Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Am J Respir Crit Care Med ; 185(4): 427-34, 2012 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-22161162

RESUMO

RATIONALE: There is uncertainty regarding how to interpret discordance between tests for latent tuberculosis infection. OBJECTIVES: The objective of this study was to assess discordance between commercially available tests for latent tuberculosis in a low-prevalence population, including the impact of nontuberculous mycobacteria. METHODS: This was a cross-sectional comparison study among 2,017 military recruits at Fort Jackson, South Carolina, from April to June 2009. Several tests were performed simultaneously with a risk factor questionnaire, including (1) QuantiFERON-TB Gold In-Tube test, (2) T-SPOT.TB test, (3) tuberculin skin test, and (4) Battey skin test using purified protein derivative from the Battey bacillus. MEASUREMENTS AND MAIN RESULTS: In this low-prevalence population, the specificities of the three commercially available diagnostic tests were not significantly different. Of the 88 subjects with a positive test, only 10 (11.4%) were positive to all three tests; 20 (22.7%) were positive to at least two tests. Bacille Calmette-Guérin vaccination, tuberculosis prevalence in country of birth, and Battey skin test reaction size were associated with tuberculin skin test-positive, IFN-γ release assay-negative test discordance. Increasing agreement between the three tests was associated with epidemiologic criteria indicating risk of infection and with quantitative test results. CONCLUSIONS: For most positive results the three tests identified different people, suggesting that in low-prevalence populations most discordant results are caused by false-positives. False-positive tuberculin skin test reactions associated with reactivity to nontuberculous mycobacteria and bacille Calmette-Guérin vaccination may account for a proportion of test discordance observed.


Assuntos
Antígenos de Bactérias , Testes de Liberação de Interferon-gama , Tuberculose Latente/diagnóstico , Complexo Mycobacterium avium/imunologia , Teste Tuberculínico/métodos , Adolescente , Adulto , Estudos Transversais , Reações Falso-Positivas , Feminino , Humanos , Testes de Liberação de Interferon-gama/normas , Tuberculose Latente/epidemiologia , Tuberculose Latente/microbiologia , Masculino , Análise Multivariada , Prevalência , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , South Carolina/epidemiologia , Inquéritos e Questionários , Teste Tuberculínico/normas
2.
Clin Infect Dis ; 53(3): 234-44, 2011 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-21765072

RESUMO

BACKGROUND: The interferon-γ release assays (IGRAs) are increasingly being used as an alternative to the tuberculin skin test (TST). Although IGRAs may have better specificity and certain logistic advantages to the TST, their use may contribute to overtesting of low-prevalence populations if testing is not targeted. The objective of this study was to evaluate the accuracy of a risk factor questionnaire in predicting a positive test result for latent tuberculosis infection using the 3 commercially available diagnostics. METHODS: A cross-sectional comparison study was performed among recruits undergoing Army basic training at Fort Jackson, South Carolina, from April through June 2009. The tests performed included: (1) a risk factor questionnaire; (2) the QuantiFERON Gold In-Tube test (Cellestis Limited, Carnegie, Victoria, Australia); (3) the T-SPOT.TB test (Oxford Immunotec Limited, Abingdon, United Kingdom); and (4) the TST (Sanofi Pasteur Ltd., Toronto, Ontario, Canada). Prediction models used logistic regression to identify factors associated with positive test results. RFQ prediction models were developed independently for each test. RESULTS: Use of a 4-variable model resulted in 79% sensitivity, 92% specificity, and a c statistic of 0.871 in predicting a positive TST result. Targeted testing using these risk factors would reduce testing by >90%. Models predicting IGRA outcomes had similar specificities as the skin test but had lower sensitivities and c statistics. CONCLUSIONS: As with the TST, testing with IGRAs will result in false-positive results if the IGRAs are used in low-prevalence populations. Regardless of the test used, targeted testing is critical in reducing unnecessary testing and treatment. CLINICAL TRIAL REGISTRATION: NCT00804713.


Assuntos
Técnicas de Laboratório Clínico/métodos , Tuberculose Latente/diagnóstico , Adolescente , Adulto , Estudos Transversais , Feminino , Humanos , Imunoensaio/métodos , Masculino , Valor Preditivo dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade , South Carolina , Inquéritos e Questionários , Adulto Jovem
3.
Mil Med ; 179(3): 333-41, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24594471

RESUMO

We automated portions of the QuantiFERON-TB Gold In-Tube test (QFT-GIT) and assessed its quality when performed concurrently with the tuberculin skin test (TST) among U.S. Air Force basic military trainees (BMTs). The volume of blood collected for QFT-GIT was monitored. At least one of the three tubes required for QFT-GIT had blood volume outside the recommended 0.8- to 1.2-mL range for 688 (29.0%) of 2,373 subjects who had their blood collected. Of the 2,124 subjects who had TST and QFT-GIT completed, TST was positive for 0.6%; QFT-GIT was positive for 0.3% and indeterminate for 2.0%. Among 2,081 subjects with completed TST and determinate QFT-GIT results, overall agreement was 99.5% but positive agreement was 5.6%. Specificity among the 1,546 low-risk BMTs was identical (99.7%). Indeterminate QFT-GIT results were 2.7 times more likely when mitogen tubes contained >1.2 mL blood than when containing 0.8- to 1.2-mL blood. Automation can facilitate QFT-GIT completion, especially if the recommended volume of blood is collected. Mycobacterium tuberculosis infection prevalence among BMTs based on TST and QFT-GIT is similar and low. Selectively testing those with significant risk may be more appropriate than universal testing of all recruits.


Assuntos
Anticorpos Antibacterianos/análise , Automação , Testes de Liberação de Interferon-gama/métodos , Militares , Mycobacterium tuberculosis/imunologia , Teste Tuberculínico/métodos , Tuberculose/diagnóstico , Adulto , Feminino , Seguimentos , Humanos , Incidência , Masculino , Prevalência , Estudos Retrospectivos , Tuberculose/epidemiologia , Tuberculose/microbiologia , Estados Unidos/epidemiologia , Adulto Jovem
4.
PLoS One ; 9(1): e86721, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24466211

RESUMO

BACKGROUND: The QuantiFERON®-TB Gold In-Tube test (QFT-GIT) detects Mycobacterium tuberculosis (Mtb) infection by measuring release of interferon gamma (IFN-γ) when T-cells (in heparinized whole blood) are stimulated with specific Mtb antigens. The amount of IFN-γ is determined by enzyme-linked immunosorbent assay (ELISA). Automation of the ELISA method may reduce variability. To assess the impact of ELISA automation, we compared QFT-GIT results and variability when ELISAs were performed manually and with automation. METHODS: Blood was collected into two sets of QFT-GIT tubes and processed at the same time. For each set, IFN-γ was measured in automated and manual ELISAs. Variability in interpretations and IFN-γ measurements was assessed between automated (A1 vs. A2) and manual (M1 vs. M2) ELISAs. Variability in IFN-γ measurements was also assessed on separate groups stratified by the mean of the four ELISAs. RESULTS: Subjects (N = 146) had two automated and two manual ELISAs completed. Overall, interpretations were discordant for 16 (11%) subjects. Excluding one subject with indeterminate results, 7 (4.8%) subjects had discordant automated interpretations and 10 (6.9%) subjects had discordant manual interpretations (p = 0.17). Quantitative variability was not uniform; within-subject variability was greater with higher IFN-γ measurements and with manual ELISAs. For subjects with mean TB Responses ±0.25 IU/mL of the 0.35 IU/mL cutoff, the within-subject standard deviation for two manual tests was 0.27 (CI95 = 0.22-0.37) IU/mL vs. 0.09 (CI95 = 0.07-0.12) IU/mL for two automated tests. CONCLUSION: QFT-GIT ELISA automation may reduce variability near the test cutoff. Methodological differences should be considered when interpreting and using IFN-γ release assays (IGRAs).


Assuntos
Automação Laboratorial , Ouro , Testes de Liberação de Interferon-gama/métodos , Interferon gama/sangue , Mycobacterium tuberculosis/patogenicidade , Teste Tuberculínico/métodos , Tuberculose/diagnóstico , Adulto , Antígenos de Bactérias/imunologia , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Interferon gama/metabolismo , Masculino , Pessoa de Meia-Idade , Mycobacterium tuberculosis/imunologia , Linfócitos T/imunologia , Tuberculose/sangue , Tuberculose/imunologia , Adulto Jovem
5.
Mil Med ; 178(3): 346-52, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23707124

RESUMO

BACKGROUND: Nonimmigrant visitors are not required to be evaluated for tuberculosis (TB) before entering the country. Little literature exists describing the challenges of TB control among this demographic. This report reviews the challenges in managing TB in this population on U.S. military installations. METHODS: Six cases were identified from reportable medical event reports. Information was obtained from public health personnel via phone interviews. Verified cases from 2004 to 2011 were included. RESULTS: Challenges were congruent among locations including: lack of procedures to screen for infection and disease among individuals at time of entry allowing one case to be admitted with acquired immunodeficiency syndrome and another concurrently on treatment for active TB; delays in the diagnosis of active TB as median time from entry to diagnosis was 62 days; and the need to conduct an effective contact investigation as the mean contact index was 77 including 1 secondary case of active TB. CONCLUSIONS: These cases emphasize the need for screening for TB in visitors from high-risk countries at time of entry, prompt diagnosis and treatment if found, procedures for evaluation of contacts, and interjurisdictional cooperation in large contact investigations. These challenges are common to nonimmigrants in both military and civilian settings.


Assuntos
Busca de Comunicante/métodos , Militares , Viagem , Tuberculose/etnologia , Humanos , Masculino , Tuberculose/diagnóstico , Estados Unidos/epidemiologia
6.
PLoS One ; 7(9): e43790, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22970142

RESUMO

BACKGROUND: The QuantiFERON®-TB Gold In-Tube test (QFT-GIT) is a viable alternative to the tuberculin skin test (TST) for detecting Mycobacterium tuberculosis infection. However, within-subject variability may limit test utility. To assess variability, we compared results from the same subjects when QFT-GIT enzyme-linked immunosorbent assays (ELISAs) were performed in different laboratories. METHODS: Subjects were recruited at two sites and blood was tested in three labs. Two labs used the same type of automated ELISA workstation, 8-point calibration curves, and electronic data transfer. The third lab used a different automated ELISA workstation, 4-point calibration curves, and manual data entry. Variability was assessed by interpretation agreement and comparison of interferon-γ (IFN-γ) measurements. Data for subjects with discordant interpretations or discrepancies in TB Response >0.05 IU/mL were verified or corrected, and variability was reassessed using a reconciled dataset. RESULTS: Ninety-seven subjects had results from three labs. Eleven (11.3%) had discordant interpretations and 72 (74.2%) had discrepancies >0.05 IU/mL using unreconciled results. After correction of manual data entry errors for 9 subjects, and exclusion of 6 subjects due to methodological errors, 7 (7.7%) subjects were discordant. Of these, 6 (85.7%) had all TB Responses within 0.25 IU/mL of the manufacturer's recommended cutoff. Non-uniform error of measurement was observed, with greater variation in higher IFN-γ measurements. Within-subject standard deviation for TB Response was as high as 0.16 IU/mL, and limits of agreement ranged from -0.46 to 0.43 IU/mL for subjects with mean TB Response within 0.25 IU/mL of the cutoff. CONCLUSION: Greater interlaboratory variability was associated with manual data entry and higher IFN-γ measurements. Manual data entry should be avoided. Because variability in measuring TB Response may affect interpretation, especially near the cutoff, consideration should be given to developing a range of values near the cutoff to be interpreted as "borderline," rather than negative or positive.


Assuntos
Técnicas de Laboratório Clínico/métodos , Kit de Reagentes para Diagnóstico , Tuberculose/diagnóstico , Tuberculose/epidemiologia , Adulto , Idoso , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Interferon gama/sangue , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Tuberculose/sangue , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA