valve fibrotic and calcific tissue composition at CTA versus histologic examination. Materials and Methods This prospective study included patients who underwent CTA before either surgical aortic valve replacement for AS or orthotopic heart transplant (controls) at two centers between January 2022 and April 2023. At CTA, fibrotic and calcific tissue composition were quantified using automated Gaussian mixture modeling applied to the density of aortic valve tissue components, calculated as [(volume/total tissue volume) × 100]. For histologic evaluation, explanted valve cusps were stained with Movat pentachrome as well as hematoxylin and eosin. For each cusp, three 5-µm slices were obtained. Fibrotic and calcific tissue composition were quantified using a validated artificial intelligence tool and averaged across the aortic valve. Correlations were assessed using the Spearman rank correlation coefficient. Intermodality and interobserver variability were measured using the intraclass correlation coefficient (ICC) and Bland-Altman plots. Results Twenty-nine participants (mean age, 63 years ± 10 [SD]; 23 male) were evaluated: 19 with severe AS, five with moderate AS, and five controls. Fibrocalcific tissue composition strongly correlated with histologic findings (r = 0.92; P < .001). The agreement between CTA and histologic findings for fibrocalcific tissue quantification was excellent (ICC, 0.94; P = .001), with underestimation of fibrotic composition at CTA (bias, -4.9%; 95% limits of agreement [LoA]: -18.5%, 8.7%). Finally, there was excellent interobserver repeatability for fibrotic (ICC, 0.99) and calcific (ICC, 0.99) aortic valve tissue volume measurements, with no evidence of a difference in measurements between readers (bias, -0.04 cm3 [95% LoA: -0.27 cm3, 0.19 cm3] and 0.02 cm3 [95% LoA: -0.14 cm3, 0.19 cm3], respectively). Conclusion In a direct comparison, standardized quantitative aortic valve tissue characterization at CTA showed excellent concordance with histologic findings and demonstrated interobserver reproducibility. Clinical trial registration no. NCT06136689 Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Almeida in this issue.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Calcinose , Angiografia por Tomografia Computadorizada , Fibrose , Humanos , Masculino , Estudos Prospectivos , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Pessoa de Meia-Idade , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/patologia , Estenose da Valva Aórtica/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Fibrose/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Idoso
2.
J Card Surg ; 37(3): 526-531, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34821415

RESUMO

BACKGROUND: The incompetent bicuspid aortic valve (BAV) can be repaired using various techniques. This study presents a prospective comparison of external and subcommissural aortic annuloplasty. METHODS: Fifty consecutive patients (38 males, age: 43.9 ± 15.8 years) with BAV insufficiency with or without aortic dilatation underwent valve repair in a single institution. They were prospectively allocated to one of two groups based on the aortic annulus stabilization technique: 25 patients were operated on using the subcommissural annuloplasty (SCA) and 25 using the external complete annuloplasty (EA). Transthoracic echocardiography was performed in all patients before the operation and 1 and 3 years after the operation. Moreover, mortality and morbidity at 7 years were evaluated. RESULTS: In prospective echocardiographic comparison, EA was associated with smaller diameter of the aortic annulus (24.1 ± 2.6 mm vs. 25.8±2.1 mm, p < .05) and lower mean and peak transvalvular gradients (7 ± 4 mmHg vs. 13 ± 4 mmHg, p = .02 and 15.3 ± 9.7 mmHg vs. 20.7 ± 5.6 mmHg, p = .03, respectively). No patients died or required reoperation due to recurrent insufficiency at 6,81 (interquartile range-0,17) years after the operation. The Kaplan-Meier actuarial freedom from aortic regurgitation (AR) grade =2 or gradient > 20 mmHg at 35.1 ± 3.6 months years was 96% (24 out of 25) for patients who had external annuloplasty and amounted to 76% (19 out of 25) for those who had SCA, p = .05). CONCLUSIONS: External annuloplasty performed during repair of the BAV is associated with better hemodynamics at medium-term follow-up compared to SCA.


Assuntos
Insuficiência da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Anuloplastia da Valva Cardíaca , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
3.
BMC Cardiovasc Disord ; 21(1): 13, 2021 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-33407164

RESUMO

BACKGROUND: The incompetent bicuspid aortic valve (BAV) can be replaced or repaired using various surgical techniques. This study sought to assess the efficacy of external annuloplasty and postoperative reverse remodelling using cardiac magnetic resonance (CMR) and compare the results of external and subcommissural annuloplasty. METHODS: Out of a total of 200 BAV repair performed between 2004 and 2018, 21 consecutive patients (median age 54 years) with regurgitation requiring valve repair with annuloplasty without concomitant aortic root surgery were prospectively referred for CMR and transthoracic echocardiography (TTE) one year after the operation. Two aortic annulus stabilization techniques were used: external, circumferential annuloplasty (EA), and subcommissural annuloplasty (SCA). RESULTS: 11 patients received EA and 10 patients were treated using SCA. There was no in-hospital mortality and all patients survived the follow-up period (median: 12.6 months (first quartile: 6.6; third quartile: 14.1). CMR showed strong correlation between postoperative aortic recurrent regurgitant fraction and left ventricular end-diastolic volume (r = 0.62; p = 0.003) as well as left ventricular ejection fraction (r = -0.53; p = 0.01). Patients treated with EA as compared with SCA had larger anatomic aortic valve area measured by CMR (3.5 (2.5; 4.0) vs. 2.5 cm2 (2.0; 3.4); p = 0.04). In both EA and SCA group, aortic valve area below 3.5 cm2 correlated with no regurgitation recurrency. EA (vs. SCA) was associated with lower peak transvalvular aortic gradients (10 (6; 17) vs. 21 mmHg (15; 27); p = 0.04). CONCLUSIONS: The repair of the bicuspid aortic valve provides significant postoperative reverse remodelling, provided no recurrent regurgitation and durable reduction annuloplasty can be achieved. EA is associated with lower transvalvular gradients and higher aortic valve area assessed by CMR, compared to SCA.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Anuloplastia da Valva Cardíaca , Imagem Cinética por Ressonância Magnética , Adulto , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Anuloplastia da Valva Cardíaca/efeitos adversos , Ecocardiografia , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
5.
J Heart Valve Dis ; 23(4): 414-23, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25803967

RESUMO

BACKGROUND AND AIM OF THE STUDY: The advantages of aortic valve repair and root reconstruction include the maintenance of natural valve hemodynamics and an avoidance of prosthetic valve-related complications. However, the general acceptance of valve reconstruction currently may be limited by a paucity of long-term follow up data from only a few centers. The study aim was to supplement existing outcome information for aortic valve repair. METHODS: Between 2003 and 2012, a total of 150 consecutive patients (119 males, 31 females; mean age 51.1 years) with significant aortic regurgitation and aortic root enlargement underwent aortic valve repair and associated root reconstruction. The same prospective selection criteria and systematic valve repair approaches were followed throughout the study. Root management consisted of either root remodeling or reimplantation with Dacron prostheses. Kaplan-Meier techniques were used to assess major end-points of all-cause mortality, reoperation, and repair failure. Univariable log-rank testing identified any associations between risk factors and major events. RESULTS: The early mortality rate was 2.7% (n = 4), and early repair failure rate 3.3% (n = 5). At a mean follow up of 43.6 months (1st, 3rd percentile, 17.8, 78.0 months), the survival rate was 93% and freedom from reoperation 91%. Univariable risk factors for mortality included advanced preoperative NYHA class and a requirement for root replacement. Repair failure and reoperation were associated with bicuspid valve anatomy, subcommissural annuloplasty, leaflet resection with pericardial patching, and Gore-Tex leaflet reinforcement. CONCLUSION: The present data, acquired from a prospective cohort of patients undergoing aortic valve repair and root reconstruction, reinforced the satisfactory late results obtained with valve reconstruction. These findings also support a broader application of aortic valve repair in future patients.


Assuntos
Aorta/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Aorta/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Implante de Prótese Vascular , Anuloplastia da Valva Cardíaca , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Polietilenotereftalatos , Estudos Prospectivos , Reoperação , Fatores de Risco , Resultado do Tratamento , Ultrassonografia
6.
Perioper Med (Lond) ; 13(1): 54, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38858770

RESUMO

BACKGROUND: Due to the distinctive nature of cardiac surgery, patients suffering from hereditary spherocytosis (HS) are potentially at a high risk of perioperative complications resulting from hemolysis. Despite being the most prevalent cause of hereditary chronic hemolysis, the standards of surgical management are based solely on expert opinion. OBJECTIVE: We analyze the risk of hemolysis in HS patients after cardiac surgery based on a systematic review of the literature. We also describe a case of a patient with hereditary spherocytosis who underwent aortic valve repair. METHODS: This systematic review was registered in the PROSPERO international prospective register of systematic reviews (CRD42023417666) and included records from Embase, MEDLINE, Web of Science, and Google Scholar databases. The case study investigates a 38-year-old patient who underwent surgery for an aortic valve defect in mid-2022. RESULTS: Of the 787 search results, 21 studies describing 23 cases of HS undergoing cardiac surgery were included in the final analysis. Hemolysis was diagnosed in five patients (one coronary artery bypass graft surgery, two aortic valve bioprosthesis, one ventricular septal defect closure, and one mitral valve plasty). None of the patients died in the perioperative period. Also, no significant clinical hemolysis was observed in our patient during the perioperative period. CONCLUSIONS: The literature data show that hemolysis is not common in patients with HS undergoing various cardiac surgery techniques. The typical management of a patient with mild/moderate HS does not appear to increase the risk of significant clinical hemolysis. Commonly accepted beliefs about factors inducing hemolysis during cardiac surgery may not be fully justified and require further investigation.

7.
Postepy Kardiol Interwencyjnej ; 20(1): 76-83, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38616934

RESUMO

Introduction: Aortic stenosis is the most common primary valve disease and requires invasive treatment. Transcatheter aortic valve implantation (TAVI) from a transfemoral access is a routine intervention worldwide. Aim: To investigate the correlation between external iliac artery diameter (EIAD) indexed to body surface area (BSA) (EIAD-BSA) and access site complications in patients undergoing TAVI via transfemoral access (TF) (TF-TAVI). Material and methods: Patients underwent TF-TAVI in 2017-2019 at the Upper-Silesian Medical Center in Katowice. Based on the preoperative multi-slice computed tomography (MSCT), pre-specified measurements of the ilio-femoral vessels were performed. The results were indexed to BSA and body mass index (BMI). Complications after TAVI were defined by Valve Academic Research Consortium 3 (VARC-3). The primary outcome regarding the adverse events after TAVI was the composite of access site complications requiring surgical intervention or blood transfusion. Results: The registry included 193 unselected patients with severe symptomatic aortic stenosis. Vascular and access-related complications including bleeding occurred in 17.1% of patients. Major TAVI access site complications (VARC-3) were reported in 5.7% of patients, while minor complications (VARC-3) occurred in 2.6%. EIAD-BSA demonstrated a positive correlation with the access site complications primary endpoint. Patients with greater EIAD-BSA had a numerically higher number of access site adverse events requiring surgical intervention or blood transfusion: n = 12 (5%) vs. n = 4 (4%), p = 0.011. Conclusions: External iliac artery diameter indexed to BSA could be an underestimated indicator of unfavorable outcomes after TF-TAVI, predicting periprocedural access site complications.

8.
J Clin Med ; 13(9)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38731222

RESUMO

Background: Aortic valve-sparing aortic root replacement (VSARR) David procedure has not been routinely performed via minimally invasive access due to its complexity. Methods: We compared our results for mini-VSARR to sternotomy-VSARR from another excellence center. Results: Eighty-four patients, 62 in the sternotomy-VSARR group and 22 in the mini-VSARR group, were included. A baseline, the aneurysm dimensions were higher in the mini-VSARR group. Propensity matching resulted in 17 pairs with comparable characteristics. Aortic cross-clamp and cardiopulmonary bypass times were significantly longer in the mini-VSARR group, by 60 and 20 min, respectively (p < 0.001). In-hospital outcomes were comparable between the groups. Drainage volumes were numerically lower, and hospital length of stay was, on average, 3 days shorter (p < 0.001) in the mini-VSARR group. At a median follow-up of 5.5 years, there was no difference in mortality (p = 0.230). Survival at 1, 5 and 10 years was 100%, 100%, and 95% and 95%, 87% and 84% in the mini-VSARR and sternotomy-VSARR groups, respectively. No repeat interventions on the aortic valve were documented. Echocardiographic follow-up was complete in 91% with excellent durability of repair regardless of the approach: no cases of moderate/severe aortic regurgitation were reported in the mini-VSARR group. Conclusions: The favorable outcomes, reduced drainage, and shorter hospital stays associated with the mini-sternotomy approach underscore its potential advantages expanding beyond cosmetic outcome.

9.
Cardiol J ; 30(2): 188-195, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34308536

RESUMO

BACKGROUND: The purpose of this study was to compare the safety and clinical outcomes of transcarotid (TC) and transapical access (TA) transcatheter aortic valve implantation (TAVI) patients whom the transfemoral approach (TF) was not feasible. METHODS: The analysis included consecutive patients with severe symptomatic aortic stenosis treated from 2017 to 2020 with TC-TAVI or TA-TAVI in two high-volume TAVI centers. The approach was selected by multidisciplinary heart teams after analyzing multislice computed tomography of the heart, aorta and peripheral arteries, transthoracic echocardiography and coronary angiography. RESULTS: One hundred and two patients were treated with alternative TAVI accesses (TC; n = 49 and TA; n = 53) in our centers. The groups were similar regarding age, gender, New York Heart Association class, and echocardiography parameters. Patients treated with TC-TAVI had significantly higher surgical risk. The procedural success rate was similar in both groups (TC-TAVI 98%; TA-TAVI 98.1%; p = 0.95). The rate of Valve Academic Research Consortium-2 defined clinical events was low in both groups. The percentage of new-onset rhythm disturbances and permanent pacemaker implantation was similar in TC and TA TAVI (4.1% vs. 11.3%; p = 0.17 and 10.2% vs. 5.7%; p = 0.39, respectively). In the TA-TAVI group, significantly more cases of pneumonia and blood transfusions were observed (11% vs. 0%; p = 0.01 and 30.2% vs. 12.2%; p = 0.03). The 30-day mortality was similar in TC and TA groups (4.1% vs. 5.7%; p = 0.71, respectively). CONCLUSIONS: Both TC and TA TAVI are safe procedures in appropriately selected patients and are associated with a low risk of complications.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia , Contraindicações , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos
10.
Kardiol Pol ; 80(4): 436-444, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35152397

RESUMO

BACKGROUND: The treatment of aortic root aneurysm remains challenging for both cardiac surgeons and cardiologists. AIMS: This study aimed to assess and compare the long-term outcomes of different approaches to aortic root replacement (ARR). METHODS: All elective patients operated for aortic root aneurysm with or without aortic regurgitation at our institution over a 10-year period were included. We excluded patients with any degree of aortic stenosis and with active endocarditis. We assessed mortality, freedom from reoperation, freedom from aortic valve regurgitation, and the rate of hemorrhagic and thromboembolic complications. RESULTS: Two hundred and four patients underwent elective aortic root replacement: 107 (53%) valve-sparing aortic root replacement (VSARR), 35 (17%) mechanical Bentall procedure (MB), and 62 (30%) Bio-Bentall procedure (BB). Early mortality for VSARR, BB, and MB group was 2.8%, 4.8%, and 0%, respectively (P = 0.40). Estimated 5-year survival was: 90.2% vs. 78.4% vs. 94.2%, respectively (P = 0.12), 5-year freedom from reoperation: 97.8%, 96.6%, and 96.8%, respectively (P = 0.99). Estimat-ed 5-year freedom from complications was: 94.2%, 83.1% and 57.3% in the VSARR, BB and MB group, respectively (P <0.001). On last follow-up echocardiography, 90.5%, 98.4%, and 97.1% (P = 0.08) of patients were free from aortic regurgitation grade 2 or higher. The median (IQR) aortic valve peak gradient was 9 (6-12) mm Hg, 12 (10-18) mm Hg and 16 (14-22) mm Hg, respectively (P <0.001). Complications were predicted by mechanical Bentall (hazard ratio, 6.70 [2.54-17.63]; P <0.001). CONCLUSION: With the same mortality, freedom from reoperation, and a minimal late complication rate in comparison with mechanical Bentall and Bio-Bentall, VSARR might be the preferred approach to aortic root aneurysm.


Assuntos
Aneurisma da Aorta Torácica , Insuficiência da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Aneurisma da Aorta Torácica/cirurgia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
11.
Artigo em Inglês | MEDLINE | ID: mdl-36424214

RESUMO

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) remains the preferred strategy for high-risk or elderly individuals with aortic valve (AV) stenosis who are not considered to be optimal surgical candidates. Recent evidence suggests that low-risk patients may benefit from TAVI as well. The current study evaluates midterm survival in low-risk patients undergoing elective surgical AV replacement (SAVR) versus TAVI. METHODS: The Aortic Valve Replacement in Elective Patients From the Aortic Valve Multicenter Registry (AVALON) compared isolated elective transfemoral TAVI or SAVR with sternotomy or minimally invasive approach in low-risk individuals performed between 2015 and 2019. Propensity score matching was conducted to determine SAVR controls for TAVI group in a 1-to-3 ratio with 0.2 caliper. RESULTS: A total of 2393 patients undergoing elective surgery (1765 SAVR and 629 TAVI) with median European System for Cardiac Operative Risk Evaluation II (EuroSCORE II) score 1.81 (interquartile range [IQR], 1.36 to 2.53]) were initially included. Median follow-up was 2.72 years (IQR, 1.32-4.08; max 6.0). Propensity score matching returned 329 TAVI cases and 593 SAVR controls. Thirty-day mortality was 11 out of 329 (3.32%) in TAVI and 18 out of 593 (3.03%) in SAVR (risk ratio, 1.10; 95% CI, 0.52-2.37; P = .801) groups, respectively. At 2 years, survival curves began to diverge in favor of SAVR, which was associated with 30% lower mortality (hazard ratio, 0.70; 95% CI, 0.496-0.997; P = .048). CONCLUSIONS: Our data did not demonstrate a survival difference between TAVI and SAVR during the first 2 postprocedure years. After that time, SAVR is associated with improved survival. Extended observations from randomized trials in low-risk patients undergoing elective surgery are warranted to confirm these findings and draw definitive conclusions.

12.
Pol Arch Intern Med ; 132(2)2022 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-34845900

RESUMO

INTRODUCTION: Transcatheter aortic valve­in ­valve implantation (ViV­TAVI) has emerged as an alternative to redo surgery in patients with failed surgical aortic bioprosthesis. OBJECTIVES: We evaluated the safety and efficacy of ViV­TAVI in Polish patients after surgical aortic valve replacement. PATIENTS AND METHODS: This was a nationwide multicenter registry of ViV­TAVI procedures. Data were collected using an online form, and the clinical follow ­up lasted 1 year. RESULTS: From 2008 to 2020, 130 ViV­TAVI procedures were performed (1.9% of all transcatheter aortic valve implantation [TAVI] cases). A considerable increase in ViV­TAVI procedures since 2018 has been observed (n = 59, 45% of ViV­TAVI cases). Hancock II, Freestyle, and homograft were the most frequently treated bioprostheses. The self ­expanding supra ­annular Corevalve / Evolut valve was used in 76% of cases. In 21% of cases, the mean postprocedural pressure gradient (PG) exceeded 20 mm Hg. All­cause mortal­ity at 1 year was 10.8%. Aortic valve stenosis was associated with a higher mean PG than aortic valve regurgitation or mixed disease (P = 0.004). Supra ­annular transcatheter aortic valves were associated with lower mean PGs than intra ­annular valves (P = 0.004). Second ­generation devices were associated with shorter procedure time (120 min vs 135 min, P = 0.04), less frequent need for additional TAVI (2% vs 10%, P = 0.04), and lower 1­year cardiovascular mortality (95% vs 82.8%, P = 0.03) than first­generation valves. CONCLUSIONS: Transcatheter treatment of failed bioprostheses is increasingly common, with the best hemodynamic effect shown for supra ­annular valves. The introduction of second­generation valves has improved procedural and clinical outcomes.


Assuntos
Bioprótese , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Humanos , Polônia , Desenho de Prótese , Sistema de Registros , Resultado do Tratamento
13.
Front Cardiovasc Med ; 9: 849971, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35615559

RESUMO

Background: Data regarding management of patients with unprotected left main coronary artery in-stent restenosis (LM-ISR) are scarce. Objectives: This study investigated the safety and effectiveness of percutaneous coronary intervention (PCI) vs. coronary artery bypass grafting (CABG) for the treatment of unprotected LM-ISR. Methods: Consecutive patients who underwent PCI or CABG for unprotected LM-ISR were enrolled. The primary endpoint was a composite of major adverse cardiac and cerebrovascular events (MACCE), defined as cardiac death, myocardial infarction (MI), target vessel revascularization (TVR), and stroke. Results: A total of 305 patients were enrolled, of which 203(66.6%) underwent PCI and 102(33.4%) underwent CABG. At 30-day follow-up, a lower risk of cardiac death was observed in the PCI group, compared with the CABG-treated group (2.1% vs. 7.1%, HR 3.48, 95%CI 1.01-11.8, p = 0.04). At a median of 3.5 years [interquartile range (IQR) 1.3-5.5] follow-up, MACCE occurred in 27.7% vs. 29.6% (HR 0.82, 95%CI 0.52-1.32, p = 0.43) in PCI- and CABG-treated patients, respectively. There were no significant differences between PCI and CABG in cardiac death (9.9% vs. 18.4%; HR 1.56, 95%CI 0.81-3.00, p = 0.18), MI (7.9% vs. 5.1%, HR 0.44, 95%CI 0.15-1.27, p = 0.13), or stroke (2.1% vs. 4.1%, HR 1.79, 95%CI 0.45-7.16, p = 0.41). TVR was more frequently needed in the PCI group (15.2% vs. 6.1%, HR 0.35, 95%CI 0.15-0.85, p = 0.02). Conclusions: This analysis of patients with LM-ISR revealed a lower incidence of cardiac death in PCI compared with CABG in short-term follow-up. During the long-term follow-up, no differences in MACCE were observed, but patients treated with CABG less often required TVR. Visual overview: A visual overview is available for this article. Registration: https://www.clinicaltrials.gov; Unique identifier: NCT04968977.

14.
Ann Thorac Cardiovasc Surg ; 27(4): 267-272, 2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-33563845

RESUMO

PURPOSE: We propose a novel technique for reconstruction of the dissected aortic root with the use of TachoSil fibrin sealant patch. METHODS: Patients with acute type A aortic dissection involving the aortic root were included. Appropriately prepared TachoSil fibrin sealant patch was placed between the dissected layers of the aortic root to achieve their durable fusion. Thus, the false lumen was eliminated, and the anatomical and functional structure of the aortic wall was restored. RESULTS: In all, 13 patients mean aged 57 ± 10.3 years underwent surgery for acute type A aortic dissection with the use of TachoSil fibrin sealant patch. All patients survived the surgery. The mean follow-up time was 30.8 ± 16.4 months. Follow-up computed tomography angiography (CTA) scans confirmed no aortic root dissection in all patients. CONCLUSIONS: This technique ensures durable restoration of the aortic wall structure, eliminates the secondary aortic valve regurgitation, and allows for the preservation of patients' native aortic valve.


Assuntos
Aorta , Dissecção Aórtica , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Combinação de Medicamentos , Adesivo Tecidual de Fibrina/uso terapêutico , Fibrinogênio/uso terapêutico , Humanos , Pessoa de Meia-Idade , Trombina/uso terapêutico , Resultado do Tratamento
15.
Kardiochir Torakochirurgia Pol ; 18(3): 159-164, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34703473

RESUMO

INTRODUCTION: Open aortic arch surgery is a complex cardiac surgical procedure. AIM: We reviewed the 10-year outcomes of elective aortic arch aneurysm surgery in a single cardiac surgical center. MATERIAL AND METHODS: The analysis includes all patients who underwent elective aortic arch surgery at our institution between January 2010 and December 2020. The study population was divided into group A consisting of patients operated on during the first 5 years, and group B, including patients operated on during the subsequent 5 years. The groups were compared with regard to baseline characteristics, scope of the surgery, operative and postoperative data as well as morbidity and mortality. RESULTS: Eighty-six elective aortic arch procedures were performed during the analyzed period, including 25 (29%) patients in group A and 61 (71%) patients in group B. The hemiarch procedure was more frequently performed in group A (17 patients, 68%) in comparison to group B (21 patients, 34%) (p = 0.008). Stroke was recorded in 6 (20%) patients from group A and 5 (8.2%) patients from group B (p = 0.002). Five-year survival was 60 ±9.8% for group A, and 81 ±6.2% for group B (log-rank test, p = 0.003). CONCLUSIONS: After completion of the learning curve, open aortic arch surgery is associated with acceptable early mortality, low incidence of stroke, and a high 5-year survival rate.

16.
J Thorac Cardiovasc Surg ; 162(3): 816-824.e3, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32178919

RESUMO

BACKGROUND: Conduction disturbances necessitating permanent pacemaker (PPM) implantation after cardiac surgery occur in 1% to 5% of patients. Previous studies have reported a low rate of late PPM dependency, but there is lack of evidence that it might be related to implantation timing. In this study, we sought to determine whether PPM implantation timing and specific conduction disturbances as indications for PPM implantation are associated with late pacemaker dependency and recovery of atrioventricular (AV) conduction. METHODS: Patients with a PPM implanted after cardiac surgery were followed in an outpatient clinic. Two outcomes were assessed: AV conduction recovery and PPM dependency, defined as the absence of intrinsic rhythm on sensing test in VVI mode at 40 bpm. RESULTS: Of 15,092 patients operated between September 2008 and March 2019, 185 (1.2%) underwent PPM implantation. One hundred seventy-seven of these patients met the criteria for inclusion into this study. Follow-up data were available in 145 patients (82%). Implantation was performed at ≤6 days after surgery in 58 patients (40%) and at >6 days after surgery in 87 patients (60%). The median time from implantation to last follow-up was 890 days (range, 416-1998 days). At follow-up, 81 (56%) patients were not PPM dependent. Multivariable analysis showed that PPM implantation at ≤6 days after surgery is a predictor of being not PPM dependent (odds ratio [OR], 5.40; 95% confidence interval [CI], 2.43-12.04; P < .001) and of AV conduction recovery (OR, 4.96; 95% CI, 2.26-10.91; P < .001). Sinus node dysfunction as indication for PPM implantation was predictive of being not PPM dependent (OR, 6.59; 95% CI, 1.67-26.06; P = .007). CONCLUSIONS: We recommend implanting a PPM on postoperative day 7 to prevent unnecessary implantations and avoid prolonged hospitalization.


Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Tomada de Decisão Clínica , Técnicas de Apoio para a Decisão , Marca-Passo Artificial , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Artigo em Inglês | MEDLINE | ID: mdl-34682351

RESUMO

Core temperature reflects the temperature of the internal organs. Proper temperature measurement is essential to diagnose and treat temperature impairment in patients. However, an accurate approach has yet to be established. Depending on the method used, the obtained values may vary and differ from the actual core temperature. There is an ongoing debate regarding the most appropriate anatomical site for core temperature measurement. Although the measurement of body core temperature through a pulmonary artery catheter is commonly cited as the gold standard, the esophageal temperature measurement appears to be a reasonable and functional alternative in the clinical setting. This article provides an integrative review of invasive and noninvasive body temperature measurements and their relations to core temperature.


Assuntos
Temperatura Corporal , Projetos de Pesquisa , Humanos , Temperatura
18.
Eur J Cardiothorac Surg ; 59(6): 1183-1190, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-33367683

RESUMO

OBJECTIVES: The aim of this study was to compare the outcomes of tricuspid aortic valve (TAV) and bicuspid aortic valve (BAV) repair. METHODS: We assessed mortality, freedom from reoperation and the rate of aortic valve regurgitation recurrence. Mortality in both groups was compared with expected survival, and risk factors for reoperation were identified. RESULTS: From January 2010 to April 2020, a total of 368 elective aortic valve repair procedures were performed, including 223 (60.6%) in patients with TAV. The perioperative mortality was 0.7% in the BAV group and 3.6% in the TAV group (P = 0.079). Estimated survival at 5 years in the BAV versus TAV group was 97 ± 3% vs 80 ± 6%, respectively (P < 0.001). Freedom from reoperation at 5 years in the TAV versus BAV group was 96 ± 3% vs 93 ± 4%, respectively (P = 0.28). Grade 2 or more aortic valve regurgitation was noted in 9.9% of BAV patients and 11% of TAV patients (P = 0.66). Reoperation was predicted by cusp perforation [hazard ratio 15.86 (4.44-56.61); P < 0.001], the use of pericardial patch [hazard ratio 8.58 (1.96-37.53); P = 0.004] and aortic valve annulus diameter >27.5 mm [hazard ratio 3.07 (0.99-9.58); P = 0.053]. CONCLUSIONS: BAV repair is as durable as TAV repair. BAV is not a predictor of a higher rate of reoperations. BAV repair yields survival comparable to expected. Cusp perforation, aortic valve annulus diameter >27.5 mm and the use of pericardial patch adversely impact long-term outcome of aortic valve repair.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Aorta , Humanos , Estudos Retrospectivos , Resultado do Tratamento
19.
Artigo em Inglês | MEDLINE | ID: mdl-34280995

RESUMO

Hypothermia is defined as a decrease in body core temperature to below 35 °C. In cardiac surgery, four stages of hypothermia are distinguished: mild, moderate, deep, and profound. The organ protection offered by deep hypothermia (DH) enables safe circulatory arrest as a prerequisite to carrying out cardiac surgical intervention. In adult cardiac surgery, DH is mainly used in aortic arch surgery, surgical treatment of pulmonary embolism, and acute type-A aortic dissection interventions. In surgery treating congenital defects, DH is used to assist aortic arch reconstructions, hypoplastic left heart syndrome interventions, and for multi-stage treatment of infants with a single heart ventricle during the neonatal period. However, it should be noted that a safe duration of circulatory arrest in DH for the central nervous system is 30 to 40 min at most and should not be exceeded to prevent severe neurological adverse events. Personalized therapy for the patient and adequate blood temperature monitoring, glycemia, hematocrit, pH, and cerebral oxygenation is a prerequisite and indispensable part of DH.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Hipotermia , Adulto , Aorta Torácica , Temperatura Corporal , Circulação Cerebrovascular , Parada Circulatória Induzida por Hipotermia Profunda , Humanos , Hipotermia/prevenção & controle , Lactente , Recém-Nascido , Resultado do Tratamento
20.
Artigo em Inglês | MEDLINE | ID: mdl-34574690

RESUMO

BACKGROUND: While ECLS is a highly invasive procedure, the identification of patients with a potentially good prognosis is of high importance. The aim of this study was to analyse changes in the acid-base balance parameters and lactate kinetics during the early stages of ECLS rewarming to determine predictors of clinical outcome. METHODS: This single-centre retrospective study was conducted at the Severe Hypothermia Treatment Centre at John Paul II Hospital in Krakow, Poland. Patients ≥18 years old who had a core temperature (Tc) < 30 °C and were rewarmed with ECLS between December 2013 and August 2018 were included. Acid-base balance parameters were measured at ECLS implantation, at Tc 30 °C, and at 2 and 4 h after Tc 30 °C. The alteration in blood lactate kinetics was calculated as the percent change in serum lactate concentration relative to the baseline. RESULTS: We included 50 patients, of which 36 (72%) were in cardiac arrest. The mean age was 56 ± 15 years old, and the mean Tc was 24.5 ± 12.6 °C. Twenty-one patients (42%) died. Lactate concentrations in the survivors group were significantly lower than in the non-survivors at all time points. In the survivors group, the mean lactate concentration decreased -2.42 ± 4.49 mmol/L from time of ECLS implantation until 4 h after reaching Tc 30 °C, while in the non-survivors' group (p = 0.024), it increased 1.44 ± 6.41 mmol/L. CONCLUSIONS: Our results indicate that high lactate concentration is associated with a poor prognosis for hypothermic patients undergoing ECLS rewarming. A decreased value of lactate kinetics at 4 h after reaching 30 °C is also associated with a poor prognosis.


Assuntos
Oxigenação por Membrana Extracorpórea , Hipotermia , Adolescente , Adulto , Idoso , Humanos , Ácido Láctico , Pessoa de Meia-Idade , Estudos Retrospectivos , Reaquecimento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA