Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
J Hosp Infect ; 111: 176-179, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33582203

RESUMO

Safe measurements to prevent the transmission of (multidrug-resistant) mycobacteria such as disinfection are essential in healthcare settings. In Europe chemical disinfectants are tested for their tuberculocidal and mycobactericidal efficacy by the internationally accepted test procedure described in EN 14348. However, especially for amine-based disinfectants, invalid results may occur by this procedure due to insufficient neutralization. In this multi-laboratory study the procedure described in EN 14348 was optimized by a combination of chemical neutralization and membrane filtration in order to obtain a valid and secure method especially for amine-based disinfectants.


Assuntos
Desinfetantes , Mycobacterium , Desinfecção , Europa (Continente) , Humanos , Mycobacterium/efeitos dos fármacos
2.
J Hosp Infect ; 104(4): 567-573, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31836550

RESUMO

BACKGROUND: A rapid test system using fluorescent Mycobacterium terrae to evaluate the tuberculocidal efficacy of disinfectants has recently been published. Results were obtained in a significantly shorter time than was previously possible. AIM: To compare the European Standard test system with the fluorescence assay and to validate the rapid test system, including particularly the quantitative suspension test. METHODS: Quantitative suspension tests and quantitative carrier tests were carried out according to EN 14348 and EN 14563, respectively. Quantitative carrier tests and subsequent green fluorescent protein (GFP)-based determination of germicidal efficacy were carried out as described previously. A peracetic acid-based formulation was used as a test germicide. FINDINGS: Testing of the germicide in the quantitative suspension test EN 14348 and in the quantitative carrier test EN 14563 revealed tuberculocidal efficacy at a concentration of 1% after 15 min contact time. Accordingly, data obtained from the fluorescence assay demonstrated that a germicide concentration of 1% was effective after 15 min, indicating no live mycobacteria following this treatment. Thus, identical in-use parameters for tuberculocidal efficacy were obtained either by applying the quantitative suspension and quantitative carrier tests EN 14348 and EN 14563 or by using the GFP-based rapid test system. CONCLUSION: The GFP-based rapid test system compares well with the established European Standard test procedure including both phase 2, step 1 and phase 2, step 2 tests and provides a rapid and sensitive tool for testing germicides for relevant in-use concentrations and contact times.


Assuntos
Bioensaio/métodos , Desinfetantes/farmacologia , Micobactérias não Tuberculosas/efeitos dos fármacos , Europa (Continente) , Fluorescência , Humanos , Testes de Sensibilidade Microbiana
3.
J Appl Microbiol ; 104(2): 454-64, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17961156

RESUMO

AIM: To prevent further outbreaks of hypersensitivity pneumonitis (HP), biocides are required which are capable of protecting water-based coolants from proliferating mycobacteria. The aim of this study was therefore, to test different biocide preparations on their mycobactericidal activity. METHODS AND RESULTS: Minimal inhibitory concentration values were determined for Mycobacterium chelonae and Mycobacterium immunogenum for triazine-based, methyloxazolidine-based, N/O-formal-based biocidal formulations. All biocides were effective already at a low dosage (<0.05%) irrespective of the presence or absence of organic soiling, except for one N/O-formal-based formulation containing Kathon 886 (CMI). Quenching of CMI in the presence of organic soiling was found to account for loss in efficacy as determined by high-performance liquid chromatography measurement. Preservation tests were carried out to investigate the efficacy of the biocidal preparations under practical conditions. CONCLUSIONS: Results indicate that methyloxazolidine-based biocidal preparations were most effective to prevent coolants from microbial contamination including rapidly growing mycobacteria. Furthermore, it could be demonstrated that common dipslides can be used to easily monitor coolants for contamination by mycobacteria. SIGNIFICANCE AND IMPACT OF THE STUDY: Our data does not support the hypothesis that mycobacterial proliferation is enhanced by the reduction of competitive microbial population by biocides such as triazines as described earlier but rather suggests a protective effect of biocides regarding mycobacteria in the presence of competitive microbial flora, thereby preventing further outbreaks of HP.


Assuntos
Alveolite Alérgica Extrínseca/microbiologia , Desinfetantes/farmacologia , Microbiologia Industrial , Metalurgia , Infecções por Mycobacterium/prevenção & controle , Doenças Profissionais/microbiologia , Alveolite Alérgica Extrínseca/prevenção & controle , Técnicas Bacteriológicas , Humanos , Testes de Sensibilidade Microbiana , Mycobacterium/efeitos dos fármacos , Mycobacterium/crescimento & desenvolvimento , Mycobacterium chelonae/efeitos dos fármacos , Mycobacterium chelonae/crescimento & desenvolvimento , Doenças Profissionais/prevenção & controle
4.
Int Dent J ; 56(4): 187-95, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16972392

RESUMO

UNLABELLED: Dental Unit Water Systems (DUWS) are used in dental practices to provide water for cooling of dental equipment and irrigation of the oral cavity. However, they have been demonstrated to be contaminated with micro-organisms. There are currently no European Union (EU) Commission guidelines for the microbial quality of water discharged by DUWS. This study was part of an EU research programme to investigate the microbial contamination of DUWS in general dental practice (GDP) in the UK, Denmark, Germany, The Netherlands, Ireland, Greece and Spain. OBJECTIVE: To undertake a questionnaire survey on the type of DUWS in use and determine the attitude of GDPs to the risk of microbial infection from DUWS. MATERIALS AND METHODS: The questionnaire was written and translated into the language of each country before being posted to each participating dentist. Dentists were asked to complete the questionnaire survey and return it by post. RESULTS AND CONCLUSIONS: The major findings were that the majority of dentists did not clean, disinfect or determine the microbial load of their DUWS, and that dentists would welcome regular monitoring and advice on maintaining their DUWS; the introduction of guidelines; and recommendations on controlling the microbial load of DUWS.


Assuntos
Atitude do Pessoal de Saúde , Equipamentos Odontológicos/microbiologia , Controle de Infecções Dentárias/métodos , Abastecimento de Água , Europa (Continente) , Humanos , Inquéritos e Questionários , Microbiologia da Água/normas , Abastecimento de Água/normas
5.
J Hosp Infect ; 61(2): 168-75, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16023258

RESUMO

With the widespread use of continuous positive airways pressure (CPAP) therapy, the safety of CPAP devices after reprocessing is the subject of debate. In this study, the contamination of CPAP devices and the effectiveness of disinfection was investigated. A total of 122 CPAP devices were examined including 50 CPAP devices used by patients, which were examined before and after reprocessing. Seventy-two new CPAP devices that had not been in contact with patients served as controls. The results of this study show that the microbial contamination of new and used CPAP devices is only minimal. Contaminating micro-organisms were predominantly micro-organisms reflecting the normal environmental microflora such as Penicillium spp., Aspergillus spp., Micrococcaceae and Bacillaceae. Gram-negative species could only be found in rare cases. The data obtained give no indication of poor disinfection of CPAP devices.


Assuntos
Bacillaceae/isolamento & purificação , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Desinfecção/métodos , Contaminação de Equipamentos , Fungos/isolamento & purificação , Micrococcaceae/isolamento & purificação , Microbiologia do Ar , Contagem de Colônia Microbiana , Pressão Positiva Contínua nas Vias Aéreas/métodos , Segurança de Equipamentos , Humanos
6.
J Hosp Infect ; 55(3): 220-5, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14572490

RESUMO

In Europe, the antimicrobial efficacy of alcohol-based hand rubs is determined with a quantitative suspension test (prEN 12054) and a test under practical conditions (EN 1500). Another test method has recently been published by the German Society for Hygiene and Microbiology (DGHM) with four differences to the European system in the in vitro tests: additional qualitative suspension tests with product dilutions to the ineffective range; a selection of the most resistant Gram-negative test strains in the qualitative suspension test, which should be used adjacent to Pseudomonas aeruginosa in the quantitative suspension test; a high organic load in the quantitative suspension tests (0.3% albumin and 0.3% sheep erythrocytes); and an aqueous control in the quantitative suspension test. According to DGHM, the in vitro tests should be followed by EN 1500. We have determined the antimicrobial efficacy of three commonly used alcohol-based hand rubs according to both methods. prEN 12054 was carried out without organic load. The qualitative suspension tests (DGHM) were carried out with P. aeruginosa, Escherichia coli, Proteus mirabilis, Staphylococcus aureus, Enterococcus hirae and Candida albicans. The quantitative suspension test (DGHM) was carried out with product dilutions of 75%, 50% and 25%, and a high organic load using the following test organisms: P. aeruginosa, P. mirabilis (one product only), S. aureus, E. hirae and C. albicans. All these suspension tests were carried out in quadruplicate with each product and exposure time. EN 1500 was carried out with 3 mL of each product and an application time of 30 s. All three products achieved the required bactericidal activity of prEN 12054 and the new DGHM method within 30 s, and were equally effective with the reference hand disinfection of EN 1500 within 30 s. In our study, the DGHM test method did not provide additional information for hand rubs which exhibit their bactericidal efficacy with 3 mL within 30 s (EN 1500).


Assuntos
Álcoois/farmacologia , Bactérias/efeitos dos fármacos , Desinfetantes/farmacologia , Desinfecção das Mãos/métodos , Humanos
7.
J Hosp Infect ; 56(1): 49-55, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14706271

RESUMO

Hand disinfection is an important measure to prevent transmission of norovirus (formerly called Norwalk-like viruses) from hands or environmental surfaces to other objects. Therefore, three types of alcohol (ethanol, 1- and 2-propanol) were examined for their virus-inactivating properties against feline calicivirus (FCV) as a surrogate for norovirus. Tests were performed as quantitative suspension assays or as in vivo experiments with artificially contaminated fingertips. The in vitro experiments showed that 1-propanol was more effective than ethanol and 2-propanol for the inactivation of FCV: in tests with the 50 and 70% solutions of the different alcohols, a 10(4)-fold reduction was observed with 1-propanol after 30 s, whereas the other alcohols were effective only after 3 min contact time. The greatest efficacy did not occur at the highest concentrations (80%). The following concentrations (extrapolated data) showed the greatest virus-inactivating properties in the suspension test: ethanol 67%, 2-propanol 58% (exposure times of 1 min) and 1-propanol 60% (exposure time of 30 s). The results from fingertips experiments with 70 and 90% solutions and an application time of 30 s confirmed these findings: the 70% alcoholic solutions were more effective than the 90% solutions. In contrast to the suspension tests, 70% ethanol showed the greatest efficacy in vivo with a log(10) reduction factor (RF) of 3.78 compared with 70% 1-propanol (RF 3.58), 70% 2-propanol (RF 2.15) and hard water (RF 1.23). Ethanol and 1-propanol-based solutions with a high alcohol content thus appear most effective.


Assuntos
1-Propanol/farmacologia , 2-Propanol/farmacologia , Anti-Infecciosos Locais/farmacologia , Calicivirus Felino/efeitos dos fármacos , Desinfecção/métodos , Etanol/farmacologia , Infecções por Caliciviridae/prevenção & controle , Infecções por Caliciviridae/transmissão , Desinfecção das Mãos/métodos , Humanos , Técnicas In Vitro , Norovirus/efeitos dos fármacos
8.
Int J Hyg Environ Health ; 204(2-3): 123-6, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11759154

RESUMO

It was the aim of this study to compare the efficacy of alcohol-based hand disinfectants according to European Standard EN 1500 (hygienic handrub), using the routine test organism Escherichia coli and, additionally, Micrococcus luteus as a surrogate for Gram-positive pathogens. One ethanol-based hand disinfectant (product A) and one propanol-based hand disinfectant (product B) were used in all experiments. Product B (propanol-based) was significantly more effective against both test organisms than product A (ethanol-based) in quantitative suspension tests but not in tests simulating practical conditions. In the experiments according to EN 1500 germ reduction rates obtained with the ethanol-containing formulation A were identical for E. coli and M. luteus. Product B was slightly, but not significantly more effective against M. luteus. To conclude, using E. coli as the test organism for evaluating the antibacterial efficacy of alcoholic hand disinfectants under practical conditions even appears to be sufficient to permit the drawing of conclusions for Gram-positive pathogens. However, more alcohol-based hand disinfectants should be tested in further studies to verify the results obtained.


Assuntos
Desinfetantes/farmacologia , Escherichia coli , Desinfecção das Mãos , Micrococcus luteus , Anti-Infecciosos Locais/farmacologia , Etanol/farmacologia , Controle de Infecções/métodos
9.
Folia Microbiol (Praha) ; 49(6): 718-24, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15881409

RESUMO

The long-term action of recommended (RC) and near-recommended concentrations of several commercial biocides (Lonzabac 12.100, Genamin CS302D, benzalkonium chloride and 2-phenoxyethanol) on cells of S. cerevisiae wild-type strain DTXII was described using plating tests while short-term effects were determined using the potentiometric fluorescent probe diS-C3(3) that detects both changes in membrane potential and impairment of membrane integrity. A 2-d plating of cells exposed to 0.5xRC of benzalkonium chloride and Genamin CS302D for 15 min showed a complete long-term cell killing, with 2-phenoxyethanol the killing was complete only at 2xRC and Lonzabac caused complete killing at RC but not at 0.5xRC. The diS-C3(3) fluorescence assay performed immediately after a 10-min biocide exposure revealed several concentration-dependent modes of action: Lonzabac at 0.5xRC caused a mere depolarization, higher concentrations causing gradually increasing cell damage; benzalkonium chloride and Genamin CS302D rapidly damaged the membrane of some cells and depolarized the rest whereas 2-phenoxyethanol, which had the lowest effect in the plating test, produced a concentration-dependent fraction of cells with impaired membranes. Cell staining slightly increased during the diS-C3(3) assay; addition of a protonophore showed that part of the remaining undamaged cells retained their membrane potential. Comparison of short-term and long-term data implies that membrane depolarization alone is not sufficient for complete long-term killing of yeast cells under the action of a biocide unless it is accompanied by perceptible impairment of membrane integrity. The results show that the diS-C3(3) fluorescence assay, which reflects the short-term effects of a biocide on cell membranes, can be successfully used to assess the microbicidal efficiency of biocides.


Assuntos
Anti-Infecciosos/farmacologia , Membrana Celular/efeitos dos fármacos , Saccharomyces cerevisiae/efeitos dos fármacos , Saccharomyces cerevisiae/crescimento & desenvolvimento , Compostos de Benzalcônio/farmacologia , Carbocianinas/metabolismo , Permeabilidade da Membrana Celular/efeitos dos fármacos , Etilenoglicóis/farmacologia , Corantes Fluorescentes/metabolismo , Potenciais da Membrana/efeitos dos fármacos , Testes de Sensibilidade Microbiana/métodos , Espectrometria de Fluorescência
11.
J Hosp Infect ; 74(3): 212-8, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20061058

RESUMO

Two different hand rubs were tested in order to investigate the minimum volume required for microbicidal efficacy according to the European Norm EN 1500; we also sought to determine whether there is a correlation with hand size. Eight male volunteers with big hands (mean 184 cm(2)) and eight female volunteers with significantly smaller hands (mean 148 cm(2); P<0.001) participated in our study. Application of 2 mL of both products (P) provided mean log(10) reductions significantly smaller than those of the reference disinfectant (R) (product A: P=3.34, R=4.00, P=0.001; product B: P=3.37, R=3.75, P=0.022). Higher volumes (product A: 3 and 4 mL; product B: 2.5, 3 and 4 mL) ensured that the pass criteria of the European Norm (EN) 1500 were fulfilled. For both products log(10) reductions increased with increasing product volume until a plateau was reached. For the smaller female hands, this plateau level was reached after applying 3 mL of product A and 2.5 mL of product B. The plateau level on male hands was observed after treating the hands with > or =4 mL of product A and 3 mL of product B. The increase in product volume also correlated with the decrease in the number of volunteers considering the product volume applied as insufficient. In conclusion, the applied volume for hygienic hand rub should not fall below 3 mL in order to achieve maximum benefit.


Assuntos
Álcoois/administração & dosagem , Bactérias/efeitos dos fármacos , Bactérias/isolamento & purificação , Desinfetantes/administração & dosagem , Desinfecção das Mãos/métodos , Mãos/microbiologia , Contagem de Colônia Microbiana , Feminino , Humanos , Masculino , Resultado do Tratamento
14.
Appl Environ Microbiol ; 72(2): 1380-7, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16461690

RESUMO

Water delivered by dental unit water systems (DUWS) in general dental practices can harbor high numbers of bacteria, including opportunistic pathogens. Biofilms on tubing within DUWS provide a reservoir for microorganisms and should be controlled. This study compared disinfection products for their ability to meet the American Dental Association's guideline of <200 CFU x ml(-1) for DUWS water. Alpron, BioBlue, Dentosept, Oxygenal, Sanosil, Sterilex Ultra, and Ster4Spray were tested in DUWS (n = 134) in Denmark, Germany, Greece, Ireland, The Netherlands, Spain, and the United Kingdom. Weekly water samples were tested for total viable counts (TVCs) on yeast extract agar, and, where possible, the effects of products on established biofilm (TVCs) were measured. A 4- to 5-week baseline measurement period was followed by 6 to 8 weeks of disinfection (intermittent or continuous product application). DUWS water TVCs before disinfection ranged from 0 to 5.41 log CFU x ml(-1). Disinfectants achieved reductions in the median water TVC ranging from 0.69 (Ster4Spray) to 3.11 (Dentosept) log CFU x ml(-1), although occasional high values (up to 4.88 log CFU x ml(-1)) occurred with all products. Before treatment, 64% of all baseline samples exceeded American Dental Association guidelines, compared to only 17% following commencement of treatment; where tested, biofilm TVCs were reduced to below detectable levels. The antimicrobial efficacies of products varied (e.g., 91% of water samples from DUWS treated with Dentosept or Oxygenal met American Dental Association guidelines, compared to 60% of those treated with Ster4Spray). Overall, the continuously applied products performed better than those applied intermittently. The most effective products were Dentosept and Oxygenal, although Dentosept gave the most consistent and sustained antimicrobial effect over time.


Assuntos
Equipamentos Odontológicos , Desinfetantes/farmacologia , Desinfecção/métodos , Microbiologia da Água , Biofilmes/efeitos dos fármacos , Contagem de Colônia Microbiana , Consultórios Odontológicos , Desinfetantes/efeitos adversos , Desinfecção/normas , União Europeia , Humanos , Irrigação Terapêutica , Abastecimento de Água/normas
16.
Zentralbl Hyg Umweltmed ; 201(4-5): 297-309, 1998 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9916285

RESUMO

In the study reported here, several disinfectants for surfaces, instruments, hands and mucous membrane were tested for their effectiveness against methicillin-resistant strains of S. aureus and vancomycin-resistant enterococci. The results show that after use of the recommended concentrations with the recommended contact times, which were determined on the basis of the criteria for disinfectants according to the DGHM guideline for the testing and evaluation of chemical disinfection procedures, an adequate effect was able to be proved. Increased resistance of the methicillin-resistant S. aureus and vancomycin-resistant E. faecium strains to the tested disinfectants was not found. Only after use of diluted solutions differences in the bacterial count reductions were observed. In further studies it is to be investigated whether these differences are due to resistance to antibiotics or to intrinsic resistance.


Assuntos
Desinfetantes/farmacologia , Resistência Microbiana a Medicamentos , Enterococcus faecium/efeitos dos fármacos , Resistência a Meticilina , Staphylococcus aureus/efeitos dos fármacos , Vancomicina/farmacologia , Enterococcus faecium/genética , Testes de Sensibilidade Microbiana , Staphylococcus aureus/genética , Tensoativos/farmacologia
17.
Immun Infekt ; 16(3): 100-3, 1988 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-3042612

RESUMO

Group A streptococci are responsible for the induction of serious pyoderma and pharyngitis in humans. The nonsuppurative sequelae "acute rheumatic fever" (ARF) and "acute poststreptococcal glomerulonephritis" (APGN) do very often occur with variable attack rates in epidemics with these microorganisms. At present, immune complex formation in the blood circulation system, in situ complex formation within the glomeruli, antibody cross-reactions between beta-hemolytic group A streptococci and human kidney tissue as well as tissue damage independent of specific antibodies are intensively discussed to explain the pathogenesis of acute poststreptococcal glomerulonephritis. However, the pathophysiological course of APGN has not yet been precisely identified.


Assuntos
Glomerulonefrite/etiologia , Infecções Estreptocócicas/complicações , Complexo Antígeno-Anticorpo , Glomerulonefrite/imunologia , Humanos , Infecções Estreptocócicas/imunologia , Streptococcus pyogenes
18.
Zentralbl Hyg Umweltmed ; 198(5): 473-7, 1996 May.
Artigo em Alemão | MEDLINE | ID: mdl-9409903

RESUMO

Central dosing units for surface disinfectants can constitute a particular hygiene problem in hospitals if a biofilm can develop in the piping system despite the disinfectant solution that is present. In earlier studies it was able to be shown that oxygen-releasing compounds in particular were highly effective against microorganisms in generated biofilms. The purpose of the study presented was to investigate in a test simulating practical conditions whether, in addition to the described good effect, peroxide-containing solutions also have a uniform effect against all isolates from disinfectant use-solutions, or whether there are differences. The results show that a 1% H2O2 solution (C) was not sufficiently effective against all test organisms after a contact time of one hour. In contrast, the 1% test solution of A (10% perglutaric acid, 28% H2O2, < 0.5% perbenzoic acid) was highly and uniformly effective. The 3% test solution of B (10% tertiary butylhydroperoxide, 20% phenoxypropanols, 48% dipropylene glycol) exhibited weaknesses against some test organisms after the one-hour contact time. After a contact time of three hours, this solution, unlike the 1% H2O2 solution achieved a reduction in bacterial count of more than 5 log steps against all species. On the basis of these results, before cleaning piping systems it appears advisable to test the effectiveness of the solution to be used in a suitable test with the isolates.


Assuntos
Biofilmes/efeitos dos fármacos , Desinfetantes/farmacologia , Peróxidos/farmacologia , Animais , Contagem de Colônia Microbiana , Relação Dose-Resposta a Droga , Humanos , Peróxido de Hidrogênio/farmacologia
19.
Zentralbl Hyg Umweltmed ; 195(5-6): 366-76, 1994 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-7916864

RESUMO

Phenoxypropanols have been used for some time as ingredients in surface and instrument disinfectants. Since the residual solutions of these preparations are discharged into the waste-water, the biodegradability of the ingredients used is of great importance. Tests by means of the Zahn-Wellens test in accordance with OECD guidelines have shown that phenoxypropanols are biodegradable. In further studies it was investigated whether unwanted intermediate products are formed in considerable amounts. Of particular interest was the question of the possible development of phenol outside the bacterial cells. To test the biodegradability of the aromatic alcohols and to ascertain whether there is extracellular formation of phenol, microorganisms were isolated from the municipal sewage plant at Stellinger Moor, Hamburg, and from water from the River Elbe. Phenoxypropanol-containing solutions were then inoculated with the bacteria and incubated at 30 degrees C. At regular intervals both the concentration of the alcohols was determined and the test for phenol was performed by means of liquid chromatography on reverse phase material (RP 18) and detection with a photodiode array detector. The breakdown of the phenoxypropanols was monitored for a period of up to 4 weeks. During this period a clear breakdown of the aromatic alcohols was observed. No phenol was detected.


Assuntos
Bactérias/metabolismo , Desinfetantes/metabolismo , Propilenoglicóis/metabolismo , Microbiologia da Água , Biodegradação Ambiental , Biomassa , Cromatografia Líquida de Alta Pressão , Água Doce , Alemanha , Fenol , Fenóis/análise , Esgotos
20.
Infect Immun ; 55(10): 2416-9, 1987 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-2443450

RESUMO

Two murine monoclonal antibodies (immunoglobulin M) evoked against human kidney tissue were examined for cross-reactivity with group A streptococci. A glomerulus-specific antibody, PMII.40.H.2, cross-reacted in an enzyme-linked immunosorbent assay with purified pepsin-extracted M proteins from type 6 and 12 streptococci, but not type 1, 3, 5, 19, and 24 M proteins. The cross-reactive monoclonal antibody also opsonized type 6 and 12 streptococci, indicating that it was directed against protective M protein epitopes that were exposed on the surfaces of these organisms. A control antibody, which was tubule specific, did not cross-react with any of the purified M proteins, nor did it opsonize any of the serotypes of streptococci tested. Western immunoblot experiments identified the glomerular cross-reactive antigen as a 43-kilodalton protein. The results demonstrate that M protein of group A streptococci and glomerular antigens of the human kidney possess cross-reactive determinants.


Assuntos
Anticorpos Monoclonais/imunologia , Antígenos de Bactérias/imunologia , Proteínas da Membrana Bacteriana Externa , Proteínas de Bactérias/imunologia , Proteínas de Transporte , Glomérulos Renais/imunologia , Streptococcus pyogenes/imunologia , Animais , Reações Cruzadas , Ensaio de Imunoadsorção Enzimática , Epitopos/imunologia , Imunofluorescência , Humanos , Imunoensaio , Proteínas Opsonizantes , Fagocitose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA