1.
Med Eng Phys ; 30(7): 825-33, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17977050

RESUMO

This study directly measured the load acting on the abutment of the osseointegrated implant system of transfemoral amputees during level walking, and studied the variability of the load within and among amputees. Twelve active transfemoral amputees (age: 54 +/- 12 years, mass: 84.3 +/- 16.3 kg, height: 17.8 +/- 0.10 m) fitted with an osseointegrated implant for over 1 year participated in the study. The load applied on the abutment was measured during unimpeded, level walking in a straight line using a commercial six-channel transducer mounted between the abutment and the prosthetic knee. The pattern and the magnitude of the three-dimensional forces and moments were revealed. Results showed a low step-to-step variability of each subject, but a high subject-to-subject variability in local extrema of body-weight normalized forces and moments and impulse data. The high subject-to-subject variability suggests that the mechanical design of the implant system should be customized for each individual, or that a fit-all design should take into consideration the highest values of load within a broad range of amputees. It also suggests specific loading regime in rehabilitation training are necessary for a given subject. Thus the loading magnitude and variability demonstrated should be useful in designing an osseointegrated implant system better able to resist mechanical failure and in refining the rehabilitation protocol.


Assuntos
Amputados/reabilitação , Adulto , Idoso , Amputação Cirúrgica/reabilitação , Membros Artificiais , Fenômenos Biomecânicos , Engenharia Biomédica/métodos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osseointegração , Próteses e Implantes , Estresse Mecânico , Caminhada , Suporte de Carga
2.
Gait Posture ; 31(2): 223-8, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19926285

RESUMO

The purpose of this proof-of-concept study was to determine the relevance of direct measurements to monitor the load applied on the osseointegrated fixation of transfemoral amputees during static load bearing exercises. The objectives were (A) to introduce an apparatus using a three-dimensional load transducer, (B) to present a range of derived information relevant to clinicians, (C) to report on the outcomes of a pilot study and (D) to compare the measurements from the transducer with those from the current method using a weighing scale. One transfemoral amputee fitted with an osseointegrated implant was asked to apply 10 kg, 20 kg, 40 kg and 80 kg on the fixation, using self-monitoring with the weighing scale. The loading was directly measured with a portable kinetic system including a six-channel transducer, external interface circuitry and a laptop. As the load prescribed increased from 10 kg to 80 kg, the forces and moments applied on and around the antero-posterior axis increased by four-fold anteriorly and 14-fold medially, respectively. The forces and moments applied on and around the medio-lateral axis increased by nine-fold laterally and 16-fold from anterior to posterior, respectively. The long axis of the fixation was overloaded and underloaded in 17% and 83% of the trials, respectively, by up to + or - 10%. This proof-of-concept study presents an apparatus that can be used by clinicians facing the challenge of improving basic knowledge on osseointegration, for the design of equipment for load bearing exercises and for rehabilitation programs.


Assuntos
Amputados/reabilitação , Terapia por Exercício/métodos , Monitorização Fisiológica/instrumentação , Suporte de Carga , Amputação Cirúrgica/reabilitação , Fenômenos Biomecânicos , Desenho de Equipamento , Humanos , Masculino , Microcomputadores , Pessoa de Meia-Idade , Software , Transdutores
3.
Prosthet Orthot Int ; 32(1): 68-78, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18330805

RESUMO

This study aimed to provide a description of the continuous recording of the true load regime experienced during daily living by the abutment of a trans-femoral amputee fitted with an osseointegrated fixation. The specific objectives: (i) To present an apparatus and a procedure allowing recording of the load regime, and (ii) an example of the raw data and six performance indicators of the usage of the prosthesis obtained with this method. A subject was monitored for a period of 5 hours as he went about his daily activities. The load regime was directly measured and recorded using a commercial transducer and data logger. The overall load profile presented alternative periods of variable length of inactivity (64%) and activity (36%), respectively. The maximum load applied on the mediolateral, anteroposterior and the long axes represented 21%, 21% and 120% of the body weight, respectively. The anteroposterior, mediolateral and long components of the impulse were 395 kN.s, 359 kN.s and 2,323 kN.s, respectively. The amputee generated a total of 2312 gait cycles of the prosthetic leg, giving an approximate overall cadence of 8 stride/min. Preliminary outcomes indicated that the proposed method was an improvement on the current techniques as it provided the true loading and actual usage of the prosthesis during daily living. This study is a stepping stone in the development of future affordable, on-board and user-friendly load recording systems that can be used in evidence-based practice.


Assuntos
Amputação Cirúrgica/reabilitação , Membros Artificiais , Marcha/fisiologia , Osseointegração , Atividades Cotidianas , Adulto , Amputados , Fenômenos Biomecânicos , Medicina Baseada em Evidências , Humanos , Extremidade Inferior , Masculino , Ajuste de Prótese , Transdutores