Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
IEEE Trans Biomed Eng ; 42(7): 728-31, 1995 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7622156

RESUMO

Raman spectroscopy is a highly specific technique for the identification of molecules by way of the associated characteristic spectra. The aim of this feasibility study is to assess the combination of the multivariate calibration technique of Partial Least-Squares with Raman spectroscopy for the estimation of glucose, lactic acid, and urea concentrations in the presence of each other in a water substrate. The instrument is a CCD-based Raman spectrometer utilizing the 514.5 nm argon laser line. The estimates for the analyte concentrations yielded a standard deviation of concentration residuals of 20.71 mg/dL for glucose, 12.92 mg/dL for lactic acid, and 19.07 mg/dL for urea.


Assuntos
Glucose/análise , Lactatos/análise , Análise dos Mínimos Quadrados , Análise Espectral Raman , Ureia/análise , Calibragem , Estudos de Viabilidade , Humanos , Ácido Láctico , Análise Multivariada
2.
Anal Chem ; 70(1): 35-44, 1998 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-21644597

RESUMO

The mathematical basis of improved calibration through selection of informative variables for partial least-squares calibration has been identified. A theoretical investigation of calibration slopes indicates that including uninformative wavelengths negatively affect calibrations by producing both large relative bias toward zero and small additive bias away from the origin. These theoretical results are found regardless of the noise distribution in the data. Studies are performed to confirm this result using a previously used selection method compared to a new method, which is designed to perform more appropriately when dealing with data having large outlying points by including estimates of spectral residuals. Three different data sets are tested with varying noise distributions. In the first data set, Gaussian and log-normal noise was added to simulated data which included a single peak. Second, near-infrared spectra of glucose in cell culture media taken with an FT-IR spectrometer were analyzed. Finally, dispersive Raman Stokes spectra of glucose dissolved in water were assessed. In every case considered here, improved prediction is produced through selection, but data with different noise characteristics showed varying degrees of improvement depending on the selection method used. The practical results showed that, indeed, including residuals into ranking criteria improves selection for data with noise distributions resulting in large outliers. It was concluded that careful design of a selection algorithm should include consideration of spectral noise distributions in the input data to increase the likelihood of successful and appropriate selection.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA