Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Aten Primaria ; 54(7): 102357, 2022 07.
Artigo em Espanhol | MEDLINE | ID: mdl-35576889

RESUMO

AIM: To study the evolution of the clinical profile of a population discharged with a main diagnosis of heart failure (HF) in the first two decades of the century and the predictive variables of mortality and readmission in the first year of discharge. DESIGN: Observational, retrospective, longitudinal study. SITE: Don Benito Villanueva de la Serena Badajoz health area. PARTICIPANTS: All patients discharged with a main diagnosis of HF between 2000 and 2019 in a general hospital complex were included. MAIN MEASUREMENTS: Sociodemographic and clinical variables were collected, and a one-year follow-up; the result variable was a composite of mortality and/or readmission. RESULTS: A total of 4107 discharges were included, mean age 77.1 (SD±10.5) years, 53.1% women. The number of admissions, age, history of neoplasms, stroke, kidney failure, and anemia increased, as did readmissions (P for trends <.001), while mortality remained constant. Predictive variables for readmission and/or death were HR (95%CI): age (per year) 1.04 (1.03-1.04), diabetes: 1.11 (1.01-1.24), previous HF 1.41 (1.28-1.57), composite variable myocardial infarction, stroke and/or peripheral artery disease 1.24 (1.11-1.38), chronic obstructive pulmonary disease (COPD) 1.29 (1.15-1.44), neoplasia 1.33 (1.16-1.53), anemia 1.63 (1.41-1.86), chronic kidney failure 1.42 (1.26-1.60). CONCLUSIONS: In the last 20 years, admissions for heart failure, patient age, and comorbidity have increased. Predictive variables for mortality and/or readmission were age, diabetes, previous cardiovascular disease, neoplasms, COPD, kidney failure, and anemia; however, mortality at one year remained constant.


Assuntos
Anemia , Insuficiência Cardíaca , Doença Pulmonar Obstrutiva Crônica , Insuficiência Renal , Acidente Vascular Cerebral , Idoso , Feminino , Hospitais , Humanos , Estudos Longitudinais , Masculino , Alta do Paciente , Readmissão do Paciente , Prognóstico , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco
2.
J Cardiovasc Electrophysiol ; 25(9): 976-984, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24716814

RESUMO

BACKGROUND: Certain anatomical characteristics of the left atrial appendage (LAA) are associated with complexity in the implantation of occluder devices. OBJECTIVE: The aim was to define characteristics measurable by three-dimensional imaging that would predict complexities both in the implantation procedure and the selection of the appropriate device size. METHODS: An anatomical study was performed of 50 postmortem hearts, of which 15 had a history of atrial fibrillation, and of 30 consecutive patients undergoing LAA occlusion with the Amplatzer cardiac plug (ACP). The specimens were classified according to variables that can be visualized using computerized tomography (CT). The CT scans of 30 consecutive patients were classified according to the level of the LAA ostium, the left lateral ridge (LLR), the LAA limbus and distance from LAA to the mitral annulus before undergoing LAA occlusion, and the results were correlated. RESULTS: Three types of LAA orifice were defined: type I, with a usually higher, anterior LAA ostium, a short, flattened and wide LLR and almost nonexistent limbus; type II, presenting a long, pointed and narrow LLR, and a longer, more defined limbus; type III, with a lower LAA ostium, close to the left atrium floor and the mitral annulus, a marked separation from the left pulmonary vein orifices and a limbus of intermediate length. CONCLUSION: LAA with lower ostia are more difficult to occlude. Types II and III have very prominent LLRs with longer limbi, which may increase the difficulty of inserting the guide and making measurements for selection of the right ACP size.


Assuntos
Apêndice Atrial/anatomia & histologia , Apêndice Atrial/diagnóstico por imagem , Imageamento Tridimensional , Implantação de Prótese/métodos , Dispositivo para Oclusão Septal , Tomografia Computadorizada por Raios X , Idoso , Cadáver , Humanos , Estudos Longitudinais , Masculino , Estudos Prospectivos
3.
Expert Rev Endocrinol Metab ; : 1-11, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38866705

RESUMO

BACKGROUND: To assess 20-year time trends in the prevalence of diabetes mellitus (DM) among inpatients with heart failure (HF) and the influence of coexisting DM and kidney disease (KD) on outcomes. RESEARCH DESIGN AND METHODS: A retrospective study of patients was admitted due to HF, during the period 2000/2019. The period of follow-up was divided into three intervals according to the European Medical Agency approval of newer hypoglycemic drugs. We analyzed in-hospital mortality and outcomes during the follow-up period. RESULTS: A total of 4959 patients were included. Over time, prevalence of DM was significantly raising among women with HF (50 to 53.2%) and descending among men (50% to 46.8%, p = 0.02). Total mortality and readmissions were higher in patients with DM during the and second periods. However, no significant differences were found in the third-one (HR 1.14, 95% CI 0.94-1.39, p = 0.181). A protector role of oral hypoglycemic medications was observed in this last period. According to the presence of KD, the patients with both DM and KD were who presented most of the events. CONCLUSIONS: Over the time analyzed, the prevalence of DM raised among women and decreased among men. DM influenced the prognosis of HF except in the third period when more protective hypoglycemic drugs started to be used.

4.
Int J Cardiovasc Imaging ; 37(9): 2749-2751, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33959853

RESUMO

An 85-year-old patient with permanent atrial fibrillation with a DDD pacemaker, and with indication for left atrial appendage occlusion (LAAO). Sent for LAAO due to recurrent gastrointestinal bleedings even on apixaban and with a CHA 2 DS 2 VASc and HAS-BLED scores of 4 and 3 respectively.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardiologistas , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/diagnóstico por imagem , Humanos , Valor Preditivo dos Testes , Resultado do Tratamento
5.
Open Heart ; 7(2)2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32747454

RESUMO

OBJECTIVE: Primary percutaneous coronary intervention (P-PCI) has demonstrated its efficacy in patients with ST segment elevation myocardial infarction (STEMI). However, patients with STEMI ≥75 years receive less P-PCI than younger patients despite their higher in-hospital morbimortality. The objective of this analysis was to determine the effectiveness of P-PCI in patients with STEMI ≥75 years. METHODS: We included 979 patients with STEMI ≥75 years, from the ATención HOspitalaria del Síndrome coronario study, a registry of 8142 consecutive patients with acute coronary syndrome admitted at 31 Spanish hospitals in 2014-2016. We calculated a propensity score (PS) for the indication of P-PCI. Patients that received or not P-PCI were matched by PS. Using logistic regression, we compared the effectiveness of performing P-PCI versus non-performance for the composite primary event, which included death, reinfarction, acute pulmonary oedema or cardiogenic shock during hospitalisation. RESULTS: Of the included patients, 81.5 % received P-PCI. The matching provided two groups of 169 patients with and without P-PCI. Compared with its non-performance, P-PCI presented a composite event OR adjusted by PS of 0.55 (95% CI 0.34 to 0.89). CONCLUSIONS: Receiving a P-PCI was significantly associated with a reduced risk of major intrahospital complications in patients with STEMI aged 75 years or older.


Assuntos
Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Edema Pulmonar/mortalidade , Edema Pulmonar/prevenção & controle , Recidiva , Sistema de Registros , Medição de Risco , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Choque Cardiogênico/mortalidade , Choque Cardiogênico/prevenção & controle , Espanha , Fatores de Tempo , Resultado do Tratamento
6.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30389267

RESUMO

INTRODUCTION: Infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI) is an emerging complication. There are incomplete and disparate data on its incidence. We present the experience of a single-centre of incidence, mortality and associated factors of IE after TAVI. METHODS: A retrospective observational study of IE cases in people who received a TAVI, between 06/01/2009 and 11/01/2017, in a university hospital, during a median follow-up period of 15.3months (interquartile range [IQR] 9.1-36.2). Incidence, clinical, microbiological and prognostic data, and factors associated with IE after TAVI were analysed. RESULTS: Eleven patients with IE of 200 TAVI were detected. Global incidence: 5.5% (2.77 cases per 100 patient-year). The median of days from TAVI to IE was 112 (IQR 36-578), the in-hospital mortality rate was 36.4%, and the one-year mortality rate was 54.5%. All the organisms identified were gram-positive (4 Enterococcus faecalis, 3 coagulase-negative Staphylococcus). The patients with IE after TAVI were significantly younger (median 78years, IQR 73-80, versus 82 years, IQR 79-84, P=.002), they had a higher EuroSCORE (5.1±2.4 versus 3.2±1.2, P<.001), and they more frequently had a history of neoplasia (18.2% versus 4.2%, P<.03) CONCLUSIONS: In our area, IE after TAVI has an incidence greater than that described in multicentre series, this is in line with the trend published in the literature. It leads to high mortality and is associated with a worse baseline clinical situation.


Assuntos
Infecção Hospitalar/etiologia , Endocardite Bacteriana/etiologia , Infecções por Bactérias Gram-Positivas/etiologia , Infecção da Ferida Cirúrgica/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Antibioticoprofilaxia , Estenose da Valva Aórtica/cirurgia , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/microbiologia , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/microbiologia , Enterococcus , Enterococcus faecalis/isolamento & purificação , Feminino , Seguimentos , Infecções por Bactérias Gram-Positivas/epidemiologia , Infecções por Bactérias Gram-Positivas/microbiologia , Hospitais Universitários , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Staphylococcus aureus/isolamento & purificação , Staphylococcus epidermidis , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/microbiologia
7.
Rev Esp Cardiol ; 59(7): 696-702, 2006 Jul.
Artigo em Espanhol | MEDLINE | ID: mdl-16938212

RESUMO

INTRODUCTION AND OBJECTIVES: Retrograde aortocoronary dissection is an unusual complication of coronary angioplasty. Our study provides new structural details of the aortic sinuses and the proximal portions of the coronary arteries, which enable better understanding of several clinical features associated with this complication. METHODS: We studied eight aortic sinus specimens from patients with structural ischemic heart disease using dissection, histologic analysis, and scanning electron microscopy, and compared findings with those in eight control specimens. RESULTS: We observed the following features: a) in 10 specimens (71%), the left coronary artery diameter was greater than the right; b) the angle that the ascending aorta made with the left coronary artery was acute, whereas that with the right coronary artery was closer to a right angle, thereby possibly providing a better approach for catheterization; c) in contrast to those of the right coronary artery, the periostial wall and sinotubular junction of the left coronary artery were formed by more smooth muscle cells and by a dense matrix of collagen type-I fibers, and d) the aortic sinuses and coronary arteries in structural ischemic heart disease specimens displayed structural alterations that affected the aortic tunica media and the collagen distribution at the sinotubular junction. CONCLUSIONS: The morphological and structural differences observed between right and left sides suggest that the left aortic sinus is more resistant to traction and is, therefore, less prone to iatrogenic dissection. Structural ischemic heart disease is a risk factor that increases the likelihood of aortocoronary dissection.


Assuntos
Vasos Coronários/patologia , Seio Aórtico/patologia , Adulto , Idoso , Dissecção Aórtica/etiologia , Angioplastia Coronária com Balão/efeitos adversos , Aneurisma Aórtico/etiologia , Cadáver , Aneurisma Coronário/etiologia , Feminino , Humanos , Complicações Intraoperatórias/etiologia , Masculino , Pessoa de Meia-Idade
8.
Arch Bronconeumol ; 42(11): 608-10, 2006 Nov.
Artigo em Espanhol | MEDLINE | ID: mdl-17125698

RESUMO

Symptoms such as cough and hemoptysis in patients with lung cancer can be the consequence of local bronchopulmonary disease, tumor growth that leads to compression of surrounding structures, distant metastases, diverse systemic effects (anorexia, asthenia, weight loss), or paraneoplastic syndromes associated with tumor production of certain hormones. Approximately 10% of patients are asymptomatic at diagnosis. We report the case of a 77-year-old man with dyspnea, pleuritic chest pain, and lower limb edema. The patient died within a few days. The cause of the clinical picture was constrictive pericarditis secondary to metastases from lung carcinoma.


Assuntos
Neoplasias Cardíacas/secundário , Neoplasias Pulmonares/diagnóstico , Pericardite Constritiva/diagnóstico , Idoso , Diagnóstico Diferencial , Diagnóstico Precoce , Evolução Fatal , Neoplasias Cardíacas/diagnóstico , Humanos , Neoplasias Pulmonares/patologia , Masculino , Segunda Neoplasia Primária/diagnóstico , Pericardite Constritiva/diagnóstico por imagem , Tomografia Computadorizada por Raios X
9.
Rev Port Cardiol ; 35(4): 239.e1-5, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27004431

RESUMO

Transcatheter aortic valve replacement (TAVR) is an increasingly common procedure for the treatment of aortic stenosis in elderly patients with comorbidities that prevent the use of standard surgery. It has been shown that implantation without aortic regurgitation is related to lower mortality. Mild paravalvular regurgitation is inevitable in some cases due to calcification of the aortic annulus and its usually somewhat elliptical shape. Central regurgitation is less common, but has been associated with valve overdilatation in cases in which reduction of paravalvular regurgitation was attempted after the initial inflation. However, there are no reported cases of central prosthetic aortic regurgitation due to acute LV dysfunction. We report a case in which central aortic regurgitation occurred due to transient ventricular dysfunction secondary to occlusion of the right coronary artery by an embolus. The regurgitation disappeared after thrombus aspiration and normal ventricular function was immediately recovered.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Aórtica , Estenose da Valva Aórtica , Embolia , Humanos
11.
Cardiovasc Revasc Med ; 15(5): 301-4, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24767195

RESUMO

SUMMARY: We present two cases of right coronary artery occlusion in which MGuard® stent implantation failed for different causes, leading to a retrieval procedure adapted to the situation. Complete retrieval was possible in both cases. These cases illustrate the need for careful selection of the lesions that are going to be treated with this type of stent, for which pre-dilatation is recommended in severe lesions located just after an acute vessel angle, the evaluation of proximal angulation and calcification, as well as strategies for complete retrieval in case of implantation failure.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Circulação Coronária/efeitos dos fármacos , Dispositivos de Proteção Embólica , Infarto do Miocárdio/terapia , Stents , Idoso , Angiografia Coronária , Humanos , Masculino , Resultado do Tratamento
12.
J Invasive Cardiol ; 26(9): 462-7, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25198490

RESUMO

BACKGROUND: The adequate device size selection for left atrial appendage closure is crucial to ensuring adequate implantation and for avoiding the need for multiple attempts that increase the risk of complications. Our aim was to evaluate the information obtained using different imaging techniques to select the size of the closure device in a clinical environment. METHODS: Thirty-seven patients who consecutively underwent implantation of Amplatzer cardiac plug (ACP) devices were studied. All patients were examined using computed tomography (CT) prior to intervention. Measurements were compared to those obtained using intraoperative transesophageal echocardiography (IOTEE) and angiography. Size was determined by the longest axis of the appendage ostium. The influence of all techniques on the correct selection of final size was assessed. RESULTS: The measurements taken using the three techniques agreed in only 21.6% of the cases, leading to accurate selection of device size. Two techniques coincided as follows: IOTEE-CT in 45.9%, angiography-CT in 35.13%, and angiography-IOTEE in 24.3%. Measurements using CT were definitive for ACP selection in 75.7% of cases, angiography in 48.6%, and echocardiography in 51.4%. Device size was undermeasured with angiography in 35.1% of cases, and with IOTEE in 24.3%; CT overmeasured 21.6% of cases. The combination of angiography-CT was the most accurate for selection of device size. CONCLUSION: CT most often predicts the appropriate device size. If it fails, it usually overestimates the size. Agreement of measurements with all three techniques is the most accurate situation; when two agree, the most accurate combination is angiography and CT.


Assuntos
Apêndice Atrial/anatomia & histologia , Imageamento Tridimensional/métodos , Dispositivo para Oclusão Septal/estatística & dados numéricos , Dispositivo para Oclusão Septal/normas , Idoso , Idoso de 80 Anos ou mais , Angiografia , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/patologia , Ecocardiografia Transesofagiana , Desenho de Equipamento , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Tomografia Computadorizada por Raios X
13.
EuroIntervention ; 10(1): 50-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24832638

RESUMO

AIMS: Paclitaxel drug-eluting balloons (pDEB) could be an attractive option to minimise side branch (SB) restenosis in bifurcated coronary lesions. We compared angiographic and clinical outcomes with pDEB plus bare metal stent (BMS) versus drug-eluting stents (DES) in de novo bifurcated lesions. METHODS AND RESULTS: This multicentre randomised trial included 108 patients. Sequential main branch (MB)/SB dilatation with pDEB, with provisional T-stenting with BMS in the MB was performed in the pDEB group, and with everolimus DES in the DES group. The primary endpoint was late lumen loss (LLL) at nine months. The secondary endpoint was the incidence of major adverse cardiac events (MACE: death, myocardial infarction, or target lesion revascularisation). In-segment MB LLL was 0.31±0.48 mm in the pDEB group, and 0.16±0.38 mm in the DES group (p=0.15); mean difference was 0.15 mm (upper limit one-sided 95% CI: 0.27 mm; p=0.001; non-inferiority test). LLL in SB was -0.04±0.76 mm in the pDEB group and -0.03±0.51 mm in the DES group (p=0.983). MACE and TLR were higher in the pDEB group (17.3% vs. 7.1%; p=0.105, and 15.4% vs. 3.6%; p=0.045), due to higher MB restenosis (13.5% vs. 1.8%; p=0.027). CONCLUSIONS: pDEB bifurcation pretreatment with BMS implantation in MB showed greater LLL (ns) and increased incidence of MACE compared to everolimus DES. Both strategies showed similar results in the SB.


Assuntos
Angina Pectoris/terapia , Angioplastia Coronária com Balão/métodos , Reestenose Coronária/prevenção & controle , Estenose Coronária/terapia , Paclitaxel/uso terapêutico , Moduladores de Tubulina/uso terapêutico , Idoso , Angina Pectoris/etiologia , Aspirina/uso terapêutico , Clopidogrel , Angiografia Coronária , Estenose Coronária/complicações , Stents Farmacológicos , Everolimo , Feminino , Humanos , Imunossupressores/uso terapêutico , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Sirolimo/análogos & derivados , Sirolimo/uso terapêutico , Stents , Ticlopidina/análogos & derivados , Ticlopidina/uso terapêutico , Resultado do Tratamento
17.
Rev Esp Cardiol (Engl Ed) ; 66(2): 90-7, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24775381

RESUMO

INTRODUCTION AND OBJECTIVES: Left atrial appendage closure can be an attractive option for patients with nonvalvular atrial fibrillation and a contraindication to oral anticoagulants, provided that satisfactory results can be achieved during implantation and follow-up. METHODS: Thirty-five consecutive patients, not eligible for randomized trials with oral anticoagulants, had an Amplatzer occlusion device implanted under general anesthesia. After the first 5 patients, 3-dimensional imaging was incorporated. The results of the implantation and the follow-up were analyzed over a 1-year period. RESULTS: The mean age was 74.65 (7.61) years, with a CHADS2 score of 2.41 (1.53) and a CHA2DS2-VASc score of 3.17 (1.60). Implantation failed in 1 patient and 5 needed a change in the selected plug size. There were no cardiac complications during the implantation or hospital stay. There was 1 vascular complication (arteriovenous fistula). Transesophageal echocardiography monitoring was performed at 24h, 1, 3, 6, and 12 months and we found 5 thrombi which were resolved with heparin. In the follow-up period of 21.14 (10.09) months, 3 patients aged>80 years died, none of them due to heart problems, and one transient ischemic stroke without further consequences. CONCLUSIONS: Left atrial appendage closure by an experienced operator can be a treatment option with few complications and with efficient results at>1 year in reducing thromboembolic and hemorrhagic complications, even in very high-risk groups.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Dispositivo para Oclusão Septal , Idoso , Feminino , Seguimentos , Humanos , Masculino , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA